Tender For Civil And Allied Works For Open Gym Park In Zirconium Complex Township, Pazhayakayal, Tuticorin.
Tender Value
82.38 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
7 days left
EMD
1.64 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tuticorin → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Civil And Allied Works For Open Gym Park In Zirconium Complex Township, Pazhayakayal, Tuticorin.
BOQ
| Sl. No. | Item Description |
| 1 | General Notes:1. Scaffolding is included for all the items for all heights/depths whether specified in the item or not, the contractor shall quote rates accordingly2. The contractor shall follow relevant IS codes/technical specifications for execution of work.3. The contractor shall maintain good workman ship and follow safe working procedures during the work. |
| 2 | EXCAVATION |
| 3 | Earthwork in excavation by mechanical means (Hydraulic excavator)/ manual means in Trenches, foundation for septic tanks, pipes, sewers, storm water drains, footings etc in all soils except soft and hard rock at all depths from average ground level including dewatering if necessary, dressing bottom to required level, profile/slope, clearing of all the areas involving excavation of all grass, rank vegetation, shrubs,bushes,cutting of trees upto 300mm grith measured at 1.0 mtr above ground level disposing the soil within a distance of 50m, complete as directed. |
| 4 | Earthwork in surface excavation in all soils (not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 sqm in plan) and including disposal of excavated earth up to 50m and 1.5m lead disposed earth to be levelled & neatly dressed, with all lead and lifts including all material, Labour, tools and plants etc., and as directed by engineer in charge. |
| 5 | Filling available excavated earth in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, levelling, lead up to 50 m. |
| 6 | Excavating, supplying and filling of beach sand available locally by mechanical transport for all leads , including royalty, ramming, watering, compacting of the earth in layers not exceeding 20 cm in top/bottom/sides of foundation, trenches, road formation, reservoir etc. complete for all leads and lifts as directed by EIC. |
| 7 | Lead charges, including loading, unloading, stacking, the disposable Earth, rock, concrete, brick, debris, other unserviceable materials etc. by Mechanical transport for all leads within ZC.Note: Measurement of lead charges will be based on truck measurements with deduction of voids @20% and 50% for soils and rocks or debris respectively. |
| 8 | CONCRETING AND FLOORING |
| 9 | Plain Cement Concrete (P.C.C) 1:3:6 by insitu mixing using Weigh Batching or RMC of Grade M-10 using Portland Slag Cement conforming to IS 455 (M/s. ACC,Ultra Tech, Raasi, Birla, Coromandal, Andhra Cements Ltd. make) with crushed stone sand and graded stone aggregates of 20mm maximum size at all depths/heights below/above plinth level including consolidation, finishing smooth/broom finish as applicable, curing, etc., but excluding Formwork, complete as specified and directed. |
| 10 | Reinforced Cement Concrete by insitu mixing using Weigh Batching or RMC of Mix of Grade M - 30 in below and above plinth level using using Portland Slag Cement (PSC) conforming to IS 455 (M/s. ACC, Ultra Tech, Raasi, Birla, Coromandal, Andhra Cements Ltd. make) with crushed sand and graded stone aggregates of 20mm/10mm/6mm maximum size including mixing superplasticizer of brand M/s. Fosroc, Demech, Huntsman, Pidilite, Sunanda Chemicals, Agro Chemicals, MBT in proportion as per Manufacturer's Specifications, Pumping / Lifting of concrete to the required heights, Concrete laid to proper level, profile and slope, placing concrete, consolidation, finishing, curing, etc., but excluding Formwork as specified and directed. |
| 11 | Plum concrete with M-10 cement concrete, using Ordinary Portland Cement(OPC) conforming to IS 269 or Portland Pozzolana Cement (PPC) conforming to IS 1489 Part-1 (M/s. ACC,Ultra Tech, Raasi, Birla, Coromandal, Andhra Cements Ltd. make) with crushed stone sand and graded stone aggregates of 20mm maximum size at all depths/heights below/above plinth level to be filled in all interstices (not less than 150mm) with plums not exceeding 50 percent of total volume of plum concrete using cobble.round stone of size 25mm to 300 mm and shall be hard durable and tough. The water cement ratio shall be adjusted at site to maintain the flowability of concrete to fill all the interstices properly laid to proper level, profile and slope, placing concrete, consolidation, finishing, curing, etc., as specified and directed. |
| 12 | Supply, fabrication and erection of Reinforcement bars for Reinforced cement concrete items at all depths and heights below and above plinth level Thermo-Mechanically Treated bars of minimum grade Fe-500D/550D or more conforming to IS 1786 of Tata, Vizag steel, Sail, JSW, JSPL make, including transport to site, loading and unloading, making fan hooks of required shape, dowels for bonding masonry, transporting steel to site, decoiling, removing of scales, straightening, cutting, bending, fixing bars with chairs, space bars wherever required, in position with two strings of 18 gauge soft drawn annealed MS binding wire inclusive of its supply etc., providing cement cover blocks of adequate strength, complete as specified and as per direction of Engineer- in-Charge. Note: The grade of reinforcedment bars shall be gotten approved by EIC before procurement. |
| 13 | Providing centering and shuttering using steel shuttering plates at all depths and heights below and above plinth level, vertical, horizontal, inclined including strutting, propping using steel pipes/acro stagging, removal, cleaning of the same for insitu reinforced cement concrete and in plain cement concrete work as required including chamfers, splays, keys, wedges, nails, bracings, brackets and applying one coat of shuttering oil of CEMOL on all shuttering surfaces coming in contact with concrete etc., complete as directed. |
| 14 | Providing and laying precast cement concrete paver tiles of minimum thickness 25 mm, minimum garde M-20, minimum size 300mmX300mm in footpath & courtyard etc of required design, texture, color & shades, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand), grouting the joints with white cement/cement slurry and matching pigments etc. all complete as per the direction of Engineer-in-charge |
| 15 | Providing and fixing 16 to 18 mm thick gang saw cut, mirror polished, premoulded and prepolished/honed/leathered/lappato or in combination machine cut Granite stone for floor/treads/ risers /steps / dado/ ramps/window sills/jambs/wash basin platforms etc. of required size, approved shade, colour and texture laid over minimum 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse crushed stone sand)/ 12 mm thick, 1:3 (1 cement : 3 coarse crushed stone sand) cement mortar/chemical adhesive, joints treated with epoxy grout, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish, making cutouts in granite for washbasin/pillar taps/any other fittings etc. complete at all levels including cost of single/double nosing, making 3 no of grooves for saircase treads etc. all complete as specified and as directed. |
| 16 | Providing and laying machine cut chissel dressed polished kota/Shahbad stone slab of approved shade in floor, tread, landing, riser, skirting, dado over and including a bed of cement mortar including preparing the base surface, applying neat cement slurry @ 2.75 Kg of cement per Sq.m. of area to receive the mortar, providing neat cement slurry @ 4.4kg. of cement /Sq.m. of area over the mortar bed, jointing each slab with neat cement paste/ grouting white cement and pigment ( conforming to IS : 2114, Table-1, matching the shade of slabs), machine cutting of the slab edges square, true & plumb finishing, grinding, polishing, finishing etc. all complete. |
| 17 | 25mm thick kota/Shahbad stone slab (with tolerance +_2mm for thickness, +_2mm for length/ breadth) in floor tread, landing, riser, skirting, dado over 20mm thick cement mortar 1:4(1 Cement : 4 coarse sand by volume) for floor/tread/landing and 12mm thick cement mortar 1:3(1 Cement : 3 coarse sand by volume) for dado/skirting/risers etc. |
| 18 | Providing, laying & fixing Precast Accupressure Block of 60 mm thick Triangular Pointed as per approved shape, Size, design & colour combination of M/s CONCRETO or as per approved Manufacturer, Laid over a layer of 20 mm thick CM 1:4 bedding over well consolidated sub-base including filling the joints with CM etc. transport to site, placing to proper line & level etc. including cost all material, labour , tools Wastage etc complete as per sepcification drawing as directed by E-I-C-400mmX400 mm or size as per approved Accupressure block of 60mm thick Triangular Pointed/as per approved shape, for Accupressure Graden & Internal Walk way. |
| 19 | MASONRY AND FINISHING |
| 20 | Random rubble stone masonry using approved local stones in foundations/ pedestals and plinth at and at all depths/heights below and above plinth level in cement mortar 1:6 bond stones, curing, etc., using crushed sand of grade conforming to BIS 2116, complete as specified and directed. |
| 21 | Brick work as per IS 2212 using fly ash bricks conforming to IS 12894 of Class Designation 7.5 and above as specified at all height and depths with cement mortar 1:6 {1 cement (M/s. ACC, Ultra Tech, Raasi, Birla, Coromandal, M/s. Andhra Cement Ltd., KCP) : 6 crushed Sand} including raking out joints and simultaneously pointing the joints with the same mortar, curing, scaffolding etc., complete as specified and directed. |
| 22 | HALF BRICK masonry as per IS 2212 using fly ash bricks conforming to IS 12894 of class designation 7.5 or above as specified in partitions walls in cement mortar 1:4 (1 cement: 4 crushed sand), including scaffolding, raking out joints, curing etc. complete and with Reinforced Cement Concrete (RCC) M15 (1:2:4) stiffeners of depth 75mm at every 900 mm height including form work, curing etc., complete as specified and directed, but excluding reinforcement. Note: Reinforcement will be measured and paid for separately under relevant item of schedule.-above plinth level up to 5th floor |
| 23 | Cement plastering 18mm thick in Two (2) coats over exterior masonry and concrete surfaces at and at all heights/depths above/below plinth level with base coat in Cement Mortar 1:5 {1 cement (M/s. ACC, Ultra Tech, Raasi, Birla, Coromandal, M/s. Andhra Cement Ltd., KCP) : 5 River Sand} 6mm thick and finishing coat in Cement Mortar1:3 {1 cement (M/s. ACC, Ultra Tech, Raasi, Birla, Coromandal, M/s. Andhra Cement Ltd., KCP) : 3 River Sand} 6mm thick final rendering including addition of approved integrated waterproofing compound @ 2% by weight of cement or as per manufacturer’s Specifications for the base coat of make M/s. Fosroc/Demech/ Huntsman/ Pidilite/ SIKA Qualcrete / MBT/Sunanda Chemicals, making necessary grooves, bands, drip moulds, providing & fixing GI plaster mesh/chicken mesh 150 mm wide along route of walls chipped for service lines, junction between RCC and brick walls and also other places wherever required over brick walls or concrete surface, preparation of surface, hacking of surface, double steel/tubular scaffolding wherever necessary, curing, etc., complete as specified and directed. |
| 24 | Applying 2 (Two) coats of ready made external putty of average thickness 1 mm of Birla wall care/J.K. Wall putty over plastered wall surface including cleaning the surface with steel scrapper, wire brush, sand paper etc., filling in crevices, holes, cracks with approved filler etc., finishing the surface neat and smooth without any undulations as specified and directed at all height including required scaffolding. |
| 25 | EXTERIOR PAINTING :- Applying of Two or more coat of elastomeric liquid applied water proofing membrane of asain paint damp proof advance or Dulux Aquatech Flexible damp proof base coat as per manufacture specification.Finishing walls with 2 or more coat of 100% Premium acrylic Smooth waterproof exterior finish emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS:15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Dept Tinted) with silicon additives, equal to asain paint ultima protek or Dulux Professional weathershield Flexx or Paints can be obtained from approved make from M/s. Asian, Dulux, Berger, Johnson & Nicklson, Nerolac, Pidilite or any other make etc., including surface preparation, scrubbing, sand papering, removing of loose paint, plaster, dirt, etc., filling of cracks, holes with crack filler of make fosroc renderoc CS/CF or approved equivalent complete and as directed. |
| 26 | STEEL WORK AND ROOFING Please Enable Macros to View BoQ information |
| 27 | STEEL WORK AND ROOFING Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender