Tender For Special Repairs Of Building (T-30) At installation Baaz, C Bell Bay Under Ge C Bell Bay.
Tender Value
29.50 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
13 days left
EMD
59000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs Of Building (T-30) At installation Baaz, C Bell Bay Under Ge C Bell Bay.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, light shade area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:6) etc including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 2 | M&L Rendering 10 mm thick in CM 1:4 as for backing coat of wall tiles including Virified ceramic coloured tiles 10mm thick (Square/Rectangular) polished area of each tile not exceeding 0.38 Sqm in skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match. including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 3 | M&L 75mm thick PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate as in plinth protection finished cement concrete surfaces finished even and smooth without using extra cement including making necessary construction joint filled with sealing compound including demolition of unreinforced cement concrete in ground floor and pavings n. exc. 15cm thickness (Below or above ground level) complete all as specified and directed. |
| 4 | Dismantling of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar etc Complete all as specified and directed. |
| 5 | M&L 100mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) laid in floor sub base cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for rubber moulded Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement & pigment including Screed bed or bedding layer of cement mortar 1:4, 15 mm thick for laying floor finishes complete all as specified and directed. |
| 7 | S&F for aluminium anodised snap grid frame (with minimum 15 micron uniform anodic coating) size of 600 X 600 mm consisting of Tee/ Angle section of size 40x40x2 mm thick as approved make confirming to IS-733 in frames of false ceiling including aluminium cleats with necessary CP brass / stainless steel shunk screws, aluminium perimeter angles fixed to wall wooden frame at centre to centre and fixing frame to level adjusting anchors 6mm dia GI wire hook in Tee members at 1.5 m centre to centre fixed to steel truss of roof including dismantling of Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including hangers & cover fillets/frame work etc complete all as specified and directed. |
| 8 | M&L for fixing in position 4 mm thick Non asbestos designer ceiling board of size 595 X 595 mm as per manufacturer's specification Complete all as specified and directed. |
| 9 | M & L for preparing asbestos & ceiling board surfaces and applying two coats of oil bound distemper over a coat of chalk whitening Complete all as specified and directed. |
| 10 | Dismantling plain corrugated steel sheeting any gauage thick ness including Nainital and similar pattern Complete all as specified and directed. |
| 11 | S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling plain corrugated steel sheeting any gauage thick ness including Nainital and similar pattern complete all as specified and directed. |
| 12 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws Complete all as specified and directed. (Note: Dismantling of plain steel sheet included in dismantling of above item no 15 above) |
| 13 | M&L for pre-cast cement concrete block masonary 1:3:6 type C-1 (Using 20 mm graded stone agg) with solid block exc 10 cm in width and setting in CM 1:6 etc Demolition of concrete block walling, RR masonary in cement mortar including all quoins archas pillars etc and pre-cast block walling etc complete all as specified and directed. |
| 14 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) and finish the surface even and smooth including and mixing of WPC all as per manufacturer's instructions complete all as specified and directed. |
| 15 | M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) etc including taking down cement plaster of any description including racking out joints, hacking for key and disposing of debris to a distance exc 1 Km out side MD landcomplete all as specified and directed. |
| 16 | M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) and finish the surface even and smooth including and mixing of WPC all as per manufacturer's instructions including taking down cement plaster of any description including racking out joints, hacking for key and disposing of debris to a distance exc 1 Km out side MD landcomplete all as specified and directed. |
| 17 | M&L preparation of newly or previously untreated surfaces of walls and applying three coat of plastic emulsion paint over a coat of priming plaster and including on 3 mm thick wall care putty on plastered surface complete all as specified and directed. |
| 18 | M&L for complete removal of existing treatment of walls and applying three coats of plastic emulsion paint over a coat of priming plaster and including on 3 mm thick wall care putty on plastered surface complete all as specified and directed. |
| 19 | M&L for preparation of new plastered or unplastered surfaces of wall and applying two coats of Acrylic smooth exterior paint of required shade @ 1.67 ltr/10 sqm over and including priming coat of exterior primer @ 2.20Kg/10sqm complete all as specified and directed. |
| 20 | M&L for complete removal of existing treatment of walls and applying two coats of Acrylic smooth exterior paint of required shade @ 1.67 ltr/10 sqm over and including priming coat of exterior primer @ 2.20Kg/10sqm complete all as specified and directed. |
| 21 | S&F \\"as in repair\\" Curtain rod/Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. |
| 22 | S&F \\"as in repair\\" 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washer etc Complete all as specified and directed by Engr-in-charge. |
| 23 | S&F Roof trusses ( framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing ( beam, tee, angle, channel or flat, sections) incl distance pieces cleats Fe-410-W( Gde-E-250) quaility including dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 24 | S&F Mild steel hand rails, half round or other steel section or core for hand-rail straight portion. Drilled and countersunk for balusters, running bars, for doors, balusters nosing to steps including in concrete and screwing etc. wind ties for roof including securing bolts: posts and struts in fencing including cutting tops to shape as directed, drilling, holes notching for wire, etc: flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165 including dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 25 | M&L for preparation of new steel of iron surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 26 | M&L for preparation of old surfaces of steel or iron surfaces any description over 10 cm width or girth and applying one finishing coat of synthetic enamel paint complete all as specified and directed. |
| 27 | M&L Powder coated Anodised aluminium grill (anodised transparent or dyed to requiredshade according to IS: 1868 with minimum anodic coating of gradeAC 15) of approved design/pattern, with approved standard section and fixed to the existing windowor ventilator frame with C.P. brass/ stainlesssteel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, including dismantling of old grill any type all complete as per requirement and direction. |
| 28 | Taking down chowkats or frames exc 1.5sqm but n.exc 4 sqm each but with shutter (without taking off shutter from the frame)Complete all as specified and directed. |
| 29 | Taking down chowkats or frames n.exc 1.50 sqm each but with shutter (without taking off shutter from the frame) Complete all as specified and directed. |
| 30 | S&F \\"as in repair\\" for door closer hydraulically regulated aluminum (extruded section) body, designation No 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg, fixed as in repairs, Complete all as specified and directed. |
| 31 | S&F powder coated aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. Complete all as specified and directed. |
| 32 | S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, door stopper, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 33 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, necessary locking/sliding arrangement etc. complete all as specified and directed. |
| 34 | M&L 9mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber frame work in cup board shutters / aluminium partions etc. complete all as specified and directed. |
| 35 | S&F 5mm thick figured glass, pin head type and glazing with oil putty / aluminium beading in square exc 0.50 Sqm each in each pane complete all as specified and directed. |
| 36 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm with stainless steel wire staples etc complete all as specified and directed. |
| 37 | S&F 150mm long aluminium anodized barrel tower bolts of extruded sections complete all as specified and directed. |
| 38 | S&F 300mm long aluminium alloy, anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cost of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 39 | Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor etc. Complete all as specified and directed. |
| 40 | M&L for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes, switch plates of suitable make and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following Complete all as specified and directed. |
| 41 | One Light/Fan point controlled by one switch |
| 42 | One switch socket outlet modular type 3 pin 6 amp on same board. |
| 43 | One switch socket outlet modular type 3 pin 6 amp on independent board. |
| 44 | Description all as per item No 40.00 above but 2.5 sq mm cable size and 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 amps on Independent board complete all as specified and directed. |
| 45 | S&F Switch modular type, single pole one way 6 Amps, 240 volts AC suitable for existing modular switch boxes without indicator, Complete all as specified and directed. |
| 46 | S&F socket modular type single pole one way 6 Amps 240 volts suitable for existing modular switch boxes complete all as specified and directed. |
| 47 | S&F socket modular type 16 Amps, 3 pin combine multistandard, 2 module, 240 volts suitable for existing modular switch boxes complete all as specified and directed. |
| 48 | S&F switch modular type 16 Amps,one way with indicator, 1 module, 240 volts suitable for existing modular switch boxes complete all as specified and directed. |
| 49 | S&F for ceiling rose, surface bakelite, 65 x 50 mm, three terminals, ISI marked complete all as specified and directed. |
| 50 | S&F \\"as in repair\\" wall mounted LED 18/20 watts 6500 K with out put of 1800 lumens , box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with integral LED tube 4' x 18 watts Complete all as specified and directed. |
| 51 | S&F \\"as in repair\\" LED building security lights 25 W IP 66 including 1.5mtr long GI bend pipe of suitable dia and all necessary accessories complete all as specified and directed. |
| 52 | S&F \\"as in repair\\" exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with blades, frame and louver including making of holes (if required) for exhaust fan alongwith removal of old exhaust fan and deposit to E/M sub division storeyard complete all as specified and directed. |
| 53 | S&F \\"as in repair\\" for sub main wiring (concealed) complete with two run of single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade ISI marked and conduit accessories including 4 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface including taking out old existing wire and conduit complete all as specified and directed.Note:- 3 run of 4 sqmm&one run of PVC conduit shall be measured as single unit |
| 54 | S&F \\"as in repair\\" sheet metal enclosures for SPN DB's with metal double door for incorporating MCBs, IP-43, 8 way with 200 amps rated busbar, 240 volts, as per IS-8623 including taking down of existing DBs complete all as specified and directed. |
| 55 | S&F \\"as in repair\\" MCB SPN, 32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc Complete all as specified and directed. |
| 56 | S&F \\"as in repair\\" MCB SP 6-32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002,integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc. complete all as specified and directed. |
| 57 | M&L \\"as in repair\\" for Earthing complete with galvanised steel plate electrode, 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in plate No. 3 of SSR PART 1 of 2009 to the earthing test point inc testing on completion all as specified and as directed. Note :- the cost of excavation and earth work PCC pit and RCC cover funnel & watering pipe, wiremesh, charcoal dust and common salt earth lead protection pipe upto 7.5 Rmt shall be deemed included in the unit rate for earthing Complete all as specified and directed. |
| 58 | Supply, laying and testing in replacement of XLPE cable Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 2.0 core complete all as specified and directed. |
| 59 | Supply and laying in replacement of DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia 50 mm and inner dia 38 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like socket, coupler, bends, tees etc for protection of LT cable complete all as specified and directed. |
| 60 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material Complete all as specified and directed. |
| 61 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested Complete all as specified and directed. |
| 62 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysOct 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer