Tender For Construction Of (S+7) Storied Building Near Mhi For Infrastructure Of Centre Of Competence, Scb Medical College And Hospital, Cuttack.

Issued by Government Departments · Cuttack, Odisha
Tender Value
13.67 Crore
Estimated cost
Bid Submission
22 Sep 2026
9 days left
EMD
13.68 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Cuttack → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of (S+7) Storied Building Near Mhi For Infrastructure Of Centre Of Competence, Scb Medical College And Hospital, Cuttack.

BOQ

Name of Work:- Construction of (S+7) Storied Building near MHI for Infrastructure of Centre of Competence, SCB Medical College and Hospital, Cuttack.
Sl. No. Item Description
1CIVIL WORKEarth work in excavation IN ALL TYPES OF SOILS by manual means overareas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) inculding disposal of excavated earth up to 50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.
2Earth work in excavation IN ALL TYPES OF SOILS by manual means overareas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) inculding disposal of excavated earth up to 50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.+1.5m extra lift
3Providing 375mm dia and 6.0m long, single under reamed bored compaction Pile with M-25 grade concrete including cost of boring to required dia meter and depth to plumb and taking precautionary measure against collapsing of side soil due to presence of water table using bentonite powder etc., concreting and driving the cage made of M.S. / T.S. steel as per approved drawing into the freshly laid concrete vertically by means of power winch to requied depth but excluding cost of M.S. / T.S. steel and labour charges for cutting, bending and binding of steel etc. complete confirming to IS-2911 specification including necessary routine tests including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the specification and instruction of Engineer-in-Charge.
4For each additional depth of 0.50m beyond initial depth of 6.0m up to 10m add extra to the rate Per 1 Pile
5Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge.
6Disposal of surplus excavted materials by mechanical means from the work side etc. complete. upto 5km. Lead including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge.
7Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.
8Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.
9Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. In RCC in Pile cap
10RCC in Tie Beam
11RCC in Lift wall upto PL
12RCC COLUMNStilt Floor
13First Floor
14Second Floor
15Third Floor
16Fourth Floor
17Fifth Floor
18Sixth Floor
19Seventh Floor
20Terrace Floor
21RCC ROOF BEAMStilt Floor
22First Floor
23Second Floor
24Third Floor
25Fourth Floor
26Fifth Floor
27Sixth Floor
28Seventh Floor
29Terrace Floor
30RCC ROOF SLABStilt Floor
31First Floor
32Second Floor
33Third Floor
34Fourth Floor
35Fifth Floor
36Sixth Floor
37Seventh Floor
38Terrace Floor
39RCC STAIRCASEStilt Floor
40First Floor
41Second Floor
42Third Floor
43Fourth Floor
44Fifth Floor
45Sixth Floor
46Seventh Floor
47RCC WALLStilt Floor
48First Floor
49Second Floor
50Third Floor
51Fourth Floor
52Fifth Floor
53Sixth Floor
54Seventh Floor
55RCC LINTELStilt Floor
56First Floor
57Second Floor
58Third Floor
59Fourth Floor
60Fifth Floor
61Sixth Floor
62Seventh Floor
63Terrace Floor
64RCC SILLStilt Floor
65First Floor
66Second Floor
67Third Floor
68Fourth Floor
69Fifth Floor
70Sixth Floor
71Seventh Floor
72Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.In Foundation
73Stilt floor
74First floor
75Second Floor
76Third Floor
77Fourth Floor
78Fifth Floor
79Sixth Floor
80Seventh Floor
81Terrace Floor
82Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
83Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.Stilt floor
84First floor
85Second Floor
86Third Floor
87Fourth Floor
88Fifth Floor
89Sixth Floor
90Seventh Floor
91Terrace Floor
92Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Stilt floor
93First floor
94Second Floor
95Third Floor
96Fourth Floor
97Fifth Floor
98Sixth Floor
99Seventh Floor
100Terrace Floor
101Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Stilt floor
102First floor
103Second Floor
104Third Floor
105Fourth Floor
106Fifth Floor
107Sixth Floor
108Seventh Floor
109Terrace Floor
110Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.Stilt floor
111First floor
112Second Floor
113Third Floor
114Fourth Floor
115Fifth Floor
116Sixth Floor
117Seventh Floor
118Terrace Floor
119Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.Stilt floor
120First floor
121Second Floor
122Third Floor
123Fourth Floor
124Fifth Floor
125Sixth Floor
126Seventh Floor
127Terrace Floor
128Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).Stilt floor
129First floor
130Second Floor
131Third Floor
132Fourth Floor
133Fifth Floor
134Sixth Floor
135Seventh Floor
136Terrace Floor
137Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.(Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge).Stilt floor
138First floor
139Second Floor
140Third Floor
141Fourth Floor
142Fifth Floor
143Sixth Floor
144Seventh Floor
145Terrace Floor
146Supplying and fixing of MCM Modified Clay Material- MCM Slate Stone Sunnye 1200 x 600mm thickness 2.5mm, as per company standard dimension, pattern, color as specified, manufactured through unfired patented (Ref US patent 8505840 82 & European Patent 2157139) anufacturing technology, bonded together by using low heat temperature and having CE approval with the thermal conductivity of 0.0590 W/M.K - EN 12667 (2001), thermal resistance of 0.0568 M2 K/W- EN 12667 (2001) and Fire Insulation - Class A-ASTM E84-15. The product should be patented from United States and Europe and with certifications by IGBC. MCM Materials should be fixed with suitable Cement/ Polymer/Epoxy based adhesive as per adhesive chart and Substrate and per directions of Engineer in-charge. Grouting should be done using filing and pointing method as per instllation drawing provided, and colour of the grout should be as per the architect's specification depending on the substrate and as per the direction of Engineer in-charge.
147Providing Double Charged vitrified tile flooring using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 1200x600 (homogeneous) of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. Stilt floor
148First floor
149Second Floor
150Third Floor
151Fourth Floor
152Fifth Floor
153Sixth Floor
154Seventh Floor
155Providing Double Charged vitrified tile using having thickness of min 10mm conforming to IS 13755 of 1200x600 (homogeneous) of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as directed by the Engineer in charge.Stilt floor
156First floor
157Second Floor
158Third Floor
159Fourth Floor
160Fifth Floor
161Sixth Floor
162Seventh Floor
163Fixing granite Stone Mat finished of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge.Stilt floor
164First floor
165Second Floor
166Third Floor
167Fourth Floor
168Fifth Floor
169Sixth Floor
170Seventh Floor
171Fixing granite stone of approved dimension area above 0.4 sqm (20mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.Stilt floor
172First floor
173Second Floor
174Third Floor
175Fourth Floor
176Fifth Floor
177Sixth Floor
178Seventh Floor
179WOODEN PANELLING WITH VEENERProviding, fitting and fixing full height wooden paneling to walls and columns wherever necessary from floor Ivl to celling ht or as per drawing/design made out of 50.8mmx25.4mmx1.34mm thick Aluminum rectanqular sections placed @ 600mm c/c both ways on old, on top of grid 12mm fire resistant and termite proof ply conforming to IS code :5509) to be provided with 4mm thk veneer of approved shade and colour fInished with melamine pollsh as per design/drawing or as directed by the ArchitectEngineer-In- Charge. The rate Includes cost of cutouts for electrical switches, Ilght fixtures, wall bracket fans if any,all complete with materials, labour, T&P, taxes etc. (Make: Anutone or equivalent)
180Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.Terrace Floor
181Providing and application of Polyurethane waterproof coating after proper surface preparation and application of primer: Single component liquid applied Elastomeric based waterproofing system should be of thickness of 1.5mm as directed by the engineer in charge. The formed membrane should have properties equal or more than at 28 days Elongation: 450 % confirming to ASTM D412 Tear resistance: 10 N confirming to ASTM D624 Shore hardness: 80 confirming to ASTM C 836100% Modulus Elongation: 0.6 MPa(ASTM D 412)Recovery from 200% elongation: (ASTM D 412): > 80%No cracking or tearing: Extensibility after heat ageing(ASTM C 836) etc. as per direction of E.I.CTerrace Floor
182Surfaces should be clean, and free from loose particles, curing membrane or any other contaminant. Grease, oil, mound release agent, loose and flaking paint, rust, algae, fungus or any other material which may impair adhesion and such other contaminants must be removed by mild detergent, thoroughly scrubbing with a soft brush, and then clean with water. If the wall surface is damp or water is seeping leakage, it is necessary to treat the leakage before coating. Apply Ultra Coat (SRI 105) by a roofing brush or with Medium nap lamb’s wool roller on the cleaned and washed surface. The second coat to be applied after a gap of min. 6 hrs. To ensure optimum performance apply the second coat at right angles to the first coat. (Make:MYK Arment AquaArm Ultra Coat/Fosroc BRUSHBOND ROOF GUARD/MAPEI Aqua Flex Roof HR/ Equivalent).Terrace Floor
183Providing and fixing of 2 hours CBRI/UL Certified or 2 Hours Spectro Certified having 40 Mins of Insulation Fire Rated door with Single/Double leaf shutter of 46 mm thickness made of 0.8/0.9/1.0/1.2 mm thick skin pass GI Sheet and 1.2 /1.6 mm thick GI sheet for frame conforming to IS 277 with radius of 1.4 mm with minimum 120 gsm of Zn Coating to provide rust resistance. The Internal construction of the door is a specially designed Honeycomb or Rockwool at top, bottom and stile surrounds. The door shutter and frames are primed with Zn Phosphate Stoving primer and finished with Pure Polyester powder coating of thickness not less than 60 Micron. Wood finish through Heat transfer over and above this can be provided as per the directions of Engineer-in-charge. (Make; TATA/Unistar/Doorwin)
184HIESTEEL or equivalent Aluminum Sun Louvers 84R system comprises of 84 mm wide and 16 mm deep rolformed out of aluminum coils. In Aluminum, Panels are made of 0.5mm thick aluminum alloy 3105/3005 and Carriers are made of 0.9mm thick aluminum alloy with cut-outs to hold panelsAluminum panel and carrier shall be polyester powder coated with 60-70 microns. HI-STEEL Sun louver system is a vertical or horizontal wall sun shading system. The system use 84 R panels that snap into vertically mounted frames. The frames can be mounted on the exterior of a building over window openings, along balconies or over open area on a building elevation. Thevertical/horizontal frames are offered in two different designs that hold the panels at different angles of 35 and 45 degrees. The ranges of angles provide air flow, sun shading safety from rainfall and desired visibility.
185NCL LOUVERED VENTILATORS Supply and fixing of pre-painted NCL Seccolor Louvered Ventilators And Louvered Ventilators With Fixed windows made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D\\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 33 x 57 mm Box Section for mullion 33 x 57 mm, and section for beading should be 12 x 25 mm with 4 mm pinhead glass for ventilators with Ethyl propylene Damien monomer Gasket (EPDM) and the sections cut to length mitre joined with corner bracket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws complete for finished item of work.Fixed louvers 4'-0\\" x 2'-0\\" (1219.2 x 609.6 mm) (Box section) outer frame section size of 33 x 57 mm Mullion section size of 33 x 57 mm.
186Single Glazed 2 Track 2 Panel /3 Track 3 PanelSystem Aluminum Sliding Window & Doors :-Providing and fixing Casement systems Aluminum works for Sliding doors and windows with 50mm &35mm visible aluminium section width in the centre mullion. The extruded aluminium sections should bemade from Grade 6063-T5 & Vertically Anodized with Texguard coating. All profiles should be Non insulated Profiles with mosquito mesh fitment provision track. Corner connection will be Butt joint with Screw using Nano gaskets for sealing. All other major Accessories should also be made by the same manufacture. All Slider doors & windows will be centre locking and all hardware shall be concealed within the system profiles. Integrated Anti-lift in slider panel, EPDM gaskets should be used in slider windows & doors in all meeting points instead of Brush Pile. The outer frame Depth will be 72mm. All materials which are used should be corrosion-resistant so that they are good functioning in different environments and that there are no negative influences either on the aluminium or on the surface treatment. The system should allow the application of glazing (Make- Guardian glass/Saint gobain/equivalent) or panels with thickness upto 8mm with clear toughened single glazed units. The external perimeter of aluminium sections should be Anodized with Texguard coating, the system should qualify Airtightness ASTM E283: 10.7m3/h.m2 at 75Pa of pressure, Water tightness ASTM E300: 240 Pa, Wind load resistance ASTM E330: 1600 Pa. System should have a 10-year warranty on properties, functionality and design, within restrictions defined by technical specifications of anodizing & 1-year warranty on wearing parts only applies to normal and realistically foreseeable use. All Slider doors & windows will be with Crescent center locking handles only.
187Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL ).
188E.I. WORKRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( anti-bactorial and flame retradant type) switch ISI marked Make-Schneider(Zencelo)/ legrand( Myrius-Next gen) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( anti-bactorial and anti-bactorial and flame retradant type) Make-Schneider(Zencelo)/ legrand( Myrius-Next gen) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. Group A
189Group B
190Group C
191Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti-bactorial and flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-Next gen) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
192Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti-bactorial and flame retradant type)) with suitable size modular box & cover( anti-bactorial and flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-Next gen) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
193Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius-Next gen)/-Schneider(Zencelo)/PANASONIC(VISION)
194Supplying,fixing of 1x6A+1X16A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial and flame retradant type) with suitable size modular box & metallic cover plate (both side)( anti-bactorial and flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
195Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( anti-bactorial and flame retradant type)) with suitable size modular box & cover( anti-bactorial and flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-Next gen)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(Make :Legrand(Myrius-Next gen)/-Schneider(Zencelo)/PANASONIC(VISION)
196Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( anti bactorial &flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( Myrius-next gen) /Panasonic (vision) . (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
197Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
198Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
199Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
200Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
201Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI/ V-guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ BEC/ Precision/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
202Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)-20 MM
20325 MM
204Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision)as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
205S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
206Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LDB, UPSDB)
2078 Way(8+(4x3)+(3x8)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-24 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR PDB)
208Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year..
209Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 /ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
210Supplying and fixing 40 Amps rating, dp, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
211Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
212Supplying and fixing 63Amps 2P 240 volts RCCB 30 mA Make- LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The RCCB should be Replacement Warranty will be 1 year
213Supplying and fixing 40Amps 2P 240 volts AFDD(arc fault detection device) Make- ABB S ARC1 M/ Equivalent model of Schneider/ Legrand/ Siemens ,10KA,C,IEC-62606 for arc fault in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year
214Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board, Make-LEGRAND/ Siemens/ Schneider/ OBO/ DEHN in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 1 year.
215Fittings & Fixtures-Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.
216Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 -50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) .
217SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)
218Supply, installation, testing and commissioning of LED Design based BIS approved LED Street Light with system power of 90W, CCT in 5700K as per ANSI) ,CRI>70, SDCM<3 , LEDs used should have a life of 50,000 burning hrs. & Lumen maintenance as per L70. The Luminaire System lumens should be >=11,700 Lumens @5700K. The fixture housing must be Made of ADC 12 PDC Aluminium housing for rapid thermal healing & Powder coated by Corrosion resistant Nano coating technology. Luminaire must have a Ingress protection of IP66 and Impact Resistance of IK08. The light engine should use Metal Core PCB with high grade aluminium (AL5052) and should have a thermal conductivity of >2W/mK. The fixture should have an UV stabilized Injection moulded special PC lens optics(Glass not allowed) ensuring low glare & best in class uniformity. The light and the driver compartment should be thermally isolated by a natural airgap. Luminaire housing and optical compartment both should carry OEM's logo embossed / engraved (no stickering is allowed). The luminaire must have Integral encapsulated high efficiency electronic thermally isolated driver having a Aluminium extrusion construction with rated voltage of 100-300V, power factor > 0.95, THD < 10%, with Inbuilt surge protection of min 6KV and upgraded with integrated IP67 protected SPD of 20KV/10KA surge protection with all necessary safety protection like mis-wiring, Over voltage, Short circuit, Reverse Polarity protection. . The compartment should be bottom openable for ease of maintenance at site. Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. Following documents to be submitted after award of contract: Luminaire and Driver TDS, Photometry report, Type test certificate, IP, IK, Vibration and salt spray test certificates from NABL accredited Laboratory, LM80 from LED OEM., CE Certification, ROHS compliant, BIS Certificate for Luminaires & Drivers. The warranty on light fixture shall be 5 years. (Make: PHILIPS/WIPRO/BAJAJ/Crompton/PANASONIC/LT/HAVELLS)
219Supply, installation, testing and commissioning of double sided visible LED illuminated Exit Indication Sign(300 mmx 150 mm, letter height minimum 150 mm) complete with directional arrow legend, rechargeable maintenance-free battery backup capable of providing continuous illumination for not less than 90 minutes upon mains failure, automatic charger circuit, fire-retardant ABS housing, polycarbonate diffuser, minimum letter height 150 mm, suitable for 230V AC supply, wall/ceiling mounting arrangement, complete with all accessories, wiring connections, testing and commissioning as required. The equipment shall comply with applicable requirements of NFPA 101, NFPA 70 and UL 924 standards.The Exit Indication Sign shall be a self-contained, LED-illuminated unit with integrated rechargeable battery backup, directional arrow (left, right, or straight), and automatic changeover circuitry. The sign shall operate in maintained mode (continuously illuminated) or non-maintained mode as specified, and shall automatically switch to battery power upon mains failure. The pictogram shall comply with ISO 7010 (E001 / E002 green running-man symbol) as mandated by NBC 2016 and IBC 2021. Make-Bajaj/Prolite
220SITC of 1000 Lumen/10W LED Bulkhead wall fitting (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
221Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
222Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible)
223Supplying, installation, testing and commissioning of wall mounted 400 mm sweep fan including earthing etc as required as per direction of Engg.-in-Charge,Replacement Warranty will be 5 years. (Make : Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells).
224S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make-Schneider(Zencelo)/ legrand( Myrius-NEXT GEN)/ Panasonic (vision)
225Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
226Supply , installation, testing and commssioning of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee/Valmount as per direction of Engg. in Charge.
227Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge.
228PANEL DISTRUBUTION-S/I/T&Commissioning of Main LT indoor floor mounted CPRI Tested cubical type Main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. 80X10MM Separate Aluminium Earth bus bar should be installed.All the incomers shall have 65 kA 3P+N type 1+2 SPD with125A 4P MCCB, 25Ka MCCB with TMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) Make of SPD -LEGRAND / Siemens/ Schneider/ABB/OBO/Dehn. Mandatory provision of cable alley is to be given. ON/OFF/TRIP indication shall be given for all the feeders.Incomer- 01 no 800A 4P MCCB 36kA with LSIG Microprocessor release with Ics=100%Icu ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula)Busbar- 04 numbers of 900Amps Aluminium busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.630A 4P Auto manual changeover - 1 setOutgoing: 01 no 400A 4P MCCB 25kA with LSIG Microprocessor release with Ics=100%Icu, 03 nos 250A 4P MCCB 25kA adjustable thermal based, Ics=100%Icu, 10 nos 125A 4P MCCB, adjustable thermal based, Ics=100%Icu 25kA , 02 nos 160A 4P MCCB, adjustable thermal based, Ics=100%Icu 25kA, 10 nos 100A 4P MCCB, 25 kA adjustable thermal based, Ics=100%Icu , 8 nos 63A 4P MCCB 25kA with TMR based release with adjustable overload ,Icu=100%Ics, . Make-LEGRAND-DPX3/ Siemens-3VA/ Schneider- CVS/ ABB FormulaInstrument- (i) phase indicating lamp with toggle switch & HRC fuse in all the incomersAll the outgoing feeders shall have digital ammeter with suitable rating of Class 1 CT as per the feeder rating.(ABB/Schneider/Siemens/Legrand)(iii) All the incoming feeders shall have digital multifunction meter(V+A+F+KwH+KVAR+KVAH+THD)
229FLOOR LIGHT PANEL:(1F TO 7th Floor) S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. Mandatory provision of cable alley is to be given. Incomer:100A 4P MCCB, 25 kA adjustable thermal based, Ics=100%Icu Bus bar: 4 nos. 150 A Aluminum Busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing : 5 Nos 40A 4P MCB, C series. (10 KA) for LDB , MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB formulaMake of MCBs- LEGRAND-DX3/Siemens-Betaguard/Schneider-Acti-9/ABB SB200Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB) with CTs 100/5A 3 nos class 1 type
230FLOOR Power PANEL:(1F to 7th Floor) S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer.Mandatory provision of cable alley is to be given. Incomer:125A 4P MCCB, 25 kA adjustable thermal based, Ics=100%Icu Bus bar: 4 nos. 200 A Aluminum Busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing : 5 Nos 63A 4P MCB, C series. (10 KA) for LDB , MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB formulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard/Schneider-Acti-9/ABB SB200Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB) with CTs 150/5A 3 nos class 1 type
231FLOOR UPS PANEL:(GF to 7th Floor) S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication. Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. Mandatory provision of cable alley is to be given. Incomer:63A 4P MCCB, 16 kA adjustable thermal based, Ics=100%Icu Bus bar: 4 nos. 100 A Aluminum Busbar duly sleeved Instruments: 1 set.LED type phase indicating lamps with control fuses Outgoing : 5 Nos 40A 4P MCB, C series. (10 KA) for LDB , 1 Nos 63A 4P MCB, C series. (10 KA)MAKE OF MCCB- LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB formulaMake of MCBs- LEGRAND-DPX3/Siemens-Betaguard/Schneider-Acti-9/ABB SB200Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)(ii) 01 set of 3 ph digital type Voltmeter(Make-Siemens/Schneider/ABB).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Siemens/Schneider/ABB) with CTs 100/5A 3 nos class 1 type
232UPS O/G PANEL : S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for EMERGENCY circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.. 20X10MM Separate Aluminium Earth bus bar should be installed. All the feeders shall have ON/OFF/TRIP indication.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. Mandatory provision of cable alley is to be given. Incomer- 01 no 160 A 4P MCCB 25kA ,adjustable thermal, Ics=100%Icu with on/off trip indication Light load for each floor. Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 Busbar- 04 numbers of 250Amps COPPER busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.Out going- 10 nos. 63A 4P MCCB, 16 kA adjustable thermal based, Ics=100%Icu Instrument- (i) 3 numbers phase indicating lamp for R,Y,B inndication with 2A SP MCB,C,10KA. ( Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)(ii) 01 set of 3 ph digital type Voltmeter(Make-Legrand/Siemens/Schneider/ABB).(iii)01 set of 3 ph digital type Ammeter(0-200)A(Make-Legrand/Siemens/Schneider/ABB) with CTs 200/5A 3 nos class 1 type(iv) All the outgoing feeders shall have provision of digiatal ammeter of class 1 accuracy of suitable rating.
233SITC of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder coated paint is designed as G.A drawing. (FOR LIFT)as per direction of Engg.-in-Charge. Warranty period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.Provision of 40kA 3P+N type 2 SPD alongwith 63A, 4P, MCB, C series, 10kA is to be given in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. 63amp panel board having 63A Amp 16KA 4P MCCB TMR based release with adjustable overload ,Icu=100%Ics as incommer, 100 amp electrolyte Aluminium bus ba-1 Set, 63A Amp 4P RCCB 30mA- 1 No,25A Amp DP RCCB 30mA- 2 No,6-32A DP MCB 10ka, c series -2 No as Outgoing with ampere meter, voltmeter, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make of mccb :-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB FORMULA) Make of MCB-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(Lift Panel)
234AC VRF OUT DOOR PANEL-S/I/T&Commissioning of CPRI Approved LT OUTDOOR,IP 66 floor mounted cubical type electrical main panel (for AC ODU) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.3P+N Type 2 40 kA SPD with 63A rating,10KA breaking capacity ,4P MCB shall be installed in the incomer.40x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication.Incomer 1- 01 no 250A 4P MCCB Icu=100% Ics,,25Ka MCCB with TMR based release with adjustable overload ( Make-LEGRAND DPX3/ Siemens 3VA/ Schneider CVS/ABB FORMULA).Busbar- 04 numbers of 300Amps al busbar with current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)Outgoing- 5 nos 63A 4P RCBO,300MA. ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.(ii) 01 set digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication
235CABLING AND END TERMINATION -Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/ Polycab/ HAVELLS/ RR KABLE/ KEI/ Glosterof following size cables as per direction of Engg.-in-Charge. 3.5core x 300 sq mm
2363.5core x 185 sq mm
2373.5core x 70 sq mm
2383.5core x 50 sq mm
2394core x 16 sq mm
240LAYING OF CABLE-Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as required.Upto 25 sq. mm
241Above 25 sq. mm and upto 120 sq. mm
242Above 120 sq. mm and upto 400 sq. mm
243Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade following size direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.Upto 25 sq. mm
244Above 25 sq. mm and upto 400 sq. mm
245Laying of One No. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing On Wall Surface(Clamped with saddle/ PVC & UPVC Pipe)/ CableTray as required.Upto 25 sq. mm
246Above 25 sq. mm and upto 120 sq. mm
247Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x300 sq mm
2483.5 core x185 sq mm
2493.5 core x70 sq mm
2503.5 core x50 sq mm
2514 core x16sq mm
252Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia
253Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 200 mm dia
254Supply ,installation ,testing & commissioning of 80KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 100AH, 60 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric / APC/ VERTIV) LOAD ) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD.
255LIGHTNING PROTECTION SYSTEM-Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
256Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB
257Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB
258Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB
259Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ). Make-OBO/Dehn/ABB
260Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
261Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB
262Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB
263Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB
264Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB
265Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB
266Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB
267Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB
268Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB
269Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB
270Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB
271Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB
272Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB
273Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB
274Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
275EARTHING SYSTEM-Copper earthing should be only for UPS and DG neutral earthing only and all other are GI plate earthing.-Supply & Fixing of Copper plate Earthing (600 x 600 x 3mm thick) including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.( For Online UPS only 2nos each)
276Providing and fixing 25 mm X 5 mm dia copper strip on wall/surface or in recess for connection etc. as required.
277Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
278Providing and fixing 50 mm X 5 mm dia G.I strip on wall/surface With required DMC insulator and nut bolt connection etc. as required.
279Providing and fixing 25 mm X 5 mm dia G.I strip on wall/surface With required DMC insulator and nut bolt connection etc. as required.
280HVAC WITH ACCESSORIES-CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER-Supplying,fixing of perforated cable trays with cover, horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 600mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
281Supplying,fixing of perforated cable trays with cover, horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
282Supplying,fixing of perforated cable trays with cover, horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
283Supplying,fixing of FLOOR RACE WAY GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE-Legrand/ Profab/OBO/Neidax .(With all accessories,bend,cover,supporter) as required as per direction of Engg.-in-Charge.
284Supplying,fixing of 8 module under- FLOOR outlet box IP20, size not less than 308mmx308mm as required as per direction of Engg.-in-Charge.MAKE- Profab/OBO/Neidax/Legrand
285VRF System with indoor and outdoor unit-Supply,Installation, Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s) microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at 49°C ambient temperature without tripping. The unit shall be suitable to work on 380-415 V, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads.The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, automatic refrigerant charging,blue fin treated condensor coil for corrosion resistant, auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. .The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units.ISEER should be greater than equal to 7.4 for cooling capacity less than 40kWr, ISEER should be greater than equal to 7.5 for cooling capacity more than equal to 40kWr and less than 70kWr and ISEER should be greater than equal to 7.6 for cooling capacity more than equal to 70kWr.The deration chart of outdoor from factory head should be submitted before procurement.Make: Mitshubishi(MultiCity Y Series)/O-GENERAL(VC-V)/Daikin(Alpha) Outdoor Unit of Nominal Capacity -20HP
286S/I/T/C of ODU Connecting Kit. Make: Mitshubishi/ O-GENERAL/Daikin
287Supply, Installation,Testing and Commissioning of following minimu capacity 4-way VRV Cassette Type Indoor ceiling mounted unit equipped with cord less remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation,fire resistant metal box protection for indoor unit PCB etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. The cost is inclusive of Refnet joints. Make: Mitshubishi/ O-GENERAL/Diakin Nominal Capacity- 1.5 TR
288Nominal Capacity- 2.01 TR
289Nominal Capacity- 3.18 TR
290Supply of Gas Charging for the entire circuit(R410A)
291Supply, installation, testing ,assembly at site and commissioning of outdoor type DOUBLE SKIN FLOOR MOUNTED AHU of horizontal / vertical arrangement, draw through type with sectionalised construction suitable to be assembled at site as per EN 1886 Construction Details: Double-skinned panels shall be 50 ± 2 mm thick with thermal break construction and made of galvanized steel skins, pressure injected with PU foam insulation having density 40 kg/m3 with a K factor not exceeding 0.022 Watt/Mc internal structural framework with high speed steel screws. Outer sheet of panels shall be made of pre-painted, of 0.8 mm thick, and inner sheet of 0.6 mm G.I. Sheet. The entire framework shall be assembled in modules & mounted on a galvanized steel (depending on size) channel base as per manufacturer’s recommendation. All panels to have doors except for the coil section & to be openable on the outside.Drain pand shall be strictly inside the AHU casing PU panel and not to be exposed to environment. Mixing Section: The AHU shall be provided with mixing chamber section. The mixing box shall have a manually operated return air and fresh air damper of Low leakage Aerofoil design, with concealed (Nylon gears / linkage type) Anodized Aluminum construction in the mouth piece Pre Filter Section:The AHU shall be provided with synthetic (non woven) filter section with 50 mm thick filters fitted on aluminium frame capable of filtering 90% down to 10 micron (MERV-8) washable type filters as per EN 779 Note: The AHUs should be supplied with a pair of pre-commissioning filters which will be replaced by the actual filters during commissioning Fine Filter Section:The AHU shall be provided Fine filter section containing Synthetic 300 mm Bag, class F7, equivalent to EU7 (MERV 13) of ASHRAE 52.2 1999 .The efficiency of the filters shall be 95% down to particle size of 5 microns as per EN 779. Differential pressure measuring port to check filter efficiency all complete as required The performance of air handling units should be tested in a Eurovent-accredited laboratory.The AHU technical data sheet shall be submitted for coil/fan performance from certified software output individual component selection not be considered.One AHU for the project will be factory tested for air performance CFM / Static / Power / Motor KW / Sound/Vibration, prior to dispatch.Air handling unit shall be selected for the lowest operating noise level i.e. not exceeding 65 dbA @ 1.5 metre distance from the equipment. Mechanical Characteristics as per EN 1886: a. Casing Strength Classification: D1 b. Casing Air Leakage: L1 c. Filter Bypass Leakage: F9 d. Thermal Transmittance: T2 e. Thermal Bridging Factor: TB2 Air Handling Unit Performance as per EN 13053 Coil Section: Cooling coil of 6 row copper tube. The coil shall be EUOROVENT certified as per EN 1216. The header shall be made of copper and the end caps of MS. The tube shall be of copper and shall be 0.4 mm thick and 12.5 mm diameter. The fins shall be of aluminium of 0.11 mm thickness with spacing of 10-11 FPI and shall be coated with anticorrosive hydrophilic blue colour coating. The coil shall be minimum 6 row deep or shall be designed as per the load requirement and the area shall be selected for a maximum face velocity of 2.5 m/s. (Selection sheets need to be provided for approval) Fan Section: Eurovent certified direct driven aerofoil design blade plug fans of high efficiency as per EN 5801. The fan shall be selected for an outlet velocity of not more than 9 m/s. The fan should be selected to ensure that it operates within the optimum range when the speed of fan shalll be 40% to 150% of motor RPM. For capacities till 9000 cfm single fan can be used. For capacities between 9000 cfm to 14000 cfm single / two fans can be used. However for capacities above 14000 cfm, multiple fans to be used.Motor Section: The AHU shall be provided with AC motors of high efficiency. Motor shall be 415±10% volts, single / three phase as suiting the airflow range, TEFC, with class F insulation with IP 55 protection for AC Motors. Motors shall be specially designed for quiet operation. The motor should be variable speed type & driven by VFD for AC motors.Motor Winding shall be VPI coated.Drain Assembly: 20G SS 304 drain pan to be installed strictly inside the AHU. Drain pan installation outside the PU panel casing is not allowed. Air moving capacity, cooling capacity and external static pressure ESP) excluding pressure drop across filter, coil and fan sections shall be according to the enclosed AHU details.The rate is inclusive of VFD panel.IP 20 rated VFD to be placed inside the starter panel with IP-55 enclosure.Each VFD panel to be provided with digital display showing electrical parameters like voltage, current and power consumption.At the time of odering ahu total pressure loss as per friction method and ahu coil selection should be submitted for approval. Make- VTS/Trane/Systemair6TR 2500 CFM 6RD, ESP-80MM, FM AHU
292Supply & Fixing of Cooled Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata)22 GAUGE
29324 Gauge
294Supply,installation,testing and commissioning of duct thermal insulation of Following Capacities , Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline . - with 25mm thick Nitrile Rubber Class O fire rated Insulation insulation conforming to BS476 Part6 and part 7 to provide the sufficient mechanical protection. The fibre glasscloth shall be factory laminated. The adhesive shall be SR 98 or equivalent sourced from OEM of nitrile rubber insulation.
295Supply ,& Fixing of Accoustic Class O fire rated Insulation insulation conforming to BS476 Part6 and part 7 15 mm thick of Armasound open cell nitrile rubber Make of insulation- K Flex/ Armacell/ Vidoflex/ Eurobatex/ Isoline
296Supply ,& Fixing of Flexible WATERPROOF FIRE RATED canvas connection in complete as per the direction of Engineer-in-charge.
297Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser with VCD having flange all around.Make-Glenstorm/Airflow/Systemaire
298Supply, erection, testing & commissioning of Aluminium powder coated grills/diffuser without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire
299Supply,installation,testing and commissioning of 0.6 mm Aluminum cladding on Outdoor Ducts. Make-Hindalco/Balco/Nalco
300Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular insulation between each set of indoor & outdoor units . The pipe dia upto 25 shall be soft seamless & above 25mm dia shall be hard seamless . All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in GI. cable tray etc. as reqd. Make of insulation-K Flex/Armacell/Vidoflex/Eurobatex/Isoline Make of pipe-Rajco/Mandev/Maxflow 34.9 mm with 1.21 mm thick
30128.6 mm with 1.00 mm thick
30222.2 mm with 0.8 mm thick
30319.1 mm with 0.8 mm thick
30415.9 mm with 1.00 mm thick
30512.7 mm with 0.8 mm thick
3069.5 mm with 0.8 mm thick
3076.4mm with 0.8 mm thick
308Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular insulation between each set of indoor & outdoor units . All external piping(which are exposed to external environment such as terrace etc.) shall be provided with factory laminated GC Cloth & then shall run in perporated hot dip galvanized GI. cable tray with cover etc. as reqd. Make of insulation-K Flex/ Armacell/ Vidoflex/ Eurobatex/ Isoline Make of pipe-Rajco/ Mandev/ Maxflow34.9 mm with 1.21 mm thick
30919.1 mm with 0.8 mm thick
31015.9 mm with 1.00 mm thick
311Providing & fixing control cum transmission wiring of 2 core x 1.0 sqmm shielded copper cable in suitable conduits between indoor and out door unit. Make-Polycab/KEI/Finolex/RR Kabel/Gloster/Havells/V-Guard
312Providing & fixing of PVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness Class O of closed cell nitrile rubber/XLPE as per direction of Engineer-in-charge & specifications enclosed as reqd. 40 MM dia
31332 mm dia
314Supplying,fixing of hot dip galvanized GI unperforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 600mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
315Supplying,fixing of hot dip galvanized GI unperforated cable trays with cover having horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 450mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
316Supplying & laying of one number PVC insulated armoured and PVC sheathed XLPE property copper. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 5core x 10 sq mm
317DG SETS AND OTHER ACCESSORIES 250 KVA DG Set Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 250KVA ( Make -Kirloskar / Jakson/Mahindra) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21. ENGINE: Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 250KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 12 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading.02. Diesel tank suitable for 8 to 10 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standardsAMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 250KVA DG Set complete with Battery Charger & leads as required. BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channel and vibration damping arrangement with cushy foor mounting including paintng etc. as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. *It also includes control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work)
318Miscellaneous Items Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter \\"FIRE\\" in black and gold. Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets.
319Supply installation of high-voltage insulating mat has a thickness of 3.0 mm, rated for maximum use voltage of 33 kV. It withstands an AC proof voltage of 36 kV and an AC dielectric strength of 65 kV, with maximum leakage current limited to 10 mA. Minimum insulation resistance (5000V megger) is 1,00,000 MΩ. Tensile strength is minimum 15 N/mm², with 250% minimum elongation. After 168 hrs aging at 70±1°C, retention is minimum 75% (tensile & elongation); after 48 hrs immersion in acid/alkali/diesel/oil, retention is minimum 80%. The mat offers low-temperature resistance and flame retardance, made of synthetic elastomer, conforming to IS 15652. complete as per direction of Eng-in-charge.(Size-10mx1m) make : mandelia insulation and transmission co./Duratuf/Raychem/Vardhman
320LAN SYSTEM-SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
321SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
322SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
323SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
324SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit 1mtr Length
3252mtr Length
326SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP, Netgear
327SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
328SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand
329SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
330SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
331SITC of 1G-LX/LH SFP transceiver module,. Make: Cisco, Digisol, Netgear
332SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
333IP-CCTV SYSTEM-SITC of 5MP IP Bullet/Dome Camera with inbuilt microphone, equipped with 1/2.7\\" Progressive Scan CMOS image sensor and 3.6/2.8(for dome) mm fixed lens, supporting a resolution of 2592 × 1944 or higher. The camera shall provide IR illumination up to 30 meters and an approximate field of view of 79° (H)/97(for dome), 56°/70(for dome) (V), and 106°/128( for dome) (Diagonal). Minimum illumination shall be 0.003 lux @ F1.6 (AGC ON) with support for WDR (120 dB). The camera shall support video compression formats such as H.265+, H.265, H.264+, H.264 and MJPEG, with multiple streaming capability including main stream up to 5MP @ 30 fps, sub-stream up to 1080p @ 30 fps, and additional third stream. The camera shall support intelligent analytics such as human and vehicle detection, perimeter intrusion detection, line crossing detection, object detection, heat map, crowd density detection, queue length detection, and rare sound detection. The device shall support motion detection with multiple configurable zones and network protocols including TCP/IP, HTTP, DHCP, RTP/RTSP, SMTP, NTP, UPnP, SNMP, HTTPS and SFTP, and shall be ONVIF compliant (Profile S/G/T). The camera shall include micro SD card slot up to 256 GB/512 GB( for dome), privacy masking, ICR auto day/night switching, and support 12V DC or PoE power supply. The housing shall be metal body with IP67 weatherproof protection, suitable for outdoor installation. The product shall comply with NDAA requirements and shall be certified with STQC, BIS, CE, FCC and RoHS. Make-Honeywell Value series/Pelco/Axis/Bosch
334SITC of 64CH project series Network Video Recorder, Should support Resolution:- greater than equal to 12 MP IP Camera, Network Bandwidth incoming 640 Mbps and outgoing 640 Mbps for access, support for H.265+/H.265/H.264 encoding format streaming access and decoding output, Recording play back quality: 16 ch play back simultaneously, Recording resolution up to 12MP, Recording mode: support manual, Auto, Motion detection, Alarm, trigger record mode, Operation way: Mouse, local Login: Username and password, Recording storage: Local HDD, network, Video output: HDMI/VGA/TV, Support min. 8 SATA HDDs , Each port supports min. 18TB HDD(Enterprise class),support-RAID0, RAID1, RAID5, RAID6, RAID10,Support dual Gigabit Ethernet ports,Supports 4 HDMI outputs,Alarm Input/out:16 in /4 out ,Audio:1 in / 1 out ,Supports intelligent analytics such as Licence plate detection,Face Recognition,Human&Vehicle Detection,Perimeter Intrusion Detection,Line Crossing Detection, Cross Counting,Stationary Object Detection,Heat Map,Crowd Density Detection,Queue Length Detection, Rare Sound Detection, product must comply with NDAA complaince, Certification: BIS,CE,FCC,ROHS. Make-Honeywell value series /Pelco/Axis/Bosch
335Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba
336SITC of 55\\" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/ Samsung/ Sony
337SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer
338LIFT-Supply,Installation, Testing & Commissioning of of 16 Passenger-cum-bed lift gearless with Machine room Capacity(1088 Kg), with minimum shaft size of 3000mm(Front to back)x2000mm( left to right), car size of 1200mm(left to right), 2400(Front to back) Elevator G+7 Floors with ACVVVF drive/Control with ARD >=1.25 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc .All SS material shall be of grade SS-304 and minimum thickness of 1.2mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons(v) provision of flat cat 6 cable for CCTV with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respec as per the instruction of Engg. in charge.The Elevator should be suitable for physically handicapped person. make:OTIS/Mitsubishi/Schindler/Johnson
339Supply,Installation, Testing & Commissioning of of 10 Passengerlift gearless with Machine room Capacity(680 Kg), with minimum shaft size of 2000mm(Left to right)x2000mm(Front to back) Elevator G+7 Floors with ACVVVF drive/Control with ARD >=1.25 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc .All SS material shall be of grade SS-304 and minimum thickness of 1.2mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons(v) provision of flat cat 6 cable for CCTV with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respec as per the instruction of Engg. in charge.The Elevator should be suitable for physically handicapped person. make:OTIS/Mitsubishi/Schindler/Johnson
340FIRE FIGHTING SYSTEM-PUMPS AND APPURTENANCES- FIRE PUMPS & RELATED ACCESSORIES :- Supplying & installing completely testing & commissioning of End Suction Back Pull Out pump set having pump speed of 2900 rpm, Pump Efficiency not less than 65%, with CI Casing, Bronze Impeller, SS 410 Shaft & Shaft Sleeve Connected through Flexible Coupling with a TEFC Sq. Cage Induction Motor mounted on a common base frame fabricated in MS Channel. Packing has to be of Mechanical seal. It has to be inclussive of all the pump accessories. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. Motor to be of continuous rating Motor to be suitable for 415V, 50Hz, AC supply of 45 KW rating for the above pumps. Motor shall accept +/- 10% variation in voltage and +/- 3% variation in frequency. It has to be of IE2 efficiency class. etc. complete.Make-Kirloskar/WILO/KSB.Pump - Motor : Discharge : 2280 LPM, Head-88mtr. Please Enable Macros to View BoQ information
341FIRE FIGHTING SYSTEM-PUMPS AND APPURTENANCES- FIRE PUMPS & RELATED ACCESSORIES :- Supplying & installing completely testing & commissioning of End Suction Back Pull Out pump set having pump speed of 2900 rpm, Pump Efficiency not less than 65%, with CI Casing, Bronze Impeller, SS 410 Shaft & Shaft Sleeve Connected through Flexible Coupling with a TEFC Sq. Cage Induction Motor mounted on a common base frame fabricated in MS Channel. Packing has to be of Mechanical seal. It has to be inclussive of all the pump accessories. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. Motor to be of continuous rating Motor to be suitable for 415V, 50Hz, AC supply of 45 KW rating for the above pumps. Motor shall accept +/- 10% variation in voltage and +/- 3% variation in frequency. It has to be of IE2 efficiency class. etc. complete.Make-Kirloskar/WILO/KSB.Pump - Motor : Discharge : 2280 LPM, Head-88mtr. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57385891
AUTHORITY Government Departments
TENDER VALUE 13.67 Crore
LAST DATE 22-09-2026
Authority
Authority Name Civil Division
Work Description Tender for Construction Of (S+7) Storied Building Near Mhi For Infrastructure Of Centre Of Competence, Scb Medical College And Hospital, Cuttack.
Basic Detail
Tender No CE-Bldg-I-28/2026-27
Bidding Type Tender
Location
City Cuttack
State Odisha
Key Dates
Publish Date 07 Sep 2026
Submission Date 22 Sep 2026
Open Date 23 Sep 2026
Finance
Tender Value 13.67 Crore
Tender Fee 10000
EMD 13.68 Lakhs
Exemption Available
Document List
BOQ_608568.xls
d706e991-b53b-4928-a5e3-cad0cd41272b.html
Tendernotice_1 (19).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_608568.xls

html

d706e991-b53b-4928-a5e3-cad0cd41272b.html

pdf

Tendernotice_1 (19).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders