Housing Urban and Rular Development Government Departments Closing in 8 days TDR #57381998

Tender For Construction Of Teaching Block Of College Building First Floor (Over Existing Building Of Gnm School), Buildings.

Issued by Government Departments · Kandhamal, Odisha
Tender Value
3.09 Crore
Estimated cost
Bid Submission
21 Sep 2026
8 days left
EMD
3.09 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kandhamal → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Teaching Block Of College Building First Floor (Over Existing Building Of Gnm School), Buildings.

BOQ

Name of Work:- Construction of Teaching Block of College Building First Floor (Over Existing Building of GNM School), Buildings.
Sl. No. Item Description
1CIVIL WORK:Dismantling brick or stone masonry in lime or cement mortar under 3m.height including stacking the useful materials for reuse and removing the debris within 50m. Lead including all cost, conveyances of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-chargeFirst Floor
2Dismentaling & removing R.C.C columns beams, slab, staircase, landing, lintels, including stacking the useful materials for the reuse and removing the debries within 50 mincluding all cost, conveyances of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-chargeFirst Floor
3Dismentaling & removing GCI or AC sheet roofing after carefully removing the bolts and nuts including stacking the useful materials for the reuse and removing the debries within 50 mincluding all cost, conveyances of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-chargeFirst Floor
4Removing old tarfelt from roof cleaning the surface lowering including stacking the useful materials for the reuse and removing the debries within 50 mincluding all cost, conveyances of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-chargeFirst Floor
5RCC M-20 using 12 mm. to 20 mm. (0.5 inch to ¾ inch) size (20 mm. not to exceed 25%) hard crusher broken granite stone aggregate of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with all cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge.ColumnFirst Floor
6Second Floor
7LintelFirst Floor
8Second Floor
9Beam First Floor
10Second Floor
11Roof SlabFirst Floor
12Second Floor
13ChajjaFirst Floor
14Second Floor
15Stair caseFirst Floor
16Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / TATA / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including all cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of the Engineer-in-charge.First Floor
17Second Floor
18Fly Ash brick masonry in cement mortar (1:6) in Foundation and plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance plus minus 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including all cost, conveyance, royalties with all labour,labour cess and T & P required for the work complete in all respect as per specification and direction of tne Engineer-in-Charge. First Floor
19Second Floor
20Providing 12mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with all cost, conveyance, royalties, with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect and specification and direction of the Engineer in charge. First Floor
21Second Floor
22Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with all cost, conveyance, royalties, with cost of all labour,labour cess, T&P and scaffolding required for the work etc. complete in all respect as per direction of the Engineer-in-charge .First Floor
23Second Floor
24Supplying, fitting & fixing of Vitrified colour/ printed series tiles of thickness 8mm to 10mm in floors of size 600mm x 600mm of approved make confirming to IS:13755 laid on 25 mm thick cement mortar (1:1) (1 cement : 1 course sand) and filling joints with white cement of approved quality including cost of all materials, labour, labour cess, T&P etc. required for the work all complete as per direction of the Engineer-in-charge .First Floor
25Supplying, fitting & fixing of Vitrified colour printed series tiles of thickness 8mm to 10mm in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 25 mm thick cement mortar (1:1) (1 cement : 1 course sand) jointed with slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete including cost of all materials, labour , labour cess, T&P etc. required for the work all complete as per the direction of the Engineer-in-charge. Ground Floor
26Supplying, fitting & fixing of Granite floor tiles (Above 0.1Sqm upto 0.4Sqm) of thickness 8mm to 10mm in floors of size 600mm x 600mm of approved make confirming to IS:13755 laid on 25 mm thick cement mortar (1:1) (1 cement : 1 course sand) and filling joints with white cement of approved quality including cost of all materials, labour, labour cess, T&P etc. required for the work all complete as per direction of the Engineer-in-charge. First Floor
27Providing fitting fixing of false ceiling with Aluminium anodised T section No.3215 with 2'0\\" center to center, L section No.1705 on 4 walls to be fixed by means of steel screw and P.V.C. plug and the Aluminium grid 2'0\\"x2'0\\" with 12mm thick Prelaminated Particle Board suspended from ceiling including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-chargeFirst Floor
28Supplying of M.S. Grills/shutter of approved quality and design to windows and openings and staircase railing and parapet railings etc including making holes in walls and RCC structures or wood work etc in proper position making good the damages of walls or RCC or other structures complete including bending or cutting sizes or grooves in chowkhats with all cost and conveyance of all materials labour , labour cess with T&P required for the work and royalities etc.complete (including screws) in all respect in all floors as per the direction of Engineer-in-Charge .First Floor
29Second Floor
30Supplying & fitting fixing of Un- plasticised Poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD) Casement Door-60 series dully manufactured using UPVC reinforced profile of 60mmx55mmx2.5mm for outer frames 102mmx60mmx2.25mm for cashment door sash profile and 74mmx60mmx2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 2.0mm prefabricated and welded through fusion welding the door sash shall be fixed with 12mm thick WPC board of Greenply make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 no. per set of sashes & the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing /deglazing at site etc. including cost and conveyance of all materials, accessories,labour charges, materials and product and product conforming to ASTM D 638-14 EN-477-95 and Other applicable codes and standards.First Floor
31Supplying & fitting fixing of Un- plasticised Poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD) Three Track -Three Panel sliding Window -60 series dully manufactured using UPVC reinforced profiles of 108mmx45mmx2.5mm for outer frames & Window sash of 39mmx58mmx2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm prefabricated and welded through fusion welding the window sash shall be fixed with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant & the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing /deglazing at site etc. including cost and conveyance of all materials, accessories,labour charges, materials and product and product conforming to ASTM D 638-14 EN-477-95 and Other applicable codes and standards.First Floor
32Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including sand papering, cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. First Floor
33Second Floor
34Wall painting two coats with plastic emulsion paint of approved make and shade over a coat of water bound wall cement primer of approved make on new work including sand papering, cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour, T&P etc. complete as per the direction of the Engineer-in-charge. First Floor
35Second Floor
36Wall Painting two coats with any approved colour of weather seal coat over a coat of Water Bound Wall cement Primer to out side surface of wall with approved shade and quality etc including sand papering, polishing the surface, all cost, conveyances of all materials and cost of all labour, labour cess with T&P etc, complete as per specification & direction of the Engineer-in-charge.Ground Floor
37First Floor
38Second Floor
39Painting two coats with approved Enamel Paint on Steel surface over a coat of Red Oxide Primer including all cost of primer and paint, sand papering, polishing the surface, all cost, conveyances of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge.First Floor
40Second Floor
41Supplying, fitting and fixing hand railing of Stainless steel of 304 grade using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with all cost, conveyance, taxes of all materials, cost of all labour, T&P etc. required for the complete in all respect as per direction of the Engineer-in-charge. Ground Floor
422.5 cm thick Grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips on new work including all cost, conveyances of all materials and cost of all labour with T&P etc, complete as per specification & direction of Engineer-in-charge. First Floor
43Second Floor
44Carriage of Dismantled items within 5KM lead Including all cost i.e cost of all materials, all labour, all T&P, royalty etc complete in all respect and as per direction of the Engineer- in- charge.
45Supplying fitting and fixing of rigid UPVC pipe 110mm dia PVC rain water pipe including cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge.First Floor
46PH WORKSSupplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.First Floor25mm dia C- PVC
4732mm dia C- PVC
4840mm dia C- PVC
4950mm dia C- PVC
50Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP angle stop cock(FLR-ACR-5053N)
5115mm dia CP two way bib cock(FLR-CHR-5041N)
5215mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
5315mm dia CP Bib cock (Con-CHR-047KN Jaquar make)
5425mm dia brass full way valve (Shakti make)
5532mm dia brass full way valve (Shakti make)
5640mm dia brass full way valve (Shakti make)
5750mm dia brass full way valve (Shakti make)
5815mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
5915mm CP Extension piece
60125mm CP grating
6115mm size C.P. flange
62Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank
63supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.First Floor
64Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-chargeFirst Floor
65Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.First Floor
66Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B)
67110mm U-PVC P Trap(Ori Plast/Finolex/Supreme Make)
68110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
69110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
70110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
71110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
72110mm U-PVC HR Bend(Ori Plast/Finolex/Supreme Make)
73110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)
74110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
75110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
76110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)
77110mm U-PVC Plain shoe bend(Ori Plast/Finolex/Supreme Make)
78110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
79Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
80Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-chargeEuropean water closet with 'p' trap plain(Hindware/Parryware / Neycer make)
81Supplying all materials,labour,T&P and fixing Flat back lipped wall (stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal
82Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.580mm size Orissa pan (Hindware/Parryware/Neycer make)
83Matrix set of Hindware
84Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-chargeCounter top basin basin(560x450)Hindware-No.10095
85550x400mm wH Basin with pedestall and pillar cock (Jaquar/ Hindware/ Parryware) 22 INCH x 16 INCH pedestal
86Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24 INCH x 18 INCH x 10 INCH sink
87Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge25mmx600mm long CP towel rail
88Towel ring
89Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails.
90Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.600mmx450mm size B.E mirror (swivelled type)
91Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeCP soap holder
92Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
93Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
94Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-chargeFirst Floor
95Supplying all materials, labour, T&P and providing and fixing Vetrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge )(Somany/Johnson/KajariaFirst Floor
96Supplying all materials, labour, T&P and providing and fixing Vetrified tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge )Somany/Johnson/KajariaFirst Floor
97GRANITE
98Supplying & fitting fixing of unplasticised Poly vinly chloride (UPVC ) (FENESTA/ NCL/ VEKA LTD) Casement Door series dully manufactured using UPVC reinforced profile of 60mmx55mmx2.5mm for outer frame 102mmx60mmx2.5mm 2.13*0.75*85
99Supplying all materials labour T&P and providing 1st class KB brick work in CM (1:3) in foundation and plinth including watering and curing and lead of materials to site.
100Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 120 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 120 liter's along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in chargeAqua guard pure Chill 120 PSS UV
101Ext. S/D Portion1 Nos. 50,000 ltr capacity R.C.C. Under ground sumpEarth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge.
102Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC.
103Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor.RCC floor, roof slab chhaja up to 4.430 m height
104Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges.
105Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete. 1 x 9.00m x 6.00m x .15m =
106Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site.
107Supplying all materials labour T&P and providing 12mm thick C.P (1:3) including watering curing and conveyance of all materials to site.
108Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site. In side
109Supplying all materials labour T&P filling sand in foundation and plinth with well watered and rammed etc. all complate. As per direction of ELC.
110Construction of 1nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore onlyDrilling of 200mm dia bore00 mtr to 30mtr
11130 mtr to 45mtr
112Drilling of 150mm dia bore45 mtr to 213
113Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.200mm dia PVC pipe00 mtr to 45 mtrs
114Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.200mm dia PVC (sch-80) pipe
115Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department)
116Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in chargeBy DTH Rig
117Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:Rocky terrain with boulder formation for 300m depth
118Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)2 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm
119DOL Control panel
12040mm dia steel short piece
121Well cap
12250mm size CI bracket
1232.50sqmm flat cable
124Steel rope with cover
125Labour charges for lowering including transportation
126Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge32mm HDPE pipes (Finolex/Supreme make)
127Rain Water HarvestingSupplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B)
128Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge150mm dia P.V.C. pipe
129Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
130Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-chargeInside size 76cmx76cmx46cm with 18 INCH dia RCC MH cover
131EI WORKSRecessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/ HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( anti-bactorial and flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-Next gen) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( anti-bactorial and flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-Next gen) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group- A
132Group-B.
133Group-C.
134Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti-bactorial and flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-Next gen) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
135Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti-bactorial and flame retradant type)) with suitable size modular box & cover( anti-bactorial and flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-Next gen) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
136Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( anti-bactorial and flame retradant type)) with suitable size modular box & cover( anti-bactorial and flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-Next gen)/Panasonic (vision) (For equipement power)(Make :Legrand(Myrius-Next gen)/-Schneider(Zencelo)/PANASONIC(VISION)
137Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( ( anti-bactorial and flame retradant type) with suitable size modular box & metallic cover plate (both side)( anti-bactorial and flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-Next gen)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
138Recessed wiring to submain in the following sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metalic heavy duty flexible conduit 1.6mm thick along with the following sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required. (Make of wire Finolex / KEI/ Polycab/ L&T/ Anchor)a) 2x1.5mm2 + 1x1.5mm2. in 20mm dia
139b) 2x2.5mm2 + 1x1.5mm2. in 20mm dia (for raw power)
140c) 2x2.5mm2 + 1x1.5mm2. in 20mm dia(for UPS power)
141d) 2x4mm2 + 1x1.5mm2 in 20mm dia
142e) 2x6mm2 + 1x2.5mm2 in 25 mm dia
143e) 4x10mm2 + 2x4mm2 in 32 mm dia
144Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.a) 2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years
145b) 12way double door SPN with 3 year warranty
146c) 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR Power DB)
147d) 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years
148Supply and fixing of 5amp to 32 amp rating 240V \\"C\\" series miniature circuit breaker suitable for lighting and other loads of the following poles in t he existing MCB DB ISI marked complete with connections testing and commissioning etc. as required. (Make- -LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200)a) 6Amp rating to 32Amp (SP) MCB
149b) 40 Amp (DP) MCB
150c) 40Amp (DP) RCCB 30 mA
151d) 63Amp (4P) MCB, 415 Volts, 10 KA breaking capacity
152e) 63Amp (4P) RCCB 30 mA, 415 Volts
153Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
154Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery GREATER THAN EQUAL TO 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator Compatible)
155S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius-Next gen)/Panasonic (vision)
156Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
157Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
158SITC of Sleek LED 10 watt mirror light fitting with decorative aluminium LED batten having extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)
159S/F. of 1x18Wt. LED tube light fiting (Philips / Panasonic / Havels) make.
160S/F of Bakelite angle holder/ batten holder (Make Anchor/ Cona).
161S/F. of 9 Wt. LED bulb (Philips / Panasonic / Havels) make.
162Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.
163Supplying an fixing of recess/surface mounted 2'x2'(595mmx595mmx70mm(+/-5%) square shaped LED made up of CRCA powder coated housing with lumen efficacy not less than 140lm/W and lumen output not less than 3600 lumens , CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 -50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/ LT/ Havells / Philips/ Wipro/ Crompton/ Bajaj) .
164Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge.
165S/F. of Inverter, UPS 2250VA (Make Microtech/Su-kam/Luminous)
166S/F of Inverter Battery 12V 150AH (Make Exide / Amrom / Su-karm / Luminous with 48 Month warranty).
167S/F. of Inverter Stand (Make Microtech/ Su-kam/ Luminous)
168Supply,installation, testing and commissioning of Air Cooled HI Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), i/c R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and50 hz ,1 phase AC Supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll /rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS694 or IS 9968 temperature sensing control IS/ International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS :1391 Part II 2023. The system shall be able to operate up to 50 Degree C (out door ambient temperature). The indoor outdoor must be Blue Fin coated. The unit price included with 3mtr Copper piping with insulation, drain Pipe and copper Power cable. The indoor should have 4 way swing . 1.5 TR with 5 Star BEE Rating (LG-AS-Q20JWZE/ O General-ASGG18CGWA-B/ Daikin-FTKU50XV16)
169REFRIGRANT PIPINGSupply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C
170FRAME WORKSupply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C
171DRAIN PIPINGSupply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.25mm nom. Dia pipe
172Supply and fixing of 4kVA Voltage stabilizer (Make-V-Guard/Microtek
173Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required
174Supplying and laying 8SWG copper wires ISI marked at 0.5meter bellow ground level for conductor earth electrode including soldering etc as required.
175Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mm x 600mm x 6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
176Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 95 sq mm ( FOR FDB 1F,2F, POWER )
177Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
178Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.3.5 core x95 sq mm
179FLOOR POWER PANEL(3F)SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF INDOOR PANNEL BOARD WITH DANGER BOARD. (S/F OF 250A. PANNEL BOARD 48\\"x42\\"x12\\") ( 1St Floor)a) 16/18 SWG PANNEL BOX 48\\"x42\\"x5\\"= sq.inch for single door made out of CR sheet of 16SWG and boarder angle frame to provide above pannel with proper space, hinges and other accessories, hinged door must be painted one coated red oxide and two coat enamel gray paint 10080sq.inch @1.51.b) Supply and fixing of internal wiring to equipment installed in the pannel board with required size of copper multistrand sinlge core cables duly crimped with copper lugs and all connections 48\\" x 42\\" including cost of copper conductor and other fittings like gasket, screw, nut and bolt, insulating materials etc. 2016sq. inch@ 0.87.c) S/F of Bus bar (35x5)mm with required size of insulating materials nut & bolts.10mtr@722 for 2 Nos. of 4Pole Bus bars. (Power + light)d) S/F of 250AMP. 4P 50kA MCCB of L&T / Siemens / Legrand / Hager make.1no@27,188.e) S/F of DN4 Extended Rotary [email protected]) S/F of Spreader Terminal - 4Pole. [email protected]) S/F of Ammeter with selector switch including all connections.1no.@1,398h) S/F of Voltmeter with selector switch including all connections.1no.@1,398i) S/F of indicator lamp with toggler switch and fuse. 3nos.@242j) S/F of CT coil upto 400AMP. Including all connectios. 1set@860k) S/F of 63A. 4P MCB make L&T / Siemens / Legrand / Hager/ Schneider make 5nos.@2,966l) S/F of 40A. DP MCB make L&T / Siemens / Legrand / Hager/ Schneider make 6nos.@1,525.
180Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire//Flameklog.6 kg capacity
181Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire/Flameklog .4.5 kg capacity Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57381998
AUTHORITY Government Departments
TENDER VALUE 3.09 Crore
LAST DATE 21-09-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Construction Of Teaching Block Of College Building First Floor (Over Existing Building Of Gnm School), Buildings.
Basic Detail
Tender No CCE-R-AND-B-PLB-04 OF 2026-27
Bidding Type Tender
Location
City Kandhamal
State Odisha
Key Dates
Publish Date 07 Sep 2026
Submission Date 21 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 3.09 Crore
Tender Fee 10000
EMD 3.09 Lakhs
Exemption Available
Document List
4d71f558-48b0-4807-8932-e6c67ec53e72.html
BOQ_608559.xls
Tendernotice_1 (19).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

4d71f558-48b0-4807-8932-e6c67ec53e72.html

xls

BOQ_608559.xls

pdf

Tendernotice_1 (19).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender