Tender For New Construction Of Cycle Stand R , Boundary Wall, Stage, Main Gate Of Government Etei, Phulbani (Ct) Buildings.
Tender Value
38.72 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
11 days left
EMD
38800
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kandhamal → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for New Construction Of Cycle Stand R , Boundary Wall, Stage, Main Gate Of Government Etei, Phulbani (Ct) Buildings.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundation in all kinds of soil including dressing and leveling the bed and depositing the soil within initial lead of 50 M and initial lift of 1.5 M as may be directed and providing shoring and shuttering & struts if necessary complete. |
| 2 | Supplying, filling in foundation and plinth with sand well watered and rammed in 22.5cm 9\\" layers with all leads and lifts cost, conveyance, labour, T&P etc. complete (measurement will be taken on finished compacted section only.) |
| 3 | Cement concrete (1:3:6) in foundation and plinth with h.g.c.b. metal of 4cm. (1/2\\") size including lowering, laying, cost, conveyance, royalties, taxes, labour, T&P watering, curing etc. complete. In all respect |
| 4 | Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge. |
| 5 | Fly ash brick masonry in cement mortar (1:6) using 25 Cm. x 12 Cm. x 8 Cm. size fly ash bricks having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % in foundation and plinth |
| 6 | Fly ash brick masonry in cement mortar (1:6) using 25 Cm. x 12 Cm. x 8 Cm. size fly ash bricks having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % in Superstructre |
| 7 | Reinforced Cement concrete work of M 20 with 12mm & 20 mm size chips. for R.C.C work including cost of Centering & shuttering charges. A. Footing |
| 8 | B. Plinthbeam |
| 9 | C. Column Above Plinth Level |
| 10 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 11 | Cutting, bending, binding and tying the M.S. Rod or Tor steel for RCC work in cluding cost of all labour and materials etc. complete as per direction of Engineer-in-charge |
| 12 | Providing 12 mm thick Cement Plaster in all floors at all height with cement mortar of mix (1:6) with approved grade cement and with screened and washed sharp sand for mortar and finished smooth to the rough surface of brick masonry walls after racking out joints including watering and curing, rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. |
| 13 | Providing 16 mm thick Cement Plaster in all floors at all height with cement mortar of mix (1:6) with approved grade cement and with screened and washed sharp sand for mortar and finished smooth to the rough surface of brick masonry walls after racking out joints including watering and curing, rounding of corners etc. complete with cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. |
| 14 | Priming one coat with wall primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. |
| 15 | Painting two coats with approved anti-fungal weather seal paints (ISI) of approved colour, shade on wall surface including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge. |
| 16 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. |
| 17 | Providing,fitting and fixing TATA Dura sine colour coated 0.45mm Tata brand in roof .Drilling holes in windties including fixing of Ridges,Valleys and windties including cost of sheets,labour etc.complete. |
| 18 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. |
| 19 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 Mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffinhg, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required for the work complete in all respect. |
| 20 | Supplying, fitting & fixing of Vitrified Industrial tiles in floors of size 600mmx 600mm of approved make confirming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge (for New Work only ) |
| 21 | PH Works.Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.Ground Floor25mm dia C-PVC pipe (sch-80) (Ori Plast/Finolex/Supreme Make) |
| 22 | 32mm dia C-PVC pipe (sch-80) (Ori Plast/Finolex/Supreme Make) |
| 23 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.15mm dia CP angle stop cock (Jaquar)CON-CHR-059KN |
| 24 | CP Extension Piece |
| 25 | 125mm CP Grating |
| 26 | C.P. Flange |
| 27 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. |
| 28 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) e (Ori Plast/Finolex/Supreme Make Type-B) |
| 29 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 30 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 31 | 110mm U-PVC Socket plain (Ori Plast/Finolex/Supreme Make) |
| 32 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge.550mmx400mm W.H.basin (Jaquar/ Johnson/perryware make)with 15mm dia C.P. pillar cock |
| 33 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.Towel ring (Plaza/ Johnson Make) |
| 34 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.CP soap holder |
| 35 | Supplying all materials labour T&P and constructing 0.9m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 36 | E.I Works.Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( anti-bactorial and flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-Next gen) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( anti-bactorial and flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-Next gen) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group- A |
| 37 | Group-B. |
| 38 | Group-C |
| 39 | Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( ( anti-bactorial and flame retradant type) with suitable size modular box & metallic cover plate (both side)( anti-bactorial and flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-Next gen)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 40 | Recessed wiring to submain in the following sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metalic heavy duty flexible conduit 1.6mm thick along with the following sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required. (Make of wire Finolex / KEI/ Polycab/ L&T/ Anchor) 2x2.5mm2 + 1x1.5mm2. in 20mm dia |
| 41 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years |
| 42 | Supplying and fixing 32 Amps DP 240 volts MCB 240 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge.Warranty will be 1 year. |
| 43 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 . the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years. |
| 44 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 45 | S/F. of 1x18Wt. LED tube light fiting (Philips / Panasonic / Havels) make. |
| 46 | Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/ LT/ Havells/ Philips/ Wipro/ Crompton/ Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 47 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 4 core x 6 sq mm (for small power) |
| 48 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 49 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 50 | Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 32 mm Dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender