Tender For Repair, Replacement And Maintenance Of Unserviceable Perimeter Lights, Street Lights, Cable Junction Boxes, Street Light Brackets, Poles, Cables, Painting Of Poles And Other Misc Street Lighting Works At Smq, Hq Area And Mes Complex At Af
Tender Overview
Project Description
Tender for Repair, Replacement And Maintenance Of Unserviceable Perimeter Lights, Street Lights, Cable Junction Boxes, Street Light Brackets, Poles, Cables, Painting Of Poles And Other Misc Street Lighting Works At Smq, Hq Area And Mes Complex At Af Stn Digaru.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down of LT cable XLPE insulated UG cable of sizes 10 Sqmm to 95 sqmm complete all as specified and as directed. Note:- Excavation, returning filling, removing paid seperately under relevent item. |
| 2 | Supply, laying testing and commissoning of LT UG cable, XLPE insulated PVC bedded, galvanised steel strip or wire armoured heavy duty with electric power cable with stranded aluminium 1100 volts grade, laid in trenches/duct/on pole incl all necessary fixing arrangements such as lugs, glands and termination joints etc.of cros sectional area 10 sqmm 4.0 core complete all as specified and directed. |
| 3 | All as per Sl item No. 02.00 here in above but of size 16 Sqmm 4.0 core. |
| 4 | All as per Sl item No. 02.00 here in above but of size 25 Sqmm 4.0 core. |
| 5 | All as per Sl item No. 02.00 here in above but of size 35 Sqmm 3.5 core. |
| 6 | All as per Sl item No. 02.00 here in above but of size 70 Sqmm 3.5 core. |
| 7 | Relaying of LT UG Cable of size 10 to 35 Sqmm 3.5/4.0 core obtained from Sl item No. 01.00 above complete all as specified and directed. Note: Excavation, returning filling, removing paid seperately under relevent item. |
| 8 | Relaying of LT UG Cable of size 50 Sqmm 3.5 core obtained from Sl item No. 01.00 above complete all as specified and directed. Note: Excavation, returning filling, removing paid seperately under relevent item. |
| 9 | Relaying of LT UG Cable of size 70 Sqmm 3.5 core obtained from Sl item No. 01.00 above complete all as specified and directed. Note: Excavation, returning filling, removing paid seperately under relevent item. |
| 10 | Relaying of LT UG Cable of size 95 Sqmm 3.5 core obtained from Sl item No. 01.00 above complete all as specified and directed. Note: Excavation, returning filling, removing paid seperately under relevent item. |
| 11 | Excavation in trenches in any type of soil (soft/loose soil) exc 1.5mtr but n.exc 3 mtr in dept Pole foundation/GI pipes for trenches, complete all as specified and directed. |
| 12 | Excavation in trenches in any type of soil (soft/loose soil) not exceeding 1.5 metre wide and not exceeding 1.5m in depth LT under ground cables/GI pipes for trenches, complete all as specified and directed. |
| 13 | Returning, filling in, including spreading watering and well ramming in layers not exc 25cm in layers, complete all as specified and directed. |
| 14 | Removal of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed. |
| 15 | M&L for sand coushioning to UG cables (8 cm deep before laying of cables and 15 cm over the cable) including spreading, levelling, well ramming in layers complete all as specified and as directed. NOTE:- punned thickness of 18cm only will be considered for payment purpose. |
| 16 | Supply and fix sub class 'B' bricks of standard size for cable protection in trenches including taking down old unsv one complete all as specified and directed. |
| 17 | Supply and fixing GI tubing light grade 15 mm dia for protection pipe for fixing along the pole with necessary MS clamps of suitable size not less than 25X5mm , nut bolt washers including taking down old unsv ones complete all as specified and directed. |
| 18 | Supply and fixing GI tubing light grade 40 mm dia for protection of cable on pole, under road crossing or across drain or floor/ wall complete including taking out old unserviceable ones complete all as specified and as directed. |
| 19 | Supply and fixing GI tubing light grade 50 mm dia for protection of cable on pole, under road crossing or across drain or floor/wall complete incliding taking out old unserviceable ones complete all as specified and as directed. |
| 20 | Supply and fixing GI tubing light grade 80 mm dia for protection of cable on pole , under road crossing or across drain, or floor/wall complete incliding taking out old unserviceable ones complete all as specified and directed. |
| 21 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in base of pole foundation including breaking existing PCC and removing from site complete all as specified and as directed. |
| 22 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in pole foundation and coping of pole above GL including breaking existing PCC and removing from site complete all as specified and as directed. |
| 23 | S&F street light junction box made from CPRI approved factory having size 200 (Width) x 160 (Depth) x 250 (Height) mm (minimum dimensions) made out of 2.00 mm thick CRCA sheet, duly powder coated of approved shade over a coat of red oxide primer both internally and externally, with rain shed all side except back side, comprising of 02 nos copper bus-bar of size 20 x 4 mm mounted on suitable size spacer insulators, necessary cable entry / exit holes for upto 35 sqmm cables, nut-bolts, MS clamps of suitable size for fixing including dismantling old unsv ones complete all as specified & as directed. |
| 24 | S&F 6 KW, three phase, astronomical time switch for street light control panel with and including digital timer switch for automatic switching on / off street light as per set time through programmable astronomical switch, 63A TP power contactor, 63A TPN MCB, wall / floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 61439 & 60529, in-built- short circuit protection, locking arrangement with padlock and panel lock including dismentling old unserviceable one complete all as specified and directed. |
| 25 | M&L for PVC Insulated Weather proof multicore FRLS PVC sheathed multistranded cables with bright annealed copper conductor of size 1.5 sqmm 2 core for connection of light to pole box including taking down old unsv one completed all as specified and directed. |
| 26 | S&F LED street light fitting 60 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosin resistant including thermal management in multiple optics complete with IP 66 protection including with fixing arrangement and dismentling old unsv one complete all as specified and directed. |
| 27 | All as per Sl item No. 26.00 as above but 90 watt LED street light fitting. |
| 28 | S&F Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 100 watt, Tempered protective toughened glass with IP66, IK07, System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, , Operating Voltage range 140 V - 270 V including fixing arrangement and dismentling old unsv one complete all as specified and directed. |
| 29 | M & L for straight through joint kit (Heat shrink joint kit) for PVC insulated and sheathed aluminium conductor cable of size 10-16 Sqmm, 3.5/4 core and testing after jointing the cable including taking down old unsv one complete all as specified and directed. |
| 30 | All as per Sl item No. 29.00 here in above but of size 25-50 Sqmm 3.5 core. |
| 31 | All as per Sl item No. 29.00 here in above but of size 70-120 Sqmm 3.5 core. |
| 32 | M&L for preparation of painting for 9 m long old steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of aluminium paint on complete height of the pole and applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with multi colour strips as per the colour code including writting pole No with synthetic enamel paint of size not lessthan 2\\" within 6\\" dia circle. complete all as specified and directed.Note:- Qty of letters for writting of pole No should not exceed 06 Nos. |
| 33 | M&L for dismantling of steel/PCC/RCC poles, struts, accessroies complete all as specified and directed. |
| 34 | M&L for steel tubular swaged poles complte with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410-SP-31 (9.0 meter long) all as specified and directed.Note : Exc, RFR and PCC work shall be measured and paid for seperately. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender