Tender for General-Supply Installation Testing And Commissioning Of Cctv -Surveillance System In Breakwater At Muthalapozhy-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | CCTV AT BREAKWATER |
| 2 | OD5231/2026-2027:Supplying, installation, testing and commissioning of a 2 Mega Pixel IP-based outdoor network PTZ CCTV camera featuring a 1/2.8" Progressive Scan CMOS image sensor, minimum resolution of 1920 x 1080 pixels at 25/30 fps, high-performance motorized optical zoom of minimum 32x to 45x and 16x Digital Zoom, featuring integrated Electronic Image Stabilization (EIS) , variable motorized focal length covering a minimum span of 4.25 mm to 136 mm and up to a maximum span of 3.95 mm to 177.75 mm, ultra-low light performance with minimum color illumination of 0.005 Lux at F1.6, integrated high-power smart laser infrared illumination or dual supplement light technology with a night vision range of minimum 150 meters up to 500 meters, optional built-in active deterrence white flashing strobe light with an audible speaker warning system, True 120dB Wide Dynamic Range (WDR), 2D/3D Digital Noise Reduction (DNR), Backlight/Highlight Compensation (BLC/HLC), and electronic Defog/Demist. The camera unit shall support triple-stream up to penta-stream capability with high-efficiency video compression technologies including H.265, H.264, or equivalent AI-optimized smart compression codecs. It must feature an integrated mechanical smart lens wiper or auto-demist structure, a durable heavy-duty industrial outer housing with a certified weatherproof rating of minimum IP66 up to IP67 and an impact resistance rating of IK10 vandal-proof protection, operational sustainability within an outdoor working window spanning from –30°C to +65°C and stretching up to –40°C to +70°C, and built-in TVS 6000V lightning proof, surge, and voltage transient protection suitable for harsh environments. The system shall feature embedded deep-learning target algorithms and Intelligent Video Surveillance (IVS) analytics supporting human and vehicle classification, auto-tracking, tripwire perimeter security, intrusion detection, abandoned/missing object alarms, face detection, loitering, and crowd gathering alerts. Hardware interfaces must include 1 × RJ-45 (10/100 Base-T) self-adaptive network port, minimum 1-channel audio input and 1-channel audio output or built-in audio hardware, a minimum of 2-channel alarm inputs and 1-channel alarm output scaling up to 7-channel inputs and 2-channel outputs, and local edge storage supporting up to a 256GB or 512GB Micro SD card. The camera must comply with ONVIF Profiles S/G/T, hold a valid Bureau of Indian Standards (BIS) safety registration, and strictly hold a Ministry of Electronics and Information Technology (MeitY) notified Essential Requirements (ER) / STQC certification compliance report for government tender validation, configured to operate seamlessly via a 36 VDC power source or PoE+/Hi-PoE configurations drawing a maximum power consumption of up to 42W, inclusive of all standard mounting accessories (pole/wall brackets), physical connections, configuration software, and programming as required.Standards: BIS with ER, STQC Certified, CE, FCC and RoHS. Make: As approved by the department officials from the approved list in tender document. The bidder should provide (OEM) manufacturers warranty for 3 years after installation and have STQC certification of the product at the time of installation and should produce relevant certificate for the same. |
| 3 | OD5285/2026-2027:Supplying, Installation, Testing & Commissioning of a 24-inch Professional Commercial Signage Display, featuring Full HD (1920 × 1080) resolution, commercial-grade panel with minimum 250 to 300 nits brightness, minimum 1000:1 contrast ratio, 178°/178° viewing angle, rated for 16/7 continuous commercial operation, built-in SoC platform (Samsung Tizen / MagicINFO or OEM-equivalent embedded digital signage media player), integrated Wi-Fi & Bluetooth, inputs/outputs comprising minimum HDMI, USB, RJ45 LAN, and RS-232C control, integrated stereo audio output / speakers, VESA wall mount compliant, suitable for both landscape and portrait orientation, complete with heavy-duty coastal-rated wall-mounting brackets, power cables, and all standard mounting and physical connection accessories. Make: As approved by the department officials from the approved list in the tender document. Warranty: OEM manufacturer warranty for 3 years after successful installation and commissioning. |
| 4 | OD5228/2026-2027:Supplying, installation, testing and commissioning of an 8-Port Gigabit commercial-grade unmanaged Power over Ethernet (PoE) network switch . The hardware interface profile shall feature 8 × 10/100/1000 Mbps self-adaptive RJ45 copper downlink ports fully complying with IEEE 802.3af/at Power over Ethernet protocols, paired with a flexible copper/fiber aggregation uplink interface consisting of a minimum of 2 × 10/100/1000 Mbps independent RJ45 copper uplink ports and/or up to 2 × 1000 Mbps independent SFP fiber optic uplink slots. The internal power architecture shall be rated to receive standard nominal alternating current (AC) power utility inputs spanning 100-240V AC at 50/60Hz, distributing a fixed Power over Ethernet budget allocation of minimum 53W to 120W total across all active downlink nodes. Performance parameters must incorporate a non-blocking switching fabric capacity of minimum 16 Gbps to 22 Gbps, a packet forwarding throughput rate of no less than 11.9 Mpps to 16.368 Mpps, an internal packet buffer memory of minimum 2 Mbit, and a hardware-based 4K to 8K MAC address table architecture supporting auto-learning and auto-aging. The unit shall feature plug-and-play installation requiring zero physical software management layers, utilizing automatic MDI/MDIX cross-over detection on all copper interfaces alongside integrated 4kV common-mode surge and lightning protection safeguards. The device body must be housed in a durable, fanless, compact metal casing optimized for standard desktop, rack, or shelf placement, maintain stable operational profiles within a temperature spectrum of 0°C to +40°C, and hold standard Bureau of Indian Standards (BIS) safety registration for public procurement compliance, inclusive of physical patch cords, SFP module node adjustments, and operational network layout testing as required.Make: As approved by the department officials from the approved list in tender document. The bidder should provide (OEM) manufacturers warranty for 3 years after installation. |
| 5 | OD5229/2026-2027:Supplying, installation, testing and commissioning of an industrial-grade Layer 2+ managed 8-Port Gigabit Power over Ethernet (PoE) network switch . The hardware architecture shall feature a minimum of 8 × 10/100/1000 Mbps self-adaptive RJ45 Ethernet downlink ports complying with IEEE 802.3af/at PoE protocol parameters, paired with a minimum configuration of either 4 independent SFP fiber uplink slots or 2 dedicated SFP fiber uplink slots to support versatile network layouts. The switch must feature an external or integrated power delivery framework engineered to support a total PoE power budget allocation of minimum 55W scaling up to 250W across active downlink nodes. Internal performance metrics must include a minimum non-blocking switching fabric capacity of 20 Gbps to 24 Gbps, a packet forwarding throughput rate of no less than 14.88 Mpps up to 17.856 Mpps, an internal packet buffer memory of minimum 2 Mbit to 4.1 Mbit, and an 8K hardware MAC address table architecture. System management infrastructure must feature a comprehensive web interface or CLI configuration platform supporting 802.1Q VLAN tagging, Quality of Service (QoS) traffic scheduling, IGMP/MLD Snooping to filter multicast storms, port mirroring, Link Aggregation Control Protocol (LACP), and advanced spanning tree protocols including STP, RSTP, and MSTP alongside sub-20ms ERPS ring redundancy links. Network security layers must provide native hardware execution for Access Control Lists (ACL), DHCP Snooping, IP Source Guard, 802.1X authentication, and Denial of Service (DoS) attack prevention managed via SNMP v1/v2c/v3 variables. The physical unit shall be enclosed in an unmanaged or fanless IP40-rated metal housing suitable for DIN-rail or standard 19-inch shelf integration, support optional dual redundant DC inputs or a standalone AC adapter source, withstand severe operational temperature spectrums spanning from 0°C to +40°C up to extreme limits of 40°C to +75°C, and incorporate a minimum of 6kV lightning and common-mode surge protection safety components. The hardware must hold standard Bureau of Indian Standards (BIS) product registration for public procurement validation, inclusive of all system programming, SFP module fitting, patch cords, splicing node terminal configurations, and comprehensive operational network commissioning as required.Make: As approved by the department officials from the approved list in tender document. The bidder should provide (OEM) manufacturers warranty for 3 years after installation. |
| 6 | OD5306/2026-2027:Supplying, Installation, Testing and Commissioning 8 TB capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 8 TB (Tera byte). Make: As approved by the department officials from the approved list in tender document . OEM warranty for 3 years |
| 7 | OD5230/2026-2027:Supplying, installation, testing and commissioning of an 8-Channel 4K IP Network Video Recorder (NVR) featuring an industrial-grade embedded processor running on a secure Linux operating system. The system shall possess a high-performance network bandwidth layout supporting a minimum incoming and recording throughput capacity of 80 Mbps up to 384 Mbps, an outbound bandwidth profile of 64 Mbps to 384 Mbps, and native processing capabilities for ultra-high-resolution IP cameras ranging from 12 Megapixels up to 32 Megapixels. The recorder must deliver flexible, multi-channel hardware decoding configurations capable of processing up to 2-channels at 12MP/16MP, 3-channels at 8MP/4K, or up to 8-channels at 4MP/1080p resolutions concurrently at 30 fps, utilizing advanced compression architectures including H.265, H.264, or equivalent AI-optimized smart compression codecs to optimize network pipeline throughput and storage utilization. Hardware storage infrastructure shall feature 2 internal SATA interfaces accommodating scalable configurations from 10 TB up to 20 TB capacity per individual hard disk drive slot for a total internal raw storage threshold of up to 40 TB. Simultaneous or independent video display layout routing must be provided via 1 × HDMI port supporting up to 4K (3840 x 2160) ultra-HD displays and 1 × VGA port supporting standard 1080p Full HD monitors. The platform shall incorporate embedded Intelligent Video Surveillance (IVS) analytics driven either natively by the recorder or through camera pass-through metadata, supporting up to 8 channels of hardware or software-based intelligent motion detection optimized to filter environmental false alarms, up to 4 channels of virtual perimeter protection (tripwire and intrusion alerts), automatic number plate recognition (ANPR), and AI Face Recognition capable of managing up to 10 to 20 discrete face databases holding up to 20,000 distinct images. Peripheral hardware integration interfaces must include 1 × RJ-45 (10/100/1000 Mbps) self-adaptive Gigabit Ethernet port, 1-channel RCA audio input and 1-channel RCA audio output for full bidirectional two-way talk, a minimum of 4-channel alarm inputs and 2-channel alarm outputs, 1 × USB 2.0 front-panel interface, and 1 × USB 3.0 rear-panel interface optimized for high-speed local data backups. The NVR hardware shall be enclosed within a standard 1U space-saving rack-mountable chassis, maintain sustained operational reliability under ambient environmental limits spanning 10°C to +55°C, draw operational power via a 12VDC, 4A external adapter consuming a maximum power envelope of less than 10W to 15W excluding internal hard disks, and strictly hold full Bureau of Indian Standards (BIS) product certification for government procurement compliance, inclusive of all device software licenses, terminal configuration programming, and operational network integration testing as required.Make: As approved by the department officials from the approved list in tender document. The bidder should provide (OEM) manufacturers warranty for 3 years after installation. |
| 8 | OD5194/2026-2027:Supplying, installation, testing and commissioning of a wall/pole-mountable Light Interface Unit (LIU) optical distribution frame enclosure , featuring a high-density compact chassis with a capacity profile of not less than 4 to 6 fiber termination ports. The LIU body shell shall be fabricated from premium cold-rolled steel sheets of minimum 1.2mm thickness or high-impact flame-retardant industrial composite polymers, protected via a scratch-proof powder-coated protective surface treatments and equipped with a secure lockable top cover layout. Internal provisions must integrate a dedicated high-capacity ABS optical splice tray complete with fiber management routing guides maintaining a minimum bend radius of 30mm, mechanical splice protection sleeve holders, and a pre-loaded patch panel array containing single-mode simplex LC/UPC adapter couplers featuring high-precision zirconia ceramic alignment sleeves. The enclosure infrastructure shall provide dedicated mechanical compression cable entry ports, internal strength member clamping plates to securely anchor incoming armored trunk fiber cables, and a localized copper grounding termination point. The complete unit shall be rigidly installed inside the control room network rack and within the remote outdoor field enclosure respectively, inclusive of fusion splicing matching single-mode LC/UPC pigtails, heat-shrink splice sleeves, physical dressing, patch cord routing, and terminal port identification labelling as required.Make: As approved by the department officials from the approved list in tender document. The bidder should provide (OEM) manufacturers warranty for 3 years after installation. |
| 9 | OD5224/2026-2027:Supplying, installation, testing and commissioning of a high-speed HDMI (High-Definition Multimedia Interface) digital audio/video interface cable assembly. The cable assembly must possess a physical length profile of not less than 5 meters to facilitate clean, unconstrained routing from the network video recorder (NVR) chassis to the designated control room viewing monitor. The internal cable architecture must feature high-purity, oxygen-free copper conductors insulated within a premium multi-layer high-density shielding mesh to eliminate electromagnetic interference (EMI) and radio-frequency noise degradation over long-distance cable runs. Outer structural protection must incorporate a durable, flexible PVC or braided nylon environmental jacket fitted with integrated strain-relief boots and heavy-duty, corrosion-resistant 24K gold-plated Type-A connectors to prevent port oxidation and signal loss. Performance metrics must comply with minimum HDMI 2.0 standards or equivalent high-speed baseline protocols, delivering a minimum data transfer bandwidth of 18 Gbps, native support for 4K Ultra-HD resolution display outputs at 60Hz, and simultaneous multi-channel digital audio transmission capability. The complete cable layout shall be neatly dressed within control room surface trunking, directly routed, and terminal insertion tested alongside display calibration parameters to ensure absolute video stability as required.Make: As approved by the department officials from the approved list in tender document. |
| 10 | OD5226/2026-2027:Supplying, installation, testing and commissioning of an outdoor pole-mount network equipment enclosure assembly . The system shall feature a heavy-duty, weather-proof and dust-proof industrial enclosure providing an internal space-saving capacity profile ranging from a minimum of 2U up to 6U vertical equipment frames, with an engineering depth layout of not less than 400mm to 450mm. The complete chassis shell shall hold a certified weather protection rating of minimum IP55 up to IP66 alongside an impact resistance certification index of IK10 vandal-proof safety. The physical frame must be fabricated from premium, corrosion-resistant cold-rolled steel sheets treated with multi-stage anti-rust phosphate washes, glass-fiber reinforced polycarbonate, or SS316 stainless steel, heavily UV-stabilized to prevent pitting and salt-spray oxidation in harsh environments. The structure must incorporate a secure lockable front door, an integrated protective rain canopy, durable rubber sealing gaskets, and breathable ventilation louvers featuring insect mesh screen guards. Internal infrastructure configurations must include an adjustable 19-inch vertical or DIN-rail layout mounting track, internal copper earthing/grounding busbars, and a rugged industrial-grade DIN-rail power supply unit (PSU) designed to operate reliably within an ambient outdoor temperature window of ?40°C to +75°C. The internal power supply unit shall accept a standard nominal input of 230V AC (with structural operational tolerances spanning 100-240V AC at 50/60Hz) and deliver a stable, low-ripple output of 12V to 54V DC configured with a minimum output capacity matching peak industrial PoE switch loads, featuring built-in electronic safeguards against short-circuits, over-voltage, and thermal overloads. The complete assembly shall be securely anchored to designated field structural posts using heavy-duty marine-grade SS316 stainless steel pole-mounting brackets, industrial clamping bands, tension straps, structural fasteners, and weather-sealed cable entry glands at the bottom of the enclosure base to prevent moisture ingress, inclusive of all internal power wiring, terminal blocks, input surge protection devices (SPD), mechanical alignment adjustments, and grounding connectivity validation as required.Make: As approved by the department officials. |
| 11 | OD5227/2026-2027:Supplying, stringing, tensioning, testing and commissioning of an outdoor single-mode armored fiber optic cable . The cable configuration shall feature high-purity single-mode OS2 optical fibers with a nominal 9/125 micron core/cladding diameter engineered specifically for low-attenuation high-speed transmission at 1310nm and 1550nm operational wavelengths. Core construction layout shall incorporate a flexible minimum 4-Core up to 6-Core parameter matrix. The internal architecture must utilize jelly-filled loose buffer tubes wrapped around a non-metallic fiber reinforced plastic (FRP) central strength member to maintain uniform tensile pulling stability and absolute protection against moisture ingress. The cable assembly shall feature an integrated water-blocking swellable element wrap layer, encapsulated directly beneath a corrugated electrolytic chrome-plated steel (ECCS) tape armoring designed to provide high mechanical crush resistance and certified security against heavy physical loads and rodent/avian biting damage. The outer environmental jacket profile must consist of a black high-density polyethylene (HDPE) or high-grade flame-retardant outer sheath material, heavily UV-stabilized to withstand direct marine salt-spray and overhead solar radiation exposure along harbor boundaries. Cable transmission metrics must verify a maximum optical attenuation rating of no more than 0.36 dB/km at a 1310nm window and 0.22 dB/km at a 1550nm window, maintaining a short-term installation tensile strength rating of minimum 2000N and a short-term crush resistance index of minimum 2000N/100mm. The system shall ensure absolute operational sustainability within an outdoor climate threshold spanning from ?40°C to +70°C. The continuous field cabling length run of minimum 400 meters shall be deployed overhead, safely suspended across network posting structures, and anchored firmly via marine-grade engineering thermoplastic or alloy aerial tension clamps, suspension brackets, dead-end helical steel structural grips, and corrosion-resistant drop wire anchoring hardware calculated to resist high-velocity wind loads. The cable trunk lines must be terminated cleanly at both ends within wall or pole-mountable Light Interface Units (LIU) via high-precision fusion splicing matching single-mode LC/UPC pigtails, leaving adequate outdoor slack-storage loops on structural field posts to absorb thermal contraction or expanding tension. Final validation must be completed through end-to-end Optical Time-Domain Reflectometer (OTDR) link attenuation verification testing, inclusive of all pole-mounting clamping bands, jointing protection sleeves, splicing consumables, complete technical testing reports, and essential administrative clearances as required.Make: As approved by the department officials from the approved list in tender document. |
| 12 | OD5193/2026-2027:Supplying, drawing, testing, and commissioning of Category 6A (Cat6A) 4-pair outdoor U/FTP horizontal solid copper network cable, featuring 23 AWG solid bare copper conductors with color-coded insulation, Low Smoke Zero Halogen (LSZH) non-plenum sheath, suitable for high-speed data applications supporting up to 10 Gbps over a 100 meter channel, drawn in existing conduit or fixed on surface as required; conforming to ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, and RoHS standards; meeting flammability test IEC 60332-1 and smoke density IEC 61034 requirements; delay skew less than 45 ns; outer cable diameter 7.5 plus/minus 2 mm; third-party tested and verified by UL/ETL; complete with all necessary accessories as required. Make: As approved by department officials from the approved list in the tender document. |
| 13 | 90.15.3.3:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters |
| 14 | OD5268/2026-2027:Supplying, drilling, chemical anchoring, and fixing of Minimast foundation bolts on hard granite rock or breakwater armor structures using Stainless Steel Grade AISI 316 / AISI 316L (A4-70 / A4-80) threaded studs of suitable size (M16 to M24 x upto 900 mm length or as directed by Engineer in charge at site) by chemical injection process, including rotary hammer or core drilling of specified hole diameter and embedment depth (minimum 10d to 12d) into solid hard rock, thorough hole cleaning using oil-free compressed air at minimum 6 bar pressure and round steel wire brushing following the 4-times blow and 4-times brush sequence, injection of European Technical Assessment (ETA Option 1) certified marine-grade pure epoxy or vinyl ester chemical resin mortar resistant to seawater, salt mist, and chlorides, setting of threaded studs complete with 2 Nos. SS 316 heavy hex nuts, 2 Nos. SS 316 flat washers, 1 No. SS 316 spring lock washer, and neoprene/nylon isolation washers per bolt to prevent bi-metallic corrosion, shuttering and casting of M30/M35 grade sulphate-resistant non-shrink concrete levelling pad/foundation pedestal of minimum 150 mm thickness above rock level, high-strength non-shrink polymer precision under-grouting beneath the minimast base plate, conducting on-site field hydraulic pull-out load testing on installed chemical anchors (10% or minimum 2 anchors per location) up to design proof load, along with all labour, machinery, tools, air compressors, scaffolding, marine safety equipment, testing, and clearing site complete as per technical specifications and as directed by the Engineer-in-Charge. |
| 15 | OD5251/2026-2027:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following size overhead, securely clamped/fixed onto existing supports/structures, including structural modifications, tensioning, and all necessary hardware as required- 4 core 6 sq mm |
| 16 | OD5379/2026-2027:Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE conductor cable of 1.1 KV grade as required.4 X 6sq. mm (25mm) |
| 17 | OD5190/2026-2027:Supply installation, testing and commissioning of RJ45 connectors or injuctors and identifying the cable ,Terminations with Accessories using Industrial grade shielded onnectors etc complete as directed by the Engineer in charge at site |
| 18 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 19 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 20 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 21 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 22 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 23 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 24 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 25 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 26 | 1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 27 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 28 | 1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 29 | 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 30 | 90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 31 | 90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface |
| 32 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 33 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 34 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 35 | OD5297/2026-2027:Supply and fixing IP 65 HENSEL 1 row 6 module( Model No KV 7106)146 x 238 x 111 KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws. |
| 36 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 37 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 38 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 39 | 5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 40 | 5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 41 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 42 | 5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 43 | 7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 44 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 45 | 14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. |
| 46 | 14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia |
| 47 | OD5283/2026-2027:Supply, Installation, Testing & Commissioning of 1 kVA (800 W) True Online Double Conversion UPS with DSP based technology (VFI-SS-111), Pure Sine Wave Output, Input Voltage 230V AC, Output Voltage 230V AC (adjustable 220/230/240V), Output Frequency 50/60 Hz, LCD Display, Automatic Static & Maintenance Bypass, ECO Mode, Converter Mode, Intelligent Auto Restart after Mains Failure, Input Power Factor ?0.99, Output THD <3% (linear load), AC-AC Efficiency minimum 87% at full load, overload and short circuit protection, battery deep discharge protection, battery charging management, RS232 & USB communication ports, optional SNMP/MODBUS support, complete with all internal accessories, suitable for external battery bank, conforming to IEC 62040-1, IEC 62040-2, IEC 62040-3, IS 16242, CE & RoHS complete as required.Including the supply of Sealed Maintenance Free (SMF) Valve Regulated Lead Acid (VRLA) Battery, 12 V, 26 Ah (C10 Rating), suitable for Online UPS application, rechargeable, maintenance free, leak-proof construction with ABS flame-retardant container, high-rate discharge performance, low self-discharge, float and cyclic operation, complete with factory charged electrolyte. Battery shall conform to IS/IEC 60896 (Latest Amenmend) and suitable mounting rack interconnection complete as requied at site. The warranty of the battery and ups for 3 years after installation required. The warranty of the battery and ups for 3 years after installation required. |
| 48 | OD5353/2026-2027:Supply and laying of 32 mm HDPE Pipe, ISI marked, made of High Density Polyethylene , suitable for underground protection of power, control, CCTV and OFC cables, complete with couplers, bends, end caps, jointing materials and all accessories, including laying, testing and commissioning, as required for a complete installation. |
| 49 | OD5356/2026-2027:Supplying, stringing, and tensioning of 10 SWG (approx. 3.25 mm dia) PVC-insulated galvanized iron (G.I.) wire (conforming to IS 280 / IS 4826) to act as a catenary/bearer and binding support for aerial Optical Fiber Cable (OFC) along with 4 x 6 sq. mm power cable on 6.0 m octagonal steel poles, including lashing, binding, and securing the OFC to the bearer wire using UV-stabilized ties/insulated binding wire at intervals not exceeding 300 mm, along with hot-dip galvanized pole clamps, eye bolts, heavy-duty turnbuckles, thimbles, earthing connections, and all associated hardware complete as required. as directed by the Engineer In charge at site. |
| 50 | OD5377/2026-2027:Supplying, fixing, adjusting, and commissioning of pole mounting and clamping hardware assemblies on existing 6.0-metre octagonal steel poles for supporting and securing existing aerial Optical Fiber Cable (OFC) , for intermediate straight pass-through poles (line deviation < 15°), corrosion-resistant aluminium-alloy suspension / J-hook clamps fitted with elastomeric neoprene rubber cushions, pigtail eye-bolts, shackle fittings, and dual 20 mm x 0.75 mm Grade 304/316 stainless steel pole banding straps with heavy-duty buckle clips, for terminal/anchoring/turning dead-end poles (line deviation > 15°), heavy-duty hot-dip galvanized anchor brackets, forged clevis/D-shackles, and preformed helical dead-end tension grips / wedge-type dead-end tension clamps engineered to anchor mechanical tension without crushing fiber buffer tubes; and for designated splice/terminal poles, hot-dip galvanized steel slack cable storage bracket (snow-shoe/cross-arm loop assembly) to neatly house spare fiber loops alongside fiber splice closures; including all necessary fasteners, turnbuckles, thimbles, bonding lugs to the pole earthing stud, testing, and tension balancing complete as directed by engineer-in-charge at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender