Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #57376014

Tender For Provn Of Children School At Bharatpur Mil Station

Issued by Statutory Bodies & Commissions/Committees · Bharatpur, Rajasthan
Tender Value
10.13 Crore
Estimated cost
Bid Submission
10 Oct 2026
15 days left
EMD
9.80 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Children School At Bharatpur Mil Station

BOQ

Name of Work:- PROVN OF CHILDREN SCHOOL AT BHARATPUR MIL STATION
Sl. No. Item Description
1Lump sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
2Lump sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY \\" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
3Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
4Lump sum price worked out by the contractor for \\"ROAD, PATH AND CULVERT\\" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
5Lump sum price worked out by the contractor for \\"SEWAGE DISPOSAL\\" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
6Lump sum price worked out by the contractor for \\"AREA DRAINAGE \\" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
7Lump sum price worked out by the contractor for \\"COMPOUND WALL AND GATE\\" as listed in Schedule ‘A’ Part-VII\\" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
8Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
9Lump sum price worked out by the contractor for \\"EXTERNAL ELECTRIFICATION\\" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
10Lump sum price worked out by the contractor for \\"INTERNAL CONDUIT OF TV/CCTV\\" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
11Lump sum price worked out by the contractor for \\" SUMMER APPLIANCES \\" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
12Lump sum price worked out by the contractor for \\"FOOTBALL/BASKETBALL/VOLLYBALL/HOCKEY/BADMINTON COURT/STAGE\\" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
13Lump sum price worked out by the contractor for \\"SIGN BOARD\\" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
14Lump sum price worked out by the contractor for \\"SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK\\" as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
15Sch 'A' Part-XV MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XV (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule).
16INTERNAL WATER SUPPLYS&F 15 mm CP 2-in-1 stop cock/bib tap fancy type for fixing of health faucet or jet spray for the WC and complete all specified and as directed.
17S&F Brass SS Jet Spray with 1 m pvc tube and complete all as specified and as directed.
18INTERNAL ELECTRIFICATIONS&L Finolex's RG6 cable for TV point complete all as specified and directed
19S&F of TV socket 1 module 230 volts AC complete all as specified and directed.
20Supply and install, testing wall termination Telephone socket RJ-11all as specified and directed by Engr in Charge.
21S&F blanking plates complete all as specified and directed.
22S&F of lamp holder, including 9 watt LED Bulb insulated body with back plate suitable for batten fittings and complete all as specified and directed.
23S&F for highbay light 70/80 watts complete all as specified and directed.
24S & F LED bed side reading light fitting white/black powder coated housing with movable string, metalic base,complete with driver to operate on 240V AC 50 Hz, suitable for indoor application and complete all as specified and directed.
25S&F Sheet metal enclosure distribution board VTPN,6 way, 415 volt, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers proper with pcc works complete all as specified and directed.
26S&F Sheet metal enclosure distribution board VTPN,4 way, 415 volt, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & /MCCB DBs confirrming to IS-13032, IS-8632,BS5484 with min 200 Amp raiting copper bus bar and grouting, fixing on wall with nut bolts wasshers proper with pcc works complete all as specified and directed.
27M&L for concealed flame proof point wiring (using red, black and green colour wires as colour coding for single phase circuit) for one light point complete with 1.50 Sqmm (nominal cross sectional area) FRLSH PVC insulated unsheathed and multistranded copper conductor cable 1100 V (ISI Marked) for main point and for continues as earth wire connected to earth dolly etc (Phase, neutral and earth wire) drawn through and including ERW steel rigid heavy duty stove enamelled conduit with all flame proof fittings and all accessories e.g pipe bend, union socket, elbow, connector, reducer, pipe hook etc for light/fan points including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc by using CM(1:3) complete all as specified and as directed by Engr-In-Charge. Note: (i) Two nos of light point circuits shall be controlled by one rotaty switch/MCB fixed in existing DB. (ii) Rotary Switches, junction box, MCB shall be measured and paid separately under appropriate item of this Sch.
28Supply and fixing (Concealed in wall) factory made flameproof DB Duly painted, 4 way dust and vermin proof including operatin Knob, cable glands, earth bar, bus bar with all accessoreis and comprising of the followingincluding taking out old Unserviceable existing DB any type complete all as specified and as directed by Engr-In-Charge. (i) MCB B Curve, SPN 32 Amps, 10 KA-01 Nos (Incoming) (ii) MCB B Curve, SP 6 Amps, 10 KA-02 Nos (Outgoing).
29SEWAGE DISPOSAL M&L for providing,laying,testing and commissioning of 150mm bore Double wall corrugated pipe(Remarks DWC) pipes of SN-8 Grade for sewer line as per IS- 14333,16098 (Parts) : 3013 below ground at requred depth including all jointing fixtures carriage,barricading,lighting arrangment, cutting of any type road etc.Complete all as specified & directed.
30RCC conventional Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users all as specified and directed.
31Soakage wells exc, in ordinary soil, foundation in PCC (1:3:6) , walls of honey combed and solid RCC slab in M-25 concrete, including intercepting chamber, screen chamber, Brick work in CM 1:4, RCC cover slab in M-25/RR masonary /filling with bricks bats, complete of size 2.40m dia x 3.00 deep all as specified and directed
32EXTERNAL WATER SUPPLY Material and labour for horizontal boring under roads/path for insertion of pipes upto 80 mm bore by manual drilling complete all as specified and as directed.
33M & L for construction of brick masonry vavle pit of internal dimension 900mmx900mmx900mm depth with sub class \\"B' bricks in cm (1:4) and 10 mm thick plastering in CM(1:4),PCC (1:4:8) type D2 (Using 40mm grade broken stone aggregate) as in foundation lean concrete PCC (1:3:6) type CI (Using 20mm grade broken stone aggregate ) as in bedding and copping MS frame with 40x40x6mm angle iron 3 mm thick MS sheet cover plate with locking arrangement, hinges and two coats of sythetic enamel paint over one coat of red oxide primer including preparation of surface three coats of white wash on plaster surface (exposed to view) including necessary excavation in soft loose soil returning filling in and removal of surplus soil to a distance not exceeding 50 m complete allas specified and directed.
34Supply, install, testing and commissioning openwell Submersible pump set electric driven 415 V Three Phase, 50 Hz copper wound of capacity 10 HP with cast iron impeller and stailess steel shaft complete all as specified and directed.
35Supply, install, commissioning and testing factory made (including CPRI type test certified manufacturer) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated copper bus bars 100 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & 2 mm inner and individual compartment for MCCB/MCB & volt/Amps meter.The complete feeder pillar box should be powder coated including connections between main bus bar to outgoing MCCB/MCB shall be carried out by copper busbar 63Amps and above MCCB & below 63Amps by 16 Sqmm copper cable. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. (Pump House)Incoming(a) MCCB 4 Pole, 415 V, Thermal Magnetic release,Adjustable type, 32 Amps with 25 KA rapturing capacity - 01 No.(b) Bus bar copper 100 Amps - 01 Set of 4(c) Digital Voltmeter with selector switch - 01 No.(d) Digital Ammeter with CTs, with selector switch - 01 No.(e) Indicator lamp for three phase and seletor switch complete as required(f) Onload change over switch 415 volt 4 pole of capacity 32 Amps Please Enable Macros to View BoQ information
36Supply, install, commissioning and testing factory made (including CPRI type test certified manufacturer) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated copper bus bars 100 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & 2 mm inner and individual compartment for MCCB/MCB & volt/Amps meter.The complete feeder pillar box should be powder coated including connections between main bus bar to outgoing MCCB/MCB shall be carried out by copper busbar 63Amps and above MCCB & below 63Amps by 16 Sqmm copper cable. Front opening type with approx for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. (Pump House)Incoming(a) MCCB 4 Pole, 415 V, Thermal Magnetic release,Adjustable type, 32 Amps with 25 KA rapturing capacity - 01 No.(b) Bus bar copper 100 Amps - 01 Set of 4(c) Digital Voltmeter with selector switch - 01 No.(d) Digital Ammeter with CTs, with selector switch - 01 No.(e) Indicator lamp for three phase and seletor switch complete as required(f) Onload change over switch 415 volt 4 pole of capacity 32 Amps Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57376014
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10.13 Crore
LAST DATE 10-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Children School At Bharatpur Mil Station
Basic Detail
Tender No 80918/E8
Bidding Type Tender
Location
City Bharatpur
State Rajasthan
Key Dates
Publish Date 05 Sep 2026
Submission Date 10 Oct 2026
Open Date 12 Oct 2026
Finance
Tender Value 10.13 Crore
Tender Fee 3000
EMD 9.80 Lakhs
Exemption Available
Document List
80918_ArchDrg_merged.pdf
80918_StructuralDrg_merged.pdf
80918_TenderDocs_all_merged.pdf
8cbd94f6-b2e6-4f90-97dc-dae3d53330b3.html
BOQ_883222.xls
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Oct 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

80918_ArchDrg_merged.pdf

pdf

80918_StructuralDrg_merged.pdf

pdf

80918_TenderDocs_all_merged.pdf

html

8cbd94f6-b2e6-4f90-97dc-dae3d53330b3.html

xls

BOQ_883222.xls

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders