Tender For List For Repair Of Damaged Boundary Wall And Upgradation/Renovation Of Sports Stadium Kathua
Tender Value
25.98 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
16 days left
EMD
51960
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for List For Repair Of Damaged Boundary Wall And Upgradation/Renovation Of Sports Stadium Kathua
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: |
| 2 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering . All works upto plinth level 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregates) 40 mm nominal size (crushed) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level using 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level in 1:3:6 mix(1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm nominal size) (Crushed). |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns complete job. |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 9 | Extra for brick work with common burnt clay bricks/cement concrete bricks insuperstructure above plinth level upto floor five level |
| 10 | 12mm cement plaster of 1:6 mix |
| 11 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 12 | Carriage of material from source to site of work by M.T including loading & unloading complete sand and agg for avg Lead of 15 km |
| 13 | Carriage of material from source to site of work by M.T including loading & unloading complete bricks 20 km |
| 14 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto1.5 m in -All kinds of soil. |
| 15 | Filling of good earth including digging loading ,unloading ,royality ,carraige & spreading in proper lines & grades& consolidation with Power road roller complete. |
| 16 | Providing, Fixing,testing and commissioning of white vitreous China wall mounting type water closet including Concealed Cistern of 2 / 4 liter capacity (adjustable to 3/6 liters with CP bolts, nuts, CI chair hanging arrangements, bakelite seat & cover , flush plate , stop cock with CP hinges & rubber buffers, CP brass screw, washer , w.c. connector with all accessories with Rubber Lip / Buffer and side gap filled with silicon sealant wherever required. including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge (Make : Roca code No. RS341730000 & RS346477 / Equivalent in Kohler / Grohe) |
| 17 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 18 | Providing and fixing CP Brass toilet paper holder to the wall of approved design and make as per direction of Engineer-in-charge. (Make Roca Model No. RA816384001 / Equivalent of Kohler / Grohe) |
| 19 | Providing and fixing CP brass health faucet with tube and hook etc. complete as per direction of Engineer-in-charge (Make: ROCA model No. RF9060A1 / Equivalent in Kohler / Grohe. |
| 20 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single Hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 21 | Providing and fixing white vitreous china pedestal for wash basincompletely recessed at the back for the reception of pipes and fittings |
| 22 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms |
| 23 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Flexible pipe 32 mm dia |
| 24 | Providing and fixing S.S.Towel Rail 600mm Long , of approved quality. |
| 25 | Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete |
| 26 | Providing and fixing SS Soap dish |
| 27 | Providing and fixing wall hung gel dispenser of desired pattern including all accessories as per direction of Engineer-in-charge. |
| 28 | Providing and fixing CP Brass Towel Ring etc. complete as per direction of Engineer-in-Charge. (Make: ROCA Model No. RA816711001 / Equivalent in Kohler / Grohe) |
| 29 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms |
| 30 | Providing, Fixing,testing and commissioning of CP brass angle valve with 450 mm flexible coupling pipe for connection with sanitary fixture with CP wall flange, Nut and Washer etc. complete as required. Make: ROCA model No. RF525159800 / Equivalent in Kohler / Grohe. |
| 31 | Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour |
| 32 | Providing and fixing Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per complete as per direction of Engineer-in-charge.For FT & FD of Size 100 mm x 100 mm |
| 33 | Providing and fixing beveled edge 8 mm mirror of superior glass (of approved quality) complete with Spacer & C.P. brass screws and washers complete. |
| 34 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre |
| 35 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110 mm Bend 87.5° |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 15mm nominal outer dia pipes. |
| 37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc25mm nominal outer dia pipes. |
| 38 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour 40 mm nominal bore, weighing not less than 62gms |
| 39 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 40 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 41 | Providing, installing, testing and commissioning of stainless steel body water cooler having 80-litre storage capacity complete with commercial RO / filtration system of minimum 50–100 LPH capacity, comprising 20″ sediment filter, activated carbon filter, micron cartridge filter, RO membrane, booster pump, automatic voltage stabilizer (copper wound, wall mounted, single phase) with input range of 90–240 V, minimum two numbers stainless steel taps, 500 litre capacity water storage tank, M.S. frame and platform, complete with all fittings, accessories, inlet and outlet connections, electrical wiring, and making good the site as required, complete job.. . |
| 42 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.: Medium 25 mm dia. nominal bore |
| 43 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc. Medium 20 mm dia. nominal bore |
| 44 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore |
| 45 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete25 to 40 mm nominal bore |
| 46 | Supply of 1 inch plexible pipe of superior quality idle for both hot & cold condition as per the direction of engineer incharge of length 85-90 feet per bundle. |
| 47 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 48 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 49 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 50 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet |
| 51 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 52 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 53 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 54 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 55 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 56 | Supplying and fixing 63 amp SPN rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 57 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp |
| 58 | Providing and fixing of 4 core Service line 10sqmm |
| 59 | Supply, Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm dia sweep ceiling fan all job complete as per direction engineer incharge |
| 60 | Supply, Installation, testing and commissioning of angle holder including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as requiredall job complete as per direction engineer incharge |
| 61 | Installation testing and comissioning of LED Cove lights with necessary driver for LED cove light with lamp lifr of 35000 hours, colour temperature of 3000k and CRI>80 |
| 62 | Supply, Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. light Bulb 9 watt |
| 63 | Installation testing and comissioning of linear surface wall mounted 20 watt light luminaire with Luminous efficiency of luminaire 100 lm/W; color rendering index Ra > 80; minimum system lumen output of 4000 lumens and maximum system wattage of 12W; Dimension :- 595 mm Body of extruded aluminium profile and polycarbonate cover. |
| 64 | Installation testing and comissioning of linear surface wall mounted 36 watt light luminaire with Luminous efficiency of luminaire 100 lm/W; color rendering index Ra > 80; minimum system lumen output of 4000 lumens and maximum system wattage of 12W; Dimension :- 1200 mm Body of extruded aluminium profile and polycarbonate cover. |
| 65 | Installation, testing and commissioning of 200 mm sweep exhaust fan with robust motor, gravity shutters with speed rating of 1350 revolution per minute complete with all accessories etc. directly on ventilator , including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 66 | Installation, Testing and commissioning IP 66 Flood lights 200 watt minimum Luminous flux of luminaire 120 Lm/w, Colour temperature of 5700K, Neutral white, CRI > 80, 50,000 operating hours and necessary wire for connection and other accessories required for fixing lights on existing Poles. Firm has to submit originallity certificate of material from OEM or Authorized |
| 67 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) 100 Amp, 30 KA, FP MCCB ICU = 100% ICS |
| 68 | Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 25 sq. mm 3.5 core |
| 69 | Supplying, installation, testing and commissioning of Cubical type Indoor/Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 wire 50 Hz AC supply system with provision for housing incomers, Out Going, COS, Bus Bars etc. as required but excluding the cost of MCCB's, Bus Bars and Change over as per the following Description (IP:42) General Floor Distribution Panel. The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A drawing wiring diagrams, single line diagram before start of fabrication of LT panel Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating. The panel Builder shall be CPRI/ERDA/ANY NABL ACCREDITED LAB approved. |
| 70 | P/F of connection box Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer