Bids Are invited for Biosafety Cabinet - Biosafety Cabinet Should Be Of Class Ii, Type A2 With Approx. 30% Exhaust And 70% Recirculation Air-Flow Specifically Required For Use In Biological Applications , Cabinet Should Have Internal Dimension (Wxdxh

Issued by Boards / Undertakings / PSU · Mumbai, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Sep 2026
17 days left
EMD
18480
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Biosafety Cabinet - Biosafety Cabinet Should Be Of Class Ii, Type A2 With Approx. 30% Exhaust And 70% Recirculation Air-Flow Specifically Required For Use In Biological Applications , Cabinet Should Have Internal Dimension (Wxdxh) Approximately 3*2.5*7Ft. , Cabinet Height Should Not Exceed More Than 7 Feet. , Cabinet Construction: , Filters: , Should Have Microprocessor Controlled And Digital Display With Stable Airflow And Automatic Adjustment Of Blower Speed For Compensation Against Filter Choking, Filter Life Display, Blower Hour Meter ,Uv Hr Meter , Alarms Etc. On Lcd Display. , Should Be Noiseless Front Openging Of The Cabinet And It Should Be Angled So As To Help Minimize Glare On Window To The User. , Should Have Integrated Armrests That Are Raised Above The Work Surface To Help Prevent The Users Arms From Blocking The Front Air Inflow, Thereby Maintaining Proper Airflow And Containment. , Should Have Smooth (Noiseless) Sash Operation Manually With Gaskets All Around The Sash. , Should Have Uv Light For Decontamination With On/Off Timer. , Should Be Certified To Nsf 49 Or En12469 (Certification To Be Enclosed). , Ulpa Filters Should Be En-1822 Certified. , Cabinet Should Be Supplied With Support Floor-Stand With Locking Caster Wheels. , Should Have Built In 6A And 16A Electrical Socket. , Internal Fluorescent Lighting Fixture Should Be Such That Light Should Not Be Facing The User And It Should Be Out Of The Air Stream. , All Internal Wall Of Working Chamber Should Be Single Piece Ss 304 Including Side Wall With Rounded Corner. , Cabinet Should Produce Low Sound Less Than 60Dba , Virus Burn Out Unit With Ducting: , Vendor Shall Perform Validation Of Biosafety Cabinet Under Warranty And Cmc At Half Yearly Intervals As Per Nabl 112 Guidelines.It Includes Tests - Differential Pressure Test,Particle Count Test, Air Flow Velocity Test And Hepa Filter Integrity Test. All Validation Activities Shall Be Carried Out By Nabl-Accredited/Certified Laboratory And Vendor Shall Submit Nabl Accredited/Certified Test Reports And Traceability Certificate, Ensuring That The Nabl Logo Appears On Both The Main Test Certificate And The Traceability/Calibration Certificate. Same Validation Is Mandatory After Replacement Of The Filters. Faulty Filters To Be Taken Out Of Tmh Premised By The Vendor During Warranty And Cmc Period. , Should Perform Preventive Maintenance (2Nos) During Warranty,Amc,Cmc & If Entered Into Amc(Includes Unlimited Breakdown Calls) /Cmc (Which Will Include Spare Replacement, Breakdown Calls). Vendor To Submit Sops For Pms At The Time Of Installation/ Commissioning. This Is Mandatory Requirement. , Performance Certificates Of Iq,Oq,Pq Tests To Be Submitted At The Time Of Installation/Commissioning. , Vendor To Submit The Technical Data Sheet, Brochure Etc As A Tender Document With Reference To The Quoted Make & Model. Please Mention The Reference Page No., Etc In These Documents Against Each Technical Specifications In The Compliance. , Vendor To Submit List Of Consumables/Consumable Spares( I.E.Spares Need To Be Replaced At Regular Intervals, Maybe Quarterly/Half Yearly/Yearly Etc.) If Any.Cost Of Consumables To Be Given By The Vendor In Financial Bid. , Please Submit Pre Installation Requirements [Electrical, Hvac, Compressed Air Along With Air Pressure Mentioned), Water Requirement (Ro/Di/Distilled Water With Its Pressure, Flow Rate Per Hour) ; If Any Of The Above Is Essential] , Vendor To Provide Ups With Adequate Capacity, If Required For The Quoted Equipment. If Not Required, Vendor To Mention The Same. , Vendor To Submit Details Of Footprint Size & Weight Of The Quoted Model. , Vendor To Submit Power Consumption. , Demo Of The Quoted Model , Will Be Required If So Desired By The User, After The Opening Of The Technical Bid And Prior To Opening Of Financial Bid. This Is For Technical Evaluation. All Technical Specifications Mentioned Above To Be Mandatorily Shown In The Demo Unit. , Users/Installation List: A List Of Installations Of The Quoted Model With The Address And Contact Numbers To Be Provided. , Predispatch Inspection At Factory Will Be Required If Desired By Authorities. , Should Be Ce/Us Fda/Bis/Icmed Approved.( In The Case Of Ce Certificate, The Vendor Must Submit The Declaration Of Conformity) , Vendor Should Provide The User Manual And Service Manual Copy During The Installation Of The Equipment. , Unpacking And Shifting The Consignment To The Installation Site Is To Be Included In The Vendors Scope Of Supply. Bidder/Manufacturer/Authorized Service Provider Should Take Responsibility To Lift /Shift The Consignment From Unloading Site To The Installation Site. Unloading Site Shall Be Stores Department, Tata Memorial Hospital,Parel. If Needed ,Bidder Has To Arrange For The Labours At No Charge To Tata Memorial Hospital,Parel.. (Before Submitting The Quotation,Bidders May Visit Tata Memorial Hospital,Parel. To Know Unloading And Installation Site. , Training: , Local Service Support: Should Have Local Office And Service Support/Service Engineer For Attending The Breakdown Calls. Details To Be Submitted. , Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. , Warranty- 2 Years , Cmc- Cost Per Annum Will Be Considered For All Bidders For 8 Years After Warranty , Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. , If 2 Years Warranty, Cmc Per Annum For 8 Years After Warranty And Buyback If Any Wherever Applicable Are Not Adhered To, Tmc Reserves Right To Reject The Offer. , Please Mention Whether Ups Is Required For The Equipment. If So Should Be Included In The Offer. , Only Yes Or No Should Be Mentioned In Compliance Report And Additional Information In Remarks Column. , Please Provide List Of The Consumables/Spares/Reagents/Control/Calibrators (If Any) In Technical Documents And Cost Of The Same Should Be Uploaded In Pdf File In The Financial Documents. , Do Not Mention / Upload Price And Cost In The Technical Documents Otherwise Your Quotation Will Be Disqualified At Technical Stage.

BOQ

Sl. No. Item TitleItem Description
1Biosafety cabinet should be of Class II, Type A2 with approx. 30% exhaust and 70% recirculation air-flow specifically required for use in biological applicationsBiosafety cabinet should be of Class II, Type A2 with approx. 30% exhaust and 70% recirculation air-flow specifically required for use in biological applications
2Cabinet should have internal dimension (WxDxH) approximately 3*2.5*7ft.Cabinet should have internal dimension (WxDxH) approximately 3*2.5*7ft.
3Cabinet height should not exceed more than 7 feet.Cabinet height should not exceed more than 7 feet.
4Cabinet Construction:Cabinet Construction:
5Filters:Filters:
6Should have Microprocessor controlled and digital display with Stable airflow and Automatic adjustment of blower speed for compensation against filter choking, Filter life display, blower hour meter ,UV hr meter , alarms etc. on LCD display.Should have Microprocessor controlled and digital display with Stable airflow and Automatic adjustment of blower speed for compensation against filter choking, Filter life display, blower hour meter ,UV hr meter , alarms etc. on LCD display.
7Should be noiseless front openging of the cabinet and it should be angled so as to help minimize glare on window to the user.Should be noiseless front openging of the cabinet and it should be angled so as to help minimize glare on window to the user.
8Should have integrated armrests that are raised above the work surface to help prevent the user's arms from blocking the front air inflow, thereby maintaining proper airflow and containment.Should have integrated armrests that are raised above the work surface to help prevent the user's arms from blocking the front air inflow, thereby maintaining proper airflow and containment.
9Should have smooth (Noiseless) sash operation manually with gaskets all around the sash.Should have smooth (Noiseless) sash operation manually with gaskets all around the sash.
10Should have UV light for decontamination with on/off timer.Should have UV light for decontamination with on/off timer.
11Should be certified to NSF 49 or EN12469 (Certification to be enclosed).Should be certified to NSF 49 or EN12469 (Certification to be enclosed).
12ULPA filters should be EN-1822 certified.ULPA filters should be EN-1822 certified.
13Cabinet should be supplied with support floor-stand with locking caster wheels.Cabinet should be supplied with support floor-stand with locking caster wheels.
14Should have built in 6A and 16A electrical socket.Should have built in 6A and 16A electrical socket.
15Internal fluorescent lighting Fixture should be such that light should not be facing the user and it should be out of the air stream.Internal fluorescent lighting Fixture should be such that light should not be facing the user and it should be out of the air stream.
16All internal wall of working chamber should be single piece SS 304 including side wall with rounded corner.All internal wall of working chamber should be single piece SS 304 including side wall with rounded corner.
17Cabinet should produce low sound less than 60dBACabinet should produce low sound less than 60dBA
18Virus Burn Out Unit with ducting:Virus Burn Out Unit with ducting:
19Vendor shall perform validation of biosafety cabinet under warranty and CMC at half yearly intervals as per NABL 112 guidelines.It includes tests - differential pressure test,particle count test, air flow velocity test and HEPA filter integrity test. All validation activities shall be carried out by NABL-accredited/certified laboratory and Vendor shall Submit NABL accredited/certified test reports and traceability certificate, ensuring that the NABL logo appears on both the main test certificate and the traceability/calibration certificate. Same Validation is mandatory after replacement of the filters. Faulty filters to be taken out of TMH premised by the vendor during warranty and CMC period.Vendor shall perform validation of biosafety cabinet under warranty and CMC at half yearly intervals as per NABL 112 guidelines.It includes tests - differential pressure test,particle count test, air flow velocity test and HEPA filter integrity test. All validation activities shall be carried out by NABL-accredited/certified laboratory and Vendor shall Submit NABL accredited/certified test reports and traceability certificate, ensuring that the NABL logo appears on both the main test certificate and the traceability/calibration certificate. Same Validation is mandatory after replacement of the filters. Faulty filters to be taken out of TMH premised by the vendor during warranty and CMC period.
20Should perform preventive maintenance (2nos) during warranty,AMC,CMC & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement.Should perform preventive maintenance (2nos) during warranty,AMC,CMC & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement.
21Performance certificates of IQ,OQ,PQ tests to be submitted at the time of installation/commissioning.Performance certificates of IQ,OQ,PQ tests to be submitted at the time of installation/commissioning.
22Vendor to submit the technical data sheet, brochure etc as a tender document with reference to the quoted make & model. Please mention the reference page no., etc in these documents against each technical specifications in the compliance.Vendor to submit the technical data sheet, brochure etc as a tender document with reference to the quoted make & model. Please mention the reference page no., etc in these documents against each technical specifications in the compliance.
23Vendor to submit list of consumables/consumable Spares( i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly etc.) if any.Cost of consumables to be given by the vendor in financial bid.Vendor to submit list of consumables/consumable Spares( i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly etc.) if any.Cost of consumables to be given by the vendor in financial bid.
24Please submit pre installation requirements [electrical, HVAC, Compressed air along with air pressure mentioned), water requirement (RO/DI/Distilled water with its pressure, flow rate per hour) ; if any of the above is essential]Please submit pre installation requirements [electrical, HVAC, Compressed air along with air pressure mentioned), water requirement (RO/DI/Distilled water with its pressure, flow rate per hour) ; if any of the above is essential]
25Vendor to provide UPS with adequate capacity, if required for the quoted equipment. If not required, vendor to mention the same.Vendor to provide UPS with adequate capacity, if required for the quoted equipment. If not required, vendor to mention the same.
26Vendor to submit details of footprint size & weight of the quoted model.Vendor to submit details of footprint size & weight of the quoted model.
27Vendor to submit power consumption.Vendor to submit power consumption.
28Demo of the quoted model , will be required if so desired by the user, after the opening of the technical bid and prior to opening of financial bid. This is for technical evaluation. All technical specifications mentioned above to be mandatorily shown in the demo unit.Demo of the quoted model , will be required if so desired by the user, after the opening of the technical bid and prior to opening of financial bid. This is for technical evaluation. All technical specifications mentioned above to be mandatorily shown in the demo unit.
29User's/Installation list: A list of installations of the quoted model with the address and contact numbers to be provided.User's/Installation list: A list of installations of the quoted model with the address and contact numbers to be provided.
30Predispatch inspection at factory will be required if desired by authorities.Predispatch inspection at factory will be required if desired by authorities.
31Should be CE/US FDA/BIS/ICMED approved.( In the case of CE certificate, the vendor must submit the Declaration of Conformity)Should be CE/US FDA/BIS/ICMED approved.( In the case of CE certificate, the vendor must submit the Declaration of Conformity)
32Vendor should provide the User manual and service manual copy during the installation of the equipment.Vendor should provide the User manual and service manual copy during the installation of the equipment.
33Unpacking and shifting the consignment to the installation site is to be included in the vendor's scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installation site. Unloading site shall be Stores department, TATA MEMORIAL HOSPITAL,PAREL. If needed ,bidder has to arrange for the labours at no charge to TATA MEMORIAL HOSPITAL,PAREL.. (Before submitting the quotation,bidders may visit TATA MEMORIAL HOSPITAL,PAREL. to know unloading and installation site.Unpacking and shifting the consignment to the installation site is to be included in the vendor's scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installation site. Unloading site shall be Stores department, TATA MEMORIAL HOSPITAL,PAREL. If needed ,bidder has to arrange for the labours at no charge to TATA MEMORIAL HOSPITAL,PAREL.. (Before submitting the quotation,bidders may visit TATA MEMORIAL HOSPITAL,PAREL. to know unloading and installation site.
34Training:Training:
35Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted.Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted.
36Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email.Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email.
37Warranty- 2 yearsWarranty- 2 years
38CMC- cost per annum will be considered for all bidders for 8 years after warrantyCMC- cost per annum will be considered for all bidders for 8 years after warranty
39Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted.Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted.
40If 2 years warranty, CMC per annum for 8 years after warranty and Buyback if any wherever applicable are not adhered to, TMC reserves right to reject the offer.If 2 years warranty, CMC per annum for 8 years after warranty and Buyback if any wherever applicable are not adhered to, TMC reserves right to reject the offer.
41Please mention whether UPS is required for the equipment. If so should be included in the offer.Please mention whether UPS is required for the equipment. If so should be included in the offer.
42Only Yes or No should be mentioned in compliance report and additional information in remarks column.Only Yes or No should be mentioned in compliance report and additional information in remarks column.
43Please provide list of the Consumables/Spares/Reagents/Control/Calibrators (if any) in Technical Documents and cost of the same should be uploaded in PDF file in the Financial Documents.Please provide list of the Consumables/Spares/Reagents/Control/Calibrators (if any) in Technical Documents and cost of the same should be uploaded in PDF file in the Financial Documents.
44Do not mention / upload price and cost in the technical documents otherwise your quotation will be disqualified at technical stage.Do not mention / upload price and cost in the technical documents otherwise your quotation will be disqualified at technical stage.

AI Tender Summary

OUR REF NO 57382287
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 28-09-2026
Authority
Authority Name Tata Memorial Centre
Work Description Bids Are invited for Biosafety Cabinet - Biosafety Cabinet Should Be Of Class Ii, Type A2 With Approx. 30% Exhaust And 70% Recirculation Air-Flow Specifically Required For Use In Biological Applications , Cabinet Should Have Internal Dimension (Wxdxh) Approximately 3*2.5*7Ft. , Cabinet Height Should Not Exceed More Than 7 Feet. , Cabinet Construction: , Filters: , Should Have Microprocessor Controlled And Digital Display With Stable Airflow And Automatic Adjustment Of Blower Speed For Compensation Against Filter Choking, Filter Life Display, Blower Hour Meter ,Uv Hr Meter , Alarms Etc. On Lcd Display. , Should Be Noiseless Front Openging Of The Cabinet And It Should Be Angled So As To Help Minimize Glare On Window To The User. , Should Have Integrated Armrests That Are Raised Above The Work Surface To Help Prevent The Users Arms From Blocking The Front Air Inflow, Thereby Maintaining Proper Airflow And Containment. , Should Have Smooth (Noiseless) Sash Operation Manually With Gaskets All Around The Sash. , Should Have Uv Light For Decontamination With On/Off Timer. , Should Be Certified To Nsf 49 Or En12469 (Certification To Be Enclosed). , Ulpa Filters Should Be En-1822 Certified. , Cabinet Should Be Supplied With Support Floor-Stand With Locking Caster Wheels. , Should Have Built In 6A And 16A Electrical Socket. , Internal Fluorescent Lighting Fixture Should Be Such That Light Should Not Be Facing The User And It Should Be Out Of The Air Stream. , All Internal Wall Of Working Chamber Should Be Single Piece Ss 304 Including Side Wall With Rounded Corner. , Cabinet Should Produce Low Sound Less Than 60Dba , Virus Burn Out Unit With Ducting: , Vendor Shall Perform Validation Of Biosafety Cabinet Under Warranty And Cmc At Half Yearly Intervals As Per Nabl 112 Guidelines.It Includes Tests - Differential Pressure Test,Particle Count Test, Air Flow Velocity Test And Hepa Filter Integrity Test. All Validation Activities Shall Be Carried Out By Nabl-Accredited/Certified Laboratory And Vendor Shall Submit Nabl Accredited/Certified Test Reports And Traceability Certificate, Ensuring That The Nabl Logo Appears On Both The Main Test Certificate And The Traceability/Calibration Certificate. Same Validation Is Mandatory After Replacement Of The Filters. Faulty Filters To Be Taken Out Of Tmh Premised By The Vendor During Warranty And Cmc Period. , Should Perform Preventive Maintenance (2Nos) During Warranty,Amc,Cmc & If Entered Into Amc(Includes Unlimited Breakdown Calls) /Cmc (Which Will Include Spare Replacement, Breakdown Calls). Vendor To Submit Sops For Pms At The Time Of Installation/ Commissioning. This Is Mandatory Requirement. , Performance Certificates Of Iq,Oq,Pq Tests To Be Submitted At The Time Of Installation/Commissioning. , Vendor To Submit The Technical Data Sheet, Brochure Etc As A Tender Document With Reference To The Quoted Make & Model. Please Mention The Reference Page No., Etc In These Documents Against Each Technical Specifications In The Compliance. , Vendor To Submit List Of Consumables/Consumable Spares( I.E.Spares Need To Be Replaced At Regular Intervals, Maybe Quarterly/Half Yearly/Yearly Etc.) If Any.Cost Of Consumables To Be Given By The Vendor In Financial Bid. , Please Submit Pre Installation Requirements [Electrical, Hvac, Compressed Air Along With Air Pressure Mentioned), Water Requirement (Ro/Di/Distilled Water With Its Pressure, Flow Rate Per Hour) ; If Any Of The Above Is Essential] , Vendor To Provide Ups With Adequate Capacity, If Required For The Quoted Equipment. If Not Required, Vendor To Mention The Same. , Vendor To Submit Details Of Footprint Size & Weight Of The Quoted Model. , Vendor To Submit Power Consumption. , Demo Of The Quoted Model , Will Be Required If So Desired By The User, After The Opening Of The Technical Bid And Prior To Opening Of Financial Bid. This Is For Technical Evaluation. All Technical Specifications Mentioned Above To Be Mandatorily Shown In The Demo Unit. , Users/Installation List: A List Of Installations Of The Quoted Model With The Address And Contact Numbers To Be Provided. , Predispatch Inspection At Factory Will Be Required If Desired By Authorities. , Should Be Ce/Us Fda/Bis/Icmed Approved.( In The Case Of Ce Certificate, The Vendor Must Submit The Declaration Of Conformity) , Vendor Should Provide The User Manual And Service Manual Copy During The Installation Of The Equipment. , Unpacking And Shifting The Consignment To The Installation Site Is To Be Included In The Vendors Scope Of Supply. Bidder/Manufacturer/Authorized Service Provider Should Take Responsibility To Lift /Shift The Consignment From Unloading Site To The Installation Site. Unloading Site Shall Be Stores Department, Tata Memorial Hospital,Parel. If Needed ,Bidder Has To Arrange For The Labours At No Charge To Tata Memorial Hospital,Parel.. (Before Submitting The Quotation,Bidders May Visit Tata Memorial Hospital,Parel. To Know Unloading And Installation Site. , Training: , Local Service Support: Should Have Local Office And Service Support/Service Engineer For Attending The Breakdown Calls. Details To Be Submitted. , Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. , Warranty- 2 Years , Cmc- Cost Per Annum Will Be Considered For All Bidders For 8 Years After Warranty , Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. , If 2 Years Warranty, Cmc Per Annum For 8 Years After Warranty And Buyback If Any Wherever Applicable Are Not Adhered To, Tmc Reserves Right To Reject The Offer. , Please Mention Whether Ups Is Required For The Equipment. If So Should Be Included In The Offer. , Only Yes Or No Should Be Mentioned In Compliance Report And Additional Information In Remarks Column. , Please Provide List Of The Consumables/Spares/Reagents/Control/Calibrators (If Any) In Technical Documents And Cost Of The Same Should Be Uploaded In Pdf File In The Financial Documents. , Do Not Mention / Upload Price And Cost In The Technical Documents Otherwise Your Quotation Will Be Disqualified At Technical Stage.
Basic Detail
Tender No GEM/2026/B/8002975
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 07 Sep 2026
Submission Date 28 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 18480
Exemption Available
Document List
e687650d-116a-4c98-aef2-362d34717334.pdf
1788755753.xlsx
biosafety_cabinet_2026-09-07-09-59-36_379f23611d5b1390e602c5e24091183f.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
pdf

e687650d-116a-4c98-aef2-362d34717334.pdf

xlsx

1788755753.xlsx

xlsx

biosafety_cabinet_2026-09-07-09-59-36_379f23611d5b1390e602c5e24091183f.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders