Tender For Setting Up Of New Digital X-Ray Room At Lalbagh Sub Divisional Hospital --- Allied electrical installation Works.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Sep 2026
15 days left
EMD
57165
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Murshidabad → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Setting Up Of New Digital X-Ray Room At Lalbagh Sub Divisional Hospital --- Allied electrical installation Works.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of 415V, 4P, 400A MCCB with thermal-magnetic release and 50kA breaking capacity, suitable for existing LT panel, including spreader links, connection accessories, mounting hardware, termination, testing and commissioning, complete. (Lauritz Knudsen DU400N/Schneider G40N4A400) |
| 2 | Supplying and fixing 415V, 200A, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse (L&T, Simens) |
| 3 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) (Havells/Polycab/RR Kabels) |
| 4 | 4 core 240 sqmm |
| 5 | 4 core 95 sqmm |
| 6 | 4 core 70 sqmm |
| 7 | Laying of two cables above 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed |
| 8 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. |
| 9 | Supplying & fixing medium gauge 80 MM dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 10 | Supply, Installation, Testing & Commissioning of floor mounted indoor panel cubicle type self-supporting compartmentalized dust and vermin proof MV Panel with separate busbar and cable alleys fabricated from 3 mm thick CRCA sheet steel, having rigid angle/channel iron base frame, complete with necessary interconnections by suitable size copper solid links/bar, cable end terminations, drilling, hardware, ferruling, identification tags, cable glands, removable gland plates, earthing arrangements, internal wiring, powder coated finish (approved shade) and all accessories required for safe and satisfactory operation as directed by the Engineer-in-Charge.(A) INCOMING:(i) 415 Volt, 400 Amp,50kA , 4 Pole MCCB having adjustable(320A to 400A) thermal-magnetic release with extendted Rotary handle and as per system fault level – 1 No. (Make: Siemens/L&T DN3-400N, Cat No. CM94103OOR1OG equivalent of Schneider/ABB)(ii) 415 Volt, 315 Amp, 36kA, 4 Pole On-load Front Operated Changeover Switch – 1 No. (Make:L&T, CO3-315, Cat No-CO33150OOOO or equivalent of Schneider/ABB)(B) BUS BAR CHAMBER:415 Volt, 4 Bar Aluminium Busbar System of 1200 Amp rating complete with suitably sized aluminium busbars mounted on suitable heavy-duty insulating busbar support insulators, including heat-shrink sleeves for phase identification, drilling, fastening, busbar joints, shrouding and all accessories required for safe operation and as approved by the EIC(C) OUTGOING:(i) 415 Volt, 160 Amp,50kA, 4 Pole MCCB, thermal-magnetic release with extendted Rotary handle – 2 Nos. (Emergency Feeders) (Make: L&T, DN2-250N, Cat No. CM92105OOM1OG or equivalent of Schneider/ABB) (ii) 415 Volt, 200 Amp,50kA, 4 Pole MCCB, thermal-magnetic release with extendted Rotary handle – 1 Nos. (Emergency Feeders) (Make: L&T, DN2-250N, Cat No. CM92106OOP1OG or equivalent of Schneider/ABB)(iii) 415 Volt, 160 Amp,50kA, 4 Pole MCCB, thermal-magnetic release with extendted Rotary handle– 3 Nos. (Raw Feeders) (Make: L&T, DN2-250N, Cat No. CM92105OOM1OG or equivalent of Schneider/ABB)(iv) 415 Volt, 63 Amp,36kA, 4 Pole MCCB thermal-magnetic release with extendted Rotary handle – 2 Nos. (Raw Feeders) (Make: L&T, DZ1-160D, Cat No. DZ1F0080DXD1AOOOO or equivalent of Schneider/ABB) |
| 11 | (iv) BUS BAR CHAMBER(For Emergency Power):415 Volt, 4 Bar Aluminium Busbar System of 800 Amp rating complete with suitably sized aluminium busbars mounted on suitable heavy-duty insulating busbar support insulators, including heat-shrink sleeves for phase identification, drilling, fastening, busbar joints, shrouding and all accessories required for safe operation and as approved by the EIC(D) INSTRUMENTS:(i) 0–500 Volt Analog Voltmeter (Make: AE) with selector switch(Make: Kaycee/L&T) – 1 Set(ii) 0–500 Amp Analog Ammeter (Make: AE) with selector switch – 1 Set (Make:Kaycee/L&T) (iii) Current Transformers, ratio 400/5A, Class 1 accuracy suitable for metering – 3 Nos. (Make: Kappa)(iv) DIN mounted MCBs with suitable rating units for instrument and control circuit protection – 3 Nos.(v) LED type phase indication lamps (R-Y-B) complete with wiring and accessories – 3 Nos. (Make: Siemens/L&T)(vi) Danger Notice Board (6” × 4”) – 1 No.The panel shall further include copper control wiring with ferrules and cable markers, internal interconnections, earth busbar, door earthing with flexible copper braid, neutral link, busbar supports, segregation between busbar and cable alleys, nameplates, heat shrink sleeves, nut-bolt-washer hardware, and all other necessary accessories required for complete, safe, and efficient operation, testing and commissioning of the panel as per relevant IS/IEC standards and directions of the EIC |
| 12 | Supplying and fixing double door 8 way Vertical TPN MCB Distribution board for upto 250A MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make: Schinder/Legrand) |
| 13 | Supplying and fixing 200 A, 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Make : L&T/ Schneider/Seimens/ABB) |
| 14 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB 8 Way vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment |
| 15 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/Schinder/Simens) |
| 16 | 125 A FP |
| 17 | 63 A FP |
| 18 | 40 A FP |
| 19 | Supplying and fixing double door 4 way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make : Schinder/legrand) |
| 20 | Supplying and fixing 100 A FP,415 V FP MCB Isolator on din rail of existing DBs and necessary connection (Make : Schinder/legrand/Seimens) |
| 21 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection |
| 22 | 63 TP |
| 23 | 40 TP |
| 24 | 32 TP |
| 25 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 26 | upto 240 sqmm |
| 27 | upto 95 sqmm |
| 28 | upto 70 sqmm |
| 29 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials |
| 30 | 4 core 240 sqmm cable |
| 31 | 4 core 95 sqmm cable |
| 32 | 4 core 70 sqmm cable |
| 33 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required (VTPN to HTPN) |
| 34 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC |
| 35 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 36 | 10 sq mm |
| 37 | 6 sq mm |
| 38 | Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts (For panel earthing & equipment earthing) |
| 39 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required ((For panel earthing)) |
| 40 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. (For panel earthing) |
| 41 | Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil |
| 42 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 43 | Supply and fixing of fabricated tined copper bar duly two Nos hole of suitable dimension as per site requirement having facility for connecting two Nos. lugs of 240 sq mm Al cable to connect with the 400 Amp MCCB termital as per direction of the EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender