Rural Development Government Departments Closing in 14 days TDR #57395239

Tender For Govt Ughs Jadamunda Building In The District Of Nuapada

Issued by Government Departments · Kalahandi, Odisha
Tender Value
1.44 Crore
Estimated cost
Bid Submission
29 Sep 2026
14 days left
EMD
1.44 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kalahandi → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Govt Ughs Jadamunda Building In The District Of Nuapada

BOQ

Name of Work:- Govt UGHS JADAMUNDA Building in the district of Nuapada
Sl. No. Item Description
1Civil Earth work in excavation of foundation trenches in hard soil including dressing and leveling the bed upto the required depth and depositing the excavated materials with all leads and lifts T&P shoring & Shuttering if required etc. complete as directed by the Engineer-in-charge.
2Supplying filling in foundation and plinth with sand including watering ramming, cost, conveyance, royalties and all taxes of materials and cost of labour with T&P required for the work etc. complete (measurement will be taken on finished section only etc.complete as directed by the Engineer-in-charge.
3Cement concrete (1:3:6 ) in foundation and plinth below the base course of terrazzo flooring using 4cm (1 1/2\\") size black hard hand broken granite stone metals of approved quality from approved quarry including lowering laying concrete watering and curing etc. complete to required levels laid in layers not exceeding 0'-6\\" thick inlcuding cost, conveyance, royalties and all taxes of all materials and cost of all labour with T & P required for the work complete.
4Brick masonary in cement mortar (1:6) using K.B.Bricks / Cement flyash of size 10\\" x 5\\" x 3\\" having crushing strength not lessthan 75 Kg/Cm2 after immersing the bricks for six hours in water before use in Foundation and plinth in all florrs with all necessary projection, cutting mlulding, corbelling, champering, watering and curing including cost conveyance, royalties and taxes of all materials and labour T&P required for the work etc.complete as per the direction of Engineer in Charge. Ground Floor
5R.C.C.work of M-25 having a minimum comprresive strength (in work test) 250 kg/Cm2 in 15 cm cubes at 28 days after mixing and test conducted in accordance with IS 456 and IS 516 using 12mm size black hard crusher broken granite chips including hoisting,lowering laying and compacting concrete by using vibrator with watering and curing for 28 days centering and shuttering and finishing the exposed surface smooth providing grooves or beds whereever necessay including cost conveyance,royalties and all taxes of all materials and cost of all labour with T&P required for the work etc.complete in all respect but excluding cost of M.S.Rods or Tor Steel and binding wires and labour charge for bending binding and tying the grills etc.complete in all respect as per direction of Engineer-in-charge. Column Base & Footing
6First Floor
7Plinth Bend/Grade Beam Ground Floor
8Second Floor
9Bed Block Ground Floor
10Lintel Band Ground Floor
11First Floor
12First Floor Column in Super structure Ground Floor
13First Floor
14Wall Beam & T-Beams Ground Floor
15First Floor
16Stair Case Ground Floor
17Chajja & Fin Ground Floor
18Roof Slab Ground Floor
19First Floor
20Providing HYSD bar reinforcement for R.C.C. work including Straightening, cutting, bending, binding, welding, tying the grills, laying and placing in proper position as per approved design and drawing including cost, conveyance of 18 to 20 gauge binding wire cost and conveyance of HYSD bars complete in all respect as per specification for road & Bridge and direction of Eng - in Charge. Ground Floor
21First Floor
22Brick masonary in cement mortar (1:6) using K.B.Bricks/Cement flyash of size 10\\" x 5\\" x 3\\" having crushing strength not lessthan 75 Kg/Cm2 after immersing the bricks for six hours in water before use in superstructure in all florrs with all necessary projection, cutting mlulding, corbelling, champering, watering and curing including cost conveyance, royalties and taxes of all materials and labour T&P required for the work etc.complete as per the direction of Engineer in Charge. Ground Floor
23First Floor
2420mm thick grading cement plaster ( 1:4 ) finished smooth over R.C.C.slab including watering curing cost conveyance royalty and labour required for the work etc.complete as per direction of Engineer-in-charge. Ground Floor
25First Floor
2612mm(1/2\\")thick cement plaster (1:4) in all floors over brick work finished smooth including cement punning and Bitumen painting including watering, curing, cost conveyhanace, royalty and all taxes of all materials and labour with T&P required for the work etc.complete as per direction of Engineer-in-charge. Ground Floor
27First Floor
2812mm(1/2\\") thick cement plaster (1:6) in finished smooth to outside smooth surface of brick walls afrer racking out joints including watering and curing etc.complete with cost,conveyance royalties,all taxes and cost of all materials and cost of all labour with T&P requred for the work complete. as per the direction of Engineer in Charge. Ground Floor
29First Floor
3016mm(5/8\\") thick cement plaster (1:6)in finished smooth to inside smooth surface of brick walls afrer racking out joints including watering and curing etc.complete with cost,conveyance royalties,all taxes and cost of all materials and cost of all labour with T&P requred for the work complete. as per the direction of Engineer in Charge. Ground Floor
31First Floor
3220mm thick cement plaster (1:6)in finished smooth to inside smooth surface of brick walls afrer racking out joints including watering and curing etc.complete with cost,conveyance royalties,all taxes and cost of all materials and cost of all labour with T&P requred for the work complete. as per the direction of Engineer in Charge. Ground Floor
33Supplying,fitting and fixing of M.S. doors, windows and iron grill gate made out of (45x45x60)mm size angular frame with square bar M.S. flat for grills of approved design icluding all cost conveyance taxes etc. complete. ( Prevaling lowest local market rate and excluding labour for fixing ) Ground Floor
34First Floor
35Labour for fitting and fixing of MS Shutters for doors, window and grill gates, Collapsible gate including filling the holes with C.C (1:3:6) etc.complete as per the direction of Engineer in Charge. Ground Floor
36First Floor
37Fixing of vetrified tiles in floors,treads and landings on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge. Ground Floor
38Fixing of Vetrified tiles in dados,skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge. Ground Floor
39Fixing chequred tiles in floors,treads and landings on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge. Ground Floor
40Supplying, fitting afixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials labour, T&P etc. required for the complete in all respect. etc. complete etc.complete as per direction of Engineer-in-charge. Ground Floor
41Finishing wall surface with two coats of approved quality of weather seal coat of approved shade over a coat of primer including cost of all materials etc. complete. as per direction of Engineer In Charge. Ground Floor
42First Floor
43Finishing wall surface with acrylic wall putty finished smooth to exposed new plastered surface including cost of all materials etc.complete. as per direction of Engineer In Charge. Ground Floor
44First Floor
45Painting two coats in all floors to new wood and iron work over a coat of primer including sand papering,polishing the surface,including cost conveyance royalties and all taxes of all materials alongwith T&P required for the work including cost of paint & primer complete in all respect as per the direction of Engineer in Charge. Ground Floor
46First Floor
47Cement washing one coat including watering ,curing with cost,conveyance, royalities of cement etc.Complete as per direction of Engineer-in-Charge. Ground Floor
48First Floor
49Distempering two coat over the including cost of distemper cost conveyance and all taxes of all materials and labor with T&P required for the work etc.complete in all respect etc. complete as per direction of Engineer in charge. Ground Floor
50First Floor
51Cement concrete of proportion (1:2:4) with 12mm (1/2\\") size hard granite crusher broken chips including watering curing, cost, conveyance, royalties and all taxes of all materials labour with T&P required for the work etc.complete as per direction of Engineer-in-charge.Ground Floor
52Earthwork in hard soil with initial lead and lift including rough dressing and breaking clods upto 5cm to 7cm size and laying in layers each layer not exceeding 0.3m in depth etc. complete as directed by the Engineer-in-charge. ( By Mechanical means )
53Providing PVC Pipe 100 mm dian for rain water drainage from top up siab to ground including all labour and with clamps & fitting as per direction of the Engineer in charge
54Providing and applying of post construction Anti-termite treatment by drilling 12mm dia holes at distance of 30cm junction of wall and floor about 300mm aprt deep enough to reach the soil below and chemical emulsion PREMISE, IMIDACHLOPRIED30.5 SC OF BAYER MAKE MIXED WITH 47.5 Ltr. WATER pump these holes to soak the soil 1 ltr. Solution of each hole as per manufactures specification and the holes should be pluged with filling materials including coat of all materials, labour conveyance and hiring charges of machineries all taxes as per direction of EIC.
55Supplying , fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick Sunmica on both side of approved design and quality including cost of all door with frame fitting and fixture etc complete(SR 2022 misla. item no-9/page-234) Ground Floor
56First Floor
57Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6 mm thick glass of approved quality complte with frame,shutters and all fiiting and fixtures (SR-2022 Mis. item n0-13/page no-235) Ground Floor
58EI Work Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Havels /HPL/ V Guard ) -do- Group A
59-do- Group B
60-do- Group C
61Recessed wiring to Fan Point in... -do- Group B
62Recessed wiring to Call Bell Point in... -do- Group C
63Recessed wiring to Exhaust Fan Point in do- Group B
64S/F of Angle holder replacing Ceilling Rose (1.29-1.28)
65S/F of fan hook 'S' type made of 16 mm MS rod for fixing in the Existing RCC Roof.
66S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board (1.25.1+1.25.4)
67S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required.
68S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required
69S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket & Mini DP MCB, connection, painting etc as required for AC
70S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover.
71S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection
72S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. 2 Modular box with base & cover
734 Modular box with base & cover
746 Modular box with base & cover
758 Modular box with base & cover
7612 Modular box with base & cover
77Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard)2x1.5+1x1.0 (1.8)
782x2.5+1x1.5 (1.8.2)
792x4+1x1.5 (1.8.3)
802x6+1x2.5 (1.8.4)
814x10+2x4(1:8:11)
82Inverter wiring (1x1.5smm) Copper wire (1.19.1)
83S/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1)
84S/F of 'B/C/D' series DP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the 2 Way double door MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required (2.6.2a)+(2.3.1b)
85S/F of MCB 12 way Double door (2.3.7)
86Supply & laying 6 SWG G.I. wire in recess for loop earthing as required (3.17)
87Providing & fixing plain 16/0.2mm twin twisted flexible, FR PVC insulated copper cable in polythene sleeve or conduit of suitable size on the floor/wall or side of the table/door etc as required.(1.31)
88S/F of 300 Exhaust fan with all accessoriesand connections (Make Usha-Aero Clean Plus DBB/ Polycab-Fresh on DBB/ Cropmton-Trans Air12\\" reversible/ Havells-Ventil Air DS(HS)/ Anchor-Anmol Delus R/ Orient-Power Flow DBB)
89S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30)
90S/F of 18-25 wt. LED single strip tube. Light fittingwith all accessories & connection (make Havels/HPL/Crompton/Polycab/PAC)
91S/F of 1200mm A.C. Ceiling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton- HS /Havells-Samrat ES/Anchor- Turbo Speed Star/Orient-Summer Breeze Pro/ Great White-ALDOUS/Pollycab-Vital HS)
92Fixing /I.T.C. of stepped type Modular regulator (1.25a)
93S/F of 20mm dia down rod with all accessories (1.39+1.41)
94Supply & fixing of superior type C.I bulk head fitting with 9W Led Bulb for general domestic use ISI marked square / oval type with premetallic glass cover provided with galvanized steel wire guard including necessary connections. ( M-5 )
95S/F of 45-48 wt. LED St. Light fitting with LED Electronic driver with all accessories & connection( Make- Crompton/Phillips/HPL/Polycab/Havells )
96S/F of 12w Watt LED Bulb
97S/F of 2000VA/24V Invertor machine,Make-Heavy duty V-Turbo UPS-23509 (microtek)/PRIME 2250(V-GUARD)/EVO S 2300(LUMINOUS) and 180Ah tall tubular BatteryMake-Luminous /microtek/v-guard and 16A Delux plug Top with Luminous single Trolley for Inveryor Battery,2nos
98Supply & fixing of 100 A TPN Panel board 1. 100A MCCB (Make- Legrand/Seimens/L&T/C&S/) & 100A kitkat & bus bar2. 32 A TPN MCB (Make- Legrand/Seimens/L&T/C&S/)- 2nos 3. 32A DP MCB (Make- Legrand/Seimens/L&T/C&S/)- 5 nos 4. 100 A 4P Manual changeover (Make- Legrand/Seimens/L&T/C&S/)- 1nos5. Digital Volt meter & Ameter three phase 6. All accesories & Connection (Rating & Danger borad)
99PH Work Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge.Ground Floor 25mm dia C-PVC pipe (Ashirbad/Supreme)
100In 1st Floor-32mm dia C-PVC pipe (Ashirbad/Supreme)
101Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mm thick wall in Ground floor
102Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer in charge. in Ground Floor
103Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor
104Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.15mm dia CP Short Body Bib cock (Jaquar make)
10515mm dia CP angle stop cock (Jaquar make)
10615mm dia CP two in one bib cock (Jaquar make)
10715mm dia CP Health faucet (Jaquar make)
10815mm dia CP extension piece
10915mm dia CP Pillar cock (Jaquar make)
11025mm dia G.M or Brass F.W valve (Sakti make)
111125mm dia CP gratings
112Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge.10 litres PVC L.L. Cistern (Slimline-white)
113Supplying all materials, labour, T&P and fitting and fixing U PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge.75mm dia U-PVC SWR pipes(Supreme/Ashirvad)
11475mm U-PVC plain bend
11575mm U-PVC Door bend
116110mm dia U-PVC SWR pipes(Supreme/Ashirvad)
117110mm U-PVC door bend
118110mm U-PVC door Tee
119110mm U-PVC D/J with Door
120110mm dia U-PVC offset without ear
121110mm U-PVC plain bend
122110mm U-PVC vent cowl
12375mm U-PVC vent cowl
124110mm dia U-PVC 'P' trap
125110mm dia U-PVC socket plain
12675mm dia U-PVC socket plain
127PVC Clamp
128Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI P or S trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge(Nycer,parryware make).580mm size Orissa pan(Hindware/Parryware/Neycer)
129Supplying all materials, labour, T&P and fixing bowl pattern urinal including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification and direction of the Engineer in charge.porcelain Halfstall Magnum Urinal(Parryware/Hindware/Neycer)
13015mm dia Urinal spreder
13132mm dia cp waste pipe
132Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral S or P trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in charge.EWC with Seat Cover (Parryware/Hindware/Neycer)
133Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge.550mm x 400mm size W. H. Basin (Parryware/Hindware/Neycer)
134Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge.600mm x 450mm size B.E mirror
135Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.450mm x 125mm plate glass shelf with CP guard rails (Plaza/Amber/Aquatic)
136Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.20mm x 600mm long CP towel rail (Plaza/Amber/Aquatic)
137CP towel Ring (Plaza/Amber/Aquatic)
138Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.CP soap holder (Plaza/Amber/Aquatic)
139Factory made GIRID FRP or called GRP sandwich composite door shutter of 32mm thick laminated with two GRP skin with good grain finish fabricated using UV stabilised isoppthalic gel coat and one layer of 450 gsm E-glass chopped strand mat (CSM) impregnated with ortopathilic resin The thickness of the skins shall not be less than 1.50mm . Expanded polysryne ( EPS) structural foam panel of 29 mm tickness and a density of 20kg/cu.mts shall be used as core material wooden reinforcements made of sesasoned sal wood block of cross section not less than 28mm x 32mm and also necessary sal wood reinforcements for fitting the metal fittings such as lower bolts ,aldrops, handles etc. shall be provided . A structural adhesive compatible with (EPS)foam shall be used for bending the core material. the sal wood reinforcements and the skin The material and process for manufactuing te door shutter shall conform to RV -TIFAC components design centre's standards and specification and the door shutters tested in conformation to IS 4020-1998. The Finish of door shutter will be plain colour as per specification and direction of the Engineer in Charge. etc. complete
140Factory made FRP( Altematly called GRP) door frame of size 75mm x 100mm fabricated using E - glass chopped strand mat (CSM) U.V stabilised inopathalic Gel coat and impregnated with inopathalic resin The thickness of the GRP skins shall not be less then 2.0 mm . The door frame consists of four segments which are provided with plug in socket arrrangement in-situ-in mould. The segments are plugged in and are joined together by means of srew. The GRP frame shall be provided with wooden reinforcement on six locations for high srew holding capacity for fixing metalic hold fast and shall be consolidated by filling with medium density foam / plaster of paris with fibre reinforcement , six number of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame. The material and process for manufacturing the finish of door frame shall conform to RV-TIFAC composites Design centre's standards and specifications . The finish of door frame will be plain colour white /Ivory/Beige/Light grey / Golden brown / Mahogany/ Teak wood /sand stone Champagne/Pastel blue or any other colour using high quality pigment complete in all respect as per specification and direction of the Engineer in Charge. etc. complete
141Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Gully Trap chamber (0.25x0.25 inside size)
142Supplying all materials, labour, T&P and constructing Inspection Chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mm x 760mm x 460mm
143Supplying all materials, labour, T&P and providing Marble partition in urinal with cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc all complete as per direction of the Engineer in charge
144EXTERNAL PH LabourSinking of 200mmx150mm dia Bore Well through DTH method.- 1No. for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only. Drilling of 200mm dia bore 0 to 30.00mtr
145Drilling of 150mm dia bore 30.00 to 100.00 mtr and above
146Labour for lowering the following size of PVC casing pipes with or without slotted pipes as per necessity from ground level upto 300 mtrs depth and fitted and set up in perfectly vertical position including cutting and threading of blank pipes and slotted pipes and supplyinging and fixing of all jointing materials ,extra sockets and T&P etc. all complete and keeping the top of casing pipe threaded including plugging the tubewell to prevent entry of foreign materials.Lowering of 200mm dia PVC casing pipes 0 mtr to 30 mtrs
147Cost of 200mm dia PVC schedule - 80 pipe
148Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
149Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.1HP Three Phase 5 stage submersible pump set.
150DOL control panel
151M. S. Clamp, Bend, Socket ,SS nipple etc.
1522.50mm Sqm Submersible flat cable
153Steel rope with cover
15450mm dia HDPE pipe
155Labour charges for lowering, testing, commissioning & transportation to site etc.
156Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge .1.40m dia x 2.00m deep soakway pit
1570.90m dia x 2.00m deep soakway pit
158Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method as per manufactures specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia u-pvc pipe alround concrete
159160mm dia u-pvc pipe alround concrete
160Supplying all materials, labour, T&P and Fitting and Fixing of Rotational moulded polythene cylindrical vertical water storage tank of capacity 2000 litre conforming to 12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.L and placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
161Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx3.18m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
162Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C. Initial lift upto 1.50m
163- do - with addl. Depth of 1.5 m
164Supplying all materials, labour, T&P and filling in foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per the direction of the E.I.C.in ground Floor-
165Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site payment of royalry, taxes etc all complete as per P.H specification and direction of the E.I.C.in ground floor
166Supplying all materials, labour, T&P and providing plain cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.In ground Floor
167Supplying all materials,labour, T&P and providing Brick work with K.B.Brick having crushing strength not less than 75 Kg/CM2 with dimensional tolerence of +/- 8% in C.M including watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
168Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
169Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
170Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
171Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
172Supplying all materials, labour, T&P and providing reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
173Supplying all materials, labour, T&P and making M.S. Step Iron in 20mm Dia M.S Steel bars and fixing into walls of Manhole/ Septic Tanks duly embeded in C.C(1:2:4) etc all complete as per P.H specification and direction of the E.I.C.
174Supplying all materials, labour, T&P and providing 50mm thick pre-cast R.C.C. baffle wall in R.C.C(1:1.5:3) including reinforcement cage using 12mm size HG chips fitted and fixed in position, finished smooth etc. complete including cutting grooves and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.
175Supplying all materials, labour, T&P and providing 160mm dia P.V.C Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:1.5:3) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.
176Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.
177Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57395239
AUTHORITY Government Departments
TENDER VALUE 1.44 Crore
LAST DATE 29-09-2026
Authority
Authority Name Rural Works Department
Work Description Tender for Govt Ughs Jadamunda Building In The District Of Nuapada
Basic Detail
Tender No BPT/Online-12/2026-27
Bidding Type Tender
Location
City Kalahandi
State Odisha
Key Dates
Publish Date 08 Sep 2026
Submission Date 29 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 1.44 Crore
Tender Fee 10000
EMD 1.44 Lakhs
Exemption Available
Document List
532516b5-1bbe-4c07-b31f-13c7159838a3.html
BOQ_608631.xls
Tendernotice_1 (19).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

532516b5-1bbe-4c07-b31f-13c7159838a3.html

xls

BOQ_608631.xls

pdf

Tendernotice_1 (19).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail