Tender For Repairing Of Compound Lighting Arrangement At Intake Yard Of Tapan Western Sub-Srface Water Treatment Plant In The District Of Dakshin Dinajpur Under Malda Mechanical Division, Phe Dte.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Sep 2026
2 days left
EMD
6400
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Maldah → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing Of Compound Lighting Arrangement At Intake Yard Of Tapan Western Sub-Srface Water Treatment Plant In The District Of Dakshin Dinajpur Under Malda Mechanical Division, Phe Dte.
BOQ
| Sl. No. | Item Description |
| 1 | Supply and delivery at site of the following Poles and electrical accessories for making compound lighting as per approved vendor list of PHED -- |
| 2 | Supply & delivery at site of 7.0mtrs long steel tabular pole with Cast Iron base plate & CI Cap as per Designation- 410 SP-02 (IS:2713-1980), Overall length 7.0mtrs long & to be planted depth opto- 1.5mtr, sectional lenth (Bottom-5.0mtr, Middle- 2.0mtr, Top- 2.0mtr,) Outside Dia & Thickness of Section (Bottom-114.3x4.50mm, Middle-88.9x4.05mm, Top-76.1x3.25, weight 73kgs) with Single Arm bracket 1.0 mtr long 40mm dia.(Make: Calcutta poles & tubes co. / Other Similar type as per approved vendor list of PHED.) |
| 3 | Supply and delivery at site of energy efficient LED UrbanEdge street light fixture with IP66 and IK10 protected LM high pressure alluminium di cast housing with polycarbonate cover suitable to fitted arm bracket of dia 40mm and capable of delivery standard lumen output as follows. The lens plate should be bolted to the metal core PCB should not be glued . Power consumption 47W, Input Voltage 120 to 277V . It should have internal surge protection of minium 4kv , Luminous flux - 6000 lumen, Luminous efficiecy - 125 lumen /watt, Power Factor >0.95.(Make : Philips BRP331 LED60 CW R5N PC PSU S1 / Similar type as per approved vendor list of PHED.) |
| 4 | Supply and delivery at site of energy efficient LED UrbanEdge street light fixture with IP66 and IK10 protected LM high pressure alluminium di cast housing with polycarbonate cover suitable to fitted arm bracket of dia 40mm and capable of delivery standard lumen output as follows.The lens plate should be bolted to the metal core PCB should not be glued . Power consumption 70W, Input Voltage 120 to 277V . It should have internal surge protection of minium 4kv , Luminous flux - 10500 lumen, Luminous efficiecy - 150 lumen /watt, Power Factor >0.95.(Make : Philips BRP502 LED105 CW R5C PSU S1 / Similar type as per approved vendor list of PHED.) |
| 5 | Supply and delivery at site of 1.1 KV grade 4 core 4 sq.mm XLPE insulated Al. Ar. Cable Conforming to IS:7098(Part-I) 1988 for outdoor lighting along with manufactures test certificate. [Make: As per approved vendor list of PHED] |
| 6 | Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.(Upto 9.0 mtr Size 0.6x0.6x1.70 mtrs.) |
| 7 | Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, without Loop Box. |
| 8 | Laying of single cable up to 35 sq.mm (4 core x 4 sq.mm) in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. |
| 9 | Laying of cable upto 3/4 core 25sq.mm (4core x 4sq.mm) on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as directed by EIC. |
| 10 | Supplying and Fixing 250 x 250 x 100mm GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement with required GI Pipe for cable laying from ground to loop box, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 6A SPMCB unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting as directed by EIC. |
| 11 | Supply & fixing of 16Amp DP MCB for yard lighting at Intake.(Make : ABB / Similar type as per approved vendor list of PHED.) |
| 12 | Fitting fixing above supplied LED light fitting complete with all accessories to be fixed with S&F length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required complete. |
| 13 | Earthing with 1no. of G.I. earth spike (20 mm dia. X 1.5 mtr. Long) driven into the ground upto 2 mtr. drawing earth line with separate 6 SWG G.I. Wires providing 15 mm dia. G.I. pipe protection from earth spike feeder box/junction box/poles and fixing to the same by suitable nuts & bolts all complete as per direction of EIC. |
| 14 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 15 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint.(Upto 9.0 mtr. long pole) |
| 16 | One coat of red lead/zinc chromate priming. |
| 17 | 1st coat of synthetic enamel paint over the primer. |
| 18 | 2nd coat of synthetic enamel paint over the 1st coat. |
| 19 | Testing & commissioning of the whole installation by licensed electrician as per instruction of EIC. |
| 20 | Add GST @ 18% |
| 21 | Add Cess @ 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender