Tender For Construction Of Public Toilet Nearby Registry Office Under Dhanwar Nagar Panchayat
Tender Value
20.03 Lakhs
Estimated cost
Bid Submission
25 Sep 2026
17 days left
EMD
40078
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Giridih → Jharkhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Public Toilet Nearby Registry Office Under Dhanwar Nagar Panchayat
BOQ
| Sl. No. | Item Description |
| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil & disposal of surplus excavated soil as directed, within or outside the site at an unobjectionable place. i) All kinds of Soil |
| 3 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - of 50 M and lift of 1.5M all complete as per building specification and direction of E/I) |
| 4 | Filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead and taxes all complete as per building specification and direction of E/I. |
| 5 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. |
| 6 | Construction of Embankment with approved material obtained from Borrow pits with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table |
| 7 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration |
| 8 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos / Lindane emulsifiable concentrate of 20% |
| 9 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 10 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 1:3:6 (1 Cement: 3 Coarse Sand: 6 Graded stone aggregate of 20mm) Under Floor |
| 11 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: 1:4:8 (1 Cement :4 Fine Sand: 8 Graded stone aggregate of 40mm) |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level 1:2:4 (1 Cement: 2 coarse sand (zone-III): 4 graded aggregate 40 mm nominal size) |
| 13 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 15 | Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I. (TMT Fe 500 (only valid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizag steel (RINL)) |
| 16 | Providing Tor steel reinforcement of 10mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I. (TMT Fe 500 (only valid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizag steel (RINL)) |
| 17 | Providing Tor steel reinforcement of 12mm. to 25mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/I. (TMT Fe 500 (only valid for TATA (TISCON), SAIL, JSPL, Electro steel Limited Bokaro and Vizag steel (RINL)) |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roof, landings, balconies and access platform |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, abutments, Posts and struts |
| 22 | Providing designation 75 B brickwork in CM (1:6) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 23 | Providing Designation 100A B/W with Fly Ash Lime Brick (FALG) conforming to IS 12894-1990 (9\\"x4.5\\"x3\\") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints, cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 24 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I |
| 25 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry |
| 26 | Providing designation 112 mm thick reinforced designation 100 A brick work with fly ash lime brick (FALG) conforming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I. |
| 27 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 28 | Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both vertical sides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer-in-charge. |
| 29 | Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 23 mm x 30 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (±0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete as per manufacturer's specification and direction of engineer in charge. ii) Decorative finish |
| 30 | Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting, hoisting, fixing in position & applying a priming coat of approved steel primer etc. as required. |
| 31 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 -- Part 3 (ii) Sites with structure height more than 20m for all wind speeds SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.. Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system (Height upto 1.8m). |
| 32 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm) |
| 33 | Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 SQM |
| 34 | Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 35 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 36 | Providing & laying vitrified floor tile Matt/Antiskid finish in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified by Engineer-in-charge. ii) Flooring with size of Tiles 60x60Cm in cement mortar 1:4 |
| 37 | Providing & fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (minimum thickness of 5 mm) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade. |
| 38 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1: 4 (1 cement: 4 coarse sand) |
| 39 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 40 | Providing and laying cement plaster on surfaces with fine sand including curing etc 12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) |
| 41 | Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) |
| 42 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I. |
| 43 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Same as internal plaster + Outer Plaster |
| 44 | Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including taxes and royalty all complete as per building specification and direction of E/I. |
| 45 | Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) |
| 46 | Providing two coats of dry distemper of approved shade and make over a primer coat of washing over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction E/I. |
| 47 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coat Same qty Structure work & Window Grills over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 48 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofing coating as per manufacturer specification - With following steps: (a) surface preparation: Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt. Ltd. / MYK Schomberg / Dr Fixit / Fosroc or equivalent. Providing and repairing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sand 1:4) admixed with acrylic polymer of Sika / Fosroc / MYK Schomberg / Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concrete in base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material. (b) 1st Coat: Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. (c) 2nd Coat: To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/Sqmt/coat. After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/I. The Waterproofing Brand: Sika Topseal 109hi / Fosroc Brushbond RFX / Dr Fixit Pidifin 2K / MYK Aqrain TG. (D) Protection of treated with PCC: The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mtx2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the screed concrete. All corners shall be chamfered with 150mm X 150 mm fillet. (e) Groove of PCC surface should be filled with Polysulphide Sealant. |
| 49 | Providing and filling of Groove between 50 mm PCC Panels with Polysulphide Sealant (Pouring Grade) as per drawings and Technical specifications and direction of E in Charge (with 18% GST). Brand:- Sika-Polysulphide, Fosroc-Thioflex 600, Dr. Fixit Pidiseal PS (42P), MYK Seal PS or Equivalent |
| 50 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over the P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. |
| 51 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design in 75x75 mm deep chase |
| 52 | Providing Retro-reflective regulatory sign board of size 900 mm diameter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro-reflective sheeting as approved by Engineer-in-charge. Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement. Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge. |
| 53 | Providing and fixing of Glass Fiber Reinforced Concrete (GFRC) Screen with borders 50mm thick and inner portion 35mm thick in approved size, pattern, Design, thickness and color. The Screen should be made From 53 grade white Portland cement/ 43 grade OPC or PPC gray cement manufactured by J.K. Cement or equivalent having minimum compressive Strength of 40N/mSQM, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by Saint Gobain, Owens Corning or equivalent, super plasticizers and polymers manufactured by BASF, Sika, MYK Schomburg or equivalent. The material casting should take place in Synthetic Rubber / FRP Mould manufactured by Reckli or equivalent. The Fixing of Column should be Dry Fixing i.e. to be done with MS Frames, Stainless Steel (SS-304) dash fasteners and pins. |
| 54 | SAND (UPTO 49KM LEAD) |
| 55 | CHIPS (UPTO 22KM LEAD) |
| 56 | BRICKS (UPTO 8KM LEAD) |
| 57 | Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-7098. (Part-1). 2 Core x 16 sq. mm Aluminium Cable FRLS. |
| 58 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 2 core 16sq. mm. |
| 59 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 60 | Supply, fabrication & erection of EB meter board with provision for energy meter (energy meter will be supplied by EB) including 1 no of 63A HRC fuse unit and fuse base, neutral link, Bakelite connectors, inter-connections etc as required in hensel box size 300X300X182mm. (Excluding cost of energy meter) as per standard drawings |
| 61 | Earthing with G.I. earth plate 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 62 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required. |
| 63 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required. Group C |
| 64 | Supplying and fixing of following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 module frame |
| 65 | S/F Modular type switch/ socket :- 15/16 amps, one way modular switch, ISI Marked |
| 66 | Supplying and fixing following modular switch / socket on existing modular plate & switch box: 15/16 amps, 6 pin socket outlet |
| 67 | S/F S.P. MCB DB :- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door |
| 68 | S/F DP MCB isolator :- Supplying and fixing following rating double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amp DP MCB |
| 69 | Supplying and fixing following rating double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Upto 32A DP MCB |
| 70 | Supplying and fixing following rating double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Upto 32A SP MCB |
| 71 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 72 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 73 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 74 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 75 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 76 | SITC of following rating recess / surface mounted LED round / square shape down light luminaire with pressure die cast housing for single phase supply voltage. Luminaire shall confirm to IS: 10322 part -5/ section -2 or IEC:62722 with all necessary accessories as required. 12W LED Round Down Light |
| 77 | SITC of 300 mm (12\\") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required |
| 78 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. CCT shall be 5700 Kelvin, LED efficacy minimum 100 lumens/watt with 72 months warranty. |
| 79 | Providing and fixing male ended 15 mm dia brass bib cock of approved quality (wt not less than 350 gms) with extra socket all complete as per specification and direction of E/I. |
| 80 | Providing and fixing 15 mm dia and 45 cm. long P.V.C connection pipe with heavy brass coupling at both ends etc. all complete as per specification and direction of E/I. |
| 81 | Providing and fixing 15mm size C.P brass pillar cock (Weight not less than 350 gms) C.I body brass spindle pillar cock of approved quality as per specification and direction of E/I. |
| 82 | Providing and fixing Gun metal full way valve of approved quality, all complete as per specification and direction of E/I. 32 mm dia wt not less than 700 gms |
| 83 | Providing and fixing Gun metal full way valve of approved quality, all complete as per specification and direction of E/I. 40 mm dia wt not less than 1kg |
| 84 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. (a) Mirrors of 6 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and CP hinges to fix with mirror 600x450 mm size |
| 85 | Supplying, fitting and fixing C.P brass liquid soap container complete with all materials as per specification and direction of E/I. |
| 86 | Supplying, fitting and fixing 40 mm high vitreous white glazed earthenware E.W.C. with 'P' trap of Parryware / Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. bracket with white/black plastic solid state seal and seat with hinges, telescopic flush pipe with brass coupling, spindle stop cock, 510 mm long 12.5 lit. low level P.V.C. cistern, 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer complete. |
| 87 | Making holes in wall for laying H.C.I. pipe and restoring the same after pipe laying as per specification and direction of E/I. 125 mm dia |
| 88 | Providing and fixing toilet paper holder: C.P. brass |
| 89 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe. 32 mm Dia |
| 90 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 91 | Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes confirming to IS: 13592 Type A including jointing with seal ring confirming to IS: 5382 leaving 10mm gap for thermal expansion. 110mm dia |
| 92 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS: 13592 Type A including jointing with seal ring confirming to IS: 5382 leaving 10mm gap for thermal expansion. Coupler 110 mm dia |
| 93 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS: 13592 Type A including jointing with seal ring confirming to IS: 5382 leaving 10mm gap for thermal expansion. Single Tee with door 110x110x110 mm |
| 94 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS: 13592 Type A including jointing with seal ring confirming to IS: 5382 leaving 10mm gap for thermal expansion. Bend 87.5 deg 110 mm |
| 95 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised - Rigid PVC rain water pipes confirming to IS: 13592 Type A including jointing with seal ring confirming to IS: 5382 leaving 10mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe |
| 96 | Providing and fixing unplasticised- PVC pipe clip of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screws with M.S. Screw of required length including cutting brick work and fixing in cement mortar 1:4 (1 Cement: 4 Coarse sand) and making good the wall etc. complete. 110mm dia |
| 97 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of appx. size 610x390x370mm having pre & post flushing with water (250ml & 500ml consumption) having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification & direction of Engineer-in charge. |
| 98 | Providing and fixing C.P. brass angle valve of approved quality conforming to I.S:8931. 15 mm nominal bore |
| 99 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams. |
| 100 | Providing and fixing wash basin with CI brackets, 15mm brass pillar taps, 32mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White vitreous china wash basin size 550 mm x 400 mm with a single 15mm CP brass pillar tap. |
| 101 | Providing fixing, testing and commissioning in position SWR PVC PIPE TYPE-B pipe conforming to IS:13592 including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/clean out plugs, clamps /supports/ hangers etc. jointing with PVC Adhesive joints including cutting holes in walls, core cutting in slabs and making good the same. all complete as per specification and direction of E/I. 150 mm dia |
| 102 | Providing fixing, testing and commissioning in position SWR PVC PIPE TYPE-B pipe conforming to IS:13592 including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/clean out plugs, clamps /supports/ hangers etc. jointing with PVC Adhesive joints including cutting holes in walls, core cutting in slabs and making good the same. all complete as per specification and direction of E/I. 100 mm dia |
| 103 | Providing fixing, testing and commissioning in position SWR PVC PIPE TYPE-B pipe conforming to IS:13592 including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/clean out plugs, clamps/supports/hangers etc. jointing with PVC Adhesive joints including cutting holes in walls, core cutting in slabs and making good the same. all complete as per specification and direction of E/I. 75 mm dia |
| 104 | Providing & fixing C.P. hand spray with lever control (health faucet) and flexible hose 1 m long (Make: Jaquar, Hand Shower (Health Faucet) ALD-CHR-573) connection with C.P. holder for hand spray complete in all respects as per direction of Engineer-Incharge. |
| 105 | Providing and Fixing in position Hindware make or equivalent CP Grab Bar with wall flanges 600 mm to wooden cleats with C.P. brass screws complete in all respects. |
| 106 | Supplying and fixing 100 mm dia SWR PVC End Cap (Clean Outlet Plug) fittings of approved make. all complete as per specification and direction of E/I. |
| 107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal Work - Exposed on Wall 15 mm nominal outer dia pipes. |
| 108 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal Work - Exposed on Wall 20 mm nominal outer dia pipes. |
| 109 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal Work - Exposed on Wall 25 mm nominal outer dia pipes. |
| 110 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal Work - Exposed on Wall 32 mm nominal outer dia pipes. |
| 111 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all (CPVC) plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal Work - Exposed on Wall 40 mm nominal outer dia pipes. |
| 112 | Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 15 mm nominal outer dia pipes. |
| 113 | Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia pipes. |
| 114 | Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia pipes. |
| 115 | Providing and fixing Chlorinate Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This including jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia pipes. |
| 116 | Fixing water meter and stop cock in G.I pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). |
| 117 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (i) Domestic tank |
| 118 | Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 grams with threaded end for hose connection. |
| 119 | Supplying and fixing C.I. cover without frame for manholes: (COVER MIN. 4.5 KG & FRAME MIN. 2.7 KG) 150x100mm size P type With FPS bricks |
| 120 | Providing and fixing square mouth SW gully trap grade 'A' complete CI grating brick masonry chamber with bricks of class designation 75 and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. |
| 121 | Construction brick masonry manhole in cement mortar 1:4 (1 cement: 4 coarse sand) RCC top slab with 1:2:4 mix with 75 class designation bricks in cement mortar 1:4 foundation concrete 1:4:8 mix inside plastering 12 mm thick with cement mortar 1:3 finished with floating coat of neat cement and making channels in cement concrete 1:2:4 finished with a floating coat of neat cement complete as per standard design. Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensions total weight of cover and frame to be not less than 38 Kg. (weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 Extra for depth for manholes |
| 122 | GST and Labour Cess |
| 123 | Add GST 18% |
| 124 | Add Labour Cess 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysSep 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender