Tender For Provn Of Children School At Bharatpur Mil Station
Tender Value
10.13 Crore
Estimated cost
Bid Submission
10 Oct 2026
15 days left
EMD
9.80 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Children School At Bharatpur Mil Station
BOQ
| Sl. No. | Item Description |
| 1 | Lump sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 2 | Lump sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY \\" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 3 | Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 4 | Lump sum price worked out by the contractor for \\"ROAD, PATH AND CULVERT\\" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 5 | Lump sum price worked out by the contractor for \\"SEWAGE DISPOSAL\\" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 6 | Lump sum price worked out by the contractor for \\"AREA DRAINAGE \\" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 7 | Lump sum price worked out by the contractor for \\"COMPOUND WALL AND GATE\\" as listed in Schedule ‘A’ Part-VII\\" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 8 | Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 9 | Lump sum price worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 10 | Lump sum price worked out by the contractor for \\"INTERNAL CONDUIT OF TV/CCTV\\" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 11 | Lump sum price worked out by the contractor for \\" SUMMER APPLIANCES \\" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 12 | Lump sum price worked out by the contractor for \\"FOOTBALL/BASKETBALL/VOLLYBALL/HOCKEY/BADMINTON COURT/STAGE\\" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES |
| 13 | Lump sum price worked out by the contractor for \\"SIGN BOARD\\" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 14 | Lump sum price worked out by the contractor for \\"SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK\\" as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES |
| 15 | Sch 'A' Part-XV MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XV (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule). |
| 16 | INTERNAL WATER SUPPLYS&F 15 mm CP 2-in-1 stop cock/bib tap fancy type for fixing of health faucet or jet spray for the WC and complete all specified and as directed. |
| 17 | S&F Brass SS Jet Spray with 1 m pvc tube and complete all as specified and as directed. |
| 18 | INTERNAL ELECTRIFICATIONS&L Finolex's RG6 cable for TV point complete all as specified and directed |
| 19 | S&F of TV socket 1 module 230 volts AC complete all as specified and directed. |
| 20 | Supply and install, testing wall termination Telephone socket RJ-11all as specified and directed by Engr in Charge. |
| 21 | S&F blanking plates complete all as specified and directed. |
| 22 | S&F of lamp holder, including 9 watt LED Bulb insulated body with back plate suitable for batten fittings and complete all as specified and directed. |
| 23 | S&F for highbay light 70/80 watts complete all as specified and directed. |
| 24 | S & F LED bed side reading light fitting white/black powder coated housing with movable string, metalic base,complete with driver to operate on 240V AC 50 Hz, suitable for indoor application and complete all as specified and directed. |
| 25 | S&F Sheet metal enclosure distribution board VTPN,6 way, 415 volt, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers proper with pcc works complete all as specified and directed. |
| 26 | S&F Sheet metal enclosure distribution board VTPN,4 way, 415 volt, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers proper with pcc works complete all as specified and directed. |
| 27 | M&L for concealed flame proof point wiring (using red, black and green colour wires as colour coding for single phase circuit) for one light point complete with 1.50 Sqmm (nominal cross sectional area) FRLSH PVC insulated unsheathed and multistranded copper conductor cable 1100 V (ISI Marked) for main point and for continues as earth wire connected to earth dolly etc (Phase, neutral and earth wire) drawn through and including ERW steel rigid heavy duty stove enamelled conduit with all flame proof fittings and all accessories e.g pipe bend, union socket, elbow, connector, reducer, pipe hook etc for light/fan points including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using CM(1:3) complete all as specified and as directed by Engr-In-Charge. Note: (i) Two nos of light point circuits shall be controlled by one rotaty switch/MCB fixed in existing DB. (ii) Rotary Switches, junction box, MCB shall be measured and paid separately under appropriate item of this Sch. |
| 28 | Supply and fixing (Concealed in wall) factory made flameproof DB Duly painted, 4 way dust and vermin proof including operatin Knob, cable glands, earth bar, bus bar with all accessoreis and comprising of the followingincluding taking out old Unserviceable existing DB any type complete all as specified and as directed by Engr-In-Charge. (i) MCB B Curve, SPN 32 Amps, 10 KA-01 Nos (Incoming) (ii) MCB B Curve, SP 6 Amps, 10 KA-02 Nos (Outgoing). |
| 29 | SEWAGE DISPOSAL M&L for providing,laying,testing and commissioning of 150mm bore Double wall corrugated pipe(Remarks DWC) pipes of SN-8 Grade for sewer line as per IS- 14333,16098 (Parts) : 3013 below ground at requred depth including all jointing fixtures carriage,barricading,lighting arrangment, cutting of any type road etc.Complete all as specified & directed. |
| 30 | RCC conventional Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users all as specified and directed. |
| 31 | Soakage wells exc, in ordinary soil, foundation in PCC (1:3:6) , walls of honey combed and solid RCC slab in M-25 concrete, including intercepting chamber, screen chamber, Brick work in CM 1:4, RCC cover slab in M-25/RR masonary /filling with bricks bats, complete of size 2.40m dia x 3.00 deep all as specified and directed |
| 32 | EXTERNAL WATER SUPPLY Material and labour for horizontal boring under roads/path for insertion of pipes upto 80 mm bore by manual drilling complete all as specified and as directed. |
| 33 | M & L for construction of brick masonry vavle pit of internal dimension 900mmx900mmx900mm depth with sub class \\"B' bricks in cm (1:4) and 10 mm thick plastering in CM(1:4),PCC (1:4:8) type D2 (Using 40mm grade broken stone aggregate) as in foundation lean concrete PCC (1:3:6) type CI (Using 20mm grade broken stone aggregate ) as in bedding and copping MS frame with 40x40x6mm angle iron 3 mm thick MS sheet cover plate with locking arrangement, hinges and two coats of sythetic enamel paint over one coat of red oxide primer including preparation of surface three coats of white wash on plaster surface (exposed to view) including necessary excavation in soft loose soil returning filling in and removal of surplus soil to a distance not exceeding 50 m complete allas specified and directed. |
| 34 | Supply, install, testing and commissioning openwell Submersible pump set electric driven 415 V Three Phase, 50 Hz copper wound of capacity 10 HP with cast iron impeller and stailess steel shaft complete all as specified and directed. |
| 35 | Supply, install, commissioning and testing factory made (including CPRI type test certified manufacturer) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated copper bus bars 100 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & 2 mm inner and individual compartment for MCCB/MCB & volt/Amps meter.The complete feeder pillar box should be powder coated including connections between main bus bar to outgoing MCCB/MCB shall be carried out by copper busbar 63Amps and above MCCB & below 63Amps by 16 Sqmm copper cable. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. (Pump House)Incoming(a) MCCB 4 Pole, 415 V, Thermal Magnetic release,Adjustable type, 32 Amps with 25 KA rapturing capacity - 01 No.(b) Bus bar copper 100 Amps - 01 Set of 4(c) Digital Voltmeter with selector switch - 01 No.(d) Digital Ammeter with CTs, with selector switch - 01 No.(e) Indicator lamp for three phase and seletor switch complete as required(f) Onload change over switch 415 volt 4 pole of capacity 32 Amps Please Enable Macros to View BoQ information |
| 36 | Supply, install, commissioning and testing factory made (including CPRI type test certified manufacturer) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated copper bus bars 100 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & 2 mm inner and individual compartment for MCCB/MCB & volt/Amps meter.The complete feeder pillar box should be powder coated including connections between main bus bar to outgoing MCCB/MCB shall be carried out by copper busbar 63Amps and above MCCB & below 63Amps by 16 Sqmm copper cable. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. (Pump House)Incoming(a) MCCB 4 Pole, 415 V, Thermal Magnetic release,Adjustable type, 32 Amps with 25 KA rapturing capacity - 01 No.(b) Bus bar copper 100 Amps - 01 Set of 4(c) Digital Voltmeter with selector switch - 01 No.(d) Digital Ammeter with CTs, with selector switch - 01 No.(e) Indicator lamp for three phase and seletor switch complete as required(f) Onload change over switch 415 volt 4 pole of capacity 32 Amps Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer