Communications and Information Technology Government Departments Closing in 3 days TDR #57381784

Tender For Providing electrical installation & Sub-Meter, Tower Earthing & La, Free Cooling Unit , Afd & Alarm System For Bts Site At Ichhapore Metal & Steel Factory Under Phase-Ix.2, Ctd, Kolkata.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
2.44 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
3 days left
EMD
4883
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Providing electrical installation & Sub-Meter, Tower Earthing & La, Free Cooling Unit , Afd & Alarm System For Bts Site At Ichhapore Metal & Steel Factory Under Phase-Ix.2, Ctd, Kolkata.

BOQ

Name of Work:- Providing EI & Sub-meter, Tower earthing & LA, Free Cooling unit , AFD & Alarm system for BTS site at Ichhapore Metal & Steel Factory under Phase-IX.2, CTD, Kolkata.
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(Group C)
2Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
3a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4b )2 X 4 sq. mm + 1 X 4 sq. mm earth wire
5Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
6a) 3 x 1.5 sq. mm
7b) 4 x 1.5 sq. mm
8Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
9Supplying and fixing PVC batten/ angle holder including connections etc. as required.
10Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
11Supplying and fixing 5/6 amps piano type socket on the existing switch box/ cover including connections etc. as required.
12Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)a) 4 way (4 + 12), Double door
13Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63 amps
14Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
15a) Single pole
16b) Triple pole
17Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
18Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ X 25 sq. mm (28mm)
19Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
20Supplying and fixing of 4'x20Watt LED tube light batten fitting (Philips or ss make) etc as required.
21Supplying and fixing of 9Watt LED lamp (Philips or ss make) etc as required.
22S/F of 3.5 X 25 sqmm. PVC insulated and PVC sheathed armoured aluminium conductor cable of 1.1 KV grade on surface with proper saddling complete with connections, testing etc as reqd.( BSNL approved make)
23Supplying and fixing (10-40) 3 phase 4 wire kWh digital meter 240 V, (Cat No - WR301BC6D20 of M/s L&T or S/S make) with suitable size bakelite hard board sheet 5mm thick i/c Supplying& fixing 3nos 63 A kitkat fuse unit etc. complete as required.
24Supplying fixing of 4x10sqmm PVC insulated copper condr. flexible cable for power plant interconnection with flexible PVC pipe Cu. lug socketing etc. complete as required.
25Supplying fixing of 2x6sqmm PVC insulated copper condr. flexible cable for necessary interconnection with flexible PVC pipe, Cu. lug socketing etc. complete as required.
26Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.( Note: Two for Electrical Installation)
27Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
28Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.( Note: Two for body of tower, Two for LA)
29Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
30Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
31Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
32Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.l. tube, having single prong at top, with 85 mm dia 6 mm thick G.l. base plate including holes etc. complete as required.
33Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
34Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
35Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
36Providing and fixing earth bus of 32 mm X 5 mm & 350mm long GI strip on surface for connections i/c two nos porlelian supporter making holes with nut bolts etc. as required.
37Making opening suitable for installation of 1 no. 300 mm sweep Axial flow fan i/c cutting, grouting of bolts, making good the damages, complete as reqd. (NBSNL BTS room / Shelter as per site requirement)
38Supplying installation, testing and commissioning of 1 no. heavy duty axial flow type fan 300 mm sweep , 1350/1400 RPM suitable for single phase 220 V AC supply including clamps, fixing bolts, sundry materials, complete as reqd. (Make Trumax or Similar Superior make)
39Supplying, installation, testing and commissioning the louvers / shutters complete for rain protection suitable for above axial flow fan as required.
40Supplying/Fixing M.S collar including fabrication with 16 swg M.S sheet including gasket and putty including painting for rain protection and provision of fixing louvers / shutters.
41Supplying, Installation, testing and commissioning Timer / Time switch (AUTS02DIG00 of L& K or similar superior make) on surface fixed on a suitable size of PVC / MS box with cover for alternative operation of above axial flow fan complete as reqd.
42Supplying and laying of 3 x 1.5 Sq. mm PVC insulated copper conductor cable in PVC casing & capping / PVC conduit for connection of Axial flow fan and timer as required.
43Making fresh air inlet arrangement complete with following a) Making opening 450mm x 350mm and making good the damages for air filter assembly b) S/F 16 SWG perforated GI/MS sheet with painting on outer surface of wall including arrangement for preventing rain water and wire mesh with suitable frame on inner surface complete with painting as reqd. c) S/F aluminium channel framing on inside surface of wall for drawing out air filter for time to time cleaning/washing d) S/F synthetic washable type air filter to prevent dust particle and insect.
44SITC of 2(Two) Zone Microprocessor based fire alarm local control panel fabricated from MS sheet having knock outs, confirms to IS:2189-1988 comprising of a power supply module with battery charging circuit,indicator module to display to power supply status, one control module & zone modules incorporating self test facility for individual zones, a common fire flushing annunciation, three distinct tones through built-in-speaker,external hooters/sounder outputs, potential free fire relay contacts, unambiguous fire/fault indicators with test lamp facility & silence to acknowledge the fire alarm suitable for wall/floor mounting etc complete as required. (Make : BSNL approved make) (Note:Without battery)
45SITC of Photoelectric / Optical smoke detector complete with testing , checking commissioning etc complete as required. (Make : M/s Agni, Apollo or similer superior make)
46SITC of 12V, 7.5 AH Sealed maintenance free battery for the above AFD & FA panel. (Make : Exide or Similer superior approved make)
47SITC of Electronic Hooter cum Speaker with range of 23 to 30 watt out put etc complete as required. (Make : BSNL Approved Make)
48SITC of mannual call point suitable for operation on 24 Volts DC supply i/c connection testing and commission etc. complete as required. (Make : BSNL Approved Make).
49Supplying and laying of following size Cu. Cond. Armoured cable complete with suitable saddle etc as required. (Make : ISI Marked)
50a) 2 x 1.5 sq.mm
51Supplying and making of following size end termination with steel compression gland suitable for PVC shed copper cond. Ar. cable i/c connections, testing, checking, etc. complete as required.
52a) 16mm
53Supply & fixing of 3Kg Co2 type fire extinguisher on wall etc complete as required.
54Fixing of BTS alarm panel (Alarm Penel will be provided by BSNL NWP/CM,CTD) etc. complete as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57381784
AUTHORITY Government Departments
TENDER VALUE 2.44 Lakhs
LAST DATE 17-09-2026
Authority
Authority Name Bharat Sanchar Nigam Limited
Work Description Tender for Providing electrical installation & Sub-Meter, Tower Earthing & La, Free Cooling Unit , Afd & Alarm System For Bts Site At Ichhapore Metal & Steel Factory Under Phase-Ix.2, Ctd, Kolkata.
Basic Detail
Tender No 79/BSNL/ED-III/Kol/NIT/2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 07 Sep 2026
Submission Date 17 Sep 2026
Open Date 07 Sep 2026
Finance
Tender Value 2.44 Lakhs
Tender Fee 590
EMD 4883
Exemption Available
Document List
79NITIchhapurBTS.pdf
BOQ_338291.xls
f54d7bb4-1e65-48a2-817e-5b2c91868834.html
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

79NITIchhapurBTS.pdf

xls

BOQ_338291.xls

html

f54d7bb4-1e65-48a2-817e-5b2c91868834.html

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders