Tender For Replacement Of Fire Alarm And Detection System At Honble Cm House Cantt. Road Dehradun.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Sep 2026
20 days left
EMD
88900
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Fire Alarm And Detection System At Honble Cm House Cantt. Road Dehradun.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. 2 LOOP |
| 2 | Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 3 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 4 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 5 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 6 | Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. |
| 7 | Supplying, installation, testing & commissioning of addressable Manual Call Point complete as required. |
| 8 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 9 | Supplying & laying of 2Cx1.5 sqmm fire alarm armoured cable,600/1000V rated with annealed copper conductor havingXLPE insulation, steel wire armouring & FRLS outer sheathin existing trench/ conduit or in surface complete as required. |
| 10 | S/F of 25mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required |
| 12 | 100mm |
| 13 | 150mm |
| 14 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 15 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 16 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 17 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 18 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 19 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1 :3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | Supplying & laying of 2x1.5 sqmm unarmoured cable, voltage grade upto 1100V rated with Multicore annealed copper conductor having Pvc insulation in existing conduit or surface complete in all respect as required. |
| 22 | Supplying, installation, testing & commissioning of addressable gas (LPG, Natural Gas, coal gas) detector complete with base as required. |
| 23 | Constructing masonry Chamber 30x30x80 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for G.I./HDPE DWC pipe of different types of cable/wires , with water proof type suitable size C. I. black paint cover plate lid including necessary excavation, inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete complete in all respect as required. with hinged cover fixed in reinforced CC slab 1:1.5:3 mix (1cement :1.5 coarse :3 graded stone aggregate 20mm nominal size) |
| 24 | Constructing masonry Chamber 60x40x90 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for G.I./HDPE DWC pipe of different types of cable/wires , with water proof type suitable size C. I. black paint cover plate lid including necessary excavation, inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete complete in all respect as required and RCC top slab 1:1.5:3 mix (1cement :1.5 coarse :3 graded stone aggregate 20mm nominal size) |
| 25 | Dismentling of old/unusable fire alarm and detection system detector & devices complete in all respect as required. |
| 26 | Dismentling of old/unusable wire including pipe of fire alarm and detection system detector & devices complete in all respect as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender