| 1 | Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity. |
| 2 | 1.5 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 4500 Kcal/hr or 18000 BThu/hr or 5250 watt). |
| 3 | 2.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt). |
| 4 | Providing 3 star rated (Minimum 3 star with applicabls ISEER accordlng to current industry standard) Floor mounted vertical Split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) conforming to IS 1391(Part-II) specification (Except power consumption suitable for operation on 420 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity. |
| 5 | 3.65 TR floor mounted vertical Split type AC machine (Minimum rated cooling capacity should not be lsss than 10950 Kcl/hr ) or 43800 BThu/h or 12775 watt). |
| 6 | Standard installation, testing and commissioning of 1.5 / 2.0 TR high wall split type AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge. |
| 7 | Standard installation, testing and commissioning of 3.65 TR floor mounted vertical Split type AC machine including hole cutting, finishing etc. as per direction of the Engineer-in-charge. |
| 8 | Fabrication of M.S platform for placement of condensing unit by using M.S angle of (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of 1.5 / 2.0 TR high wall split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. |
| 9 | Fabrication of M.S platform of appropriate size, base plate, nuts and bolts/ universal bracket (GSS) for both IDU and ODU of 3.65 TR floor mounted vertical Split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge. |
| 10 | Supply, installation of additional length of copper pipe of appropriate size of (5/8\\" (15.88 mm), 1/4”(6.35 mm), 3/8” (9.53 mm) and 3/4”(19.05 mm) or nearest dia. as per manufacturer design for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units suitable for 1.5 / 2.0 TR high wall type / 3.65 TR floor mounting vertical Split type ACs. |
| 11 | Providing hard UPVC pipe of best quality of nominal 3/4 \\" dia. including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender