| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed. |
| 3 | Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point, complete all as specified and directed. |
| 4 | Supply and filling of river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified.Note : Punned thickness of sand shall be measured & paid only. |
| 5 | Supply and laying well burnt old size bricks, sub class \\"B\\" bricks, straight or curved on plan, laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified. |
| 6 | M & L for boring of holes below road for laying of pipe not exceeding 90 cm below ground level by mechanical means complete all as specified and as directed. |
| 7 | S & F GI tubes light grade of size 40mm with all fittings for road / nala crossing complete all as specified and directed. |
| 8 | Supply and filling of buolder / stone aggregate of 40 to 63mm size graded crushed stone below cable in the station yard complete all as specified and directed. |
| 9 | S & F in repairs danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws, nut bolts with adequate size clamps on HT/LT pole of 25x20 cm size complete all as specified and directed. |
| 10 | M&L for PCC (1:4:8) type D-2 using 40 mm graded aggregate as in base foundation of pole concrete including providing necessary form work complete all as specified and directed. |
| 11 | M&L for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole/stay and filling of mass concrete including providing necessary form work complete all as specified and directed. |
| 12 | M&L for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping of pole including providing necessary form work complete all as specified and directed. |
| 13 | M&L for removing the vegetation growth for site clearence in soft /loose soil in around HT/LT poles, around E/M installations complete all as specified and directed. |
| 14 | Material & Laying, jointing and testing in replacement of LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers ,alumunium thimble , ferrule complete all as specified and directed. Note :- (i) Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and GI pipe shall be measured and paid separately under appropriate items.(ii) PVs & MTC of LT XLPE cables alongwith e-way bill shall be submitted by contractor during claiming of RAR / Final bill as applicable. |
| 15 | All as per item No 14 above but of size 16 Sqmm 4 core |
| 16 | All as per item No 14 above but of size 25 Sqmm 4 core |
| 17 | All as per item No 14 above but of size 35 Sqmm 3.5 core |
| 18 | All as per item No 14 above but of size 50 Sqmm 3.5 core |
| 19 | All as per item No 14 above but of size 70 Sqmm 3.5 core |
| 20 | All as per item No 14 above but of size 95 Sqmm 3.5 core |
| 21 | Disconnecting the existing cable from Panel / Pole, preparing the end for jointing including all earth work, Supply and fixing straight through heat shrinkable joint suitable for LT XLPE cable of size 3.5/4 core 10 to 16 sq mm complete all as specified and as directed. |
| 22 | All as per item No 21 above but size 25 to 50 Sqmm |
| 23 | All as per item No 21 above but size 70 to 120 Sqmm |
| 24 | Disconnecting faulty 1.1 KV LT cables of any size and any length from both ends Hiring of cable fault detector machine to detect exact position of fault , removal of Fault, Re-connections and testing of cables after removal of fault including excavation, returning filling, Removal, relaying of cable protection cover etc complete as specified and directed. Note : (a) 1.1 KV LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdown alongwith fault locating machine and manpower. In case the rep or contractor shall not come to the site of breakdown and not to start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues. |
| 25 | Supply, fixing, connecting and testing in replacement MCCB 63 Amp 4 pole 16 KA 415 volts 50 Hz with spreader after taking down old existing unserviceable MCCB complete all as specified and as directed. |
| 26 | Supply, fixing, connecting and testing in replacement MCCB 100 Amp 4 pole 16 KA 415 volts 50 Hz with spreader after taking down old existing unserviceable MCCB complete all as specified and as directed. |
| 27 | Supply, fixing, connecting and testing in replacement MCCB 125 Amp 4 pole 16 KA 415 volts 50 Hz with spreader after taking down old existing unserviceable MCCB complete all as specified and as directed. |
| 28 | Supply, fixing, connecting and testing in replacement MCCB 160 Amp 4 pole 25 KA 415 volts 50 Hz with spreader after taking down old existing unserviceable MCCB complete all as specified and as directed. |
| 29 | Supply, fixing, connecting and testing in replacement MCCB 200 Amp 4 pole 36 KA 415 volts 50 Hz with spreader after taking down old existing unserviceable MCCB complete all as specified and as directed. |
| 30 | Supply, fixing, connecting and testing in replacement MCCB 250 Amp 4 pole 36 KA 415 volts 50 Hz with spreader after taking down old existing unserviceable MCCB complete all as specified and as directed. |
| 31 | Supply, fixing, connecting and testing in replacement MCCB 400 Amp 4 pole 36KA 415 volts 50 Hz with spreader after taking down old existing unserviceable MCCB complete all as specified and as directed. |
| 32 | Supply, fixing, connecting and testing in replacement MCCB 630 Amp 4 pole 36 KA 415 volts 50 Hz with spreader after taking down old existing unserviceable MCCB complete all as specified and as directed. |
| 33 | Supply & Fixing in replacement twin core, 6 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and as directed. |
| 34 | Supply & Fixing in replacement twin core, 10 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and as directed. |
| 35 | S&F wheather proof pole mounting junction box, base and door of junction box made out of SMC having outside dimention 333x233x120mm, inside dimention 300x200x105mm , single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body complete all as specified and as directed. |
| 36 | M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.(ii) Cost of excavation & other earth work shall be deemed inclusive in quoted unit rate.(iii) Earth wire upto 7.5 RM from test point shall be deemed inclusive in quoted unit rate. |
| 37 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.(ii) Cost of excavation & other earth work shall be deemed inclusive in quoted unit rate.(iii) Earth wire upto 7.5 RM from test point shall be deemed inclusive in quoted unit rate. |
| 38 | Material and labour for cleaning and preparation for painting surface of steel iron surface of street light steel tubular pole 9mtr long and painting with two coat of aluminum paint including brackets including applying two coats of cement base paint to coping,strip painting up to 1mtr from coping with blue and white colour paint of strips ,writing Pole No etc complete all as specified and directed. |
| 39 | Supply and fixing and testing 60 W LED street light fitting with IP65/66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass/polycarbonate LED lenses, surge protecton device of 4KV Internal and 10KV External, BIS electronic potted/encapsulated driver and all accessories pre-wired including connecting up with PVC insulated copper conductor cable 1.5 Sq mm, 3core.Street light should have, impact resistance of IK 07 , Lumen efficiency of LED not less than 110 lumen per watt system efficiency ,power factor >0.95, THD<10% at Full load CRI> 70% ,street light should have , lower THD, open circuit protection , over voltage protection , surge voltage protection. Company LOGO ingraved on housing of the street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement. |
| 40 | S&F in replacement street light fitting Pressure die cast aluminium housing (LM6 Alloy), Minium 9000-10000 Lumens with maximum system wattage 90 W-100 W, with PMMA lenses,External built proper heat shinks and toughtened glass/PC ensuring IP66 & IK>05 protection, LED used shall be SMD type and fixture should have minium efficiency at system level (Not chip level) 100 Lumens/Watt, Life of system should 50000 Hrs all including necessary wire for fitting light to pole all as specified and directed by Engr-in- Charge. |
| 41 | S&F in replacement of LED security light fitting 45 watt, 4000 lumen, 5700K with IP 66 protection comprises of a pressure die cast aluminium housing, heat resistance toughened glass, LED lenses, surge protector, electronic driver, etc and all accessories pre-wired including suitable mounting arrangement complete all as specified and directed. |
| 42 | Supplying & fixing including transporting, erecting Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, top cover, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed and painting steel tubular poles exposed surafces with aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel yellowpaint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed. |
| 43 | Supply and fixing in replacement of 120 W LED flood fitting having epoxy powder coated die cast aluminium housing ADC12 in grey finish with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout , PC lens/IP lens with narrow /wide beam distribution and toughened glass fixed to housing with screws, flood light should have IP 66 protection and impact resistance of IK 07, Lumen efficiency of LED not less than 110 lumen per watt system efficency, power factor >0.95, THD<10% at Full load CRI> 70% ,flood light should have built in potted electronic LED driver with, lower THD, open circuit protection, over voltage protection, surge voltage protection, and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge.Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement. |
| 44 | S&F LED post top lantern fitting for 360 degree indirect light 35W IP 65 protection complete protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver,holders, connector etc. Complete with all accessories,prewired and including connecting up with three core flexible copper conductor cable with suitable size including taking down / dismantling the old items complete all as specified and directed. |
| 45 | S&F bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5 m long including necessary GI clamps, nuts bolts and washers and connecting with thee core flexible wire of 1.5 sq mm copper conductor to the pole junction box including taking down / dismantling the old items complete all as specified and directed. |
| 46 | Repair and servicing of 250 kva CSS and repair/ replacement of relay, Fuze, MCCB's, repair CT's, incl 250 kVA dry type transformer replacement of burrent coil replacement and contractor, relay testing, vaccum Interrupeters, closing coils, spring charging motor, SF6 gas refiling, contractor & relays, cable termination kit, Anti condensation heaters, thermostate and cooling fans, panel door lockes and hinges etc complete all as specified and as directed. |
| 47 | S & F Gasketes and O rings complete |
| 48 | S & F Silica Gel Breather complete |
| 49 | S & F Buchholz Relay Complete. |
| 50 | S & F oil level & temprature gauger. Complete. |
| 51 | S & F HV/ LV bushing complete. |
| 52 | S & F HRC Fuses complete. |
| 53 | S & F Digital multifuction meter complete. |
| 54 | S & F Auxiliary relays complete. |
| 55 | M&L for repair and servicing of 62.5 KVA DG & 82.5 KVA set including fault finding and replacement of defective parts such as engine oil , oil fiter, air filter etc complete, all as directed. Note: Fixture/spares Shall be paid and measured seperately under repective items. |
| 56 | M & L for castrol engine oil in 01 Ltr pack complete specified all as directed. |
| 57 | M & L for engine oil filter suitable for 62.5 KVA DG & 82.5 KVA set complete all as specified and directed. |
| 58 | M & L for engine air filter suitable for 62.5 KVA DG & 82.5 KVA set complete all as specified and directed. |
| 59 | M & L for repair and servicing of AMF panel board including fault finding and replacement of defective parts such as voltmeter, Ammeter, frequency meter, relays with wiring, complete, all as directed. Note: Fixture/spares Shall be paid and measured seperately under repective items. |
| 60 | M&L for repair and servicing of Automatic power factor controller panel (TAS Powertek Pvt Ltd) board including fault finding and replacement of defective parts such as voltmeter, Ammeter, frequency meter, capacitor relays, start/stop push buttons MCB with wiring, complete, all as directed. Note: Fixture/spares Shall be paid and measured seperately under repective items. |
| 61 | Supply and fixing single core Copper wire having nominal area10 sqmm , PVC insulated, multistranded, FR, for LT panels including necessary lugs and thimble as required on ground complete all as specified and as directed. |
| 62 | Supply & fixing MNX power contactor 415 Volt, 50 Hz, AC of capacity 110 Amps as per sample complete all as specified and as directed. |
| 63 | Supply & fixing SMPS battery charger kit mounting in AMF panel as per sample all complete all as specified and as directed. |
| 64 | Supply and fixing AMF controller module in AMF panel as per sample alongwith connected relays and wiring complete all as specified and as directed. |
| 65 | Supply & fixing automatic generator start/stop relay as per sample complete all as specified and as directed. |
| 66 | Supply & fixing of HRC Fuse unit HN size,100 amp 100 KA 415 Volt as per sample complete all as specified and as directed. |
| 67 | Supply and fixing of MCB DP 20 Amp 10 kA 'C' curve complete all as specified and as directed. |
| 68 | Supply and fixing of MCB DP 40 Amp 10 kA 'C' curve complete all as specified and as directed. |
| 69 | Supply and fixing of MCB DP 63 Amp 10 kA 'C' curve complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 70 | Supply and fixing of MCB DP 63 Amp 10 kA 'C' curve complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender