Tender For Construction Of Extension Of Fiac Turekela, District- Balangir
Tender Value
29.16 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
6 days left
EMD
29170
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Extension Of Fiac Turekela, District- Balangir
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation of foundation in all kinds of soil within 50M initial lead and 1.5M initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 m in depth including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work etc. complete as per the direction of the EIC. |
| 2 | Supplying, Filling sand in foundation & plinth well watered and rammed including cost, conveyance, taxes, royalty of sand, labour & T&P etc. complete as per specification and direction of the EIC. |
| 3 | Cement Concrete (1:4:8) by using 40 mm size hard granite crusher broken stone metal of approved quality and from approved quarry including lowering laying concrete, watering and curing etc. complete for required levels laid in layers including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work etc. complete as per the direction of the EIC. |
| 4 | Reinforced Cement Concrete M20 grade 20mm & down graded size hard granite crusher broken chips of approved quality and from approved quarry including centring, shuttering, lowering, laying concrete, watering and curing etc. complete for required levels laid in layers including cost, conveyance, royalty and taxes of all materials and cost of labour, T&P, required for the work etc. complete as per specification and direction of the EIC. |
| 5 | Column base, footing, plinth band, Bed Block, mass concrete |
| 6 | Column & Beam |
| 7 | Ground Floor |
| 8 | First Floor |
| 9 | Second Floor |
| 10 | Lintel |
| 11 | Ground Floor |
| 12 | First Floor |
| 13 | Second Floor |
| 14 | Ground Floor |
| 15 | First Floor |
| 16 | Second Floor |
| 17 | Stairs |
| 18 | Ground Floor |
| 19 | First Floor |
| 20 | Chajja |
| 21 | Ground Floor |
| 22 | First Floor |
| 23 | Second Floor |
| 24 | Supplying MS round / deformed / tor steel reinforcement bars (of only manufacturing companies such as SAIL / RINL / TATA / JINDAL STEEL / SHYAM STEEL) (of approved grade) of required diameters of approved quality including straightening, cutting to size, bending, and binding, lifting and placing in position as per design, complete including cost of bars, binding wires 18 gauge, including cost of all materials , labour, conveyance, loading and unloading, taxes, cess, royalties. sundries, tools and plants etc. complete as per the direction of the EIC. (Linear measurement will be taken and quantity will be calculated on standard weight for all heights). |
| 25 | Ground Floor |
| 26 | First Floor |
| 27 | Second Floor |
| 28 | Providing Fly Ash brick masonry work using 230 mm X 110 mm X 80 mm (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:6 (1 cement : 6 sand) (Using Branded Cement), immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. complete as per the direction of the EIC. |
| 29 | In Ground Floor |
| 30 | Superstructure |
| 31 | Foundation and plinth |
| 32 | In First Floor |
| 33 | In Second Floor |
| 34 | 2.5 cm thick grading concrete [1:2:2 ] on roof slab with 6 mm size chips including rubbing and polishing etc. complete including cost, conveyance, royalty and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the EIC. |
| 35 | In First Floor |
| 36 | In Second Floor |
| 37 | Plain cement concrete (1:2:4) using 12 mm size hard granite crusher broken chips of approved quality and form approved quarry including lowering laying concrete, watering and curing etc. complete for required levels laid in layers including cost and conveyance, royalty & taxes of all materials and cost of all labour T&P required for the work etc. complete as per the direction of the EIC. |
| 38 | 16 mm thick cement plaster in cement mortar (1:6) with watering and curing etc. complete including cost, conveyance, royalty and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the EIC. |
| 39 | In Ground Floor |
| 40 | In First Floor |
| 41 | In Second Floor |
| 42 | Finishing surface of walls with cement based wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials labour T & P etc. as per direction of Engineer -In -charge. |
| 43 | In Ground Floor |
| 44 | In First Floor |
| 45 | Priming one coat to wall surface with water bound cement primer complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of EIC |
| 46 | In Ground Floor |
| 47 | In First Floor |
| 48 | 12 mm thick cement plaster in cement mortar (1:6) with watering and curing etc. complete including cost, conveyance, royalty and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the EIC. |
| 49 | In Ground Floor |
| 50 | In First Floor |
| 51 | In Second Floor |
| 52 | 6 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment complete including cost, conveyance, royalty and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the EIC. |
| 53 | In Ground Floor |
| 54 | In First Floor |
| 55 | In Second Floor |
| 56 | Wall painting 2 coat with Plastic emulsion paint of approved shade on new work to give an even shade inculding cost of paint. |
| 57 | In Ground Floor |
| 58 | In First Floor |
| 59 | In Second Floor |
| 60 | Wall Painting 2 coat with weather coat of approved shade on new work to give an even shade including cost of paint |
| 61 | In Ground Floor |
| 62 | In First Floor |
| 63 | In Second Floor |
| 64 | Supplying, fitting and fixing of MS Fabricated Panelled Door/Window/Grills as per approved specification complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the EIC. |
| 65 | Priming one coat to surface with Red oxide Primer complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the EIC. |
| 66 | In Ground Floor |
| 67 | In First Floor |
| 68 | In Second Floor |
| 69 | Painting two coats with approved paint on new iron work complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the EIC. |
| 70 | In Ground Floor |
| 71 | In First Floor |
| 72 | In Second Floor |
| 73 | Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\"x2'0\\" with Gypsum board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge |
| 74 | In Ground Floor |
| 75 | In First Floor |
| 76 | Supplying, fitting & fixing of Vitrified tiles in floors of size 600mmx 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only ) |
| 77 | In Ground Floor |
| 78 | In First Floor |
| 79 | Fixing of Vitrified tiles 60 cm x 60 cm (plain / ivory) series in dado, skirting and risers of steps on 12mm thick cement plaster in mortar (1:3) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles in ground floor. |
| 80 | In Ground Floor |
| 81 | In First Floor |
| 82 | Fixing Ceramic tiles in Floors, Treads on steps & landing on 25 mm thick bed of cement mortar [1:1] joined with neat cement slurry mixed with pigment to match the shade of the Tiles including rubbing and polishing complete including cost, conveyance, royalty and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 83 | In Ground Floor |
| 84 | In First Floor |
| 85 | Fixing Ceramic tiles 20 cm x 30 cm / 20 cm x 20 cm in Dado, Skirting and rises of steps on 12 mm thick cement mortar [1:3] joined with neat cement slurry mixed with pigment to match the shade of the Tiles including rubbing and polishing complete including rubbing and polishing etc. complete including cost, conveyance, royalty and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction of the EIC. |
| 86 | In Ground Floor |
| 87 | In First Floor |
| 88 | Fixing Capsule tiles in floors treads of steps and landing on 25mm thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost, conveyance, royalty and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction for the EIC. |
| 89 | In Ground Floor |
| 90 | In First Floor |
| 91 | Cost of Aluminium Composite panel type (single shutter) frame doors including cost, conveyance,excluding GST of all materials, labour and T&P etc. complete |
| 92 | 12 mm (½”) thick cement plaster (1:4) finished smooth to outside smooth surface of brick walls after raking out the jointand excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 93 | Cement punning including watering and curing with cost, conveyance, royalties, and excluding GST of all materials with all labour and T&P required for the work complete in all respect. |
| 94 | Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. as per direction of the Engineer-in-charge |
| 95 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures as per the direction of EIC. |
| 96 | Internal Electrification Work |
| 97 | Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, 250 V piano type switch ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex / L&T / Anchor / Havels / V Guard ) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. [Group-C] |
| 98 | Light point |
| 99 | Office 1 |
| 100 | Office 2 |
| 101 | Office 3 |
| 102 | FIAC Staff Office |
| 103 | Corridor |
| 104 | Staircase |
| 105 | Lavatory 1 |
| 106 | Lavatory 2 |
| 107 | Lavatory 3 |
| 108 | Lavatory 4 |
| 109 | Storage/Record Room |
| 110 | Fan point |
| 111 | Office 1 |
| 112 | Office 2 |
| 113 | Office 3 |
| 114 | FIAC Staff Office |
| 115 | Corridor |
| 116 | Exhaust Fan |
| 117 | Lavatory 1 |
| 118 | Lavatory 2 |
| 119 | Lavatory 3 |
| 120 | Lavatory 4 |
| 121 | Storage/Record Room |
| 122 | Providing, Supplying and fixing of metal box of 200 mm x 150 mm x 60 mm (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc as required. (For light plugs to be used in non residential buildings) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 123 | Office 1 |
| 124 | Office 2 |
| 125 | Office 3 |
| 126 | FIAC Staff Office |
| 127 | Corridor |
| 128 | Storage/Record Room |
| 129 | Providing, Supplying and fixing of metal box of 150 mm x 75 mm x 60 mm (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc as required. (For light plugs to be used in non residential buildings) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 130 | Office 1 |
| 131 | Office 2 |
| 132 | Office 3 |
| 133 | FIAC Staff Office |
| 134 | Corridor |
| 135 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick alongwith 1 x1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (Make of wire Finolex/ L&T/Anchor /Havels /V Guard) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 136 | Providing & Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(Make of wire Finolex/L&T/Anchor/Havels/V Guard) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 137 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR) complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 138 | Providing & Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 139 | Supplying and fixing batten holder / BK angle holder ISI marked including connection etc. as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the worketc. complete as per the direction for the EIC. |
| 140 | Supply and fixing of 5 amp to 32 amp rating 240 V \\"C\\" series miniature circuit breaker suitable for inductive loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 141 | Supply, Installation, Testing, and Commissioning of 32 Amp DP Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. Make- SEIMENS /HPL /ANCHOR /L&T /HAVELS /C & S/ RK |
| 142 | Supply, Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 143 | Supply, Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work etc. complete as per the direction for the EIC. |
| 144 | Installation, testing and commissioning of exhaust fan 300 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required complete including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work, etc. complete as per the direction for the EIC. |
| 145 | Internal PH & Sanitary works |
| 146 | Providing and fixing to wall or ceiling and floor pvc pipes class conforming to ASTM-D- 1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification complete. |
| 147 | 25 mm dia PVC ASTM pipe (sch-80) |
| 148 | Fixing Wash Down Water Closet (European type W.C pan) with integral or trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification. |
| 149 | Providing and fixing 10 litre capacity - White P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete |
| 150 | Suppying and fixing Porcelain 22\\"x 16\\"(550x400) Wash Hand Basin with approved make & model with CI brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc including fixing Chromium Plated waste pipe of 32 mm nominal diameter, Chromium Plated Pillar taps & Chromium Plated Angle Valve of 15 mm dia nominal bore with approved make & model, 15 mm dia PVC inlet connection pipe as per P.H specification including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work complete as per the direction for the EIC. |
| 151 | Supplying and fitting 15mm dia C.P. short body bib cock with supply of all jointing materials as per P.H specification including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work complete as per the direction for the EIC. |
| 152 | Supplying and fitting 15mm dia C.P. long body bib cock with supply of all jointing materials as per P.H specification including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work complete as per the direction for the EIC. |
| 153 | Supplying and fixing 90 mm dia P.V.C. Nahani Trap [PVC floor traps] as per P.H specification including cost, conveyance and taxes of all materials and cost of all labour with T&P required for the work complete as per the direction for the EIC. |
| 154 | Providing and fixing on wall face OD P.V.C. SWR S/S Pipe (ISI type-A) soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes |
| 155 | 110 mm OD P.V.C. SWR S/S Pipe (ISI type-A) |
| 156 | 75 mm OD P.V.C. SWR D/S Pipe (ISI type-A) |
| 157 | Providing and fixing on wall face PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion |
| 158 | 110mm dia PVC SWR coupler |
| 159 | 110 x 110 x 110mm dia PVC SWR Tee |
| 160 | 110mm diaP.V.C. SWR door bend 87.5' |
| 161 | 75mm dia PVC SWR coupler |
| 162 | 75mm dia PVC SWR Tee |
| 163 | 75mm diaP.V.C. SWR door bend 87.5' |
| 164 | Fixing 1000 litre capacity Double Layer Rotational Moulded Cylinderical Vertical water storage tanksincluding cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 10.00 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysSep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender