Tender For Supply Installation Testing and Commissioning of Video Conferencing System And Skva Ups System Including Electric Fitting Works At Generation Circle-Ii Srinagar., Jkpdc, J&K U.T
Tender Value
4.26 Lakhs
Estimated cost
Bid Submission
28 Sep 2026
17 days left
EMD
8500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganderbal → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of Video Conferencing System And Skva Ups System Including Electric Fitting Works At Generation Circle-Ii Srinagar., Jkpdc, J&K U.T
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. (Group B) |
| 2 | Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Supplying and fixing of modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 4 | Supplying and fixing following size/ modules, GI boxalong with modular base & cover plate for modularSwitches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 5 | Supplying and fixing of 3 Module (100mmX75mm) |
| 6 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling. |
| 7 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (Bell Push) |
| 8 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 9 | Supplying and fixing of metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
| 10 | Installation, Testing and Commissioning of existing ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. |
| 11 | Installation, Testing and Commissioning of existing exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. |
| 12 | SITC of 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections. |
| 13 | SITC of Following Capacity 315A TPN tap off box made of 1.6MM sheet enclosure duly painted with powder coating on existing rising main complete with TPN disconnector FSU and HRC Fuses connection earthing. |
| 14 | Supplying Installation, Testing and Commissioning of following capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required.63 A TPN, 6 way |
| 15 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 16 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm) |
| 17 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 18 | Supply of CO2 type fire extinguisher cylinders filled (4.5Kgs) and Fixing on Wall or as per directions of Engineer in -Charge |
| 19 | SITC of Wall Mounted Fan , 1350 RPM , 48 Watt, 400mm, Double string for Speed & Oscillation control withThermal Overloaded Protected Motor | 100% Copper Wire Winding Motor 230 Volts (Black Decker/Orient/Havells) |
| 20 | Supply of Exhaust Fan , 300mm Electric Exhaust Fan for Kitchen | Front-guard and Powder-coated Body sweep size of 225mm and a speed of 1350 RPM. 60Watt or above (Orient/Khaitan/Havells) |
| 21 | Single Phase Overvoltage and Undervoltage Protection Device for Home Use, 230V AC, 40A, 63A, Voltage Relay Protector with Overcurrent Protection, 1pc(40A) (Make - Non Chinese) |
| 22 | SITC of 5KVA Solar Hybrid Offline Inveter, Nominal Battery Voltage 48 Volt , Input Voltage 130-230V, Smart Solar optimization, Maximum Panel Capacity 5000Wp (SUKAM/LUMINOUS/EXIDE) |
| 23 | SITC of 150AH Tall Tubular Inveter Battery along with accessries like cables, nuts/bolts and rack. Batteries to be connected with Inveter (LUMINOUS/TATA/EXIDE) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender