Housing Urban and Rular Development Government Departments Closing in 15 days TDR #57390465

Tender For Setting Up Of New Digital X-Ray Room At Lalbagh Sub Divisional Hospital --- Allied electrical installation Works.

Issued by Government Departments · Murshidabad, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Sep 2026
15 days left
EMD
57165
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Murshidabad → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Setting Up Of New Digital X-Ray Room At Lalbagh Sub Divisional Hospital --- Allied electrical installation Works.

BOQ

Name of Work:- Setting up of new Digital X-Ray Room at Lalbagh Sub Divisional hospital --- Allied EI Works.
Sl. No. Item Description
1Supply, installation, testing and commissioning of 415V, 4P, 400A MCCB with thermal-magnetic release and 50kA breaking capacity, suitable for existing LT panel, including spreader links, connection accessories, mounting hardware, termination, testing and commissioning, complete. (Lauritz Knudsen DU400N/Schneider G40N4A400)
2Supplying and fixing 415V, 200A, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse (L&T, Simens)
3Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) (Havells/Polycab/RR Kabels)
44 core 240 sqmm
54 core 95 sqmm
64 core 70 sqmm
7Laying of two cables above 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
8Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc.
9Supplying & fixing medium gauge 80 MM dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
10Supply, Installation, Testing & Commissioning of floor mounted indoor panel cubicle type self-supporting compartmentalized dust and vermin proof MV Panel with separate busbar and cable alleys fabricated from 3 mm thick CRCA sheet steel, having rigid angle/channel iron base frame, complete with necessary interconnections by suitable size copper solid links/bar, cable end terminations, drilling, hardware, ferruling, identification tags, cable glands, removable gland plates, earthing arrangements, internal wiring, powder coated finish (approved shade) and all accessories required for safe and satisfactory operation as directed by the Engineer-in-Charge.(A) INCOMING:(i) 415 Volt, 400 Amp,50kA , 4 Pole MCCB having adjustable(320A to 400A) thermal-magnetic release with extendted Rotary handle and as per system fault level – 1 No. (Make: Siemens/L&T DN3-400N, Cat No. CM94103OOR1OG equivalent of Schneider/ABB)(ii) 415 Volt, 315 Amp, 36kA, 4 Pole On-load Front Operated Changeover Switch – 1 No. (Make:L&T, CO3-315, Cat No-CO33150OOOO or equivalent of Schneider/ABB)(B) BUS BAR CHAMBER:415 Volt, 4 Bar Aluminium Busbar System of 1200 Amp rating complete with suitably sized aluminium busbars mounted on suitable heavy-duty insulating busbar support insulators, including heat-shrink sleeves for phase identification, drilling, fastening, busbar joints, shrouding and all accessories required for safe operation and as approved by the EIC(C) OUTGOING:(i) 415 Volt, 160 Amp,50kA, 4 Pole MCCB, thermal-magnetic release with extendted Rotary handle – 2 Nos. (Emergency Feeders) (Make: L&T, DN2-250N, Cat No. CM92105OOM1OG or equivalent of Schneider/ABB) (ii) 415 Volt, 200 Amp,50kA, 4 Pole MCCB, thermal-magnetic release with extendted Rotary handle – 1 Nos. (Emergency Feeders) (Make: L&T, DN2-250N, Cat No. CM92106OOP1OG or equivalent of Schneider/ABB)(iii) 415 Volt, 160 Amp,50kA, 4 Pole MCCB, thermal-magnetic release with extendted Rotary handle– 3 Nos. (Raw Feeders) (Make: L&T, DN2-250N, Cat No. CM92105OOM1OG or equivalent of Schneider/ABB)(iv) 415 Volt, 63 Amp,36kA, 4 Pole MCCB thermal-magnetic release with extendted Rotary handle – 2 Nos. (Raw Feeders) (Make: L&T, DZ1-160D, Cat No. DZ1F0080DXD1AOOOO or equivalent of Schneider/ABB)
11(iv) BUS BAR CHAMBER(For Emergency Power):415 Volt, 4 Bar Aluminium Busbar System of 800 Amp rating complete with suitably sized aluminium busbars mounted on suitable heavy-duty insulating busbar support insulators, including heat-shrink sleeves for phase identification, drilling, fastening, busbar joints, shrouding and all accessories required for safe operation and as approved by the EIC(D) INSTRUMENTS:(i) 0–500 Volt Analog Voltmeter (Make: AE) with selector switch(Make: Kaycee/L&T) – 1 Set(ii) 0–500 Amp Analog Ammeter (Make: AE) with selector switch – 1 Set (Make:Kaycee/L&T) (iii) Current Transformers, ratio 400/5A, Class 1 accuracy suitable for metering – 3 Nos. (Make: Kappa)(iv) DIN mounted MCBs with suitable rating units for instrument and control circuit protection – 3 Nos.(v) LED type phase indication lamps (R-Y-B) complete with wiring and accessories – 3 Nos. (Make: Siemens/L&T)(vi) Danger Notice Board (6” × 4”) – 1 No.The panel shall further include copper control wiring with ferrules and cable markers, internal interconnections, earth busbar, door earthing with flexible copper braid, neutral link, busbar supports, segregation between busbar and cable alleys, nameplates, heat shrink sleeves, nut-bolt-washer hardware, and all other necessary accessories required for complete, safe, and efficient operation, testing and commissioning of the panel as per relevant IS/IEC standards and directions of the EIC
12Supplying and fixing double door 8 way Vertical TPN MCB Distribution board for upto 250A MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make: Schinder/Legrand)
13Supplying and fixing 200 A, 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make : L&T/ Schneider/Seimens/ABB)
14Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB 8 Way vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment
15Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/Schinder/Simens)
16125 A FP
1763 A FP
1840 A FP
19Supplying and fixing double door 4 way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make : Schinder/legrand)
20Supplying and fixing 100 A FP,415 V FP MCB Isolator on din rail of existing DBs and necessary connection (Make : Schinder/legrand/Seimens)
21Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
2263 TP
2340 TP
2432 TP
25Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
26upto 240 sqmm
27upto 95 sqmm
28upto 70 sqmm
29Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
304 core 240 sqmm cable
314 core 95 sqmm cable
324 core 70 sqmm cable
33Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required (VTPN to HTPN)
344x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
35Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
3610 sq mm
376 sq mm
38Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts (For panel earthing & equipment earthing)
39Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required ((For panel earthing))
40Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. (For panel earthing)
41Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
42Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
43Supply and fixing of fabricated tined copper bar duly two Nos hole of suitable dimension as per site requirement having facility for connecting two Nos. lugs of 240 sq mm Al cable to connect with the 400 Amp MCCB termital as per direction of the EIC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57390465
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 23-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Setting Up Of New Digital X-Ray Room At Lalbagh Sub Divisional Hospital --- Allied electrical installation Works.
Basic Detail
Tender No WBPWD/EE/MsdED/116/e-Q of 26-27
Bidding Type Tender
Location
City Murshidabad
State West Bengal
Key Dates
Publish Date 07 Sep 2026
Submission Date 23 Sep 2026
Open Date 25 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 57165
Exemption Not Available
Document List
64f63502-c075-4ec7-a731-4390cefbc0ba.html
BOQ_5104486.xls
Tendernotice_1 (38).pdf
Tendernotice_2 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Sep 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

64f63502-c075-4ec7-a731-4390cefbc0ba.html

xls

BOQ_5104486.xls

pdf

Tendernotice_1 (38).pdf

pdf

Tendernotice_2 (4).pdf

Disclaimer