Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #57376026

Tender For Repair / Replacement / Maintenance / Rerouting Of Delivary System And Rising Mains Including Ms Pipe Line / Header And Connected Items At 200 Dus, Otm-I, Otm-Ii & Iii, 180 Ors, Bana Singh Enclave, 1 Signal Enclave And Rangpuri And Repair /

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
48.99 Lakhs
Estimated cost
Bid Submission
26 Sep 2026
18 days left
EMD
97980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Replacement / Maintenance / Rerouting Of Delivary System And Rising Mains Including Ms Pipe Line / Header And Connected Items At 200 Dus, Otm-I, Otm-Ii & Iii, 180 Ors, Bana Singh Enclave, 1 Signal Enclave And Rangpuri And Repair / Replacement / Maintenance / Rerouting Of Treated Water Supply Line And Connected Items At Dgis, Ihq C S, Cams, Vikram Vihar, 1 Cbpo Area, Anuj Vihar, Shankar Vihar, Rangpuri And 200 Du In The Area Of Age (U) Water Supply No -Iii Under Ge(U) Water Supply Delhi Cantt-10

BOQ

Name of Work:- REPAIR / REPLACEMENT / MAINT / REROUTING OF DELIVARY SYSTEM AND RISING MAINS INCLUDING MS PIPE LINE / HEADER AND CONNECTED ITEMS AT 200 DUS, OTM-I, OTM-II & III, 180 ORS, BANA SINGH ENCLAVE, 1 SIGNAL ENCLAVE AND RANGPURI AND REPAIR / REPLACEMENT / MAINT / REROUTING OF TREATED WATER SUPPLY LINE AND CONNECTED ITEMS AT DGIS, IHQ C S, CAMS, VIKRAM VIHAR, 1 CBPO AREA, ANUJ VIHAR, SHANKAR VIHAR, RANGPURI AND 200 DU IN THE AREA OF AGE (U) WATER SUPPLY NO -III UNDER GE(U) WATER SUPPLY DELHI CANTT-10
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 metre depth and getting out in any type of soil for pipe line / cables complete all as specified and as directed
2Returning filling in (Soils), including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
3Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed.
4Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines and making good the disturbed surface with and including filling of PCC (1:2:4) type B-2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
5M&L Boring holes under road pavement by bocky manually in any type of soil upto 200 mm bore complete all as specified and directed by Engr-in-Charge. (Note:-Location & depth of trenchless boring is as directed by EIC.
6Taking up GI/Cast Iron/Ductile iron water mains of following bore including all fittings with spigot & socket ends of lead joints incuding burning out lead joints and recovering lead complete all as specified and as directed.(Note :- Excavation & earth work for new location shall be measured and paid separetely.)
780 mm bore
8100 mm bore
9150 mm bore
10200 mm bore
11Supply, laying jointing, testing of DI pipe with class-K-7 spigot socketed ends, conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work & rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes including taking down of existing CI/DI pipe complete all as specified and directed by Engineer-in-Charge. Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ.Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates.Note 3:- Layout plan for laying of DI pipe shall be given by EIC in writing.Note 4 :- Cost of Rubber gasket joints (Tyton Joint) included in quoted unit rates.
1280 mm bore
13100 mm bore
14150 mm bore
15200 mm bore
16Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of following size/bore :-
1780 mm bore
18100 mm bore
19150 mm bore
20200 mm bore
21Supply & Fixing in replacement CI/DI pipe fittings such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of any size confirming to IS: 9523 including taking down existing fitting complete all as specified and directed by Engr-in-Charge.
22Up to 150 mm bore
23200 to 300mm bore
24M&L for run lead joint including jointing material for cast iron pipe of following size/bore :-
2580 MM bore
26100 MM bore
27150 MM bore
28200 MM bore
29Supplying, laying, jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes 8mm thick laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI pipe line, for following size including taking out the old unserviceable pipes :- (Note:- (i) MS Flanges incl fabrication work will be measured and paid separately.(ii) Excavation and earth work will be measured and paid separately.
30100 MM bore
31150 MM bore
32200 MM bore
33250 MM bore
34Supplying and fixing MS flanges of following sizes not less than 6 mm thick duly welded on ends of MS pipe complete all as specified and directed by Engineer-in-Charge.
3580 mm dia
36100 mm dia
37150 mm dia
38200 mm dia
39Supply and Fixing in replacement of CI Foot valve of following size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes complete all as specified and directed by Engineer-in-Charge. Note :- Required rubber packing and suitable nut and bolts is included in the rate.
4080 MM bore
41100 MM bore
42150 MM bore
43Supplying & Fixing, jointing and testing of cast iron sluice valves class PN-1.0 PD short body, conforming to IS:14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from site for the follwing sizes complete all as specified and directed.Note- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
4480 MM bore
45100 MM bore
46150 MM bore
47200 MM bore
48Supply and fixing of Cast Iron Non-Return Valve without bypass arrangement, swing type, confirming to IS-5312, flanged ends pressure rating PN 1.0 including taking out old unsv NRV from the existing place of following sizes:- Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.(ii) Genuine PV's & MTC of vavle be produced by contractor alongwith RAR for payment.)
4980 mm dia
50100 mm dia
51150 mm dia
52200 mm dia
53Supply, installation, testing in replacement of unserviceable flanged ends strainer water meter woltman type, including testing and making good connection with flanged ends with gasket rubber sheet and nut bolts etc ISI marked fixing in horizontal/incline/vertical position, including taking out unserviceable water meter of following sizes complete all as specified and as directed at site by the Engineer-in-Charge. -
54100 MM bore
55150 MM bore
56200 MM bore
57Supply, installation and testing flanged end ends/strainer/dirt box rating(PN 1.0) of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal /inclined/vertical position , including taking out unsv strainer/dirt box complete all as specified and directed at site by the Engr-in-charge. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.
5880 mm dia
59100 mm dia
60150 mm dia
61200 mm dia
62Supply, fixing, jointing and testing in replacement of cast Iron Air release Valve with Two air outlets, confirming to IS, flanged ends complete including taking out unserviceable ARV complete all as specified and directed.
6380mm bore
64100mm bore
65150mm bore
66Material and labour for fabrication welding and fixing of MS work made out of MS sheet not more than 3mm thick of any size or MS Angle/flat of any size as required at site for repair/replacement of valve pit cover/sump manhole cover, staircase steps, signboard and all other iron works including painting two coats with synthetic enamel paints over a coat of red oxide primer complete all as specified and as directed at site.
67Supply and fixing High density polythene pipes (HDPE) 100 mm bore, of pressure rating 10 kgf/cm2, heavy duty laid in trenches.
68Taking out foot valve, NRV, Stainer and refixing the same after refacing, regrinding, including replacement of rubber gasket, nut bolts including painting of following sizes complete all as specified and directed .
6980mm bore
70100 mm bore
71150 mm bore
72200 mm bore
73Opening of existing sluice valve of following size including opening of gland cover taking out with stem nut of brass or of stainless steel & refixing the same after with & including replacement of rubber packing, nut & bolts, glands dori etc complete all as specified and as directed.(Note :- Any new spare parts like stem, stem nuts, gland plate of required size shall be measured and paid separately under respecitve items.)
7480mm bore
75100 mm bore
76150 mm bore
77200 mm bore
78Supply only stem nut made out of stainless steel suitable to match with existing sluice valve of following size complete all as specified and as directed.
7980mm bore
80100 mm bore
81150 mm bore
82200 mm bore
83Supply only stem made out of stainless steel suitable to match with existing sluice valve of following size complete all as specified and as directed.
8480mm bore
85100 mm bore
86150 mm bore
87200 mm bore
88Supply only gland plate made of cast iron suitable to match with existing sluice valve of following size complete all as specified and as directed.
8980mm bore
90100 mm bore
91150 mm bore
92200 mm bore
93Taking up or down GI tubing and connections of the following sizes from trenches / wall / floor including cleaning for refixing or removal complete all as specified and as directed by Engr-in-Charge :-
9415 mm bore
9520 mm bore
9625 mm bore
9740 mm bore
9850 mm bore
99Re-fixing only GI pipe medium grade with all fittings fixed complete to walls and ceiling or in floors on old/new position as directed of following sizes :-(Note:- Old retrieved pipes shall be reused.)
10015 mm bore
10120 mm bore
10225 mm bore
10340 mm bore
10450 mm bore
105Supply and fixing /Laying tubing GI pipe medium grade IS 1239 (Part I)-2004 marked including all fittings laid in trenches/wall/floor etc in old/new position complete all as specified and directed of following sizes:-
10615 mm bore
10720 mm bore
10825 mm bore
10940 mm bore
11050 mm bore
111Supplying and laying in trenches CPVC pipe 50 mm outer dia SDR 11 and Plain CPVC SDR 11 fittings complete all as specified and as directed.
112Supplying and laying in tranches CPVC pipe 25mm outer dia SDR 11 and Plain CPVC SDR 11 fittings complete all as specified and as directed.
113S&F 50 mm outer dia CPVC Union complete all as specified and as directed.
114S&F 25 mm outer dia CPVC Union complete all as specified and as directed.
115S&F 50 mm outer dia CPVC ball valve/gate valve complete all as specified and directed.
116S&F 25 mm outer dia CPVC ball valve/gate valve complete all as specified and directed
117S&F 50 mm outer dia CPVC Brass Elbow complete all as specified and as directed.
118S&F 25 mm outer dia CPVC Brass Elbow complete all as specified and as directed.
119S&F Gun metal gate valve with iron wheel head screwed both iron iron pipe ISI Marked as per IS 778 of following sizes including taking out unserviceable gate valve complete all as specified and directed :-
12015 mm bore
12120 mm bore
12225 mm bore
12340 mm bore
12450 mm bore
125Supply and fixing of MJ Coller, DI Joint for suitable following bore dia pipes complete all as specified and directed:-
12680mm dia
127100mm dia
128150mm dia
129200mm dia
130Construction of valve pit of double brick masonary of sizes 910mmx1060mmx910mm with internal plastering from the top of surface including cover of MS sheet 3.15mm thick and angle iron 40mmx40mmx6mm with hinges and locking arrangement including painting with two coat of synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement morter 1:3, foundation concrete 1:3:6 including necessary earthwork complete all as specified and directed.
131M&L 75mm thick cement concrete type D-2 1:4:8 ( 40mm graded aggregate) as in subbase of floors etc complete all as specified and directed.
132M&L Machine pressed precast concrete coloured paver block rubberised moulded interlocking paverblocks any shape and size in replacement confirming to IS 15658-2006 of 60 mm thick, M-35 Grade with grey cement and pigments, over & including 40 mm thick sand cushioning complete all as specified and as directed.
133S&F, welding of 150 mm dia M.S Pipe Over Flow pipe as per IS 3589, 6mm thick, 15.00 mtr in length with two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed by engineer-in-charge including taking out old, rusted MS over flow pipe of 150mm bore complete all as specified and directed and as described as under:-
134Incoming 100mm dia imcoming of : 03 Nos
135100mm dia outgoing : 03 Nos
136150mm dia outgoing : 01 Nos
137M.S dead plate 150 mm bore 16 mm thick : 02 Nos
138M.S flange 100 mm bore 15 mm thick : 3 Nos
139M.S flange 150 mm bore 15 mm thick : 1 Nos
140Sluice Valves 100mm Dia - 03 Nos
141Sluice Valves 150mm Dia - 01 Nos
142Strainer 100mm - 03 Nos
143Strainer 150mm - 01 Nos
144Water Meter 100mm -3 Nos
145Water Meter 150mm -1 Nos
146M&L for testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) one test in six month for one source in the area under AGE (U) W/S No-III as directed by EIC in the area under AGE(U) W/S No III and submission of detailed test report to the office of Engineer-in-Charge.(a) Collection of water from different sources of water ie Sump, bore wells & shallow wells in sterilized bottle and testing in Govt Approved laboratory as mentioned in specification.(b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, Lead, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission to this office with specific recommendation regarding suitability of water for drinking purpose.Note :- Rate quoted shall deemed to be included for : -(i) Cost of sterilized bottle as required.(ii) To and fro transportation charges for collection of samples from source(sump/bore well/shallow wells)(iii) Contractor will required to visit the site of AGE (U) W/S-III area for working out number of sources i.e borewells/shallow wells/under ground sumps etc. Approximately 30 Number of tests will be carried out in eleven months period(iv) Period of testing of water sources is of 11 (Eleven) months from the commencement of work.
147An amount of Rs 1,96,100.00 shall be deducted from BOQ on account of schedule of credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57376026
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.99 Lakhs
LAST DATE 26-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Replacement / Maintenance / Rerouting Of Delivary System And Rising Mains Including Ms Pipe Line / Header And Connected Items At 200 Dus, Otm-I, Otm-Ii & Iii, 180 Ors, Bana Singh Enclave, 1 Signal Enclave And Rangpuri And Repair / Replacement / Maintenance / Rerouting Of Treated Water Supply Line And Connected Items At Dgis, Ihq C S, Cams, Vikram Vihar, 1 Cbpo Area, Anuj Vihar, Shankar Vihar, Rangpuri And 200 Du In The Area Of Age (U) Water Supply No -Iii Under Ge(U) Water Supply Delhi Cantt-10
Basic Detail
Tender No GE/WS/Token No-50 OF 2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 05 Sep 2026
Submission Date 26 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 48.99 Lakhs
Tender Fee 500
EMD 97980
Exemption Available
Document List
69d669ca-f7e6-4763-a13a-4aaefd9e3166.html
BOQ_883194.xls
tender.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

69d669ca-f7e6-4763-a13a-4aaefd9e3166.html

xls

BOQ_883194.xls

pdf

tender.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders