Defence Government Departments Closing in 0 days TDR #57380232

Tender For Replacement Of Existing Cfl Lights With Led Lights Installed At 120 Men Barrack, Sos Mess And Officers Institute Of Shq Bsf Bhopal.

Issued by Government Departments · Bhopal, Madhya Pradesh
Tender Value
2.83 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
0 days left
EMD
5674
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Existing Cfl Lights With Led Lights Installed At 120 Men Barrack, Sos Mess And Officers Institute Of Shq Bsf Bhopal.

BOQ

Name of Work:- Replacement of existing CFL lights with LED lights installed at 120 Men Barrack, SOs Mess and Officers Institute of SHQ BSF Bhopal.
Sl. No. Item Description
1Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim.
212-15 W
3Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm).
418-22 Watt
5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
65/6 A switch
715/16 A switch
83 pin 5/6 A socket outlet
96 pin 15/16 A socket outlet
10Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
11Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
123 Module
13Supply, installation, testing and commissioning of 10W surface/Wall mounted LED luminaire with IP20 ingress protection & the luminaire shall be with system efficacy≥100 lm/W. The luminaire is pre-wired with high efficiency electronic driver.The luminaire Housing shall be made of Aluminium Extruded with powder coated in white color. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000Hrs (Complete LM80 test report for LED should be submitted). The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 6500 K and CRI of Minimum 80. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V, THD≤20% & PF≥0.95. The LED Driver shall be easily avaiable in India for repair and service. Luminaire shall have minimum surge protection of 2KV and LM79 Test Report from NABL accredited Lab to be submitted to confirm above parameters, including connection with1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
14Supply, installation, testing and commissioning of 10W BULK HEAD LED LIGHT resistance of IK08 and ability to withstand harsh environmental conditions with IP65 protection With 120 Lm/W efficacy & 4kV inbuilt surge protection, LM79 Test Report from NABL accredited Lab to be submitted to confirm above parameters, including connection with1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
15Providing and fixing 18 W LED PL-L retrofit lamp having 2G11 (4-pin) base, cool daylight 6500 K CCT, minimum 1700 lumens output, system efficacy not less than 95 lm/W, complete with inbuilt electronic driver, suitable for operation on 220–240 V, 50 Hz AC supply, compatible for direct replacement of existing 36 W PL-L fluorescent lamp in the existing luminaire without any modification, with all necessary connections, testing and commissioning, complete as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57380232
AUTHORITY Government Departments
TENDER VALUE 2.83 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Border Security Force
Work Description Tender for Replacement Of Existing Cfl Lights With Led Lights Installed At 120 Men Barrack, Sos Mess And Officers Institute Of Shq Bsf Bhopal.
Basic Detail
Tender No 05/SHQ-BPL/MW/BSF/2026-27
Bidding Type Tender
Location
City Bhopal
State Madhya Pradesh
Key Dates
Publish Date 07 Sep 2026
Submission Date 15 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 2.83 Lakhs
Tender Fee Ref. Documents
EMD 5674
Exemption Not Available
Document List
a80220e9-eb1d-468e-a5af-f349c7a37fad.html
BOQ_972129.xls
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

a80220e9-eb1d-468e-a5af-f349c7a37fad.html

xls

BOQ_972129.xls

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders