Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #57379069

Tender For Construction Of Specialized Seed Storage Unit Alongwith Associated Sanitary Fittings & Internal Electrification Under Nmeo-Oil Seeds At Main C Us, Chatha.(Group No. 1)

Issued by Boards / Undertakings / PSU · Jammu, Jammu and Kashmir
Tender Value
54.40 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
0 days left
EMD
1.08 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Specialized Seed Storage Unit Alongwith Associated Sanitary Fittings & Internal Electrification Under Nmeo-Oil Seeds At Main C Us, Chatha.(Group No. 1)

BOQ

Name of Work:- Construction of specialized Seed Storage Unit alongwith associated sanitary fittings & internal electrification under NMEO-oil seeds at Main C us, Chatha.(Group No. 1)
Sl. No. Item Description
1Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses,string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with.
21:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
31:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
4Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
51:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
6Centering and shuttering including strutting, propping etc. and removal of form for :
7Suspended floors, roofs, landings, balconies and access platform.
8Lintels, beams, plinth beams, girders, bressumers and cantilevers.
9Shelves (Cast in situ)
10Edges of slabs and breaks in floors and walls.
11Under 20 cm wide
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
13Cold twisted/TMT bars
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (at all levels) in all shapes and sizes in:
15Cement mortar 1: 6 (1 cement: 6 coarse sand)
16Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
17200x10 mm
18Providing and fixing aluminium D handles ISI marked (powder coated) with necessary screws etc. complete :
19200 mm
20Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
21Providing and fixing aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete
22Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete
23Size of tile 600x600 mm
24Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.
25Size of tile 600x600 mm
26Providing gola 75x75mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3(1 cement : 3 fine sand) as per standard design
27In 75x75mm deep chase
28Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement :3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
2912 mm cement plaster of mix : (Inside)
301:6 (1 cement: 6 fine sand)
3115 mm cement plaster on the rough side of single or half brick wall of mix :
321:6 (1 cement: 6 fine sand)
336 mm cement plaster of mix :
341:3 (1 cement: 3 fine sand)
35Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
36Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
37New work (two or more coats) over and including water thinnable priming coat with cement primer.
38Finishing walls with Acrylic exterior paint of required shade : :
39New work (Two or more coat and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
40Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projection.
41Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
42For fixed portion
43Powder coated aluminium (minimum thickness of powder coating 50 micron)
44For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
45Powder coated aluminium (minimum thickness of powder coating 50 micron)
46Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .
47Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)
48With float glass panes of 5.0 mm thickness
49Providing and fixing wire gauge in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the Architectural drawings and the directions of the Engineer in charge. (Cost of aluminium snap beading shall be paid in basic item)
50Providing and fixing Anodized aluminum grill (Anodized transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as epr requirement and direction of Engineer-in-charge. (only weight of grill to be measured for payment)
51Providing and fixing aluminium lock handles for aluminium sliding shutters.
52Providing and fixing 100 mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
53Providing and fixing 6 amps to 32 amps rating 240 volts, 'L' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqired (category B)
54Single Pole
55Triple Pole and neutral
56Triple Pole
57Supply and fixing of following rating, 2P 230 volts, SPN in the existing MCB DB complete with connections, testing and commissiong etc. as required
5840 amps SPN
5963 amps SPN
6040 amps TPN
6163 amps TPN
62Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) complete as required for earthing and lightning protection.
63Providing and fixing 25 mm x 5mm GI strip from earth electrode as required
64Supply, installation, testing at works, installation and commissioning of following distribution boards totally enclosed compartmentalized, cubicle indoor type fabricated with 16 SWG sheet steel, with Aluminium bus bars (both for main and neutral bus bars), complete with following switchgear/ mountings cable terminations, inter-connections as required, for 415 volts, 3 phase, 4 wire 50 HZ AC supply as per specifications and drawings.
65Moulded case circuit Breakers shall be thermal magnetic trip type. Fault level for all MCCB and bus bar shall be 35 KA. ICU shall be equal to ICS=100%
66Note :
67All metering current transformers shall be Class 1, 15 VA.
68MDB-1 (Outdoor Type)
69Incomer (Power panel)
70125 A 4P MCCB – 1No.
71R,Y,B phase indicating lights with control fuses - 1 set
72Bus Bar
73160 A 415V, 50Hz, 3ph, 4 wire Aluminium Bus bar
74Outgoing
7540 Amp TPN - 1 No.
7663 Amp TPN - 1 No.
7740 Amp SPN - 2 No.
7863 Amp SPN - 2 No.
79Supply and laying of PVC Power cable 1.1 KV Grade armoured aluminium XLPE cables including earth work, cost of end termination, thimbles and saddles etc. as required.
803.5C x 50 sq.mm
81Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required.
828way TPN
8312 way SPN
84Supply and fixing 1x20 watt box type fitting complete with extruded alulminium tube rod including connection testing etc. as reqd. (CAT No. DMLNLT8-16 and LTT8-20)
85Supply and fixing of 18 Watt LED Panel surface mounted including connection testing etc as reqd. (CAT No. LCDSPLN-R-18-CDL)
86Supply and fixing of 9 Watt LED mirror light 2' long including connection testing etc as reqd. (CAT No. LCTL-09-CDL)
87Supply and fixing of 70 watt LED street light with G.I. pipe bracket with all accessories including connection testing etc as reqd.
88Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FR PVC insulated copper conductor cable in surface / recessed ISI marked PVC conduit with modular switch, modulr plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required.
89Light point on board with copper wiring in ISI marked PVC conduit wiring for 3 Pin 6 amp plug point with 1.5sqmm PVC insulated multistrand copper conductor cable including P/F of 3 Pin 6 amp modular switch socket outlet on switch board in surfaced recessed PVC conduit wiring system and 6 amp switch, earth the 3 pin as required with 01 No. PVIC insulated green colour wire.
90Wiring for light plug with 2 x 2.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x 2.5 mm copper wire for loop earthing required
91Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x4.0 Sq mm copper wire for loop earthing as required
92Wiring for power plug with 2 x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x1.5 Sq mm copper wire for loop earthing as required
93Wiring for 1x 1.5sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked in the existing PVC conduit etc. as required ( Invertor wiring )
94Wiring for sub main wiring with following sizes of PVC/ insulated copper conductor wires in the surface/ recessed PVC / MS conduit along with PVC insulated copper conductor earth wire as required complete with connections, testing and commissioning etc. as per specifications and drawings.
952x6 sq mm with 1x6.0 sqmm earth wire
96Wiring for sub main wiring with4x6 sqmm alongwith 2x6sqmm earth wire sizes of PVC/ insulated copper conductor side core conductor in surface/recessed PVC conduit etc. as reqd.
97Supplying and fixing of suitable G.I. box with modular plate and cover in the front on surface or in recessed, including providing & fixing 6 pin 15 Amp modular switch socket including connection testing etc as reqd.
98Supply and fixing of two module stepped type up electronic fan regulator on the existing modular plate switch box including connecting testing etc. as required.
99Supply and fixing of exhaust fan 300mm sweep heavy duty trans air with double ball bearing including connection, testing etc. as required.
100Supply and fixing Call bell / buzzer DC / AC single phase 230 V complete
101Supply and fixing 20 Amp Industrial socket with 32 Amp SPN including connection, testing, etc. as required
102Supply and fixing of 25 mm dia PVC conduit alongwith accessories in surface/recess.
103Supply and fixing of 32 mm dia PVC conduit alongwith accessories in surface/recess.
104Supply and fixing of 1200 mm sweep ceiling fan BLDC star rating inlcuding connection testing etc as reqd.(Cromptonn, Havells,atomburg) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57379069
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 54.40 Lakhs
LAST DATE 14-09-2026
Authority
Authority Name Sher-E-Kashmir University Of Agricultural Sciences & Technology
Work Description Tender for Construction Of Specialized Seed Storage Unit Alongwith Associated Sanitary Fittings & Internal Electrification Under Nmeo-Oil Seeds At Main C Us, Chatha.(Group No. 1)
Basic Detail
Tender No AU/Estates/2026-27/10 dated 21-08-2026
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 07 Sep 2026
Submission Date 14 Sep 2026
Open Date 15 Sep 2026
Finance
Tender Value 54.40 Lakhs
Tender Fee 2000
EMD 1.08 Lakhs
Exemption Not Available
Document List
35a0912f-bee8-42bc-82a4-105247246ac8.html
BOQ_1090278.xls
Tendernotice_1 (19).pdf
TermsandConditionsoftheContract.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Sep 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

35a0912f-bee8-42bc-82a4-105247246ac8.html

xls

BOQ_1090278.xls

pdf

Tendernotice_1 (19).pdf

pdf

TermsandConditionsoftheContract.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders