Tender For Special Repair To Bldg No Np-20, E-22 And Provision Of Other Sanctioned Works In The Aor Of Age B/R-I Under Ge (West) Ferozepur
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Oct 2026
14 days left
EMD
2.10 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Firozepur → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Bldg No Np-20, E-22 And Provision Of Other Sanctioned Works In The Aor Of Age B/R-I Under Ge (West) Ferozepur
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 2 | Demolition of cement concrete of Sunken portion/EWC/IWC of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 3 | Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed. |
| 4 | Demolition of brick work built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed. |
| 5 | Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed. |
| 6 | Taking down cement plaster of any description on brick walls or concrete or stone and ceilings including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 7 | Taking up or down existing 15mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 8 | Taking up or down existing 20mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. |
| 9 | Dismantling structural steel work in cluding doors, gates but excluding framed truss etc complete all as specified and directed. |
| 10 | Dismantling brick tiles or terracing tiles, single layer on roofs jointed and pointed in cement mortar including removal of grass vegitation including roots near out let of RWP and OHT staging area or specifically ordered in writing complete all as specified and directed. |
| 11 | Demolition of mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part hereof ) and removing from site to adistance exceeding 250m but not exceeding 500m complete all as specified. Note :- Demolition of Mud puska to be cut in average thickness from top surface of roof for creating the slope as directed |
| 12 | Dismantling existing PVC tanks of capacity exceeding 250 Litres but not exceeding 500 litres, removing from site complete all as specified and directed. |
| 13 | Dismantling existing PVC tanks of capacity exceeding 500 Litres but not exceeding 1000 litres, removing from site complete all as specified and directed. |
| 14 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 15 | Dismantling asbestos cement/fibre (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. Hacking out old broken glass (any size, thickness, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed. |
| 16 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 17 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed. |
| 18 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size exceeding 1.5 Sqm but not exceeding 4 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed. |
| 19 | Taking down shutters of any description exceeding 1.00Sqm but not exceeding 2.00Sqm each and removing from site complete all as specified and directed. |
| 20 | Taking down shutters of any description not exceeding 2.00Sqm each and refixing in other opening complete all as specified and directed. |
| 21 | Dismantling boarding, any description, fixed in any postion with nails or screws complete all as specified and directed. |
| 22 | Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, complete all as specified and directed. |
| 23 | Cutting existing 40/50/80/100mm bore CI/GI pipes including run lead joints of suitable size with necessary fittings complete all as specified and directed. |
| 24 | Cutting existing 15mm bore steel tubing for additions or alteration (Each cut measured ) and making the connection by threading and providing and suitable size necessary GI fittings by insertion of Tee, bends, sockets, nipples etc for geysers complete all as specified and directed. |
| 25 | Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for internal pipe of dia 150 mm complete all as specified and directed. |
| 26 | Surface excavation in soft/ loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed. |
| 27 | Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out complete all as specified and as direcetd. |
| 28 | Excavating over areass, in soft/loose soil, not exceeding 1.5m in depth and getting out complete aii as specified and as direcetd. |
| 29 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil complete all as directed. |
| 30 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 31 | Removing excavated materials to a distance exceeding 50m but not exceeding 250m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 32 | Spreading and levelling of earth and soil in layers n exc. 25 cm thick and well ramming including. watering as required complete all as specified & directed. Note :- The earth / soil to be used received from excavation. |
| 33 | M&L for Hardcore of broken stones and boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 34 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammedincluding watering complete all as specified and directed. |
| 35 | M&L for Pre-construction Treatment to backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified. |
| 36 | M&L for Pre-construction Treatment to top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified. |
| 37 | M&L for Pre-construction Treatment to oil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 38 | M&L for Lean Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete etc in sunken portion complete all as specified and directed. |
| 39 | M&L for Lean Cement Concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete and filling in Sunken portion complete all as specified and directed. |
| 40 | M&L for Lean Cement Concrete (1:3:6) type C-0 using 10mm graded crushed stone aggregate as in ramps, filling back sides of pressed steel frames complete all as specified and directed. |
| 41 | M&L for Lean Cement Concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate, mixed with water proofing compound as in surface channels and drains; benching of man holes complete all as specified and directed. |
| 42 | M&L for Lean Cement Concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in surface channels and drains; benching of man holes complete all as specified and directed. |
| 43 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.as in manhole pipe line portion only complete all as specified and directed. |
| 44 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 45 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 46 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Beams, cantilevers, bressummers, lintels over1.5m spancomplete all as specified and directed. |
| 47 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 48 | M&L for Reinforced Cement Concrete Design Mix M-30 Grade as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, verticle walls, bottom slab, base slab, od static water tank under-reamed piles and mass concrete complete all as specified and directed. |
| 49 | M&L for Reinforced Cement Concrete Design Mix M-25 Grade as in Chajjas and the like complete all as specified and directed. |
| 50 | Formwork for rought finished flat surface of concrete to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 51 | Formwork for rought finished flat surface of concrete to sides of concrete Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batte rcomplete all as specified and as directed. |
| 52 | Formwork for rought finished flat surface of concrete to to sides of pillars, posts, struts, piers, columns and stanchionscomplete all as specified and as directed. |
| 53 | Formwork for rought finished flat surface of concrete to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed. |
| 54 | Formwork for rought finished flat surface of concrere to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) kitchen platform complete all as specified and as directed. |
| 55 | Formwork for rought finished flat surface of concrete to rough finished surfaces of chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 56 | Formwork for rought finished flat surface of concrete to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 57 | M&L for brick work built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 58 | M&L for brick work built in cement mortar (1:4) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 59 | M&L for brick work (EXCEPT BRICKS) built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after demolition of brick work. |
| 60 | M&L for brick work in half brick thick wall built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 61 | M&L for brick work in half brick thick wall built in cement mortar (1:4) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 62 | M&L for brick work laid on edge in floors, with sub class 'B' old size bricks, bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) complete all as specified and directed. |
| 63 | M&L for Forming jambs, etc. in cement mortar (1:6) to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete complete all as specified and as directed. |
| 64 | S&F 40mm thick (measured solid) Precast Cement Concrete (1:2:4) type B-0 using 12.5 mm graded aggregate as in louvres and jalies, set in 1:4 mortar including all mouldings but excluding frame complete all as specified and directed. |
| 65 | M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate in Cover fillet minimum radius of 75mm as in roof and parapet wall junction, roof benching, kerbs, mud stop, coping, rounded or chamfered on edges, sloping on roof including form work complete all as specified and directed. |
| 66 | M&L Pre-cast Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set in cemet mortar (1:4) including form work complete all as specified and directed. Note:- Reinforcement shall be measured and paid for separately. |
| 67 | M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed blocks for hold fasts roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed. |
| 68 | M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate mixed with water proofing compound as in bed blocks for hold fasts roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed. |
| 69 | S&F Pressed steel frames made of 1.25mm thick CRCA sheet of profile 105x60mm for door and window frames with one rebate including lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 70 | S&F Pressed steel frames made of 1.25mm thick CRCA sheet of profile 125x60mm for door and window frames with one or more rebates incl lock strike plate, shock absorbers, 20mm dia 60mm long MS conduit for housing of a drop bolt, butt hinges, hold fasts/lugs etc and treating of internal surfaces of chowkhats and hold fasts/lugs with a coat of coal tar or black paint incl hinges, hold fasts/lugs etc including making good jambs portion by providing plaster in CM 1:4 and finishes as per existing complete all as specified. |
| 71 | S&F 35mm thick, factory made 2nd class hard wood (Hollock), Plain framed, panelled wooden shutter (any number of panels) (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed. |
| 72 | S&F 35mm thick factory made 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed. |
| 73 | S&F factory made 40mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, one face is covered with decorative face veneer with lipping/frame 6mm thick , 40mm wide teakwood lipping fixed all around with adhesive and headless nails complete all as specified and directed. |
| 74 | S&F Anodised aluminium window and ventilator shutters, powder coated aluminium (minimum 50micron thickness of epoxy powder coating) fixed type, sliding or pull type and push type in shutter frame or shutters with two or three tracks sliding alumium frame , aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. Note:- EPDM Rubber Beading shall be measured and paid for separately. |
| 75 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge,complete all as specified and directed. |
| 76 | S&F EPDM Rubber beading around glass in aluminium windows /ventilator shutters, complete all as specified and directed. |
| 77 | S&F in replacement Factory Made Box Type Steel Windows with glazing bars made of ERW tube hollow \\"P\\" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung skelton & glazed shutters, frame of ERW tube \\"P\\" section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gauge to frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). (viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Glass panes and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment . |
| 78 | S&F in replacement Factory Made Box Type Steel Windows without glazing bars made of ERW tube hollow \\"P\\" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung i.e. guaged shutters, frame of ERW tube \\"P\\" section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gauge to frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). (viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Wire cloth and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment . |
| 79 | S&F in replacement Factory Made Box Type Steel Ventilators side / top hung with glazing bars or dovetailed or welded made of ERW tube \\"P\\"-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and mild steel flat iron 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown onDrawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed:- Note : 1. Grills and guard bars, Sheet glass and wiremesh shall be measured and paid separately. 2. Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). 3. Preparation of steel surfaces of ventlators and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. 4. Area shall be measured flat for one side only for the purpose of measurement and payment . |
| 80 | S&F mild steel framed work with Fe.290.Gde-E-165, such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and directed. |
| 81 | S&F 50mmx47mm size solid PVC door frame made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as specified shown on drawing and specified and directed. |
| 82 | S&F factory made 30mm thick (style) solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified shown on drawing and specified and directed. |
| 83 | S&F 18mm Solid PVC board plain colour ,fixed with screws or adhesive with complete accessories (magnetic catcher, knobs) as in shelves/shutters with rebates fixed on PVC on three sides as in supporting block to shelves complete all as specified and directed. |
| 84 | S&F 18mm thick Prelaminated particle board, exterior grade, prelaminated with one side decorative face of laminations, flat pressed, single or three layer type with BWP type phenol formaldihide adhesive as in cupboard /wardrobe shutters complete all as specified and directed. |
| 85 | S&F in repairs 40 mm dia, cupboard knobs fixed with nut , screw and washer of brass, polished complete all as specified and directed. |
| 86 | S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site complete all as specified and directed. |
| 87 | S&F 100mm size mild steel butt hinges medium weight rolled cold complete all as specified and directed. |
| 88 | S&F 100mm size butt hinges of extruded aluminium alloy with galvanised steel hing pins, anodised and type C-21 complete all as specified and directed. |
| 89 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed. |
| 90 | S&F 200mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed. |
| 91 | S&F 150mm long mild steel barrel tower bolts, stove enameled black, with bright bolt fixed with steel screws complete all as specified and directed. |
| 92 | S&F 150mm size aluminium door handle, extruded aluminium alloy, fabricated type complete all as specified and directed. |
| 93 | S&F 125mm size aluminium door handle, extruded aluminium alloy, fabricated type complete all as specified and directed. |
| 94 | S&F 150mm size aluminium door handle, cast type, anodised complete all as specified and directed. |
| 95 | S&F 125mm size mild steel pressed handle, oval type, stove enameled black complete all as specified and directed. |
| 96 | S&F stainless steel continous (piano) hinges of mild steel bright finish or electro galvanised with flap (when open) 40mm, fixed with steel screw complete all as specified and directed. |
| 97 | S&F 250mm long mild steel sliding door bolt, plate type, stove enameled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed. |
| 98 | S&F 200mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 99 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, with 150mm overall length of cover plate fixed in floor complete all as specified and directed, |
| 100 | S&F 300mm size mild steel helical door spring ordinery rat rail rod pattern spring including roller and roller plate complete all as specified and directed, |
| 101 | S&F 100mm size hasp and staple aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and directed. |
| 102 | S&F in repairs 100mm size, 4-Lever Aluminium Mortice lock, vertical type complete all as specified and directed. |
| 103 | S&F 200mm long PTMT tower bolts and fixed with steel screws complete all as specified and directed. |
| 104 | S&F 100mm long PTMT butt hinges and fixed with steel screws with brass /bronze hinges pin complete all as specified and directed. |
| 105 | S&F 125mm long PTMT handle and fixed with steel screws complete all as specified and directed. |
| 106 | S&F in repairs Aluminium body hydraullically regulated door closer universal type, suitable for door shutters of 851 to 1000mm width & of weight between 61 to 80kg complete allas specified and diected. |
| 107 | S&F Stainless Steel Wire Cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 108 | S&F 5.5mm thick, plain sheet glass, Selected quality and glazing, with oil putty or with wooden/ EPDM Rubber beads (supplied alongwith shutters or to be measured and paid separately), in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed. |
| 109 | S&F 5.5mm thick, plain sheet glass, Selected quality and glazing, with oil putty or with wooden/ EPDM Rubber beads (supplied alongwith shutters or to be measured and paid separately), in squares exceeding 0.50 Sqm in each pane complete all as specified and directed. |
| 110 | S&F 3.0mm thick, plain sheet glass, ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm in each pane complete all as specified and directed. |
| 111 | S&F 25 micron Solar control film reflective type sticked to glass panes exceeding 1.5 Sqm as per instructions of manufacturers complete all as specified and directed. |
| 112 | S&F Structural Steel Fe-410- W(Gde E-250) quality 'B' Rolled sections as in Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.tes complete all as specified and directed. |
| 113 | S&F in repair 1.25mm thickness of laths Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with bevel gear box and crank handle , complete all as specified and directed. |
| 114 | S&F in repair Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 115 | S&F in repair ball bearing for rolling shutters complete all as specified and directed. |
| 116 | S&F Welded steel wire fabric weight exceeding 4Kg per Sqm to wood or steel members, complete all as specified and directed. |
| 117 | M&L for Welding in repairs , thickness of metal to be welded exceeding 6mm, length exceeding 6cm but not exceeding 9cm, complete all as specified and directed. |
| 118 | S&F 10mm dia and over mild steel TMT bars, in reinforcement bars, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 119 | S&F 6 to 8mm dia and over mild steel TMT bars, in reinforcement bars, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 120 | S&F 5mm dia and over upto and including 10mm dia mild steel TMT bars, in reinforcement stirrups, spacers and binders cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. but |
| 121 | S&F PVC Water Bars (D-19) 3-4mm thick and 190mm wide fixed in RCC wall joints continously of approved make complete all as specified and as directed. |
| 122 | M&L for 50mm thick Plain Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and expansion joints filled with bitumen mixed with sand in ratio (1:1) complete all as specified and directed. |
| 123 | M&L for 75mm thick Plain Cement Concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in sub base of flooring,surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed. |
| 124 | M&L for 100mm thick Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring, surface finished even and fair, surface finished rough to receive floor topping or interlocking tiles complete all as specified and directed. |
| 125 | M&L for 75mm thick Plain Cement Concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in sub base of flooring, surface finished even and fair, surface finished rough to receive floor topping or interlocking tiles complete all as specified and directed. |
| 126 | M&L for 25mm thick Plain Cement Concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed. |
| 127 | M&L for 18 to 20mm thick Granite (table rubbed and mirror polished) in steps ,jambs,pillars,cooking platform and like including pointing in white cement 1:2 using marble dust with admixture of pigment to match with marble shade other than white and black types over and including 15mm thick cement screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 128 | M&L for Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, in floors including rubbing and polishing complete over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 129 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, in floors including rubbing and polishing complete over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 130 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, in vertical surfaces such as skirtings, dados, risers and steps etc including rubbing and polishing complete over and including 15mm thick cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 131 | M&L for 10mm thick (square/ rectangular) Vitrified Tiles, light colour, polished, area of each tile not exceeding 0.36Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 132 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality, area of each tile exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 133 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality, Joint-free, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed. |
| 134 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Coloured Tiles, Joint-free, premium quality, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 135 | M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic polished dark shade Tiles, premium quality, area of each tile exceeding 0.18Sqm but not exceeding 0.38Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 136 | M&L for 7mm thick (Area 450 x 300mm / 450x350mm/ 350x250mm/300x200mm) Glazed Ceramic Coloured Tiles, in vertical surfacesX 7 mm th set and jonnted in cement slurry and pointed in white or coloured cement in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed. |
| 137 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 138 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete complete all as specified and directed. |
| 139 | M&L for 10mm thick rendering cement plaster in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 140 | M&L for 10m thick rendering cement plaster in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 141 | M&L for Flush pointing to roof tiles in cement mortar (1:3) tiles grouted finish including racking out joints complete all as specified and directed. |
| 142 | M&L for 15mm thick rendering cement plaster in cement mortar (1:6) on any faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 143 | M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on any faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 144 | M&L for 5mm thick rendering cement plaster in cement mortar (1:3) on ceiling surfaces, soffits of chajjas or roof projection and the like, finished even and smooth without using extra cement complete all as specified and directed. |
| 145 | M&L for 10mm thick rendering cement plaster in cement mortar (1:4) on any faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 146 | M&L for 15mm thick cement plaster in cement mortar (1:4) on any faces of brick walls or concrete surfaces, mixed with water proofing compound, surfaces finished even and smooth without using extra cement forsunken portion complete all as specified and directed. Note: WPC shall be measured and paid separately. |
| 147 | Supply only Liquid water proofing compound complete all as specified and directed. (Note:- WPC shall be mixed @ 200ml/50Kg of cement or as specified by the Manufacturer's Instructions, whichever is more.) |
| 148 | Supply only Integral water proofing compound complete all as specified and directed. ( Note:- WPC shall be mixed @ 3% by weight of cement or as per manufacturer's instructions whichever is more.) |
| 149 | M&L for water proofing treatment to sunken floors of Kitchen, toilets, laboratories, bath and WC's etc shall be as under :- (i) Application of two components of Acrylic modified Cementitious coating(aa) Clean the RCC Surface with wire brush and chisel out and mortar sticking to Surface(ab) Apply FOSROC NITOPROOF 600 PF (min 0.8mm dft) over a priming coat of NITOPROOF WB Primer or equivalent of ASIAN PAINT/SIKA/BERGER/PIDILITE DR FIXIT(ac) Provide HDPE 1.0mm thick Sheet before laying of any floor finishes. |
| 150 | M&L for providing water proofing treatment to static water tank complete all as per the following specifications:-(i) Providing 15mm thick cement plaster in cement mortar (1:3) mixed with pidiproof LW of Dr. Fixit @ 200ml per 50kg of cement and finished even and smooth surface without using extra cement over two coats of cement slurry mixed with super Latex of pidilite in proportion 1:4:7 (super latex : water : cement).(ii) Application of one coat of polymer modified bituminous elastomeric waterproof coating i.e. proof coat black of pidilite @ approx 0.50kg per sqm for two coats of 300 micron each.(a) The rate includes of preparation surface treatment and sealing of all joints, cracks, corners and junctions of pipes etc and ponding test complete all as specified and directed. |
| 151 | M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of bitumen primer @ 0.30 litre per Sqm including preparation of roof surfaces/ sunken portion and all surfaces of sunken portion complete all as specified and directed. |
| 152 | M&L for One layer of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surfaceby forced application complete all as specified. Polymeric membrane shall be taken to a height of 60 cm (minimum) and then inserted inside the groove of parapet walls and shall be finished by a membrane flashing.Note: (i) Laying of APP based membranes shall be done by torch on method or as per manufacturer's instructions.(ii) A minimum overlap shall be 75mm length wise and 100 mm width wise of polymeric membranes respectively and sealed all overlaps and joints as manufacturer's instructions. |
| 153 | M&L for preparation of surfaces of platered, brick, concrete, polymeric etc, of any description, over10cm in width or girth,not otherwise describedone and applying two coats of Solar Reflective Bituminous Aluminium paint @0.1 Kg/ Sqm over APP Membrane complete all as specified and directed. |
| 154 | M&L for 40mm thick brick tiles laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. |
| 155 | M&L for 40mm thick brick tiles (EXCEPT TILES) laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after dismantling brick tiles on roofs/terrace. |
| 156 | M&L for 80mm thick average consolidated thickness mud phuska on flat roof ncluding 25mm thick mud plaster complete all as specified and directed. Note:- Old mud phuska shall not be re-used. |
| 157 | S&F gypsum board panel laminated with texture vinyl coated paper tiles of size 595mmX595mmX12mm thick as in ceiling having snap grid 600mmX600mm incl GI wall angle of size 24mmX24mmX0.43mm thick along with perimeter of ceiling, fixed to walls/partition with the help of nylon sleeves at 450mm centre to centre, suspending intermediate tee section of size 24mmX38mmX0.35mm thick suspended from soffit of ceiling at upto 900mm centre to centre or adjustable as required at site 4mm dia GI wire hangers/tightened with ceiling with the help of nylon sleeve/rawl plugs complete all fittings complete all as specified and directed. |
| 158 | S & F in repair to Hollow PVC wall lining consisting of 5mm thick single side prelam PVC sheet instead of plain colour sheet inclusive of solvent cement and fixing on PVC frame as per specified in MES Schedule Part-I & II complete all as specified and directed. |
| 159 | S&F 2 mm the fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with self tapping screw complete all as specified and directed. |
| 160 | S&F 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified complete all as specified and directed. |
| 161 | S&F 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based plain steel sheetof an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified |
| 162 | M&L for preparing new plastered surfaces of walls and distempering with two coats of distemper oil emulsion (interior grade) white or tinted over one coat of cement primer using rollers etc even and smooth complete all as directed. |
| 163 | M&L for preparing new plastered surfaces of walls and distempering with two coats of distemper oil emulsion white or tinted over one coat of cement primer over 1.0mm thick plaster of paris putty to prepare surface even and smooth complete all as directed. |
| 164 | M&L for complete removal of existing treatment on walls including washing, rubbing down and stopping distempered and painted surfaces, preparation of surfaces and distempering with one coat of distemper oil emulsion white or tinted complete all as specified and directed. |
| 165 | M&L for applying 1.0 mm thick interior/exterior grade wall care putty on surface of walls to prepare surface even and smooth complete all as directed. |
| 166 | M&L for complete removal of existing treatment and preparing old decorated surfaces (plastered or unplastered) by brooming down or steel wire brushing scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greassy spots etc applying 1mm thick Birla wall care putty / JK wall care putty to get fair finish on wall and applying one coat of primer and distempering with two coats of oil bound destemper complete all as specified and directed. |
| 167 | M&L for preparaion of new surface of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade (company depot tinted ) with silicon additives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied at 0.9 litre/10sqm over new surfaces complete all as specified and directed. |
| 168 | M&L for preparing new plastered surfaces of ceiling and applying three coats of lime white wash complete all as specified and directed. |
| 169 | M&L for preparing old plastered surfaces of walls and applying one coat of lime white wash complete all as specified and directed. |
| 170 | M&L for preparing old plastered surfaces of ceiling and applying one coat of lime white wash complete all as specified and directed. |
| 171 | M&L for preparing old distempered plastered surfaces of walls including washing, rubbing down and stopping distempered and painted surfaces filling nails and distempering with one coat of oil bound distemper white or tinted complete all as specified and directed. |
| 172 | M&L for preparing old plastered surfaces of walls including washing, rubbing down and stopping distempered and painted surfaces and distempering with one coat of cement base paint white or tinted complete all as specified and directed. |
| 173 | M&L for preparation of new wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 174 | M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer zinc chromate complete all as specified and directed. |
| 175 | M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 176 | M&L for preparation of old wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 177 | M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 178 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floors complete all as specified and directed. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 179 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls or floor complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 180 | S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 181 | S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.) |
| 182 | S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 183 | S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 184 | S&F 110mm dia PVC (SWR) Branch piece double (double \\"Y\\") equal or unequal complete all as specified and directed. |
| 185 | S&F 75mm dia PVC (SWR)Junction single (single or double \\"T\\") equal or unequal complete all as specified and directed. |
| 186 | S&F 110mm dia PVC (SWR)Junction single (single or double T) equal or unequal complete all as specified and directed. |
| 187 | S&F 110mm dia PVC (SWR) vent cowl complete all as specified and directed. |
| 188 | S&F Cast iron floor trap for 75mm outer dia of pipe with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 189 | S&F in repairs 75mm dia PVC (SWR) multy floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 190 | S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 191 | S&F 20mm outer diameter CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. (Note:- Special fittings shall be measured and paid for as \\"S&F\\" separately . |
| 192 | S&F 25mm outer diameter CPVC pipes SDR 11 with and including Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. (Note:- Special fittings shall be measured and paid for as \\"S&F\\" separately . |
| 193 | S&F 15mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, laid in trenches complete all as specified and directed. |
| 194 | S&F 20mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, laid in trenches complete all as specified and directed. |
| 195 | S&F 40mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, laid in trenches complete all as specified and directed. |
| 196 | S&F in repairs Bib cock chromium plated brass with swan neck regular spout with cruth or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. Make ; PARYAG Cat NO. 9214 or equivalent in Appendix \\"B\\" List of Makes in Particular Specifications. |
| 197 | S&F 15mm bore Bib Taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 198 | S&F 15mm bore fancy type, chromium plated, Stop valves, cast copper alloy, with long shank and cup concealed type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 199 | S&F 15mm bore Angle Valves, fancy type, chromium plated, cast copper alloy, with flange, one way turn, screwed down high pressure, with crutch or butterfly handle, screwed for iron pipe complete all as specified and directed. |
| 200 | S&F 15mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 201 | S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 202 | S&F 40mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed. |
| 203 | S&F in repair pressure Jet spray of chromium plated steel for EWC seats with and including including PVC connection and CP fittings complete all as specified and directed. |
| 204 | S&F in repairs 15mm bore Pillar Taps, fancy type, chromium plated, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 205 | S&F in repairs 32mm bore PVC waste pipe of suitable length to waste coupling pipe attached with rubber ring joints/ PVC threaded cup, fixed to waste coupling of sinks / WHBs/urinal of required length complete all as specified and directed. |
| 206 | S&F in repairs 32mm bore Waste coupling of PTMT for urinals (Minimum weight 32mm 45gms/40mm-60 gms) complete all as specified and directed. |
| 207 | S&F in repairs 32mm bore Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm 45gms/40mm-60 gms) complete all as specified and directed. |
| 208 | S&F in repairs 32mm bore Waste fittings of chromium plated brass for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 209 | S&F in repairs 15mm PVC connections 450mm long heavy duty with brass nuts adaptors and washers and rubber gaskets at both ends complete all as specified and directed. |
| 210 | S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. hoisted and fixed complete as specified in SSR Part-I. complete all as specified and directed. |
| 211 | S&F 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. hoisted and fixed omplete as specified in SSR Part-I. complete all as specified and directed. |
| 212 | S&F in repars 20mm bore Ball valves high pressure of PTMT withepoxy coated Aluminium rod & high density plastic float ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./25mm-455gms/ 40mm- 690 gms) complete all as specified and directed. |
| 213 | S&F 20mm bore Ball valves high pressure of PTMT withepoxy coated Aluminium rod & high density plastic float ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./25mm-455gms/ 40mm- 690 gms) complete all as specified and directed. |
| 214 | S&F in repairs Wash Hand Basins, Vitreous China (flat back) white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting stand including waste fittings, 32 mm bore PVC flush pipe with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and directed. |
| 215 | S&F in repairs Vitreous China Squatting Pan, \\"Orissa pattern\\", size 580x440mm white/ coloured with integral foot rests (excluding flushing cistern, flush pipe and waste pipe), including trap and connection to trap, and to flushing pipe, anti-syphonage pipe, etc.complete including all joints and making good to floors complete all as specified and directed. |
| 216 | S&F in repairs Vitreous China Wash Down Water Closet Pan (pedestal pattern) complete, white/ coloured including seat and cover, trap, including connection to drain (or outgoing pipe), and to flushing pipe, anti-syphonage pipe, etc. etc.complete including all joints and making good to floors complete all as specified and directed. |
| 217 | S&F in repairs Vitreous China urinals, flat back of size 465x355x265mm complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete including all joints and making good to floors complete all as specified and directed. |
| 218 | S&F in repairs 10 litres capacity low level PVC valveless syphonic action type flushing cistern with inlet ball valve, float and flush handle complete all as specified and directed. |
| 219 | S&F Corner glass shelves 300mm radius, 8mm thick as per sample for bath room, fixed on suitable support of brass chromium plated clips compelete all as specified and directed. |
| 220 | S&F 32mm bore Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed. |
| 221 | S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 222 | S&F in repair Stainless steel plate rack of standard pattern & of size 900 x 750 x 250 mm.The thickness of stainless steel sheet shall be 1.00 mm & grade of sheet shall be 304 AISI including fixing to wall with 4 Nos 50mm screws & PVC rawl plugs complete all as specified and directed. |
| 223 | S&F in repairs grating doom 125mm dia of chromium plate steel fixed over trap with white cement complete all as specified and directed. |
| 224 | S&F 100 mm dia Chromium plated brass shower rose with 125mm long CP arms, with or without swivel joints, including fixing complete to steel pipe or union complete all as specified and directed. |
| 225 | S&F 600mmx450mm size of specified thickness looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel around, mounted on 6mm thick commercial ply or AC building board, fitted to wooden plug with chromiumplated brass screws and cup washers complete all as specified and directed. |
| 226 | S&F in repairs 8-10mm thickness looking mirror, bevelled edge of selected quality glass with aluminium frame made of channel around, mounted on 6mm thick commercial ply or AC building board, fitted to wooden plug with chromiumplated brass screws and cup washers complete all as specified and directed. |
| 227 | S&F in repairs 20mm dia brass chromium plated tubular towel rail 600mm long between flanges type \\"D\\", with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and as directed. |
| 228 | S&F in repairs Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and as directed. |
| 229 | S&F in repairs Chromium plated Soap dish of stainless steel of size 160x160mm x 1mm thick, fixed to wall with CP brass screws and PVC gutties complete all as specified and directed. |
| 230 | S&F in repairs CP brass Toilet Paper Holder with Flap fixed to wall with CP brass screws and PVC gutties complete all as specified and directed. |
| 231 | S&F in repairs 20mm dia mild steel epoxy powder coated curtain rod with fancy type brackets including with all fittings rings @ 10 nos per RM , bulbs, finials, fixed with PVC rawl plugs and CP steel screws complete all as specified and directed. |
| 232 | S&F in repairs 15mm bore chromium plated brass Mixer for wash hand basin mounted for mixing hot and cold water screwed down for pipe with provision of overhead shower complete and waste system with 450mm long braided pipe complete all as per manufacturer's instruction and as directed. |
| 233 | S&F in repairs 15mm bore chromium plated brass Wall mixer wall (Non Telephonic/Non over head shower type) mounted for mixing hot and cold water screwed down for pipe, connecting legs and wall flange complete all as per manufacturer's instruction and as directed. Make:- JAQUAR Cat No FLR-5219N, CERA Cat No. F2004405 or equivalent in Appendix \\"B\\" List of Makes in Particular Specifications. |
| 234 | M&L for cement concrete (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in concrete bed for 150 mm bore reinforced cement concrete/SGSW pipes including packing under haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 235 | S&F 150 mm bore (internal dia) salt glazed stone ware (SGSW) pipe, laid on concrete bed to required slope in trenches and jointed complete all as specified and directed. Note:- Excavation, Earth work and Concrete bed shall be measured and paid separately) |
| 236 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 237 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including non metallic rigid heavy duty PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and new CI/MS/GI sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for One light/fan/Bell Point controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. Switches, ceiling roses, pendants, regulators, sockets, bell push and bells shall be measured and paid for separately. |
| 238 | ditto all as per item No 237 above but for One 3 pin socket outlet 5/6 Amp on the same board controlled by one single pole one way switch |
| 239 | ditto all as per item No 237 above but for One 5/6 Amps socket outlet independent controlled by one single pole 5/6 Amp switch. |
| 240 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 2.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 2.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for one 3/5 pin 15/16 Amps switch socket out let on the independent board controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 241 | S&F in repair/replacement Modular Switch, one way, 6A, 1 module complete all as specified and directed. |
| 242 | S&F in repair/replacement Modular Switch, one way, 16A, 1 module complete all as specified and directed. |
| 243 | S&F in repair/replacement Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 244 | S&F in repair/replacement Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. |
| 245 | S&F in repair/replacement Modular white cover plate with frame, 1 module complete all as specified and directed. |
| 246 | S&F in repair/replacement Modular white cover plate with frame, 2 module complete all as specified and directed. |
| 247 | S&F in repair/replacement Modular white cover plate with frame, 3 module complete all as specified and directed. |
| 248 | S&F in repair/replacement Modular white cover plate with frame, 4 module complete all as specified and directed. |
| 249 | S&F in repair/replacement Modular white cover plate with frame, 6 module complete all as specified and directed. |
| 250 | S&F in repair/replacement Modular white cover plate with frame, 8 module complete all as specified and directed. |
| 251 | S&F in repair/replacement Modular Metal Flush Box, 1 module complete all as specified and directed. |
| 252 | S&F in repair/replacement Modular Metal Flush Box, 2 module complete all as specified and directed. |
| 253 | S&F Modular Metal Flush Box, 3 module complete all as specified and directed. |
| 254 | S&F in repair/replacement Modular Metal Flush Box, 4 module complete all as specified and directed. |
| 255 | S&F in repair/replacement Modular Metal Flush Box, 6 module complete all as specified and directed. |
| 256 | S&F in repair/replacement Modular Metal Flush Box, 8 module complete all as specified and directed. |
| 257 | S&F in repair/replacement Modular Bell Push 6A, I module complete all as specified and directed. |
| 258 | S&F in repair/replacement Modular step type regulator,120 W - 2 module complete all as specified and directed. |
| 259 | S&F in repair/replacement Modular Dummy switch- 01 module complete all as specified and directed. |
| 260 | S&F 5/6 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 261 | S&F 15/16 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed. |
| 262 | S&F 5/6 Amp Socket outlet 2 in1, 3 pin flush type ISI marked complete all as specified and directed. |
| 263 | S&F 15/16 Amp Socket outlet 2 in 1, 3 pin flush type ISI marked complete all as specified and directed. |
| 264 | S&F Ceiling Roses Ceiling rose, 3 phase/PVC/polycarbonate, isolated body omplete all as specified and directed. |
| 265 | S&F Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings ISI marked complete all as specified and directed. |
| 266 | S&F bell, Ding Dong AC. 230 Volts, single pole complete all as specified and directed. |
| 267 | Supply, hoist, fix and connect Ceiling Fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 268 | S&F 300mm sweep Exhaust Fan, steel body AC single Phase. 230V, 900 RPM with blades and frame and louvers with Copper winding including cutting holes/ opening, grouting bolts (12mm dia and 15cm long) , fixing with nuts and washers, making connection wih copper onductor PVC flexible twin wire of size 23/0.0076 and including citting holes and making good in cement mortar (1:4) and finshing surfcae to match with existing surfaces complete all as specified and directed. |
| 269 | S&F 300mm sweep Exhaust Fan, sturdy Engineering plastic body with louvers with blades and frame and louvers with Copper winding AC single Phase. 230V , 1200 RPM, 50 Hz including cutting holes/ opening, grouting bolts (12mm dia and 15cm long) , fixing with nuts and washers, making connection wih copper onductor PVC flexible twin wire of size 23/0.0076 and and making good in cement mortar (1:4) and finshing surfcae to match with existing surfaces complete all as specified and directed. |
| 270 | Supply, hoist, fix and connect 25 litres capacity electric water heater, storage type steel body with stainless steel inner tank and heating element upto 2 KW , BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. including cutting holes/ opening, grouting bolts (12mm dia and 15cm long) , fixing with nuts and washers and making good in cement mortar (1:4) and finshing surfcae to match with existing surfaces complete all as specified and directed. Cat Part No. GHWAPP7WH025 of Make - Havells Puro Nu or equivalent as specified in Appendix \\"B\\" of Particular Specfications, complete all as specified and directed. |
| 271 | S&F LED tube light fitting 1 X 18 W, 4 feet long, decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cat Part No. LHEXBLP7UN1W018 of Make - Havells or equivalent as specified in Appendix \\"B\\" of Particular Specfications, complete all as specified and directed. |
| 272 | S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete all as specified and directed. |
| 273 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed. |
| 274 | S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired TPN DBs, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 275 | S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 8 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 276 | S&F Moulded Case Circuit Breaker (MCCB) Four Poles (FP) current carrying capacity 100Amp, 415 Volts, breaking capacity 36 KA with adjustable thermal and magnetic settings, complete all as specified and directed. |
| 277 | S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 6 to 32 Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 278 | S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 40Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 279 | S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 32 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 280 | S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 40 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 281 | S&F in repairs Single Pole two Pin and Earth Plug and Socket including one single pole MCB 20 Amp fixed in and including sheet Metal enclosures, including taking down, complete all as specified and directed. |
| 282 | M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 4.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 4.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 4.0Sqmm and one run of 4.0Sqmm PVC insulated copper conductor single core (2x4.0Sqmm+1x4.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 283 | S&F in repairs submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 6.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 6.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing including taking down existing submain wiring and conduits etc complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0Sqmm and one run of 6.0Sqmm PVC insulated copper conductor single core (2x6.0Sqmm+1x6.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 284 | Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 35 Sqmm x 3.5 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ. |
| 285 | Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 16Sqmm x 2 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ. |
| 286 | Supply and lay 40mm bore galvanised pipe light grade of ISI marked for passing of cable fixed to poles/walls/laid under floor/ laid in trenches as cable protection complete with and including fittings as required compete all as specified and directed.Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately under respective items of BoQ. |
| 287 | M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid. |
| 288 | Supply and lay cable protection cover with Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75, (size 23cmx11.5cmx7.5cm) putting accross the cable with width of protection cover equal to length of brick, abutting to each other for cable protection complete all as specified and directed. |
| 289 | M&L for Earthing complete with Galvanised Iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at (Earth pit not less than 2.25m deep below ground level) a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 4mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanized iron and protected by 15mm bore GI pipe light grade connected to main switch board or main control board and 20mm bore GI pipe light grade for watering and including funnel, wire mesh, 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4Kg/Sqm in lieu of CI cover, PCC (1:2:4) type B-1 pit/chamber including all necessary excavation: and earth work, form work, disposal of surplus soil to a distance not exceeding 50m all as specified and al shown in Electrical Plate No.3 of MES Standard Schedule of Rates 2009 Part-I complete all as specified and directed.Note:- (i) The unit rate shall deemed to include for Test point, PCC pit, 4mm dia GI earth wire from top of the earth plate up to 7.5m above ground level. In case 15mm bore GIprotection pipe required is less than 7.5m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender