Tender For Special Rep To Bldg No Sm-22(Single Men Barrack) At Fatehgunj, Eme School,Vadodara.

Issued by Statutory Bodies & Commissions/Committees · Vadodara, Gujarat
Tender Value
40.98 Lakhs
Estimated cost
Bid Submission
26 Sep 2026
12 days left
EMD
81960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vadodara → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Rep To Bldg No Sm-22(Single Men Barrack) At Fatehgunj, Eme School,Vadodara.

BOQ

Name of Work:- SPECIAL REP TO BLDG NO SM-22(SINGLE MEN BARRACK) AT FATEHGUNJ, EME SCHOOL,VADODARA.
Sl. No. Item Description
1Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete.
2Dismantling of framed timber scantlings 40 sq. cm and over in section, in any position
3Dismantling of un framed timber scantlings 40 sq. cm and over in section, in any position
4Demolition of wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets,all as specified.
5Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5sqm each
6Taking down chowkat or frames with shutters (without taking off shutters from the frames)exceeding 1.5 Sqm and not exceeding 4 Sqm each complete all as specified.
7Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar.
8M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws incl ridge all as specified and directed .
9M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in ridge of roof covering/ cladding to wall, fixed with self tapping screws incl ridge all as specified and directed .
10S&F structural steel work as in roof trusses, purlins, rafter, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-290-W (Gde-E-165) quality B complete all as specified.
11M&L for anodised aluminium snap grid frame work of size of grid 605 x 605mm for false ceiling all as specified Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid, complete all as specififed and directed.
12M & L for 25 mm thick cement concrete in flooring type B0, 1:2:4 (12.5mm graded aggregate) with liquid water proofing compound as per manufacturers instructions for laying floor tiles.
13M&L for 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
14M&L for 20-25 mm thick machine cut kota stone slab as in skirting or certical surface jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10mm thick back coat in cement and sand mortar 1:3 complete all as specified and as directed by Engineer-in-Charge.
15M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completet complete all as specified and directed.
16M & L Cement concrete type B1, 1:2:4 (20 mm graded aggregate) as in coping, bed plate for hold fast etc.
17M&L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved by EIC/GE.
18S & F 35mm thick 2nd class Hard wood Glazed and Skelton shutters, open rebated and prepared to receive glass, gauze etc(without sash bars) edges of framing plain, chamfered or rounded, fitted with cut ,mitered and moulded beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.
19S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as per TD and as directed by Egnr-in-Charge.
20Providing and fixing 4 mm thick solar reflective glass of approved make and shade in existing/new steel, aluminium or uPVC window frames, including cutting to required size, removal of damaged glass where necessary, fixing with glazing clips, approved quality rubber/EPDM gaskets, glazing beads, sealant and all necessary fixtures and fittings, complete in all respects. The glass shall be capable of reducing solar heat gain and glare while maintaining adequate visible light transmission, all as specified and directed by the Engr-in-Charge.
21S& F Galvanized mild steel wire-cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
22M&L for preparation of steel surfaces of any description exc 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
23S&F mild steel cold rolled butt hinges medium weight 100 mm long complete all as specified.
24S&F 200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed by Engineer-in-Charge.
25S&F aluminium handles cast type anodised of size 200mm long ISI marked complete all as specified and as directed by Engineer-in-Charge.
26S & F 250 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters
27Demolition of brick work or stone masonry built in cement mortar including all quoines arches,pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, all as specified .
28M & L for Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6, complete all as specified and directed complete all as specified and directed.
29Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified.
30M & L for rendering in two layer on fair faces of brick work or concrete surfaces of wall 5 mm thick in CM 1:4 mixed with WPC as per manufacturer's instructions of cement for fair finished over 10 mm thick rendering in cement mortar 1:6 complete all as specified and directed.
31M&L for rendering 10 mm thick cement plaster on brick/concrete surfaces etc in cement mortar 1:4 and finished even and smooth without using extra cement all as specified and directed.
32Supply Only integeral water proofing compound.
33Supplying and fixing galvanized iron chicken wire mesh of approved quality, 20 gauge (approx. 0.9 mm), with mesh size not exceeding 25 mm x 25 mm, securely fixed with nails, screws, or staples over the existing cracks and extending a minimum of 75 mm on either side of the crack all as specified and directed.
34M&L for complete removal of existing treatment by griding/washing or rubbing and applying one coats of clearcolle and applying two coats of oil bound distemper over a coat of 1mm thick wall care water proof putty on wall complete all as specified and as directed.
35M & L preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over one coat of primer over a coat of 1 mm thick water proof wall care putty, complete, all as speicfied and directed.
36M&L for complete removal of all existing treatment and preparing surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer - in - Charge
37M&L for preparation of new plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer - in – Charge
38Demolition of cement concrete (unreinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level) complete all as specified.
39M&L for providing 75mm thick PCC 1:3 :6 type C-2 using 40mm graded crushed stone aggragate as in plinth protection all as specified.
40M&L for anti-termite treatment by treating the soil under plinth protection at the rate of 5 liters of emulsion per square metre of surface area complete all as specified and directed by the Engr-in-Charge.
41Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for fair finished surface complete all as specified and directed by Eng-In-Charge
42M&L for Reinforced cement concrete (nominal mix) Type B1 (1:2:4) with 20mm graded stone aggregate as in beams all as specified and directed by Eng-In-Charge
43Supply and fix TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.
44Supply and fix TMT bars 6 to 8 mm dia, as in stirrups cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.
45Taking down carefully copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switches, sockets, c/roses, lamp holders, tube light fittings, sketch fittings, wooden boards, bell push, call bell, MCBs, & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall/floor etc.
46M&L for concealed point wiring with 1.5 Sqmm PVC-FRLS insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes made out of Pre-galvanized iron (GI) or cold-rolled closed-annealed (CRCA) mild steel with powder-coated or zinc-plated finishes for corrosion resistance , thickness ranges from 1.0 mm (20 Gauge) to 1.2 mm for structural rigidity ,Depth of box is between 45 mm and 60 mm to accommodate bulky wiring and modular mechanism frames... & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete incl cutting and chasing in stone/brick masonry all as specified and directed by Engr-in-charge .
47For one light point controlled by one switch
48For one fan point controlled by one switch
49For one 5 Amp independent socket point controlled by one switch
50For one 3 pin ,5 Amp socket point with other switch on the same board
51All as per item No 46 here in before but for power point wiring using with 2.5 sqmm PVC-FR LS insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by engir in charge.
52S&F Modular switch, one way, 6 Amp 230, 1 module all as specified and directed by Engr in charge.
53S&F socket Modular 6 Amp-2/3 pin combined 2 module all as specified and directed by Engr in charge.
54S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt all as specified and directed by Engr in charge.
55S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt . all as specified and directed by Engr in charge.
56S&F ceiling rose, surface backlit,three terminal. all as specified and directed by Engr in charge.
57S & F of BLDC White colour ceiling fan complete with blades electronic regulator(One Module) , down rod and accesories from existing roof / trus to fall ceiling, and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE,Winding material 100 % copper ,350RPM air velocity 215m3/min,anti rust blades five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.2). 02 years guarantee to be provided by the contractor.
58Supply and fixing LED batten lights fitting made of Aluminium extrusion 1x 20W (4 feet) , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 , connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr -in -charge. Including Taking down old Tublight fittingsNote :-Warrenty on light should be of minimum 02 Years provided by the contractor.
59S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 12 way 240 V with 200 amps rated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed
60S & F MCB single pole, having rupturing 10KA, 6 amps to 32 amps as ordered 240 Volts
61S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 63 amps as ordered.
62M&L concealed sub main wiring with two single core PVC FRLS insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC conduit not less than 25mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as directed by Engineer-in-Charge Note : One length of PVC Conduit and 3 run of cable shall be measured and paid as one length.
63Supply & Fix Inverter building security light of 35 Watt LED Street Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device ,lumens should be ≥ 120 lm/w ,OEM driver,PF 0.9,CCT 5700K including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers complete complete all as specified and directedNote :- The warranty on light should be of minnimum 2 Years provided by the contractor.
64Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.5 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron medium grade pipe 40mm bore in wall/floor/and GI Pipe 20 mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).Notes (a) The unit rate shall include for GI protection pipe, GI watering pipe, wire mesh, funnel and excavation, RCC pit cover, test point, galvanised iron strip from top of earth plate upto 7.5 metres above ground level and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(c) If the testing result of earthing is not found below 3 Ω then the contractor shall do another earthing work at his own cost and nothing shall be permissible on this account.(d) Earthing work will be carried out in presence of MES representative. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57380257
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40.98 Lakhs
LAST DATE 26-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Rep To Bldg No Sm-22(Single Men Barrack) At Fatehgunj, Eme School,Vadodara.
Basic Detail
Tender No 8132
Bidding Type Tender
Location
City Vadodara
State Gujarat
Key Dates
Publish Date 07 Sep 2026
Submission Date 26 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 40.98 Lakhs
Tender Fee 500
EMD 81960
Exemption Available
Document List
7b0ae7ff-060c-4ca6-8fe5-2e034ce4cc32.html
BOQ_883352.xls
Tendernotice_1 (9).pdf
Tenderpages8132.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

7b0ae7ff-060c-4ca6-8fe5-2e034ce4cc32.html

xls

BOQ_883352.xls

pdf

Tendernotice_1 (9).pdf

pdf

Tenderpages8132.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders