Road Transport and Highways Government Departments Closing in 20 days TDR #57385816

Tender For Construction Of Swimmimg Pool (Sp) At Indian Academy Of Highway Engineers, Sector-62, Noida

Issued by Government Departments · Gautam Buddha Nagar, Uttar Pradesh
Tender Value
1.76 Crore
Estimated cost
Bid Submission
29 Sep 2026
20 days left
EMD
3.50 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gautam Buddha Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Swimmimg Pool (Sp) At Indian Academy Of Highway Engineers, Sector-62, Noida

BOQ

Name of Work:- Construction of Swimmimg Pool (SP) at Indian Academy of Highway Engineers, Sector-62, Noida
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
2Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
4Carriage of Earth by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KM complete.
5Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
6Extra rates for quantities of works, executed : In or under water and/or liquid mud, including pumping out water as required.
7Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
8Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
10Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns
11Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
12Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
13Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
14Extra for laying concrete in or under water and/or liquid mud including cum per cost of pumping or bailing out water and removing slush etc.complete.
15Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
16Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.
17Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
18Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform.
19Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ)
20Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
21Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts.
22Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
23Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like. Edges of slabs and breaks in floors and walls under 20 cm wide
24Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like. Edges of slabs and breaks in floors and walls under 20 cm wide Weather shade, Chajjas, corbels etc., including edges.
25Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
26Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
27Extra for laying reinforced cement concrete in or under foul positions.
28Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
29Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum
30Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
31Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum
32Add for using extra cement in the items of design mix over and above the specified cement content therein.
33Providing, laying and position 20 micron Polythene sheet of over the 10mm fine sand base as a separation membrane as per design & drawing etc. all complete.
34Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
35Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
36Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
37Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
38Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm
39Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin baesd adhesive including cleaning etc. complete.
40Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble /Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete.
41Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
42Providing and fixing Aluminium Sliding door bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nut & screws etc. complete. 300x16 mm
43Providing and fixing Aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 250x10 mm
44Providing and fixing Aluminium tower bolts ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 150x10mm
45Providing and fixing ISI marked Aluminium handles ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 125mm long
46Providing and fixing ISI marked Aluminium handles ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete. 100mm long
47Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper
48Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete.
49Providing & fixing bright finished brass 100 mm mortice lock with six levers without pair of handles of approved quality for aluminium door, with necessary screws etc. complete. As per direction of Engineer-in charge.
50Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge.
51Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing. 30 mm thick pre laminated PVC door shutters
52Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds. Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 meter)
53Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds. Fixed window / ventilator with mullion / transom. Using R1 series with frame (33mm & above ) x (35mm & above) & mullion (33mm & above) x (50mm & above). (Height upto 0.90 meter)
54Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds. Ventilator Casement window single panel with or without fixed panel with S S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handles. Using R1 series with frame (33mm & above ) x (35mm & above) & sash /mullion (33mm & above) x (50 mm & above). (Height upto 0.90 meter).
55Providing and fixing steel roller for uPVC / aluminium sliding window with necessary screws etc. complete.
56Providing and fixing steel (white power coated) crescent lock for uPVC / aluminium sliding window/ door with necessary screws etc. complete.
57Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
58Providing and fixing bolts including nuts and washers complete
59Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
60Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete.
61Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 80 mm
62Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
63Providing and fixing PVC Drain grating 500mm wide of approved quality with necessary accessories and screws etc. as per direction of Engineer-in-charge.
64Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
65Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.
66Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
67Extra for pre finished nosing to treads of steps of marble / granite stone.
68Extra for marble / granite stone flooring in treads of steps and risers using single length up to 2.00 metre.
69Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
70Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
71Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
72Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
73Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
74Providing and fixing Glass mossaic tiles on finished plain wall & floor surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customized design as per direction of Engineer in charge. The glass mosaic tiles shall be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operations, material and required pattern approved by Engineer-in-charge.
75Providing and laying specially moulded overflow channel grating ( rigid grating of f size 250mm X 25mm required length of approved shade and manufacturer for overflow channel of swimming pool / diving pool fixed in position complete as per direction of Engineer-in-Charge complete.
76Providing and fixing outdoor pool deck flooring with UV-stabilized, weather-resistant PVC decking planks, minimum 25 mm thick × 140–150 mm wide, having embossed/wood-grain anti-slip textured surface, suitable for continuous outdoor/wet pool-deck application and resistant to moisture, UV radiation, chlorine and fungal/termite attack, including supply and fixing of corrosion-resistant GI/Aluminium support joists/battens at maximum 300–350 mm c/c, levelling and alignment, SS-304 concealed clips, screws and fasteners, starter/end clips, matching PVC edge fascia/nosing, cutting, drilling, wastage, necessary expansion gaps, surface preparation, complete installation and all incidental materials, labour, tools & tackles, all complete as per manufacturer's recommendations and Engineer-in-Charge's approval.
77Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
78Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
79Providing and fixing on wall face unplasticised Rigid PVC rainwater pipes confirming to IS:13592 Type A including jointing with seal ring confirming to IS:5382 leaving 10 mm gap for thermal expansion.(I)single socketed pipes. 110 mm diameter
80Providing and fixing on wall face unplasticised PVC moulded fitting acessories for unplasticised Rigid PVC rain water pipes confirming to IS-13592 type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion. Coupler 110 mm
81Providing and fixing on wall face unplasticised PVC moulded fitting acessories for unplasticised Rigid PVC rain water pipes confirming to IS-13592 type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion. Bend 87.5* 110 mm bend
82Providing and fixing on wall face unplasticised PVC moulded fitting acessories for unplasticised Rigid PVC rain water pipes confirming to IS-13592 type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion. Shoes (plain) 110 mm shoe
83Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse and) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
84Polycarbonate Sheeting Supply & Installation of roof with co-extruded, UV protected, multi-layered / multi-cell connectible modular polycarbonate panel system. The system is consisting of 22 mm thick standing seam panel with X-cell truss bracing design structure for better strength and flexibility in seven layers with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be fixed on Purlins of MS / aluminum structure (to be paid Separately) with wide trapezoidal SS fastener/cleat/Aluminium Special Profile with top holding of 80mm on standing seam, fixed with purlins with 3 numbers of self-drilling screws to ensure a pull-out load of min. 7000 N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005. The entire fixing mechanism shall be covered with a continuous U/2, interlocking connectible connectors with grip lock anti pop double tooth locking mechanism running lengthwise at both sides of the panel. Each panel shall be flux solo opaque type with opaque and clear combination of louvers inside the single panel i.e. with transparent body and opaque layers in between the layers creating 'Light Duct' for better ambience & increased shading. Panels with more layers will be preferred for better insulation and improved shading coefficient. U value of such panel shall not be more than 1.7 Watt/m2K as per EN ISO 10077-2:2018 and respective third-Party test certificate shall be produced before procurement. The width of the panels shall not be less than 1220 mm. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D2244 (standard D65 illuminant, CIELAB) not more than 1 unit when tested on a sample exposed to UV/weathering test for 2500 Hours as per ASTM D4329. The panel shall be with additional sealing / breathing tape, Aluminum U profile for ends, screws etc. as per standard accessories as required. Panel shall be fixed conforming to the detailed methodology & guideline as per the manufacturer. Trained and factory authorized labor shall be used with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge. Color: As per approval.
8512 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
8615 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
8720 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
88Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
896 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
90Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
91Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
92Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
93Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.
94Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm.
95Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats.
96Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
97Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
98Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
99Providing and fixing Glass Reinforced Concrete (G.R.C) Screen at all levels & heights in approved size, pattern, design, thickness and color. The Screens should be made from ‘53 grade’White Portland Cement, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber, Super Plasticizers, Polymers and U.V resistant Synthetic inorganic pigments should be used for pigmentation. The material casting should take place in Synthetic Rubber / FRP Mould. The fixing of Jali should be ‘Dry fixing’ i.e. to be done with MS/SS ‘L’ shaped Clamps, dash fasteners and pins etc as per site requirment.
100Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed echanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Glazing and paneling to be paid for separately) : For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron)
101Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed echanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
102Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides
103Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With clear toughened glass panes of 6 mm thickness
104Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With clear toughened glass panes of 8 mm thickness
105Providing and fixing in position 12 mm thk Toughened Clear Glass in partition panels by using various glass fittings of approved make (DORMA / HAFELE / HETTICH) to be fixed with necessary fittings on the ceiling duly finished without giving any load on the false ceiling by using necessary hardware of Dorma / Hafele make what ever necessary and required numbers to complete the job in all respect. Rate including cost of door opening with approval hardware such as patch fitting lock, handle etc of approved make but without cost of floor spring. Contractor is advised to submit working drawing with details of approved make patch fitting, sizes of glass panels etc and take approvals of consultants before execution of works. All complete as per detail drawing, as specified and as directed by Architect / Consultant / Project - In - Charge.
106Filling the gap in between aluminium frame and adjacent RCC/Brickwork/ Stone Work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge Upto 5mm depth and 5mm width
107Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
108Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in- Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
109Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
110Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
111Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick)
112Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm
113Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.
114Providing and fixing switches piano, flush type single pole, one way 15/16 Amps 230 volt AC supply, ISI marked complete all as specified and directed.
115Providing and fixing socket outlet two in one 5 pin 5/6 Amps flush type, 230 volt AC supply complete all as specified and directed.
116Surface rond ceiling light (white) 1 x 12 watts LeD, energy efficient light, complete with all accessories. PHILIPS Part No. 915006388101)
117Surface rond ceiling light (white) 1 x 15 watts LeD, energy efficient light, complete with all accessories. (PHILIPS Part No. 915006387601).
118Surface rond ceiling light (white) 1 x 7 watts cob LeD, energy efficient light, complete with all accessories. PHILIPS Part No. 9290037694_1)
119Surface rond wall light (white) 1 x 7 watts LeD outdoor ip65 waterproof light, energy efficient light, complete with all accessories. PHILIPS Part No. 915006349512)
120Surface rond ceiling light (white) 1 x 10 watts LeD, energy efficient light, complete with all accessories. PHILIPS Part No. 915006387701)
1211 x 11 W CFL SU , 11 W , mirror night compact and & decorative luminaire with anti glare diffuser & decorative end caps Make:Cat no- LHFOECF1OZ1W011 or equivalent model of Havells or Anchor or bajaj
122FANS 1200mm dia sweep ceiling fan with standard down rod, of Crompton, Usha, Bajaj make.
123Providing and fixing Stepped type Modular Fan regulator (2 module)
124300mm dia heavy duty 900 RPM exhaust fan complete with louvered shutters
125Providing and fixing in position storage type vertical electrical water heater with copper container, · Moulded PUF insulation for less energy consumption , and stove enameled M.S. Jocket, thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia inlet with non-return valve and 15/20mm dia outlet including making connections complete in all respects (wall mounted with suitable M.S bolts and nuts) AO Smith / Racold /Jaquar make. a) Capacity 25 liter
126Copper point wiring in steel conduit : Material & Labour for point wiring complete with 1.5 sqmm multi stranded copper conductor single core PVC insulated unsheathed FRLS cable 1100 grade (ISImarked) with proper colour coding drawn through and non metalic rigid PVC medium grade conduit not less than 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundry terminal box made out of GI sheet steel not less than 1.22mm thic for boxes upto a size of 200 x 300 mm and above this size not less than 1.63 mm thick duly painted with aluminnium inside and anti-corrosive paint out side, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles. Where concealing of conduit is not feasible i.e. on surface of roof etc. conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for the following :- a) One Light/Fan/Exhaust Fan/wall mounted fan point controlled by one way switch 5/6 Amps, 230 V.
127b) One 3 pin socket outlet, 5/6 Amps point on the same board with other switches.
128c) One 3 pin 5 amps socket outlet point on independent board.
129Point wiring in steel conduit, all as per the preceding light / fan point wiring item but wiring with 2.5 sq.mm multistranded cable and earth wire with copper conductor of size 2.5 sq.mm for one 5 pin socket outlet 16 Amps on independent board for power plug/geyser point/AC point.
130Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required : 150mm x 150mm x 60mm deep
131180mm x 100mm x 60mm deep
132200mm x 125mm x 60mm deep
133200mm x 150mm x 75mm deep
134S/F light plug point accessories (NR): Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,connection etc. as required. (For light plugs to be used in non residential buildings).
135S/F light plug point accessories (NR): Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
136Providing and fixing switches Piano, flush type single pole, one way 5/6 Amps, 230 Volt, AC supply, ISI marked complete all as specified and directed.
137Providing and fixing switches piano, flush type single pole, one way 15/16 Amps 230 volt AC supply, ISI marked complete all as specified and directed.
138S/F ceiling rose: Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
139S/F 5A to 32A L Series MCB: Supplying and fixing 6 amps to 32 amps rating, 240 volts,miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (Category-B): 6 amps. to 32 amps. ratings , SP MCB, \\"C\\" curve, 10 KA breaking capacity
140S/F SP MCB blanking plate: Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required.
141S/F FP MCB isolator : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required: 63 Amps
142S/F SPN MCB DB : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 2 + 6 way/ 8 way , Double door
143S/F TPN MCB DB : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar,earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
144P/F MV danger notice plated : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm,made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
145P/F copper lightning conductor finial Providing and fixing of lightning conductor finial, made of 25mm, dia, 300mm, long, copper tube, having single progn at top, with 85mm. Dia. 3mm. Thick copper base plate including holes etc. complete as required.
146Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/sweating and soldering etc as required.
147P/F GI lightning conductor tape in horizontal run Providing and fixing GI tape 20mm x 3 mm thick on parapet or surface of wall for lightening conductor as required (for horizontal run)
148P/F GI lightning conductor tape in vertical run Providing and fixing GI tape 20mm x 3 mm thick on parapet or surface of wall for lightening conductor as required (for vertical run)
149P/F testing joint for GI lightning conductor strip Providing and fixing testing joint, made of 20mm x 3mm. Thick, GI strip, 125 mm. Long, with 4 nos. of tinned brass bolts, nuts, check nuts and spring washers etc. complete as required
150P/L GI earth tape for lightning conductor Providing and laying GI tape, 32mm x 6 mm thick from each electrode directly in ground as required.
151PRESSURE SAND FILTER (HT - 48)/1200dia Supply, installation, testing & commissioning off FRP 1200dia Pressure sand filter with Flow rate 49000 LTR/hr capacity, Connection size 2 “ Features -The fiberglass winding design enables the filter to be durable, deforming-proofand corrosion resistant -A Unique and advanced design ensure fast draining and stabilizes water flow. -The sand filter comes with a precise gauge -It is easy to install and to maintain -The outlet turbidity is than 2ftu. -Working pressure is 2.5 kg cm2/36 psi. -Uv resistance surface allows the filter to work under direct sunlight as directed by Engineer-in-charge including all Labour & Materials etc complete.
152FILTER MEDIA (SILICA SAND) Supply & Commissioning of Filter Media with it’s complete multiple layers (50kg/bag)
153Supply, Testing & Commissioning of Installation Swimming Pool MOTOR Pump Supply of recirculation self priming pump set 3 hp, single phase connection size 63 mm Model HPC-300, 3 HP PUMP 2.2 KW Flow rate : 36000 ltr/hr Duty - 1 nos and Stand by - 1 no. as directed by Engineer-in-charge including all Labour & Materials etc complete.
154Supply, installation, testing & commissioning of, EYE BALL INLET Colour: White Flow Rate: 9M³/hr - 12M³/hr Floor inlets made in white ABS, UV resisted, Adjustable 63mm Solvent Type Easy to control Flow as directed by Engineer-in-charge including all Labour & Materials etc complete.
155Supply, installation, testing & commissioning of, VACCUME POINT Colour: White Flow Rate: 9M³/hr - 12M³/hr Floor inlets made in white ABS, UV resisted, Adjustable 63mm Solvent Type Easy to control Flow as directed by Engineer-in-charge including all Labour & Materials etc complete.
156Supply, installation, testing & commissioning of, Led Underwater Light (ABS) Diameter-178mm Material- ABS IP-68, High Quality Electrical Cable 1m Volts/Walts: 12V/12W Led Color:Warm/Cool White as directed by Engineer-in-charge including all Labour & Materials etc complete.
157Supply, installation, testing & commissioning of electrical works in pool basin & filteration plant room with allied piles, fittings, cables,wiring ,conduits pipe,elbow & connection box etc as per site requirement , as directed by Engineer-in-charge including all Labour & Materials etc complete
158CENTRALISED PUMP ELECTRIC CONTROL PANEL Supply of Electrical control panel Phase connection complete To control pump all elecrtical equipmentscomplete with CRC sheet Powder caoted fabricated box with Volt meter 1 No, Ampear meter, DOL Starter , indication phase light for each pump and facing, on – off Swich and 32 Ao/ /64 As per required MCB , ELCB complete internal box wiring 2.5 Sqmm/4 mm Make Fabricated etc. complete.
159Supply & Fixing of Grating 11\\" - 1 pin 25mm : white Manufactured in Polypropylene + co -polymer wirh UV Protected. 11\\" 1 Pin 25mm. Colour Available : White, Blue, black & all as per customer's demand (Charges Extra) , as directed by Engineer-in-charge including all Labour & Materials etc complete
160Supply & Fixing of SWIMMING POOL LADDER Swimming pool ladder 3 steps SS 304 with SS Steps , as directed by Engineer-in-charge including all Labour & Materials etc complete
161Supply & Fixing of SWIMMING POOL LADDER Swimming pool ladder 4 steps SS 304 with SS Steps , as directed by Engineer-in-charge including all Labour & Materials etc complete
162Supply & Fixing of ABS Square Main Drain Color: WhiteFlow Rate: 850L / MinSquire Main Drian 300mm X 300mm , Material-ABS , as directed by Engineer-in-charge including all Labour & Materials etc complete
163Supply & Fixing of Flexible Vacuum Hose pipe 15 mtr 40mm / ( PREMIUM GRADE) Vaccum Hose 1.5\\"*50\\" , as directed by Engineer-in-charge including all Labour & Materials etc complete
164Supply & Fixing of Telescopic Pole 4.8 mtr /Ribbed Pole 4 .8 Mtr , as directed by Engineer-in-charge including all Labour & Materials etc complete
165Supply and Trial Test of VACCUME HEAD VACC 18\\" head/Vacc HEAD 18\\" - AVH02BX MATERIAL : ALUMINIUM , as directed by Engineer-in-charge including all Labour & Materials etc complete
166Supply and Trial Test of Wall Brush 18\\" Wall Brush Nylon/ Standard Curved Poly Bristle Wall Brush , as directed by Engineer-in-charge including all Labour & Materials etc complete
167Supply and Trial Test of Leaf Net Deep Leaf Net Deep Deluxe/ Heavy Duty Deep Rake W/alu.- 6608 Bu/ Ls 160b/ls10b , as directed by Engineer-in-charge including all Labour & Materials etc complete
168Supply and Trial Test of STAINLESS STEEL ALGAE BRUSH HI GRADE STAINLESS STEEL ALGAE BRUSH 10\\"/ Algae brush 10” , as directed by Engineer-in-charge including all Labour & Materials etc complete
169Supply, installation, testing & commissioning of 6 WAY TOP MOUNT MPV FILTER:- Normal Filtration and Vacuuming.BACKWASH:- Cleaning Filter by reversing the flow.RINSE:- Use after backwash to flush dirt from valve.WASTE:- By - passes filter , used for vacuuming to waste or lowering water level.RECIRCULATE:- By - passes filter for circulating water to pool.CLOSED:- Shuts off all flow filter or pool. as directed by Engineer-in-charge including all Labour & Materials etc complete
170Supply & Fixing of SS Hand Rail 1 Mtr Long ,Grade SS 304 , as directed by Engineer-in-charge including all Labour & Materials etc complete
171Supply, installation, testing & commissioning of all pipes and fitings,TEE,MVP,MTA,ELBOW,Valve Ball etc. as directed by Engineer-in-charge including all Labour & Materials etc complete
172Installation of Above Metrial as directed by Engineer-in-charge including all Labour & Materials etc complete
173Providing and fixing vitreous wall hung china water closet (European type W.C.pan) complete with proprietry seat and cover (soft close), pan connector, suitable mounting brackets/chair including cutting and making good the walls and floors wherever required, of the following make and type:(or equal approved) a) Make : Hindware Model: : Armada Cat. No. : 92036 with soft seat cover Colour : White
174Providing, fixing and commissioning wall Concealed WC Flushing Cistern with Flushing Actuator Plate ( of approved finish), cutting and making good the walls including making connection with WC Pan, all Manufacturer`s specifications, of the following make and type:(or equal approved). Make : Hindware Model: : Concealo
175Providing and fixing vitreous china wash basin with special C.I brackets, including C.P. brass waste of standard pattern, 32 mm C.P brass bottle trap, complete including cutting and making good the walls and floors, wherever required of the following make and type: (or equal approved) a) Make : Hindware Model. : ZEN Cat.No. : 10049 Colour : White
176b) Wall Hung Wash Basin for Handicapped Toilet Providing and fixing of ABS Chrome platted overhead shower with wall flange, of the following make and type: (or equal approved) Make : JAQUAR Cat. No. : Shower Headl: OHS 1989) and Shower Arm ( Model: SHA 477) Colour/Finish : Chrome
177Providing and fixing of C.P brass concealed shower mixer for overhead shower all complete with internal body,of approved make. (or equal approved) Make : JAQUAR Model : Florentine Cat. No. : FLR 5139 ( with flow restrictor upto 5.5 LPM) Finish : Chrome
178Providing, fixing, testing and commissioning infra-red sensor controlled electrically operated (220V, AC mains) and battery operated mixer with suitable extension peice for wash basin comprising light sensing device and solenoid valve of approved make including hot and cold water mixer unit, interconnecting control cabling between sensor & solenoid valve including cutting and making good the walls and floors as required, all complete b) Make : Euronics Cat. No. : ET05 Finish : Chrome
179Providing and fixing of 15 mm dia brass angle valve (inlet fitting ball valve type) having strainer screen complete with wall flange of following make and model:(or equal approved) Make : Kohler Model no. : K-11568IN-7-CP
180Providing and fixing of stainless steel braided flexible hoses with inliner EPDM Which can bear the maximum pressure of 10 bar and maximum temperature of 90 degree Celsius with bending radius of 25R with length 500 mm with Union nut connection of 1/2\\"
181Providing, fixing and commissioning hand drier with infra red controlled automatic on/off arrangement ( No Touch) including cutting and making good the walls complete with all necessary fittings to make it operational as required,of the following make and type:(or equal approved) Make : Euronics Model. No.: EH 22
182Providing and fixing stainless steel finish toilet paper holder including cutting and making good the walls complete of following make and type: (or equal approved) Make : Euronics Model No. : EPH (04F) Finish : Chrome Finish
183Providing and fixing stainless steel finish towel dispensor including cutting and making good the walls complete of following make and type: (or equal approved) Make : Euronics Cat. No. : EP01 Finish : Chrome Finish
184Providing and fixing liquid soap dispenser including cutting and making good the walls complete of following make and type: (or equal approved) Make : Euronics Cat. No. : ES 09 Finish : Chrome Finish
185Providing and fixing wall mounted auto aerosol dispenser with digital display fixed with brackets and rowl plug complete in all respects Make : Euronics Cat. No. : EA03
186Providing and fixing stainless steel coat hooks including cutting and making good the walls complete of following make and type: (or equal approved) Make : Euronics Cat. No. : EC02
187Providing and fixing hand held ablution fitting (health faucet) with one metre long flexible tube and wall hook, all complete of following make.(or equal approved) Make : Kohler Cat. No. : K-98100IN-0 Finish : Chrome
188Providing and fixing electric water storage heater (geyser) of following capacities including making inlet / outlet connections, of approved makes. Make: AO Smith a) Capacity : 25 litre
189Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1 . 8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
190Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
191Providing, jointing and fixing UPVC Soil, Waste and Vent System The work shall be done as per technical specifications and in general shall include: Material: UPVC pipes and fittings (moulded as well as fabricated) conforming to IS : 13592 - Type B Fittings shall include all standard moulded as well as fabricated fittings like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offsets and other specials Jointing: Pushfit rubber ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints Installation, Testing and Commissioning: The installation shall be complete in all respects including cutting chases / holes in walls, slabs, excavation, refilling and disposal of surplus earth where required and making good, etc M.S Supports: All vertical and suspended horizontal pipework shall be fixed on MS brackets and hangers with U-clamps made from 10 mm dia galvanised steel rod complete with nuts and washers. Cost for MS structural work for supports shall be included in the rates Conctere Encasing ( In case of Sunken Floor/ burried pipes): The pipes and fittings shall be encased with 75 mm thick cement concrete ( 1:2:4) all around Making Good the Structure Crossongs: For all horozontal and vertical crossings of building structure ( slabs, walls, beams, coloumn etc), the space between pipe and the structure shall be made good and water tight with concrete. The annular space between the pipe and the sleeves shall be sealed (upto a minimum depth 25 mm) with fire resistant acrylic based sealent of approved make and quality. a) 110 mm dia
192Providing & fixing UPVC soil, waste, vent pipework comprising UPVC pipe conforming to IS :4985-1983 and of required class as specified below and fittings (moulded as well as fabricated) like elbows, bends, reducers, threaded tail pieces, caps and and other specials. jointing with cement solvent, chasing, cutting and making good the walls, complete in all respects including testing of complete installation. a) 40 mm dia pipe
193Providing and fixing of UPVC Floor Traps formed out of bore 'P' trap with 50 mm water seal, setting in 1:2:4 mix cement concrete block or clamping to the wall or suspending with the ceiling including cutting and making good the walls and floors wherever required. a) 110 mm inlet and 110 mm outlet
194Providing and fixing PVC floor trap EXTENTION PIECE formed out of 110 mm pipe with multiple side inlets formed with saddle pieces, suitable for 40, 50 and 63 mm dia side connections as per standard detail.
195Providing and fixing 110 mm dia round chrome plated bronze grating with frame, rotate lock type embedded in floor, all complete.
196P/Fixing straight /offset type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector (if required).
197Providing and fixing in position CPVC pipes conforming to IS: 15778:2007 (Grade SDR-11) with all fittings, brass threaded adaptors and specials, solvent cement/threaded jointing, effecting proper connections, cutting chases in walls and floors and making good (including making connection with existing pipework), Note: Pipe work in shafts, ceiling voids and terrace shall be supported/ fixed on MS structural supports with U-clamps complete with nuts and washers.Cost for MS structural work for supports shall be included in the rates all complete. ( Pipework inside the toilets and pantry etc) Note : 1) Solvent Cement shall be of make and grade as specified by the manufacturer of CPVC piping system. 2) The entire CPVC piping system shall be installed, tested and commissioned following the recommendation of the manufacturer. b) 3/4\\" N.D.(SDR 11 Rated )
198Providing and fixing of nickel plated brass/ nonferrous alloy fullyway ball valve ( minimum working pressure of 20 bar ) with operating handle of approved make.( Note: Existing isolating valve shall be used for making connection with new pipework) a) 20 mm dia
199Providing and fixing insulation to hot water piping with closed cell chemically cross-linked polyethylene ( XLPE) preformed pipe sleeves of specified wall thickness using propriety adhesive and self adhesive tapes, all as per the manufacturer's specifications. (For exposed water pipes in plumbing shaft and on terrace) a) 15 mm dia - 9 mm thickness Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57385816
AUTHORITY Government Departments
TENDER VALUE 1.76 Crore
LAST DATE 29-09-2026
Authority
Authority Name Ministry Of Road Transport And Highways
Work Description Tender for Construction Of Swimmimg Pool (Sp) At Indian Academy Of Highway Engineers, Sector-62, Noida
Basic Detail
Tender No IAHE/Admin./26/swiml/2026-27
Bidding Type Tender
Location
City Gautam Buddha Nagar
State Uttar Pradesh
Key Dates
Publish Date 07 Sep 2026
Submission Date 29 Sep 2026
Open Date 30 Sep 2026
Finance
Tender Value 1.76 Crore
Tender Fee Ref. Documents
EMD 3.50 Lakhs
Exemption Available
Document List
31e3b31a-4e20-4495-9acd-74f1c99d52c6.html
BOQ_972210.xls
Tendernotice_1 (10).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Sep 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

31e3b31a-4e20-4495-9acd-74f1c99d52c6.html

xls

BOQ_972210.xls

pdf

Tendernotice_1 (10).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders