Tender For Repairing Work Of Iv Th Type Quarters No. 1,2,5 & 6
Tender Value
10.06 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
0 days left
EMD
20125
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bikaner → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing Work Of Iv Th Type Quarters No. 1,2,5 & 6
BOQ
| Sl. No. | Item Description |
| 1 | Labour charges for Removing S.W. pipes including breaking of joints & bed concrete, stacking of useful material at site within 50 mtr. Lead and disposal of unserviceable material within 0.5 Km. lead:200, 230 & 250mm dia pipe.As per Pwd BSR 2025,Ch.-S-3,Item no.-3.7.2 |
| 2 | Providing Laying & jointing glazed S.W. pipes grade `A` (IS;651 marked) of approved make with spun yarn & stiff mixture of cement mortar 1:1, excavation & refilling of earth in all types of soil upto 1.2m depth, S.W. fittings, including testing of joints etc, complete 200mm dia .As per Pwd BSR 2025,Ch.-S-3,Item no.-3.1.3 |
| 3 | Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) all around S.W. pipe including 15 Cm. thick bed concrete (Width W= Diameter of pipe in Cm+30 Cm.)( Excluding cost of pipe) 200mm dia S.W. pipe As per Pwd BSR 2025,Ch.-S-3,Item no.-3.2.3 |
| 4 | Providing and laying cement concreting including curing, compaction etc. complete using stone aggregate 20 mm nominal size in foundation and plinth, excluding cost of shuttering using.M-15 grade mix 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate).As per IGNP BSR 2026,Ch.-IX,Item no.-3.3 |
| 5 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement As per Pwd BSR 2025,Ch.-B-11,Item no.-11.17.2 |
| 6 | Providing and Applying ACRYLIC emulsion polymer waterproofing chemical coating, on over roof on over roof slabs/terrace/balconies/parapet wall etc.with following method/specification:Paint the surface with regular paint brush so as to obtain approximately 0.3mm thickness coating. apply the 2nd coat next day at right angles to the 1st coat so that total thickness of the coating should be approximately 0.6mm coverage by using above formulation will be 40 ft2/ litre of chemical. painted surface does not require any external water curing since chemical will hold sufficient water for curing.After the primer coat Apply 2 coats of modified acrylic emulsion polymer water proofing compound having solar heat reduction properties coating @ 0.330 KG/SQM on the surface of the interval of 3-4 hours. Undulation on the surface is repair before the waterproofing work.As per Pwd BSR 2025,Ch.-B-15,Item no.-15.29 |
| 7 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :As per Pwd BSR 2025,Ch.-B-10,Item no.-10.22 |
| 8 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. Short point (up to 3 mtr.) As per PWD BSR 2025 item no. 1.1.1 |
| 9 | Medium point (up to 6 mtr.) As per PWD BSR 2025 item no. 1.1.2 |
| 10 | Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. As per PWD BSR 2025 item no. 7.38 |
| 11 | Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. As per PWD BSR 2025 item no. 7.20 CH no.7 |
| 12 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. 2 x 4.0 sq.mm As per PWD BSR 2025 item no. -4.1.11 CH no.4 |
| 13 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. 25 mm.As per pwd electric bsr 2025 code no. 1.4.2 |
| 14 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. 2 x 2.5 sq.mm. As per pwd electric bsr 2025 code no. 4.1.6 |
| 15 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. 6 A to 32 A rating As Per PWD BSR 2025,Item No.6.1.1.2 |
| 16 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches by sandla/loi. (only for colour changing ). As Per PWD BSR 2025,Ch no.-B-12,Item No.12.35.7 |
| 17 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:Old work (one or more coats) including scrapping surface and necessary repairs Same colour As per pwd general bsr 2025 code no. 12.37.2.b, ch no.B-12 |
| 18 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:Old work (One or more coats). As per pwd general bsr 2025 code no. 12.41.2, ch no.B-12 |
| 19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm nominal outer dia pipes.as per pwd bsr 2022 ch no s-2 code 2.39.3 |
| 20 | P&F external grade board solid core single / Double leaf flush door shutter IS : 2202 ( part -2) 1996 marked using phenole formel dehyderesin in glue both side with approved stainless steel fitting complete as per annxure' A' : 30 mm thick commercial vaneer both side . As per PWD BSR 2025 item no. 8.13.2.1 page no. B-8 |
| 21 | Factory made 35 mm thick shutters with laminated veneer lumber styles rails as per TADS IS:1995 and panels of galvanised wire gauge with average width of aperture 1.4 mm on both directions with wire of dia 0.63 mm As per PWD BSR 2025 ch no.-1, item no. 7154 page no. B-40 |
| 22 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.As per PWD BSR 2025 ch no.-14, item no. 14.55 page no. 213 |
| 23 | Demolishing of Brick masonry including stacking of serviceable material and disposal of unserviceable material within 50 m lead.Brick masonry in cement mortar As per IGNP BSR 2026 ch no.-XV, item no.-2.2 |
| 24 | Brick masonary in foundation and plinth with brick designation 75 In cement sand mortar 1:5 + For using brick class designation 100 instead of class designation 75, Extra for brickwork in superstructure above plinth level for every 5m and part thereof As per IGNP BSR 2026,Ch no-10,Item No.-6.d+7.a+7.b |
| 25 | Cement plaster with cement sand mortar (1:5) including racking of joints, smooth finishing and curing etc.complete including all leads of all construction materials of thickness. 12 mm thick in 1 coats. As per IGNP BSR 2026,Ch no-11,Item No.-4.3 |
| 26 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:500 liter capacity .As per PWD BSR 2025 ch no.-S-2, item no. 2.26 |
| 27 | P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete :Brass wt.Not less than 600 gm, 25mm.As per PWD BSR 2025 ch no.-S-2, item no. 2.11.3 |
| 28 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).As per PWD BSR 2025 ch no.-B-7, item no. 7.13 |
| 29 | Providing and fixing 75 mm wide Decorative Border in different shades and in all coloures in glazed tiles laid over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete.As per PWD BSR 2025 ch no.-B-7, item no. 7.16 |
| 30 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.As per PWD BSR 2025 ch no.-B-12, item no. 12.23 |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:One or more coats on old work .As per PWD BSR 2025 ch no.-B-12, item no. 12.46.2 |
| 32 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).As per pwd general bsr 2025 code no. 7.13, ch no.B-7As per pwd general bsr 2025 code no. 7.12, ch no.B-7 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodaySep 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender