Tender For Supply And Installation Of Physiotherapy Equipment Gsrq** Njsa
Tender Overview
Project Description
Tender for Supply And Installation Of Physiotherapy Equipment Gsrq** Njsa , Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Director Sports & Youth Welfare T.T. Nagar Stadium Bhopal Name Of Work: Supply And Installation Of Physiotherapy Equipment Gsrq** Njsa Contract No: --------- /Dsyw/Infra/2026 Name Of The Bidder/ Bidding Firm / Company : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Name Of Items & Specification Item Code / Make Quantity Unit Estimated Rate In Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Basic Rate In Figures To Be Entered By The Bidder Inrs.P (With Duty) Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Rates In (Without Duty) Brand Name/ Model No. Name Of Manufacturer Total Amount Without Taxes In Rs. P Total Amount With Taxes Total Amount In Words , Physiotherapy Equipment :- , Portable Dual-Action Cryo-Pneumatic Recovery System 1 Should Be Capable Of Adjusting Ice And Compression Aspect Of Rice Regimen In A User-Friendly Manner. 2 Manual Setting Should Be Available For Treatment In Steps Of 5 Minutes. 3 Temperature Control Settings Should Be From 1°C To 10C. 4 There Should Be Automatic Programs Of 30 Mts. On 30 Mts Off With At Least Three Different Pressures And 30 Mts On 60 Mts Off With Three Different Pressures. 5 There Should Be An Automatic Mode To Drain Out Water After Use. 6 Wraps Should Be Using Skin Friendly Technology Offering A Comprehensive Range Of Anatomically Design Ed Wraps For All Major Joints Of The Body. 7 Wraps Should Consist Of Heat Exchanger Along With Machine Washable Sleeves. 8 Should Be Highly Useful For A Variety Of Musculoskeletal Injuries And For Postoperative Rehabilitation. 9 There Should Be Provision For Display Of Water Temperature Going Into The Wraps. 10 There Should Be Provision Of Display Of Average Temperature Of Water Going Into And Coming Out Of Wraps. 11 Temperature Display Should Be Capable Of Being Selected In Degree Centigrade Or Degree Fahrenheit. 2 Should Be Able To Set Pressure Applied Minutely In The Ranges Of 5 Mm Hg., 15Mm Hg., 50Mm Hg. And 75Mm Hg. 13 Should Have The Following Wraps:- • Assembled Ankle Wrap • Assembled Straight Knee Wrap (One Size Fits All) - 1 No. • Assembled Shoulder Wrap Right - 1 No. • Assembled Shoulder Wrap Left) - 1 No. • Assembled Flexed Elbow Wrap (One Size Fits All) -1 No. • Assembled Back Wrap- 1 No. • Assembled Hip/Groin Wrap (Right And Left)-1 No. • Hand And Wrist Wrap (One Size Fits All)-1 No. • C-T Spine Wrap-1 No Cooling Vest-1 No. • Full Leg Boot Wrap With Attachment - 1No • Articulated Knee Wrap -1 No 14 Should Have The Following Accessories: - Dual Connector Hose- Sport • Carry Bag For Control Unit • Carry Bag For Wraps 15 Safety Specification: - Should Have Ce/Usfda/Appropriate Indian Medical Safety And Quality Standard Certification. 16 Warranty: 05 Years On Machine And Wraps 17 Safety Clause: As Per Existing Guideline For Patients. , Quad-Modality Iceless Contrast & Pneumatic Compression Console 1. Should Be Multi-Modality Injury Recovery Unit Comprising Cold, Hot, Rapid Contrast And Active Compression In A Single Unit 2. Cold Should Reach A Minimum Level Of 3 Degree C 3. Hot Should Reach A Maximum Level Of 45 Degree C 4. Changing Over From Hot To Cold And Vice Versa Should Take Less Than 1 Minute 5. Compression Should Have 4 Levels • Low Compression - 5Mmhg To 15Mmhg • Medium-Low Compression - 5Mmhg To 30Mmhg • Medium Compression - 5Mmhg To 50Mmhg • High Compression - 5Mmhg To 75Mmhg 6. Unit Should Be Able To Treat Two Individuals At One Time With Two Different Programs. 7. Customizable Programs For Each Individual Should Be Possible. Should Be Able To Customize Time Of Treatment, Cold Temperature, Hot Temperature, Compression Level 8. Should Have A Touch Screen To Set The Above Parameters 9. Should Not Require Adding Ice For Cold Therapy Or Hot Water For Hot Therapy In The System. Unit Must Have Compression System To Deliver Hold And Cold Therapy. 10. Wraps Should Be Using Latest Technology Offering A Comprehensive Range Of Anatomically Designed Wraps. 11. Wraps Should Consist Of Heat Exchanger Along With Machine Washable Sleeves. 12. Should Be Highly Useful For A Variety Of Musculo Skeletal Injuries And For Postoperative Rehabilitation. 13. Temperature Display Should Be Selectable In Degree Centigrade Or Degree Fahrenheit. Unit Must Be Supplied With Following Parts. • Assembled Ankle Wrap Large (Fits Mens Shoe Size 11 And Under) - 1 • Assembled Straight Knee Wrap (One Size Fits All) - 1 • Assembled Half Boot Wrap (One Size Fits All) - 1 • Assembled Shoulder Wrap Large, (Right And Left) - Total 2 (1-Right & 1-Left) • Assembled Flexed Elbow Wrap (One Size Fits All) - 1 • Assembled Back Wrap - 1 • Assembled Hip/Groin Wrap (Right And Left) - Total 2 (Right & Left) • Hand And Wrist Wrap (One Size Fits All) - 1 • Full Leg Boot Wrap With Atx, Medium - 1 Total In Figures 0.0 0.0 Inr Zero Only 4.0 Construction Of Chamber For 100Mm Sluice Plates Item5 10.0 Nos Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Director Sports & Youth Welfare T.T. Nagar Stadium Bhopal Name of Work: \\" Supply and Installation of Physiotherapy Equipment gsrq** njsa Contract No: --------- /DSYW/Infra/2026 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Name of Items & Specification Item Code / Make Quantity Unit Estimated RateinRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder inRs.P (With Duty) Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Rates in (Without Duty) BRAND Name/ Model No. Name of Manufacturer TOTAL AMOUNT Without Taxes in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Physiotherapy Equipment :- |
| 3 | Portable Dual-Action Cryo-Pneumatic Recovery System1 Should be capable of adjusting ice and compression aspect of RICE regimen in a user-friendly manner. 2 Manual setting should be available for treatment in steps of 5 minutes. 3 Temperature control settings should be from 1°C to 10\\"C. 4 There should be automatic programs of 30 mts. ON 30 mts OFF with at least three different pressures and 30 mts ON 60 mts OFF with three different pressures. 5 There should be an automatic mode to drain out water after use. 6 Wraps should be using skin friendly technology offering a comprehensive range of anatomically design ed wraps for all major joints of the body. 7 Wraps should consist of heat exchanger along with machine washable sleeves. 8 Should be highly useful for a variety of musculoskeletal injuries and for postoperative rehabilitation. 9 There should be provision for display of water temperature going into the wraps. 10 There should be provision of display of average temperature of water going into and coming out of wraps. 11 Temperature display should be capable of being selected in degree Centigrade or degree Fahrenheit. 2 Should be able to set pressure applied minutely in the ranges of 5 mm Hg., 15mm Hg., 50mm Hg. and 75mm Hg. 13 Should have the following wraps:- • Assembled Ankle Wrap • Assembled Straight Knee Wrap (one size fits all) - 1 no. • Assembled Shoulder Wrap Right - 1 no. • Assembled Shoulder Wrap Left) - 1 no. • Assembled Flexed Elbow Wrap (one size fits all) -1 no. • Assembled Back Wrap- 1 no. • Assembled Hip/Groin Wrap (Right and Left)-1 no. • Hand and Wrist Wrap (one size fits all)-1 no. • C-T spine wrap-1 no Cooling vest-1 no. • Full Leg Boot Wrap with attachment – 1no • Articulated Knee wrap -1 no 14 Should have the following accessories: - Dual Connector Hose- sport • Carry Bag for Control Unit • Carry Bag for wraps 15 Safety Specification: - Should have CE/USFDA/Appropriate Indian Medical Safety and Quality Standard Certification. 16 Warranty: 05 Years on Machine and Wraps 17 Safety clause: As per existing guideline for patients. |
| 4 | Quad-Modality Iceless Contrast & Pneumatic Compression Console1. Should be Multi-Modality injury recovery unit comprising cold, hot, rapid contrast and active compression in a single unit 2. Cold should reach a minimum level of 3 degree C 3. Hot should reach a maximum level of 45 degree C 4. Changing over from hot to cold and vice versa should take less than 1 minute 5. Compression should have 4 levels • Low compression – 5mmHg to 15mmHg • Medium-Low compression – 5mmHg to 30mmHg • Medium compression – 5mmHg to 50mmHg • High compression – 5mmHg to 75mmHg 6. Unit Should be able to treat two individuals at one time with two different programs. 7. Customizable programs for each individual should be possible. Should be able to customize time of treatment, cold temperature, hot temperature, compression level 8. Should have a touch screen to set the above parameters 9. Should not require adding ice for cold therapy or hot water for hot therapy in the system. Unit must have compression system to deliver Hold and cold therapy. 10. Wraps should be using latest technology offering a comprehensive range of anatomically designed wraps. 11. Wraps should consist of heat exchanger along with machine washable sleeves. 12. Should be highly useful for a variety of Musculo skeletal injuries and for postoperative rehabilitation. 13. Temperature display should be selectable in degree Centigrade or degree Fahrenheit. Unit must be supplied with Following parts. • Assembled Ankle Wrap Large (fits men's shoe size 11 and under) – 1 • Assembled Straight Knee Wrap (one size fits all) – 1 • Assembled Half Boot Wrap (one size fits all) – 1 • Assembled Shoulder Wrap Large, (Right and Left) – total 2 (1-Right & 1-left) • Assembled Flexed Elbow Wrap (one size fits all) – 1 • Assembled Back Wrap - 1 • Assembled Hip/Groin Wrap (Right and Left) – total 2 (Right & left) • Hand and Wrist Wrap (one size fits all) – 1 • Full Leg Boot Wrap with ATX, Medium – 1 Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender