Civil Aviation Boards / Undertakings / PSU Closing in 19 days TDR #57394855

Tender For Construction Of Staff Canteen; Frisking Room, Shed & Boundary Wall At Vip Gate; Store, Parking Shed & Other Miscellaneous Work At Rajkot International Airport (Sh: Civil & Electrical Works).

Issued by Boards / Undertakings / PSU · Rajkot, Gujarat
Tender Value
2.25 Crore
Estimated cost
Bid Submission
28 Sep 2026
19 days left
EMD
6.75 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajkot → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Staff Canteen; Frisking Room, Shed & Boundary Wall At Vip Gate; Store, Parking Shed & Other Miscellaneous Work At Rajkot International Airport (Sh: Civil & Electrical Works).

BOQ

Name of Work:- Construction of Staff Canteen; Frisking Room, Shed & Boundary Wall at VIP Gate; Store, Parking Shed & other Miscellaneous Work at Rajkot International Airport (SH: Civil & Electrical Works).
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
2Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited)
3Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soilPipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
4Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
5Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
6Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
9Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).
10Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
11Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
12Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
13Add for using extra cement in the items of design mix over and above the specified cement content therein.
14Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
15Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
16Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
17Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
18Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
19Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ)
20Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
21Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
22Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and wallsUnder 20 cm wide
23Centering and shuttering including strutting, propping etc. and removal of form for Weather shed, Chajjas, corbels etc., including edges
24Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
25Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
26Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
27Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
28Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
29Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood
30Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
31Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc.
32Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
33Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10 mm
34Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
35Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
36Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.Double strip (horizontal type)
37Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm
38Providing and fixing 19 mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS : 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in-charge.
39Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
40Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
41Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
42Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
43Providing and fixing bolts including nuts and washers complete.
44Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
45Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
46Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
47Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Dark shade pigment using ordinary cement
48Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
49Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
50Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
51Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of sizeSize of Tile 600 x 1200 mm
52Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
53Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 : 2000
54Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
55Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler110 mm
56Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee with door110x110x110 mm
57Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door110x110x110 mm
58Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°110 mm bend
59Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain)110 mm Shoe
60Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
61Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
6212 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
636 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
64Neat cement punning
65Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
66Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
67Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
68Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
69Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
70Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
71Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
72Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
73Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge.
74Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
75Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
76Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
77Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan.
78Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
79Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White
80Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
81Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :Flat back wash basin of size 550x400 mm
82Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe32 mm dia
83Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
84Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work25 mm nominal dia Pipes
85Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work50 mm dia nominal bore
86Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work65 mm dia nominal bore
87Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work80 mm dia nominal bore
88Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore
89Providing and fixing gun metal non- return valve of approved quality (screwed end) :50 mm nominal boreHorizontal
90Providing and fixing gun metal non- return valve of approved quality (screwed end) :65 mm nominal boreHorizontal
91Providing and fixing gun metal non- return valve of approved quality (screwed end) :80 mm nominal boreHorizontal
92Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
93Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore
94Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore
95Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore
96Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
97Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
98Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
99Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides
100Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
101Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
102Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
103Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
104Brick work with common burnt clay non modular bricks of class designation 3.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
105Brick work with common burnt clay non modular bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
106Masonry work with Porbandar Stone/ Bela Stone/ Wankaner Stone in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) all complete as per direction & satisfaction of Engineer In-Charge
107Masonry work with Porbandar Stone/ Bela Stone/ Wankaner Stone in superstructure above plinth level in:Cement mortar 1:4 (1 cement : 4 coarse sand) all complete as per direction & satisfaction of Engineer In-Charge
108Brick work with non modular fly ash bricks of class designation 5 average compressive strength at level up to floor V level in :Cement mortar 1:4 (1 cement : 4 coarse sand)
109Providing and fixing 15 mm thick prepolished, machine cut Granite stone slab of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges, as required, to give high gloss finish etc. complete at all levels.
110Providing and fixing SS Aldrop of size 250mm of approved finish, with nuts and screws etc. complete.
111Providing and fixing SS tower bolts of approved finish, with necessary screws etc. complete :200 mm
112Providing and fixing aluminium composite panel (ACP Sheet) of 4.0mm thickness in cladding, partition etc. all complete as per the directions & satisfaction of Engineer-in-charge .
113Providing and fixing Circular/ Hexagonal/octagonal metallic sheet box for holding ceiling fan clamp, of dia. of approx. 140 mm, with clamp of bent bar all complete as per direction & satisfaction of Engineer In-Charge
114Providing & fixing fly proof Stainless steel wire gauze to windows, clerestory windows, doors etc. all complete as per direction & satisfaction of Engineer In-Charge.
115Grouting the joints of tiles, using epoxy grout mix with coated filler of desired shade, including filling / grouting and finishing, all complete as per direction & satisfaction of Engineer-in-charge.
116Providing and laying 15 mm thick, flamed finish Granite stone slab in required design, patterns, size, location, colour, shade & texture all complete as per the drawings over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
117Providing and fixing precoated plain (without corrugation) galvanised iron profile sheets (size, shape as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
118Providing and erecting 2.4 metre high temporary barricading of Galvanised iron profile sheet with additional 450mm x 450mm MS holding arrangement at approx. interval of 3.0 metre, for and including 600mm dia concertina coil (the coil to be placed as per the requirement and as directed by Engineer In-Charge) at site; with suitable MS support and bracing. The sheet shall be fixed with suitable MS section by suitable welding/riveting. Suitable arrangement shall be made to fix the barricading to avoid from overturning. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes reflective signs, marking, flags, caution tape etc. as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer-in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work).
119Providing and fixing Stainless Steel kitchen sink of approx. size of 470x420 mm bowl depth 178 mm including making good the cutting etc. wherever required, all complete as per direction and satisfaction of Engineer In-Charge.
120Providing and fixing beveled edge mirror of superior glass (of approved quality) with SS stud etc. all complete as per direction and satisfaction of Engineer In-Charge.
121Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling as required etc.External work100 mm dia nominal bore
122Providing and fixing ball valve of approved quality all complete as per direction & satisfaction of Engineer In-charge.50 mm dia.
123Providing and fixing ball valve of approved quality all complete as per direction & satisfaction of Engineer In-charge.65 mm dia.
124Providing and fixing ball valve of approved quality all complete as per direction & satisfaction of Engineer In-charge.80 mm dia.
125Providing and fixing ball valve of approved quality all complete as per direction & satisfaction of Engineer In-charge.100 mm dia.
126Providing and fixing butterfly valve of approved quality , all complete as per direction & satisfaction of Engineer In-charge.65 mm dia.
127Providing and fixing butterfly valve of approved quality , all complete as per direction & satisfaction of Engineer In-charge.100 mm dia.
128Providing and fixing 25 mm dia. CPVC ball valve of approved quality all complete as per direction and satisfaction of Engineer In-Charge.
129Providing and fixing Non- return valve of approved quality all complete as per direction & satisfaction of Engineer In-charge.100 mm dia.
130Providing and fixing Pillar cock Jaquar OPP-CHR-15001PM or approved equivalent , all complete as per direction and satisfaction of Engineer In-Charge.
131Providing and fixing 3 mm ACP (Aluminium Composite Panel) sheet of approved, quality, make & shade, in panelling fixed in aluminum doors, windows shutters and partition frames etc. with C.P. brass / stainless steel screws etc. complete as per drawings and directions of engineer-in-charge.
132Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacture, including providing and fixing Glass connectors (SS 304) at top and bottom and other fixing arrangements as required all complete as per direction of Engineer-in-charge. (Connectors to be paid separately)
133Providing & fixing 8 mm thick Calcium Silicate based modular false ceiling (of approx. size of 2' x 2') at all height including providing & fixing of framework made of special section, fixed to the hangers of required length & size and fixed in a direction perpendicular to intermediate section with connecting clip with G.I wire at every junction, including fixing perimeter section, the perimeter of ceiling fixed to wall/ partitions including fixing of Calcium Silicate Board to ceiling section and perimeter channels including jointing & finishing to a flush finish of tapered and square edges of the board, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge.
134Providing and pasting UV-Printed Glass Film of Garware, 3M, Avery Dennison, LG Hausys make or as approved by Engineer In-Charge displaying the approved patterns/ pictures etc. including cleaning the glass surface, all complete as per direction & satisfaction of Engineer In-Charge.
135Providing and pasting Frosted Glass Film of Garware, 3M, Avery Dennison, LG Hausys make or as approved by Engineer In-Charge of approved pattern etc. including cleaning the glass surface, all complete as per direction & satisfaction of Engineer In-Charge.
136Providing and pasting Suncontrol Glass Film of Garware, 3M, Avery Dennison, LG Hausys make or as approved by Engineer In-Charge of approved shade etc. including cleaning the glass surface, all complete as per direction & satisfaction of Engineer In-Charge.
137Providing and fixing at Window Roller blinds of approved shade & texture of Vista make or as approved by Engineer In-Charge, all complete as per direction & satisfaction of Engineer In-Charge.
138Providing Structural design & drawing of the following structure, as per relevant IS Codes and other relevant Code(s) of Practice, from an experienced Structural Consultant/ Consultancy Firm, (The credentials of the Consultant to be submitted to the Engineer In-Charge, in advance for finalization of the Consultant) after making required site investigation by the Consultant / Consultancy Firm, and getting the drawing and design of the structure \\"Structural Proof checked & Vetted\\" from a reputed Engineering College e.g. IIT /NIT or as approved by Engineer In-Charge, (Three sets of A2 size of good for Construction duly vetted Drawing to be submitted to the Office). all complete as per direction & satisfaction of Engineer In-charge.:-1. Staff Canteen2. Frisking Room at VIP Gate3. MS Shed Structure at VIP Gate4. Operational Boundary Wall at VIP Gate5. Store at the back of MT Section.(Each of the above five structures will be considered as pro-rata of 0.20 unit for payment purpose)(The Submission of the vetted drawing has to be done withing 25 days of the award of the work or as per direction & satisfaction of Engineer-In-Charge)
139Deduct for taking away Mild Steel items etc. all complete as as direction & satisfaction of Engineer In-Charge
140Supply of 2ft X 2ft Recess/Surface mounted LED luminaries having minimum 3600 lumen output complete with electronic driver, made out of powder coated CRCA/Aluminium housing with opal/acrylic diffuser suitable to operate on 230V, 50Hz single phase AC supply etc, complete as per specifications. (Make : HAVELLS or equivalent approved make)
141Supply of 18-22 W Surface mounted/Suspended type LED batten light fixture with extruded polycarbonate and opal/acrylic diffuser, having 100 lumens/watt suitable to operate on 230V, 50Hz single phase AC supply etc, as per specifications.
142Supply of electric ceiling fans 1200 mm sweep, capacitor type with double ball bearing complete with down rod, shackles, blades but without speed regulator, having 3 star energy efficient label certified by Bureau of Energy Efficiency (BEE) suitable for operation 230/240V, 50Hz, single phase AC supply. Confirming to IS - 374 / 1979 with amendments 1,2,3 & 4 class -I and provided with functional insulation etc. as required.(Make: Havells, Model: ES-40 Three Star or Equivalent Approved make).
143Supply of Exhaust fan of 300 mm sweep, 900 RPM, provided with Robust Motor for continuous running of fan including all accessories and suitable to operate on single phase, 230 V, 50 Hz A.C. supply.
144Supply of 400mm sweep more than four star wall fan suitable for the operation on 230V, 50 Hz AC supply with all accessories complete as required & as specified.
145Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required - Group C
146Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.-- Group C
147Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.a) 2 X 2.5 sq.mm + 1 X 2.5 sq. mm earth wire
148Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.b) 2 x 4 Sq. mm +1 x 4 Sq.mm earth Wire
149Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.c) 4 x 6 sq. mm +2 x6 Sq. mm earth Wire
150Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connection etc as required.
151Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
152Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
153Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
154Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
155Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (The make and Model should be same as those for BOQ item no. 1)5/6 amps switch
156Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (The make and Model should be same as those for BOQ item no. 1)3 pin 5/6 amp socket outlet
157Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (The make and Model should be same as those for BOQ item no. 1)Telephone socket outlet
158Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (The make and Model should be same as those for BOQ item no. 1)TV antenna socket outlet
159Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required.
160Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/recessed steel/PVC conduit as required.
161Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
162Supplying and fixing of 20 mm dia steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
163Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
164Supplying and fixing stepped type electronic fan regulator in the existing modular plate switch box including connections but excluding modular plate as required.
165Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
166Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connections, testing, commissioning etc. & earthing as required.
167Extra for fixing the louvers/shutters complete with for exhaust fans of all sizes.
168Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
169Supplying and fixing following way, Verticle type three pole and neutral, sheet steel, IP43 MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (8 + 12), Double door
170Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door
171Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 Way, Double door
172Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, Single pole \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
173Supplying and fixing 40 Amps amps rating, 240/415 volts, \\"C\\" curve, Double Pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
174Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63Amps
175Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amps
176Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
177Supplying and fixing single pole blanking plate in the existing MCB DB complete as required.
178Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part II 2023. The system shall be able to operate up to 50 °C (outdoor ambient temperature).2.0 TR with 5 Star BEE Rating
179Providing and fixing of refrigerant piping, cabling, insulating with foam between indoor and outdoor units of 1.5 to 2.0 TR etc. as required.
180Supply and Installation of ducted wall mount chimney with push button control pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
181Supply and fixing of flexible Aluminium pipe of 5.5-6 inch dia with suitable m.s./ GI clamp and accessories coneecting to wall mount chimney etc. as required.
182Supply of 4 x 10 sqmm size XLPE insulated, PVC sheathed, Aluminium conductor armoured power cable of 1.1 KV grade confirming to IS - 7098 PART- I /IS 1554 part 1 with upto date amended etc. complete as required.
183Supply of 4 x 25 sqmm size XLPE insulated, PVC sheathed, Aluminium conductor armoured power cable of 1.1 KV grade confirming to IS - 7098 PART- I /IS 1554 part 1 with upto date amended etc. complete as required.
184Supply of 4 x 35 sqmm size XLPE insulated, PVC sheathed, Aluminium conductor armoured power cable of 1.1 KV grade confirming to IS - 7098 PART- I /IS 1554 part 1 with upto date amended etc. complete as required.
185Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing HDPE/ RCC/ HUME/ METAL pipe as required.A) upto 35 sqmm
186Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
187Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
188Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.4 x10 Sq mm
189Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.4C x 25 Sqmm
190Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.4C x 35 Sqmm
191Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
192Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
193Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe From earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
194Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
195Supply of a stainless-steel water cooler with 120-liter storage capacity, 60 LPH cooling capacity, built-in 50 LPH RO system with UV, and two manual taps (cold and ambient), complete with all required accessories etc. complete as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57394855
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 2.25 Crore
LAST DATE 28-09-2026
Authority
Authority Name Airports Authority Of India
Work Description Tender for Construction Of Staff Canteen; Frisking Room, Shed & Boundary Wall At Vip Gate; Store, Parking Shed & Other Miscellaneous Work At Rajkot International Airport (Sh: Civil & Electrical Works).
Basic Detail
Tender No AAI/RIA/SM(ENGG-C)/SC/26-27
Bidding Type Tender
Location
City Rajkot
State Gujarat
Key Dates
Publish Date 07 Sep 2026
Submission Date 28 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 2.25 Crore
Tender Fee 1180
EMD 6.75 Lakhs
Exemption Not Available
Document List
67bb1efe-7603-4f85-a086-f9acb1ea17f0.html
BOQ_338348.xls
Tenderdocument1.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

67bb1efe-7603-4f85-a086-f9acb1ea17f0.html

xls

BOQ_338348.xls

pdf

Tenderdocument1.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender