Defence Statutory Bodies & Commissions/Committees Closing in 7 days TDR #57393585

Tender For Repair And Maintenance Of Mes Power House / Sub Station & Water Supply Installations, Electric / Water Supply Equipments & Repair Of Leakage Seepage And Other B/R Connected Works At Pal Ur Mil Station Under Ge Pal Ur

Issued by Statutory Bodies & Commissions/Committees · Kangra, Himachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Sep 2026
7 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kangra → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Mes Power House / Sub Station & Water Supply Installations, Electric / Water Supply Equipments & Repair Of Leakage Seepage And Other B/R Connected Works At Pal Ur Mil Station Under Ge Pal Ur

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 16-Sep-2026 Amendment Other 28-Sep-2026

BOQ

Name of Work:- Repair and maintenance of MES Power House / Sub Station & water supply installations, Electric / water supply equipments & repair of leakage seepage and other B/R connected works at Pal ur Mil Station under GE Pal ur
Sl. No. Item Description
1Excavation in trenches, not exceeding 1.5m wide and not exc 1.5m in depth and getting out in any type of soil, for laying cable complete all as specified and as directed.
2Returning, filling in including spreading, levelling watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested complete all as specified and as directed.
3Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
4M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and as directed.
5M&L for laying in trenches burnt brick sub class 'B' for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified and as directed.
6Taking out from trenches / floors/road/wall/pipe LT cable of any size/description and removing from site incl making good the disturbed surfaces to match with existing surface complete all as specified and as directed.
7Supply & laying of LT UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 95 Sqmm 3.5 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed.Note : (i) Cable joint shall be measured and paid separately.)
8All as per item No. 7 above but of cross sectional area 70 Sqmm, 3.5 core.complete all as specified and as directed.
9All as per item No. 7 above but of cross sectional area 50 Sqmm, 3.5 core.complete all as specified and as directed.
10All as per item No. 7 above but of cross sectional area 35 Sqmm, 3.5 core.complete all as specified and as directed.
11All as per item No. 7 above but of cross sectional area 25 Sqmm, 3.5 core.complete all as specified and as directed.
12All as per item No. 7 above but of cross sectional area 16 Sqmm, 4 core,complete all as specified and as directed.
13M&L Checking of Earth Resistance of GI/Copper/Chemical/Normal Earthing and maintaining the resistance as required Earth Resistance Tester will be provided by the Contractor and will be recorded in Register, same will be put up to the Engineer-in-Charge. Contractor will be responsible for pouring of water in the Earth Pits at his own arrangement with Water Tanker, etc. However, Water will be provided by the Department, complete all as specified and as directed.
14Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including 20x3mm GI flat earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m. Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-Charge.Note :- (i) PCC chamber shall be constructed at least 1.5 metre away from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of GE.
15All as per item Srl No. 14 Above but by using GI wire 4mm dia as earth lead & 15mm bore medium grade GI pipe for protection of earth wire from plate to main switch board complete all as specified and as directed.
16Material and labour for Earthing complete with copper plate 60x60cm x3.15mm thick electrode buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including 20x3mm copper strip as earthing lead by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m. Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of GE.
17Supply, Installation and commissioning and testing of CPRI approved LT panel cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, with canopy sloped top projected, floor mounted outdoor type factory fabricated duly powder coated inside and out side, outer cover made out of 2.8 mm thick CRCA sheet, internal cover and partition made out of 2.8 mm thick CRCA sheet with angle iton 50mm x 50mm x 6mm covered from all side with front and back openable, weather proof including suitable rating aluminium busbar for 3 phase 4 wire system, wiring with suitable size copper cable and embeded in brickwork in CM 1:4 with suitable foundation for fixing panel of required size in ground with nuts, bolts and washers etc. complete comprising of following including taking out the old unserviceable panel complete all as specified and as directed. :-(a) MCCB 100 Amps, 16KA 4 pole -1 No (As Incomer)(b) MCCB 63 Amps ,16KA 4 Poles - 2 No (AsOutgoing)(b) Aluminium busbar 160 Amps TPN- 04 Nos(c) Digital voltmeter 0-500 Volts with selecter switch - 01 Nos(d) Digital Amp Meter 0-500 Amp with selector switch & CT 01 No(e) Indicator lamp LED type (R, Y, B) complete with bakelite fuse fitting - 01 Set(f) Cable entry gland and two no earthing terminal
18Supply, install, testing & commissioning of CPRI approved LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire , 50 Hz , AC supply system having busbar chamber with Aluminium bus bars duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators. The panel shall be factory made, double door, made out of 3.15 mm thick MS Sheet (CRCA) totally enclosed dust, vermin & rust proof front operated, front & rear opening with locking arrangement fixed with MS angle iron frame of sie 40X40X6 mm and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable etc all as directed at site and comprising of the following:-(a) MCCB 250 A, 4P, 415 Volts AC supply, thermal magnetic release type 36 KA-01 No(b) MCCB 100A, 4P, 415 Volt 10 KA thermal magnetic relase type -02 Nos.(c) MCCB 63A, 4P, 415 Volt 10 KA thermal magnetic relase type -01 Nos.(d) Timelite -110 A 3 Pole, 230 V Digital time switch Make : indoasian 01 Nos(e) On load change over switch 250Amp inbuilt with panel -01 Nos(f) Panel mounted multi function meter for measuring Voltage (0-500 Volts). Current (0-100 Amps) and frequency-01 No(g) RYB neon indicating lamp panel mounting type (Set of three) - 01 No(h) Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses(j) Cable entries gland and two no earthing terminal
19Supply,install,testing and commissioning of CPRI approved factory made LT feeder piller box outdoor type with double doors provided with locking arrangements dust, vermin and water proof made out of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2mm thick CRCA sheet powder coated with back door detachable fixed with nuts, bolts and washers and front doors openable type fitted with hinges and knobs/locks. Panel is to be placed on angle (size 50x50x6mm) frame duly painted with two coats of synthetic enamel paint over a coat of primer to the portion visible to eye supported on 04 legs 750mm long each duly 450 mm grouted in PCC blocks of type 1:2:4 type B-1and 300mm above ground level for entry of cables suitable for 3-phase, 4-wire, 50Hz,415 volts,with and including necessary incoming and out going cable connection with proper size aluminium lugs, nut bolts etc including the following complete all as specified and as directed:-Main Supply) - 01 Nos(a) MCCB 400 Amp,4P, 36KA (I/C for 25 KA, 3 Pole (OG) 01 Nos(b) MCCB, 125A, MCCB, 100A, 25 KA, 3 Pole 3Nos(c) [d] LED type AC 220V Phase Indicators RYB , - 02 Set(e ) Aluminium strip bus bars with heat shrinkable type colour code PVC insulation sleeves 400 Amps capacity TPN mounted on epoxy insulators - 02Set Voltmeter, Amper meter,indicator lamps , CT coi 100/5-01 set.(v) Aluminium Bus bar 4 strip -400 Amps capacity.(vi) Internal wiring of panel board with copper cable single core of sutable size and incl 03 Nos bakelite control fuses.[g] Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board doorNote :- The contractor will approved the panel drawing before incorporate in the work and should be CPRI approved
20S& F LT cubical panel outdoor kiosk type with Aluminium bus bar 3 pin 4 wire metering and comprising of following :- (i) MCCB TPN63A - 01 No for I/C (ii) MCCB SPN 63 Amp -01 for O/G (iii) MCCB SPN 32 Amp -02 Nos complete all as specified and as directed.
21Supply and mounting on wall with necessary fixing arrangement sign board 3.00 Meter length X 1.00 Meter width X 0.30 Meter depth fabricated with aluminium frame with acrylic sheet duly written Sub Stn and Plant Name as diretd by Engr -in Charge with bold letters reflective tape on acrylic sheet as approved by Engr -in-Charge including 02 Nos, 4 feet 20 watts LED Tube light fitting wiring with 1.5 sqmm size copper conductor and making connections complete all as specified and as directed.
22S&F Air termination vertical type, Single pointed made with 12mm dia 300mm long aluminium rod including necessary fixing arrangements with aluminium bolts, nuts, lead washers etc, complete all as specified and as directed.
23Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and as directed.
24S&F Horizontal /down conductors, aluminium strip of size 25 x 3.15mm and incl epoxy insulator bus bar type 40mm thick at an interval of 60 cm apart for lightening protection on roof and for down conductors, including all fixing arrangement and aluminium nut , bolt & washers complete all as per IS-2309-1989 and testing all as specified.Note :- i) Aluminium strip shall be jointed with rivets (minimum 4 Nos) .
25S&F Galvanised from strip of size 32 x 6mm from earth pit to test point provided all around the bldg for lightening protection laid in trenches/fixed to walls on epoxy insulators with screws etc and connecting up complete all as specified and as directed.
26M&L for replacement of Arrester clamp for Lightening Arrester of size 16mm made out brass complete all as specified and as directed
27Supply & Fixing porcelain insulator of required size not exceeding than 10 cm long with two nos hole each on both end for fixing properly with fastner, nuts & bolts on wall & roof of buildings for separated earthing stirp from building all as required at site & directed by GE.
28Demolition of concrete (coping of steel /PCC pole/Road) of any description and in any position, complete all as specified and as directed.
29M&L for Plain Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles,earth pit ,including provision of necessary form work, finishing even and smooth without using extra cement complete all as specified and as directed.
30M & L Plain Cement Concrete 1:3:6 type C2 using 40mm graded stone aggregate as in road cutting filling, foundation, fencing post , struts etc. complete all as specified and as directed.
31Supply and fixing in replacement of MCCB 400 Amp rating,4-pole 415V, 50 Hz breaking capacity 36 KA, Adjustable & fixed magnetic setting type.complete all as specified and as directed.
32Supply and fixing in replacement of MCCB 250 Amp rating,4-pole 415V, 50 Hz breaking capacity 36 KA, Adjustable & fixed magnetic setting type.complete all as specified and as directed.
33Supply and fixing in replacement of MCCB 200 Amp rating,4-pole 415V, 50 Hz breaking capacity 25 KA, Adjustable & fixed magnetic setting type.complete all as specified and as directed.
34Supply and fixing in replacement of MCCB 125 Amp rating,4-pole 415V, 50 Hz breaking capacity 16 KA, Adjustable & fixed magnetic setting type.complete all as specified and as directed.
35Supply and fixing in replacement of MCCB 160 Amp rating,4-pole 415V, 50 Hz breaking capacity 25 KA, Adjustable & fixed magnetic setting type.complete all as specified and as directed.
36Supply and connect twin core PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm with complete cable connection on street light fitting to looping box complete all as specified and directed.
37Supply and fix MS Chequred plate 6.0 mm thick sheet having with Hook, and painting it with one coat of black paint suitable for cable duct cover in pump house and sub stn complete all as specified and directed
38Taking out old/bent/straight/ tilted LT pole any capacity, any size, any type poles after breaking the PCCcomplete all as specified and as directed..(The rate quoted shall include the cost of excavation,dismantling of conductor, cross-arms and insulators)
39S&F steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolt, nut and screws as specified 410 SP-31 (9 mter long) including taking down old damaged pole of any type and size, including one coat of red-oxide zinc chrome primer and two coats aluminium paint on surfaces, exposed to view and making 30cm wide strips (Total 5 Nos) with yellow and black paint alternately on external surface, above PCC benching including with writing of pole No with letters/figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm after painting complete all as specified and directed.
40M&L Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete for stays foundation and platform for transformer installation complete all as specified and directed.
41M&L Plain cement concrete 1:2:4, Type B-1 by using 20 mm graded granite stone aggregate in coping including necessary form work and finishing exposed surfaces fair & even complete all as specified and as directed.
42M&L Plain cement concrete 1:4:8, Type D-2 by using 40 mm graded granite stone aggregate for base (bottom of pit for Bed Concrete) including necessary form work and finishing exposed surfaces fair & even complete all as specified and as directed.
43Supply, fixing & testing 45W LED street light fitting IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens embedded PC cover complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and as directed. including taking down . Note : GI pipe bracket and clamps if required shall be measured and paid separately.
44S&F 40 mm dia GI light grade pipe 1.2 m long with bracket bent to shape by cutting & welding as required & directed and fixed to pole with two No,s of FI clamps 40x5 mm to be tightened with bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
45S&F PVC conduit 20 mm dia from junction box to security light fitting including 2.5 Sqmm copper cable two run Pahse and nutral fixing with clamps complete all as specified and directed
46Supply & Fixing repairs cable junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 205x255x112 mm and suitable for LT under ground cable any size/capacity including bracing clamp,bolts,nuts & washers.complete all as specified and as directed.
47Supply and laying GI pipe \\"light Grade\\" in trenches/under floors or roads or along the pole for protection of cables or fixing of air termination of 40 mm bore complete all as specified and as directed.
48M&L GI pipe Light grade with all fittings complete laid in trenches/fixed on pole with suitable clamp all as specified for 50 mm bore of pipe for protection of UG cable.complete all as specified and as directed.
49Supply and fixing Double Wall Corrugated (DWC) pipe of size 63mm outer dia and 50mm inner dia confirming to IS:14930 Part-II including necessary pipe fittings such as couplers, end caps, bend etc. including fixed to wall/roof /pole/trench as required with suitable clamps for cable protection complete all as specified and directed.
50M&L for HDPE Double Wall Corrugated pipe of size 90mm outer dia and 75mm inner dia confirming to IS:14930 Part-II including necessary pipe fittings such as couplers, end caps, bend etc. including fixed to wall/roof /pole/trench as required with suitable clamps for cable protection complete all as specified and directed.
51M&L for Trimming /chopping and cutting of branches in each tree of any girth which are coming across the over head line LT up to 3 m both sides from the centre of conductor as required and removing the same from site of work complete all as specified and as directed.
52Material and labour for removal green vegetation and dressing around the sub stn bldg/2/4 pole structure / plinth/copping/PCC hardstanding up to 1.5 mtr etc including disposal of vegitation /material up to 50 mtr distance from the site and levelling/surfacing the ground complete all as specified and as directed.
53Dismantling U/S any size of cross arms from pole /structures and fencing post,struts etc. complete all as specified and as directed.
54M&L for work as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.
55M&L for to prevent leakage of water pipe line at various places including required material by welding of flanged/socket/collar or at the joint of sluice valve/air release/none returne valve or damaged pipe line etc including excavation/returning and filling complete all as specified and as directed.
56M&L for masonry valve pit of size 90X90X90cm (Internal dimensions of chamber) built in Cement Mortar 1:6, Plain cement concrete, M-10 (Nominal mix) type C-2 (using 40 mm graded crushed stone aggregates) as in foundation filling and mass concreting and including 15mm thick plastering internally with cement mortar 1:6 and flush pointing externally as the work proceeds in same mortar and Plain cement concrete, M-15 (Nominal mix), type B-1, (using 20mm graded crushed stone aggregates) as in coping complete, 3.15 mm thick MS sheet cover, handle, locking arrangement including provision of angle iron frame 40x40x6 mm for cover and 2 foot steps made out of MS 16 mm dia round bars, wash out pipe made out of GI pipe medium grade, 50 mm dia upto 1 metre length, earth work in any type of soil including removal to a distance not exceeding 50 metre and painting steel surface with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.
57All as per description of ser item No 56 above but of size 120 x 120x120cm complete all as specified and as directed.
58Supply and fixing LED Solar street light fitting 24 Watt including galvanised steel pole & in built lithium ion battery, solar panel, charge controller with dusk down sensor complete. (Note :- rates are included to excavation, Earth work,PCC work, GI pipe 50 mm dia (as required at site) steel structure for fixing of Solar panel & Light complete all as specified and as directed.
59Supply and install in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, 200W LED complete all as specified and as directed.
60Supplying and fixing on existing sign board a layer of any colour sticker sheet as background and computer composed sticker letter , figure, arrow etc fixed on the background sheet as per the matter given for displaying the road sign boards, directions signs etc including removing existing letter ,direction,arrow etc from the board complete all as specified and directed by Engr in Charge Letter, symbols, borders as per direction on Engr in charge etc. Existing aluminium Sheet work inc structural framework to be repaired and re painted with two or more coats of synthetic enamel paint and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete all as specified and as directed.
61Preparing surfaces of Two pole structure including cross arms, channels, clamps etc by scrapping old paints and applying two coats of aluminium paint and Pole No in black paint etc complete all as specified and as directed.
62Unbinding of the ACSR conductor form insulator on pole Pruning, tree branches 2 mtr all around conductor and, restringing ACSR conductor, tightening of OH Line, binding to the insulators using required size of aluminium binding wire complete all as specified and as directed.
63Excavation in post holes in hard/dence soil (for similar holes) each n.exc 0.5 cum, getting out, returning filling in and remming each of broken rubble mixed with earth aroundin layers not exc 25cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified and as directed.
64Cement concrete PCC 1:2:4 type B2 using 40mm graded crushed stone agg as in fdn/ sub base of posts complete all as specified and as directed.
65S&F Mild steel work in posts and struts in fencing including cutting tops to shape as directed, drilling holes notching for wire etc, flat iron fillets for securing wire mesh/chain link fencing including all necessary welding, drilling, bolting or riveting etc and similar work and providing MS flat for welding of GI mesh to posts or struts complete all as specified and as directed.
66S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, Diameter of neck is 11 to 15 mm, n exc 5cm long complete all as specified and as directed.
67Supply and fixing mild steel round bars 10 mm dia and over, cut to length, bent to shape required including cranking , bending spirally for hooping for columns, hooking ends, binding with and including mild steel wire (annealed) not less than 0.9mm dia, or securing with clips of Fe-410W(Gde.E250) quality -A or Fe290(Gde-E-165) complete all as specified and as directed.
68Dismantling fencing wire mesh, any type complete all as specified and as directed.
69Supply only chain link fencing 4 mm dia of galvanised steel wire 100mm x 100mm made up into matteress or cages,complete all as specified and directed
70Fixing only chain link fencing complete including line wires,any mesh,size and type to any type of standards rails ,straining bolts,etc including provision of binding wire, complete all as specified and as directed.
71S&F Cast iron sluice valve long body type, both ends flanged and drilled, of size 100 mm bore, (ISI marked) conforming to IS-14846 -2000 with pressure rating of PN-1.6 with steel spindle and iron wheel head including jointing material such as nuts, bolts, washers and rubber gasket etc, including taking down old unserviceable sluice valve complete all as specified and as directed.
72All as per ser item No. 71 Above but of size 150 mm bore, complete all as specified and as directed.
73All as per ser item No. 71 Above but of size 200 mm bore, complete all as specified and as directed.
74All as per ser item No. 71 Above but of size 250 mm bore, complete all as specified and as directed.
75Supply and fix wall mounting type panel with automatic Star delta starter suitable for 22 KW motor of appropriate size as reqd at site with overload relay range 20-32 Amps, power contactors of suitable capacity, timer range and single phase preventor, ON/OFF actuators etc with MCCB 100 Amp, 4 Pole, 25 KA as main switch including taking down old un-serviceable panel complete all as specified and as directed.
76Supply and fix MS Cover of 3.0 mm thick sheet having angle iron (50x50x6mm) with Hook, Hold fast, Hinge etc. and painting it with one coat of black paint suitable for valve pit size 90 x 90 x90 cm including taking out old un-serviceable MS cover of any type and size obtained at site complete all as specified and directed
77All as per ser No 76 Above but for of size 120 x 120 x 120 cm complete all as specified and directed.
78M&L for repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and all drop bolt complete and painting with one coat of synthetic enamel paint of approved color internally and externally complete all as specified and as directed.
79M&L for Framed work as in doors or gates of angle or other section with gusset Fe 290-W (Gde E-165) plates, rails, braces, etc., compute, drilled for fixing of steel sheeting or other covering. Doors, etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging and fixing complete all as specified and as directed.
80Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n exc. 1.50 Sqm each incl taking out hold fast.complete all as specified and as directed.
81Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exc. 1.50 Sqm but n exc. 4 Sqm each complete all as specified and as directed.
82S&F pressed steel frames made out of MS sheet 1.25 mm thick of size 105mm x 60mm for doors with one or more rebates including necessary fixing lung, hinges, lock strike plate etc. complete all as specified and as directed.
83S&F pressed steel frames for door made out of MS Sheet 1.25mm thick of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed.
84M&L Plain cement concrete 1:2:4 (Nominal mix), type B-0 (Using12.5 mm graded stone aggregates) as in filling of steel chowkats or frames, cills and hold fast etc.complete all as specified and directed.
85S&F 35 mm thick wooden flush shutters, solid core construction with block board and 9 mm plywood face panels, commercial type on both sides, complete all as specified and directed.
86S&F 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass/wire gauge etc (without sas bars)edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc size of members of shuters as specified in SSR Part-I,Section 8, clause 8.24 (a) complete all as specified and as directed.
87M&L for preparation of wooden surfaces of any description exc over 10cm with or grith and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
88S&F Stainless steel wire netting 0.56mm of nominal dia of each wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples.complete all as specified and as directed.
89M&L Anodised powder coated aluminium frame for doors, windows, ventilators with one or more rebates, including joing cleats for fixing etc complete all as specified and as directed.
90S & F Anodised aluminium window and ventilator shutters, side hung type without sash bars... (powder coating of any colour and thickness not less than 50 micron) aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1 no.)complete all as specified and as directed.
91M&L Sheet glass 4.8 mm thick ordinary quality and glazing with oil putty or fix in neoprene rubber in aluminium section any size in square exc 0.5 sqm in each pane complete all as spfd and as directed
92S&F in repair curtain rod including brackets with cut hole suitable for 20 mm dia rod fixed with screws and gutties in wall, including end caps with wall ornament and fixed to curtain rod with screws of design/shape complete all as specified and as directed.
93S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar for window/ventilator grill conforming to Fe 290,Gde-E-165, complete all as specified and directed.
94M&L for Preparing the new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over priming the surface with red oxide complete all as specified and as directed.
95S & F for floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor over all length of cover plate 140mm thick complete all as specified and directed.
96S&F butt hinges 100mm, cold rolled medium weight mild steel complete all as specified and as directed.
97S&F 125mm size, extruded aluminium alloy handles, fabricated type, anodised.complete all as specified and as directed.
98S&F 150mm long aluminium tower bolts (ISI Marked) extruded type complete all as specified and as directed.
99S&F 300mm, Mild steel spring for door, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and as directed.
100S&F 250 mm size Aluminium alloy sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and as directed.
101Dismantling of stone slabs and tiles of any description or thickness in floor,approns etc laid, bedded and pointed in any mortar complete all as specified and as directed.
102M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
103Demolition of brick work or stone /boulder masonry, built in CM, incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed.
104M&L for Brickwork with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cm (1:6) complete all as specified and as directed.
105M&L for Brickwork with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cm (1:4) as in masonry manholes, complete all as specified and directed.
106Material & labour for Rendering 10 mm thick CM 1:6 on fair faces of brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
107M & L for Rendering 15 mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
108Material & labour for Rendering 10 mm thick CM 1:4 on fair faces of brick or concrete surfaces finished even & smooth without using extra cement as in manhole, complete all as specified and directed.
109Supply only liquid water proofing compound.
110Demolition of cement concrete ( unreinforced) and in any position not otherwise specifically provided for, complete all as specified and as directed.
111M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) casted in panels as in plinth protection.complete all as specified and as directed.
112M&L Non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile over 15 mm thick screed bed in CM 1:6 including dismantling of floor tiling incl cement mortar bedding (but not backing) removing serviceable tiles to a store and rubbish off premises complete all as specified and directed.
113All as per item no.112 above item except in walls over neat cement slurry such as skirting, complete all as specified and directed.
114M&L for Glazed ceramic coloured tiles of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match with tile bedding (but not backing) removing serviceable tiles to a store and rubbish off premises all as specified and directed.
115M&L for Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement including taking down cement plaster on brick or concrete surface and description including raking out joints/Hacking for key scrubbing down with water.complete all as specified and as directed.
116M & L for Rendering 15 mm thick in two coats i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement including taking down cement plaster on brick or concrete surface and description including raking out joints/Hacking for key scrubbing down with water complete all as specified and directed. Note :- Water proofing liquid compound shall be measured and paid separately.
117M&L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour complete as per manufacturers specification two or more coats over a coat of primer over and including 2 mm thick wall care putty on new plastered surface of wall including preparation of surfaces with complete all as specified and as directed.
118Material & Labour for applying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance dirt resistance exterior paint of required shade ( Company Depot Tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces of wall complete including preparation of surfaces of wall including taking down and cleaning for refixing or removal to store, complete all as specified and directed.
119S&F Steel water tubing, 15mm bore dia, galvanised, \\"medium grade\\" with all fittings and fixtures, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc including taking down and cleaning for refixing or removal to store, complete all as specified and directed.
120S&F Steel water tubing, 20mm bore dia, galvanised, \\"medium grade\\" with all fittings and fixtures, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc including taking down and cleaning for refixing or removal to store, complete all as specified and directed.
121S&F in repair 20 mm dia gun metal ,globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
122S&F in repair bib taps 15mm bore, fancy type cromium plated with butterfly handle, screwed down, high pressure, with canutch or butterfly handle, screwed both ends for iron pipe or unions.including wall flange complete all as specified and directed.
123S&F in repair stainless steel sink, 1.00 mm thick for kitchen or laboratory , with plug waste pipe, washers, including cantilever cast iron brackets, connecting union etc. overall size 495 mm x 420 mm with bowl size 410 mm x 330 mmx160 mm, complete all as specified and directed.
124Dismantling of CI/PVC pipe 110 mm bore fixed to wall or laid in floor or trenches inculding connection all as specified and directed
125S&F PVC (SWR) pipes 110 mm bore dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
126S & F 110 mm bore PVC Bends (SWR) with access door, complete all as specified and as directed.
127Dismantling of wall & ceiling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets of any thickness, including cover fillets.complete all as specified and as directed.
128S&F Providing and fixing tiled false ceiling of size 595 x 595mm in true horizontal level suspended on interlocking gypric metal grid of hot dipped galvanised steel section (galvanized @ 120 gsm/sqm, both side inclusive) consisting of 3600mm long main 'T' runner size 24x38mm and 0.30mm thick,1200mm long cross 'T' of size 24 x 25mm and 0.30mm thick, 600mm secondary cross 'T' of size 24 x 25mm and 0.30mm thick, bottom exposed capping of width 24mm of all T-sections shall be of 0.25mm thick PPGI, wall angle is fixed along the perimeters of the ceiling to walls, partitions or columns etc with rawl plugs and wooden screws at 300mm centers Main 'T' runners are suspended from ceiling using GI slotted cleats of size 27x37x25x1.6m fixed to ceiling with 8mm dia and 45mm long Dash fasteners, 4mm GI adjustable rods with galvanised buttterfly level clips of size 85x30x0.8mm spaced at max 1200mm centre to centre along main 'T' and not more than 150mm from spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from the adjacent wall, then 1200mm long cross 'T' is interlocked between the main 'T' at 600mm center to center to form a grid of 1200x600mm and then secondary cross 'T' of length 600mm is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross tees at the ends having length more than 600mm are to be supported independently. Finally white coloured Gyproc 8mm thick Dew Drop/Granular tiles of size 595x595mm having foil on backside & PVC paper on front side wrapped around edges to be placedin grid complete all as specified and directed.
129Dismantling of floor tiling incl cement mortar bedding (but not backing) removing serviceable tiles to a store and rubbish off premises complete all as specified and directed
130M&L for 40 mm thick plain cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate ) as in floor , complete all as specified and as directed.
131100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) in base .Complete all as specified and as directed.
132Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
133M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS-15658-2006 of 60 mm thickness, M-35 Grade, complete all as specified and directed .
134All as per item No 133 except tiles, complete all as specified and directed.
135M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in coping, finished fair and even including necessary formwork complete all as specified and as directed.
136M&L for Cement concrete type C-2 1:3:6 using 40 mm graded crushed stone aggregate in surface channels and drains etc including necessary formwork.complete all as specified and as directed.
137Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends complete all as specified and as directed.
138M&L for precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded crushed stones aggregate as in cover slabs, shelves and other similar work set in CM 1:6 complete all as specified and directed.
139Dismantling of plain or corrugated steel sheeting,any gauge,thickness,including nanital or similar pattern roof covering, M&L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Sheet colour approved by GE, complete all as specified and directed.
140Dismantling of plain or corrugated steel sheeting,any gauge,thickness,including nanital or similar pattern roof covering, S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding/ridges to wall, fixed with self tapping screws complete all as specified and directed.
141Demolition of reinforcement cement concrete complete all as specified and directed.
142Use and waste of formwork to soffits of flat suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
143M&L for RCC M-15(1:2:4) nominal mix (using 20 mm graded stone aggregate) as in slabs supported on walls, beams, deck slab and in shelves and the like, complete all as specified and as directed..
144M & L for TMT bar 10 mm and over cut to length, bend to shape required including cranking, bending spirally for hoopings for coils, hooking ends and binding with ad including mild steel wire (annealed) not less than 0.9 mm dia.complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57393585
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 28-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Mes Power House / Sub Station & Water Supply Installations, Electric / Water Supply Equipments & Repair Of Leakage Seepage And Other B/R Connected Works At Pal Ur Mil Station Under Ge Pal Ur
Basic Detail
Tender No GEP-80/2026-27
Bidding Type Tender
Location
City Kangra
State Himachal Pradesh
Key Dates
Publish Date 16 Sep 2026
Submission Date 28 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 98000
Exemption Not Available
Document List
b7e5fcdb-0b01-4b06-834e-b2f13c694400.html
BOQ_883331.xls
td.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 28, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Sep 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

b7e5fcdb-0b01-4b06-834e-b2f13c694400.html

xls

BOQ_883331.xls

pdf

td.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders