Tender For Dnit For Construction Of Indoor Sports Complex, Construction Of Six-A-Side Hockey Astroturf Stadium And Providing Of Sprinkler System Including Tube Well And Ugsr With Mono Pump For Football Ground In Sports Stadium At Village Ghrachon, Di
Tender Overview
Project Description
Tender for Dnit For Construction Of Indoor Sports Complex, Construction Of Six-A-Side Hockey Astroturf Stadium And Providing Of Sprinkler System Including Tube Well And Ugsr With Mono Pump For Football Ground In Sports Stadium At Village Ghrachon, Distt. Sangrur, Punjab.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKS:-CONSTRUCTION OF BUILDING OF INDOOR SPORT'S HALL:-Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer In-Charge. |
| 2 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type |
| 3 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (10.16) |
| 4 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 5 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i) |
| 6 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. (10.21) |
| 7 | Extra Rate for First Floor |
| 8 | Extra Rate for Second Floor |
| 9 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 3 km lead (note: where concrete mixer is already included in the rate the same shall be deducted ) |
| 10 | Extra for carriage of RMC/batch mixed concrete with transit mixture beyond 1st km . |
| 11 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 12 | Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey |
| 13 | First Floor |
| 14 | Second Floor |
| 15 | Centring and shuttering for Columns ( Square or Rectangular or plygonal in plain) in superstructure |
| 16 | Extra Rate for First Floor |
| 17 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 4 metres or part thereof. |
| 18 | Extra Rate for Second Floor |
| 19 | Centring and shuttering for sides and soffits of beam, beams launchingsgirders bressumers, lintels |
| 20 | Extra Rate for First Floor |
| 21 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 4 metres or part thereof. |
| 22 | Extra Rate for Second Floor |
| 23 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 24 | Extra Rate for First Floor |
| 25 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 26 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. |
| 27 | Extra Rate For First Floor |
| 28 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 29 | Extra Rate for First Floor |
| 30 | Extra Rate for Second Floor |
| 31 | Extra rate for using steel from Integrated plant marked as primary Producer steel. |
| 32 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 33 | Extra rate for First Floor |
| 34 | Extra rate for Second Floor |
| 35 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement sand mortar in super structure. |
| 36 | Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. (10.27) |
| 37 | 12.5 mm thick cement plaster 1:5 (15.10) |
| 38 | Extra Rate for First Floor |
| 39 | Extra rate for Second Floor |
| 40 | 20mm thick cement plaster 1:5 in two coat work (15.21) |
| 41 | Extra Rate for First Floor |
| 42 | Extra rate for Second Floor |
| 43 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. |
| 44 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend |
| 45 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 46 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (13.45) |
| 47 | Providing and fixing in position gratings 150mmx150mm for gully trap. PVC grating |
| 48 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. (13.51) |
| 49 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing (13.13 (i)) |
| 50 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (13.55) |
| 51 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead . |
| 52 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material (14.3) |
| 53 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge to be laid below the topping using mechanical mixer for mixing of material (14.11) |
| 54 | Extra Rate for First Floor |
| 55 | Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 12mm to 15mm Slabs sizes above 0.50 sqm |
| 56 | Extra Rate for First Floor |
| 57 | Providing and laying vitrified floor tiles in different size in light colour shades made using Full Body Technology (thickness to specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand ), complete. (Full body vitirified tiles have pigment in entire body/ thickness of which make chips and scratches less noticeable and na ideal choice for high traffic zones) Size 600x600 mm CSR 14.115 a |
| 58 | Extra Rate for First Floor |
| 59 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. |
| 60 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (14.84) |
| 61 | Extra Rate for First Floor |
| 62 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing (14.86) |
| 63 | Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness and colouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects. (14.142) |
| 64 | Providing and laying Polished Granite stone 18 mm thick flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (14.89 b) |
| 65 | Providing and laying Laminate wooden flooring (Grade AC4 or AC4+ laminates) 6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminum oxide finish that protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer. |
| 66 | Extra Rate for First Floor |
| 67 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 68 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. (14.135) |
| 69 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 70 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : |
| 71 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. ( 620+20%)Door and window frame of size 113mmx60mmx with 35mm wide single rebate. |
| 72 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm 5.0mm thick Plate glass (INDIAN) |
| 73 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer- in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) |
| 74 | Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop .. |
| 75 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.(755+20%) |
| 76 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position (18.4) |
| 77 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 78 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 79 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm |
| 80 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeISI designation no I (Size of door up to 700mm) |
| 81 | Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. |
| 82 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 83 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 84 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 85 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 86 | Extra Rate for First Floor |
| 87 | Extra Rate for Second Floor |
| 88 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 89 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti ncluding finishing the surface to required finish complete. |
| 90 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 91 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 92 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 93 | Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required.0.60 mm (+ 0.05 %) thick (712+30%) |
| 94 | Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:-Above 15.00 mt. Span including the cost for machinery i.e. Hydra cranes etc. for hoisting in position. |
| 95 | Providing and Fixing multilayer Polyuerthane flooring (10+2mm) consisting of primer on asphault surface, elastic layer SBR matt (5-12mm), Pore sealer(0.1mm), Cast coating (2-3mm), Antiskid multitop (0.5mm) incliding making of Ground Approved by ITF on already laid Flooring System complete in all respect |
| 96 | Providing and instalation of integrally weighted movable Badminton Posts. The badminton posts shall allows regulation net height to be achieved detachable front upright. It shall be manufacture from 47x47mm square pipe 4mm thick. Base shall made up of strong pipe and shall have weight stock of cast/mild steel 70kg each side. Wheels shall non marking with bearing inside and the wheel shall have 100 mm dia. Complete with rubber feet to protect the playing surface and grip on wooden & synthetic floor. The poles shall either powder coated or spray painted.The net shall made up of nylon material ,suitable for all weather use.The four sides of net shall be covered with white waterproof vinyl tapes. |
| 97 | Providing and Fixing of Turbo Fan /Non Electric Exhaust Fan 21\\"/22\\" dia to be fitted on roof top/shed etc. with imported polycarbonate body base complete in all respects upto to the entire satisfaction of the Engineer-In-Charge of the work |
| 98 | Providing and fixing mineral fibre false ceiling tiles at height upto 4 mtr of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 99 | Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 100 | Providing and fixing covering 200mm wide G.I.Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 101 | Preformed fillers for expansion joints in concrete pavement and structures (non-extruding and resilient type) part-3 Polymer Based (CED 13: building construction practices including painting, varnishing and allied finishing) complete as per IS 1838-3 (2011): |
| 102 | Construction of Plinth protection complete |
| 103 | Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer In-Charge. |
| 104 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer. (10.6 b ii) |
| 105 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 (i)) |
| 106 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material (14.3) |
| 107 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material). (14.6) |
| 108 | 12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. (15.10) |
| 109 | HOCKEY ASTROTURF |
| 110 | Construction of granular sub-base by providing material as per grading-III ( Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications |
| 111 | Providing, laying, spreading and compacting gradedstone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications |
| 112 | Prime Coat @ 0.85kg per sqmProviding and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85kg/sqm complete as per technical clause 502 of MORT&H specifications |
| 113 | Providing and applying tack coat with bitumen emulsion RS using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface/granular surface treated with prime coat after cleaning the surface complete as per technical clause 503 of MORT&H specifications |
| 114 | Providing and laying 50mm thick BM |
| 115 | Providing and laying 30mm thick BC |
| 116 | (i) Providing & Laying FIH Global Certified Turf from FIH Certified Turf Manufacturer having pile height of 13mm both recommended for water or sand dressed hockey international tournaments and national level tournaments, maintaining international hockey federation (FIH).Detailed specification attached in BOQ/DNIT.(ii) Providing and laying 15 mm thick rubberized (cast in situ) under layer as per F.I.H. reuirement and specification F.I.H. compettions, including all fittings and net etc all complete as per direction of Engineer in Charge. |
| 117 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 118 | Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type |
| 119 | CC 1:2:4 with stone ballast |
| 120 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 121 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position. |
| 122 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 123 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 124 | Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge |
| 125 | Construction of Outer Development & Parking |
| 126 | Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications |
| 127 | Providing, laying, spreading and compacting stone aggregates of Grading I to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8- 10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (CSR 24.11 (i) ) |
| 128 | Providing, laying, spreading and compacting stone ggregates of Grading II to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheeled roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (CSR 24.12 (i)) |
| 129 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code : 15658(2006) |
| 130 | Providing and laying 80 mm thick factory made cement concrete interlocking Paving blocks of M-40 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. |
| 131 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. |
| 132 | Precast Cement Concrete Kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 133 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 134 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 135 | Applying priming coat with metal primer onnew steel or iron work including preparation of surface. |
| 136 | Public Health Services |
| 137 | Sub Head-1 Internal Sewerage System |
| 138 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B |
| 139 | 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 140 | 90mm o/d single socket SWR UPVC pipe lines laid complete |
| 141 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 142 | For 110mm o/d pipes |
| 143 | Elbow 90 Degree (All side socketed) |
| 144 | Vent Cowls |
| 145 | Coupler |
| 146 | Single Tee With Door |
| 147 | Floor Trap 110mm x 110mm |
| 148 | For 90mm o/d pipes |
| 149 | Elbow 90 degree (all side socket) |
| 150 | Vent Cowls |
| 151 | Coupler |
| 152 | Single Tee With Door |
| 153 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 154 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) |
| 155 | 110mm o/d |
| 156 | 90mm o/d |
| 157 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. |
| 158 | M.S. Holder bats clamps for 100mm i/d as per table-1 |
| 159 | M.S. Holder bats clamps for 75mm i/d as per table-1 |
| 160 | Core cutting in RCC slab 125mm dia or 150mm dia withe the help of core cutting machine as per requirement at site & as desired by Engineer-in-Charge. |
| 161 | Providing and fixing galvonised hanging clamp 100mm dia chimney type for PVC pipe, 12mm galvonised fully thread bar with nut bolt as per requirement at site & as desired by Engineer-in-Charge. |
| 162 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.(a) 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 163 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. (b) |
| 164 | Sub Head-2 Internal Water Supply System |
| 165 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 166 | CPVC SDR 11 Pipe & fitting 16mm o/d |
| 167 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 168 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 169 | CPVC SDR 11 Pipe & fitting 32mm o/d |
| 170 | CPVC SDR 11 Pipe & fitting 40mm o/d |
| 171 | CPVC SDR 11 Pipe & fitting 50mm o/d |
| 172 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mmGI P 15mm i/d to 25 mm. |
| 173 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 174 | Through wall 11.43 cm thick Detail as per Table-2 |
| 175 | Through wall 22.86 cm thick Detail as per Table-2 |
| 176 | Providing, fixing and jointing cPVC Union Couplings (of approved make with the approval EIC) ISI marked in cPVC Pipe lines complete in all respect. |
| 177 | 20mm i/d cPVC Union |
| 178 | 25mm i/d cPVC Union |
| 179 | 32mm i/d cPVC Union |
| 180 | 40mm i/d cPVC Union |
| 181 | 50mm i/d cPVC Union |
| 182 | Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete. |
| 183 | 25mm i/d Brass Ball valves |
| 184 | 32mm i/d Brass Ball valves |
| 185 | 40mm i/d Brass Ball valves |
| 186 | 50mm i/d Brass Ball valves |
| 187 | Sub Head - 3 Sanitary Installation |
| 188 | Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 189 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 190 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. (a) Chinaware extended wall mounted E W.C. with matching chinaware cistern and seat cover complete in all respect |
| 191 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With PTMT nut |
| 192 | Providing and fixing Stainless steel health faucet complete in all respect. |
| 193 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 194 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tubeconnection 300 mm long complete. |
| 195 | Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm |
| 196 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.(ii) Size 550 mm x 400 mm x 815mm |
| 197 | Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 198 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. (e) Double bowl Sink without drain board Overall size 1330x515 bowl size 560x410x200mm |
| 199 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location inmarble/ granite/ stonework, including necessary holes for pillar taps etc. includingmoulding, rubbing and polishing of cut edges etc. complete. |
| 200 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut OWC+EWC+WB+Urinal+Steel sink |
| 201 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 202 | Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-in-charge) complete in all respect.For Washbasin & Urinal. |
| 203 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 204 | C.P. brass towel Rails size 15mm dia 610mm long |
| 205 | C.P brass towel ring |
| 206 | Providing and fixing in position C.P. Acryli shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-incharge ) fixed in with rawl plugs and C.P brass screws complete in all respect. |
| 207 | CP brass Acrylic Shelf size 560mmx130mm |
| 208 | C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm |
| 209 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 210 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 211 | C.P. brass Bib cock long nose/ long body without flange |
| 212 | C.P Brass bib cock foam flow without flange |
| 213 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 214 | C.P.brass 15mm Angle valve without flange ( For Jet Spray Connection + Over Head Shower) |
| 215 | C.P.brass 15mm Concealed stop cock with flange ( For Jet Spray Connection + Over Head Shower) |
| 216 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 217 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long |
| 218 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) |
| 219 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 3 pegs |
| 220 | Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. |
| 221 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks |
| 222 | 500 ltr Capacity |
| 223 | 2000 ltr Capacity |
| 224 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball 50mm i/d |
| 225 | Providing and fixing in position cPVC Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 226 | Tank nipple 32mm i/d |
| 227 | Tank nipple 40mm i/d |
| 228 | Tank nipple 50mm i/d |
| 229 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge |
| 230 | For Water Tank |
| 231 | Providing and fixing in position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 232 | Providing & fixing in position 15 mm i/d C.P brass wall mixer of approved make (to the approval of Engineer-in-charge ) complete in all respect.(B) C.P. brass wall mixer without telephonic shower |
| 233 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in- charge ) fixed in to wall with C.P brass screws complete in all respect.C.P. brass toilet paper holder |
| 234 | Providing and installing in position premium range water pressure boosting pump (To the approval of Engineer-in-charge) including all pump accessaries but excluding cost of pipe & specials complete in all respects.For Swimming Pool (HE & SHE (C)Pressure pump of 0.9HP with 4700 LPH, 27.3meter head with SS pump & 24 litre capacity Tank Model : CM 5-4 |
| 235 | Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect.25 litre capacity water heater |
| 236 | Sub Head-4 Flooring and Wall Tile |
| 237 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 238 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material |
| 239 | Extra rate for First Floor |
| 240 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . |
| 241 | Extra rate for First Floor |
| 242 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm). Taking 10% extra for Vertical Sites |
| 243 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 244 | Extra rate for First Floor |
| 245 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. |
| 246 | Extra rate for First Floor |
| 247 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 248 | INDOOR SPORTS COMPLEX AND SECURITY ROOM |
| 249 | INTERNAL ELECTRICAL SERVICES |
| 250 | POINT WIRING: |
| 251 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 252 | Wiring fan point (With fan box) |
| 253 | Wiring light point |
| 254 | Wiring call-bell point |
| 255 | Wiring 6Amp. wall socket point |
| 256 | Wiring 6Amp. Plug control comprising wall socket point |
| 257 | Wiring 16/20Amp. power plug control point |
| 258 | Wiring light point without control switch. |
| 259 | Wiring light point with double control switches. |
| 260 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 261 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 262 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 263 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 264 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 265 | Wiring Telephone socket point RJ11 (one module) |
| 266 | Wiring Networking socket point RJ45 (one module) |
| 267 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 268 | Ceiling Rose (Flush Piano type) |
| 269 | Bakelite Batten Holder (Large size) |
| 270 | Call Bell 220/230 volts AC Ding Dong |
| 271 | LED'S FIXTURES & FANS: |
| 272 | Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz + 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 273 | Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz + 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 274 | Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz + 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 275 | Supply and erection of Surface mounted round downlighter 18watt (including constant LED driver) with Pressure die cast aluminium housing with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 276 | Supply and erection of Recessed mounted 36watt LED 2X2 panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz + 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 277 | Supply and erection of High efficiency round highbay 150 Watt Surface mounted Weather proof corrosion resistant, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection) for industrial and other applications in exposed climates requiring higher degree of ingress protection, THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK 07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 278 | Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 279 | Supply and Erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 280 | Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 281 | Supply and erection of Wall Fan Plastic Body 400MM, 16\\" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 282 | Supply and erection of Air Circulator 600mm sweep wall mounting to be fitted on wall/ surface etc. making all the necessary connections including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 283 | Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 284 | Supply and erection of Heavy duty Exhaust Fan 450mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 285 | SUSPENSION RODS FOR CEILING FANS: |
| 286 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 287 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 288 | CONDUIT PIPE & COPPER WIRES: |
| 289 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 290 | Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed |
| 291 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 292 | Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed |
| 293 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 294 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 295 | Overall size 1sq.mm (Un-sheathed) |
| 296 | Overall size 1.5sq.mm (Un-sheathed) |
| 297 | Overall size 2.5sq.mm (Un-sheathed) |
| 298 | Overall size 4sq.mm (Un-sheathed) |
| 299 | Overall size 6sq.mm (Un-sheathed) |
| 300 | Overall size 10sq.mm (Un-sheathed) |
| 301 | Overall size 16sq.mm (Un-sheathed) |
| 302 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES: |
| 303 | Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 304 | CAT 6 LAN cable |
| 305 | Supply and erection of telephone cable with solid bare copper conductor, special grade PE insulation, paired, polyster taped, nylon rip cord, FR PVC sheathed, conforming to TEC Specification No. G/WIR-06/03 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 306 | Telephone Cable 0.5 Sq.mm, 2 Pair |
| 307 | DISTRIBUTION SYSTEM: |
| 308 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 309 | TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp.) |
| 310 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 311 | MCCB Four Pole 63/80/100amp., 415voIts, z25kA Fixed Magnetic and Adjustable Thermal Setting |
| 312 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 313 | SP&N Double Door Distribution Board 8 way each |
| 314 | TP&N Vertical Double Door Distribution Board 4 way each. |
| 315 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 316 | Cable End Box for TPN Vertical 4/8/12Way |
| 317 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 318 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 319 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 320 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 321 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 322 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 323 | PVC Flexible Pipe 25mm dia. |
| 324 | PVC flexible pipe 40mm dia. |
| 325 | LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS):Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. |
| 326 | The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. |
| 327 | The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. |
| 328 | Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. |
| 329 | Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:- |
| 330 | MAIN LT PANEL: |
| 331 | LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm)(DETAIL SEE IN PANEL INVENTORY) |
| 332 | MCCB's (MOULDED CASE CIRCUIT BREAKER): MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc |
| 333 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 334 | MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 335 | MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 336 | ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure):Supply and erection of On Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- |
| 337 | On Load Change Over Switch Four Pole 250amp., 415voIts |
| 338 | MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 339 | MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 340 | MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 341 | MS Sheet Enclosure having provision for MCCB 200-630Amp.with extended rotary handle (Approx. Size 750mm x 300mm x 250mm) |
| 342 | EARTHING SYSTEM (INDOOR): |
| 343 | COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 344 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 345 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 346 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 347 | COPPER EARTHING :-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 348 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 349 | COPPER EARTHING STRIP (As Additional Length):Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 350 | Additional Length 20mm x 3mm thick Copper Tape . |
| 351 | INDOOR LT CABLES, CABLE TRAY, DWC PIPE , BRASS GLANDS & THIMBLES: |
| 352 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (For Flood Lights) |
| 353 | Overall size 10sq.mm (3Core) Un-armoured (On-Surface) |
| 354 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 355 | Overall size 10sq.mm (3Core) Un-armoured (Loose) |
| 356 | Overall size 150sq.mm (3½ Core) Un-armoured (Loose) |
| 357 | Overall size 16sq.mm (4 Core) Un-armoured (Loose) |
| 358 | CABLE TRAY:Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 359 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 360 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 361 | Double walled corrugated (DWC) HDPE pipe 50/38 mm (outer/ inner dia.) |
| 362 | Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.) |
| 363 | SAFETY EQUIPMENTS: |
| 364 | Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect |
| 365 | Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect |
| 366 | SHEET METAL IRON CLAD SWITCHES:Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- |
| 367 | ICTPN Switch 63amp., 415volts |
| 368 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:M.S. FLAT/ CHANNEL BRACKETS:Supply and erection of M.S. Channel bracket made from 100mm x 50mm of length 600mm and height 600mm with M.S. angle iron 40mm x 40mm x Smm for installing metal halide flood light fitting on it. Bracket should be fixed/ welded with the existing pipe of cover shed. The bracket should be painted with one coat of primer and two coats of approved paint. (For Flood Lights in Indoor Sports Hall) |
| 369 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with + 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 370 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm toIS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement (For Flood Lights in Indoor Sports Hall & Swimming Pool) |
| 371 | Providing Advance Lightning Protection System: |
| 372 | Supply, erection, testing & commisioning of Early Streamer Emission (ESE) type Lightning Protection Complete with Lightning Air Terminal. The System should be corrosion resistant stainless steel chrome body capable of working in hazardous atmosphere and protecting against direct Lightning point as well conducting /diverting it to earth completely after tracing the Lightning in advance. As per NF C 17-102:2011 the air terminal should be tested for Lightning impulse current (10/350 micro sec) =100 KA and for local certification the air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) as per CPRI with 5 positive and 5 negative impulse. The ESE Terminals shall offer a protection radius of 79mtr., Level-1 High Protection and preferably to be mounted on roof top and center of the building / blocks with the highly insulated polyplastic adaptor with the Mast. (Its working principle evolves from local electrostatic field that develops naturally around the system as a thunderstorm begins to gather. In the event of descending lightning, an inbuilt triggering device generates high tension pulses at the conductor tip, causing a ‘corona effect’.) Protection radius of 79Mtr at level 1 & 107 Mtr at level 4 |
| 373 | Supply and fixing of GI Mast 5 mtr. height along with suitable base plate for mounting the terminal along with highly insulated adopter to mount ESE Air Terminal with the Mast.The Adapter shall have suitable Metal connector /Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conducto, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required. |
| 374 | Supply and installation of Lightning Strike Counter (6-7 digit display) of non-resettable (electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system. This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures. It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs. above the ground level. |
| 375 | Supply & erection of test Link of non-corroding, weather proof, water proof polycarbonate IP 65/55 enclosure including providing of 2 Nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire. The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor complete in all respect as approved and desired by the Engineer in-charges at site. |
| 376 | Supply, installation & testing of chemical earthing (Maintenance Free Earthing) system with UL approved copper bonded rod and exothermically welded copper busbar both tested by CPRI at 50kA Fault Current. A copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper coating thickness of minimum 250 microns. Along with earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A copper clad steel solid ground wire of 8 mm dia. for interconnecting earth pits. Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber. The grounding minerals should not be pollute the ground water. The grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr. |
| 377 | Cost of pole foundation with earth work in excavation in foundations trenches etc. 0.25 meter below ground level, Cement Concrete 1:4:8 with stone ballast, Reinforced cement concrete M-20, Cold twisted deformed (Ribbed/tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 complete in all respect as desired by engineer in charge. |
| 378 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 379 | Overall size 70sq.mm (Un-sheathed) (Conductor connected the air terminal to earthing) |
| 380 | Providing CCTV System: |
| 381 | Supply installation testing & commissioning of 5MP IP Network TDN Low light IR Rugged Bullet Camera 1/2.8\\" CMOS or better, 5 MP (2592 x 1944), Max Frame Rate: 50fps or better,Quard stream at various resolution & frame rates, Minimum illumination required [email protected](color), 0 Lux IR On, Smart IR with upto 50m IR distance or better Auto ICR (infrared Cut Filter) 130db True WDR,S/N Ratio 55db, Shutter Speed 1/3 -1/100,000s; Advance video compression technology such as H.265% H.264 High Profile MJPEG, Streams 4 video Streams configured at Different resolution and FPS Max @50 FPS ,3.6mm Fixed, F1.4 Electronic Image stabillization With G-Sensor, BLC, HLC, 3DNR White Balance Minimum Edge intelligence, Protocols: IPv4, IPv6 ,TCP/IP, HTTP, HTTP SRTSP/ RTP /RTCP, IGMP/ Multicast, SMTP, SNMP, DHCP, NTP, DNS, DDNS, CoS,QoS,802.1X, UPnP, mDNS (Bonjour) UDP, ICMP, ARP, TLS, |
| 382 | SFTP Video Analytic server feature : Motion Detection, Scene Change, Tamper Detection, Smart motion, Intrusion, Loitering, Line crossing detection, unattended Object detection, Missing Object detection,People Counter, Queuing,Crowd Gathering, Heat Map, Face detection,Camera reset option in camera, 5Privacy Mask, 6Region of Interset, Defog,TLS1.2 &1.3,AES-128/256, SSH/Telent Closed , Stream Encryption,Secure boot, Prevent Brute - force attack, 2TB Micro SD/SDHC/SDXC Card slot; Gorvent, PoE(802.3af) and 12V DC ,Max 10.6W or better, IP66 & IP67, IK10 Vandal proof with Aluminium+Polycarbonate Housing, havinh Operating Temperature -30°C to 60°C,Certification: ONVIF Profile S,G,T,M Compliant, UL, FCC, CE, RoHS, BIS-ER, STQC complied and NDAA Section 889 compliant. Camera Should be with 5 years Warrenty. The MAF and Warrenty should be submitted by OEM Directly. complete in all respect as desired by the engineer in charge at site. |
| 383 | Supply, erection, testing & commissioning of 32 Channel Linux based Recording server (Network Video Recorder shall be support The STQC Cameras), 4SATA interface, Upto 32 channel Video Inputs, Server shall have through put of incoming bandwidth 512 Mbps & outgoing 512 Mbps, 2*HDMI , 1*VGA Video output. Support slive view,storage,and playback at 1-8 MP resolution,Shall be capable of live streaming & Storing 32 cameras, Shall support Net HDD, Storage upto 8 TB Surveillance HDD, Shall support audio,G.711A/G.711U,Shall support 1E-sata port, 2xRJ45 10M/100M/1000M ports, Audio input 1 channel, Audio Output 1 channel output , Alarm input 16 channel, Alarm Output 1channel output, USB2.0*1, USB3.0*1+USB2.0*1port, RS485*1, Protocol :IPv4, IPv6, TCP/IP, HTTP, HTTPS, DDNS, RTMP, SMTP(SSL), SNMP, DHCP, PPPoE, UPnP, NTP, P2P, FTP , Simultaneously record multiple streams in any combination of H.264/H.265/H.264+/H.265+, support Start,stop, normal play, backplay, frame by frame forward, full screen, |
| 384 | Fast forward/ backward (2x,4x,8x,16x),Slow forward (1/2x,1/4x,1/8x,1/16x), Addcustom /Default Tag for any events at the time of playback, digital zoom, video clip,sub stream/main-stream,play back video bar, Shall be able to take actions pre and post recording,Send email, show message, send email, FTP upload video or screenshot, Cloud upload video or screenshot, fullscreen, voice prompts, Alarm output trigger, PTZ linkage on events, support the display of VCA metadata on video live-view and and playback, Supports AI from camera side:Face Detection, Human Detection, Vehicle Detection, Perimeter Intrusion Detection,Line Crossing Detection,Cross Counting, Heat Map, Crowd Density Detection, Queue Length Detection, License Plate Detection, Rare Sound Detection, Stationary Object Detection, Sound Detection, Capable to show statistics and graphs of events for different interval of time search, Shall support S.M.A.R. THDD function for HDD status, Onvif Support, Power Supply :DC 12V/2A, Consumption without HDD:12W, Temperature:-10°C~+50°C (14°F~122°F) Humidity:Less than 90% RH, 378*326*66mm (W×D×H) Dimensions, Certificates:CE, BIS, FCC, ROHS and REACH complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 385 | SITC of 24 Port POE 190+ Watts L2 managed 10/100/1000 Mbps with 4 No Uplinks RJ45 and SFP Combo 1G Ports Data switch with 4• IEEE 802.3u 100BASE-TX Fast Ethernet• IEEE 802.3ab 1000BASE-T Gigabit Ethernet• IEEE 802.3az Energy-Efficient Ethernet (EEE)• ANSI/IEEE 802.3 NWay auto-negotiation• IEEE 802.3x Flow Control, Standards • IEEE 802.3 10BASE-T Ethernet Switching Fabric • 50GbpsData Transfer Rates • Gigabit Ethernet • 2000 Mbps (full-duplex) • Fast Ethernet • 100 Mbps (half-duplex) • 200 Mbps (full-duplex)• Ethernet • 10 Mbps (half-duplex)• 20 Mbps (full-duplex), PoE Standards • IEEE 802.3af • IEEE 802.3at PoE-capable Ports • Ports 1 to 4 Power 60W • 190+ W (30 W max. per PoE port). CPU RAM 256MB or above, Certification - FCC class A, CE class A, VCCI, BSMI, CCC,CE, LVD, UL, CBOper Temp--5 to 50 °C (23 to 122 °F) complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 386 | Supply, erection, testing & commissioning of 6000GB Audio Video HDD 3.5 Inches Connector SATA, Interface SATA, Operating Temperature 0°C to 65°C, Transfer Rate minimum 160MB/s, Recording Technology – CMR, Certifications BSMI, ICES-003/NMB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL for NVR recording and playback complete in all respect as desired by the engineer in charge at site. |
| 387 | Supply, erection, testing & commissioning of Smart 55” LED Commercial Panel /Regular with 2 HDMI Port, TV Input, 3 Years Warranty, 2 HDMI Port, TV Input, 3 Years Warranty, Resolution 4K, Brightness 300 cd/m2 Support 4K Ultra HD 20 Watt 2.0 Audio Output Web Browser Soft AP, WiFi (bandwidth) Screen Share (Miracast) USB Cloning, 2 No. Of HDMI Port 2 no USB Port complete in all respect as desired by the engineer in charge at site. |
| 388 | Supply, Installation, Testing & Commissioning of 10 meter long superior quality 4K HDMI Cable having speed upto 10gbps support all types of HDMI Devices complete in all respect as desired by the engineer in charge at site. |
| 389 | Supply, erection, testing & commissioning of 9U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth, AC Fan, having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks. complete in all respect as desired by the engineer in charge at site. |
| 390 | Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having minimum 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respect as desired by the engineer in charge at site. |
| 391 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 392 | CAT 6 LAN cable |
| 393 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 394 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 395 | Providing PA System: |
| 396 | Supply, installation, testing & Commissioning of Mic Single zone desktop paging microphone with a sturdy, aluminium die-cast top and special high reliability switches with integrated LED indicators. Fitted with a flexible 300mm (12”) gooseneck and a high quality unidirectional dynamic cartridge. Supplied with 6 mtrs. twin core shielded low noise cable with 6.3mm (¼”) phone plug. Frequency response 50-10000 Hz, Senstivity 2.0mV/Pa, Impedance 600 ohm complete in all respects as approved and desired by the Engineer in-charge at site. |
| 397 | Supply,installation, testing & Commissioning of 500W Power mixer amplifier POWER OUTPUT 750W Max., 500W RMS at 10% THD, 450W RMS at 5% THD, 415W RMS at 2% THD, OUTPUT REGULATION ≤ 2 dB, no load to full load at 1kHz, INPUT CHANNELS 7 × Mic 0.8mV/4.7kΩ, 2 × Aux 100mV/470 kΩ, 1 × CD 200mV/50 kΩ, 1 × Line 1V/50kΩ, FREQUENCY RESPONSE 50-15,000Hz ±3dB, SIGNAL TO NOISE RATIO 60dB , TONE CONTROLS Bass: ±10dB at 100Hz, Treble: ±10dB at 10kHz, OUTPUT Preamp 200mV/600Ω, Line 1V/1kΩ, SPEAKER OUTPUT 4Ω, 8Ω, 70V & 100V, DIGITAL PLAYER MP3 Player with USB, SD and MMC Card Reader, Bluetooth, POWER SUPPLY AC: 220-240V 50/60Hz, DC: 36V (3×12V Car Battery), POWER CONSUMPTION AC: 1000VA DC: 8A, complete in all respects as approved and desired by the Engineer in-charge at site. |
| 398 | Supply, installation, testing & Commissioning of 20 Watt Full range Array of wall speakers radiate forward sound beam for wider audience coverage Mounting clamps & hardware supplied Slim, compact, aesthetically designed column speaker to integrate with most interiors.Aluminium extruded cabinet with moulded plastic covers, metal mesh grille. 100V line matching transformer with rotary switch for power tap selection. Input Power 20W RMS, 30W Max. Power Taps 20/15/10/5W Voltage 100V Frequency Response 150-15,000Hz SPL at 1kHz 93dB/1W/1m Speakers.complete in all respects as approved and desired by the Engineer in-charge at site. |
| 399 | Supply, Installation, Testing & Commissioning of 2 core 1.5 sqmm shielded cable for speaker Project specific OEM authorization required for executing agency. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 400 | Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having minimum 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respect as desired by the engineer in charge at site. |
| 401 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 402 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 403 | Providing Solar Power Generation System: |
| 404 | Grid interactive PV system solar power plant of 158 KWp |
| 405 | Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimumcapacity including required quantities of SPV modules (High power density bifacial monocrystalline solar modules with a capacity of +500 watts) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc. |
| 406 | Features :- 1. Solar PV Module Warranty 25 Years & Certified Under IS/IEC 61730 1&2 IS/ IEC 61701 & IS/IEC 14286 & IEC 61215, BIS Certificates & MNRE, GOI latest specifications / Standards.2. Power Conditioning Unit (String Solar Inverter) & Certified under IEC/EN 62109-1,IEC / EN 62102-2 , EN 61000-6-2, EN61000-6-3, IEC61683, EN 50530 , IEC 60068-2-1,2,14,30,EN 60529, IES 60947 Part 1,2,3 IS 60947 Part 1&2 , IES 60227/IS 694,IES 60502/IS 1554 BIS Certificates & MNRE, GOI latest specifications / Standards.3. Structure : 25 Years Service Life with AMC & Certified under IS 2062:20114. Complete Plant Insurance for the period of 5 Years (Excluding Theft of the material) 5. Annual Maintenance Contarct for the period of 10 Years Conditions:- 1. The Plant will be installed as per MNRE and GOI guidelines specifications.(Detail of Material as per Annxeure -1 Attached) 2. The Work will got done from approved MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) Contractors.PWD enlisted contractor subject to condition that PWD Enlisted contractor will get work done from MNRE (Ministry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) approved Conractors.The Rates are inclusive of Bi-directional meter testing charges, PSPCL Connection Charges, Unidirectional meter cost and all type of taxes including GST |
| 407 | Providing 1No. 82.5KVA/ 66KW Silent Diesel Generating Set: |
| 408 | Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 82.5 KVA /66KW with Manual Control Panel. It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).ENGINE: The Diesel engine developing 101.3 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-IV Norms as amended upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. |
| 409 | ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. |
| 410 | ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. |
| 411 | MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:- |
| 412 | INDOOR LT CABLES, CABLE TRAY & DWC PIPE: |
| 413 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 414 | Overall size 95sq.mm (3½ Core) Un-armoured (Loose) |
| 415 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 416 | Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) |
| 417 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 418 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 95-120sq.mm |
| 419 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 420 | Aluminium thimble cable Core size 50sq.mm |
| 421 | Aluminium thimble cable Core size 95sq.mm |
| 422 | COPPER EARTHING |
| 423 | COPPER EARTHING (Upto 14 metre in Length):-iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- (Body earthing & Neutral Earthing) |
| 424 | Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length) |
| 425 | Providing Campus Lighting: |
| 426 | 3-STEPPED STEEL TUBULAR POLE (WITH PRE-CAST FOUNDATION):Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP-Mpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix on precast RCC column of suitable dimensions. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The steel tubular pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level including painting of pole with two coats of approved aluminium paint as required:- |
| 427 | Overall length 7 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2), Foundation size below G/L 550mm x 550mm x 1400mm, 4Nos. Foundation Bolts size 20mm dia., Length≥700mm with Base Plate Dimensions 240mm x 240mm x 16mm Thick (approx. weight 7.235 kg.) |
| 428 | SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE:Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½\\" x 1½\\" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thick triangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:- |
| 429 | Single Arm Bracket 1.5 metre Long for Steel Tubular Pole (7 to 8m) |
| 430 | Supply and erection of G.I. Pipe (A-Class) Single arm bracket of suitable length to give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the existing surface/ wall with 2nos. MS flat clamp 25mm x 5mm, 30cm long and 4nos. fastner 10mm x 75mm long with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:- |
| 431 | Single Arm Bracket 1 metre Long G.I. Pipe 40mm Dia. (For Security Room) |
| 432 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 433 | GI Earth rod 20 mm dia., 3 mtr. Long |
| 434 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 435 | Overall size 1.5sq.mm (48/0.20mm), 3Core |
| 436 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 437 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 438 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 439 | Double walled corrugated (DWC) HDPE pipe 63/51mm (outer/ inner dia.) |
| 440 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 441 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 442 | COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 443 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 444 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 445 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 446 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:CUBICAL PEDESTAL: Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 447 | Cubical Size 1200mm high, 900mm wide and 350mm deep with platform dimensions 1000mm x 450mm x 450mm |
| 448 | MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 449 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 450 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 451 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 452 | SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS): |
| 453 | Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:- |
| 454 | Bus Bar Chamber 63amp., 415volts Overall Dimensions (300mm x 345mm x 120mm) nominal |
| 455 | TIMER:- Supply and erection of Switch S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:- |
| 456 | Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 457 | Supply and erection of LED Street Light 45watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 458 | HOCKEY GROUND |
| 459 | Providing Hockey Ground Lighting: |
| 460 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 461 | Overall size 1.5sq.mm (48/0.20mm), 3Core |
| 462 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 463 | Overall size 10sq.mm (4 Core) Un-armoured (Loose) |
| 464 | Overall size 35sq.mm (3½ Core) Un-armoured (Loose) |
| 465 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 466 | Double walled corrugated (DWC) HDPE pipe 50/38 mm (outer/ inner dia.) |
| 467 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 468 | MCCB's (MOULDED CASE CIRCUIT BREAKER): MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc |
| 469 | MCCB Four Pole 63/80/100amp., 415voIts, 25kA Fixed Magnetic and Adjustable Thermal Setting |
| 470 | MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 471 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 472 | SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS):Supply and erection of sheet metal bus-bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus-bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:- |
| 473 | Bus Bar Chamber 100amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal |
| 474 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:CUBICAL PEDESTAL:Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 475 | Cubical Size 1200mm high, 1000mm wide and 500mm deep with platform dimensions 1100mm x 600mm x 450mm |
| 476 | COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 477 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 478 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 479 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 480 | 3-STEPPED STEEL TUBULAR POLE (WITH PRE-CAST FOUNDATION):Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP-Mpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix on precast RCC column of suitable dimensions. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The steel tubular pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level including painting of pole with two coats of approved aluminium paint as required:- |
| 481 | Overall length 9.5 metre, length of sections 5 metre, 2.25 metre and 2.25 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 165.1mm x 4.85mm, 139.7mm x 4.5mm and 114.3mm x 3.65mm (Bottom, Middle and Top respectively) with approximate weight 160 kg. (410 SP-38), Foundation size below G/L 650mm x 650mm x 2200mm, 4Nos. Foundation Bolts size 24mm dia., Length≥850mm with Base Plate Dimensions 350mm x 350mm x 20mm Thick |
| 482 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 483 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 484 | MS CHANNELS/ FLATS:Supply and Erection of MS angle iron (Channel)/ MS Flats of suitable size with cutting, bending and necessary holes as desired by Engineer-in-charge at site:- |
| 485 | MS angle iron size 75mm x 40mm x 4mm thick |
| 486 | G.I. EARTHING:Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 487 | GI Earth rod 20 mm dia., 3 mtr. Long |
| 488 | Supply and erection of LED Flood Light 350Watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender