Project Description
Tender for Repair To Sewage Line, Chain Link Fencing, Security Compound Wall At Cgdhq-10 And 3U Det Under Ge C Bell Bay
BOQ
| Sl. No. | Item Description |
| 1 | M & L for cleaning the chocked soakage of manholes at any size and depth and removing scum sludges to a distance exc 250m and n.exc 500m and cleaning with fresh water by taking out carefully cover slabs and placed in position including setting the cover slab with CM (1:6) complete all as specified and as directed |
| 2 | M & L for cleaning of blocked CI pipe line 100 mm bore, carefully in between manholes using split bamboo, cleaning rod, binding wire etc and flush with fresh water and disposed off the sludge complete all as specified and as directed. |
| 3 | Description all as per Item No 2.00 here-in-before above but 150mm dia complete all as specified and as directed. |
| 4 | M & L for removing RCC cover slab of septic tanks of various capacities and taking out scum/sludges including foul water and collect the same in closed container and depositing in earth pit of sufficient size and depth in any type of soil within the defence land where directed by Engineer-in-Charge to a distance exc 500m and not exc 1.5m, returning and filling in earth in excavated pit after complete disposal of scum /sludges chamber inlet and outlet pipe, MS rungs, septic tank cleaning with fresh water and applying one coat of bituminous paint on steel surfaces such as MS rungs, handle, inlet and outlet pipes etc, and filling tank with fresh water upto level as directed placing the RCC cover slab in position and set in CM 1:6 including cleaning the sewage line from last manholes to septic tank complete all as specified and as directed. |
| 5 | M & L for removing of filter bed/ soakage well etc by removing the filter media into scum/ sludges in foul position n.exc. 1.5 m deep and getting out complete all as specified and as directed. |
| 6 | M & L for cleaning the blockage manually by rodding, pumping and removing the deposited sludge/solid/ liquid, materials outside MD land complete all as specified and as directed:- |
| 7 | (a) water closet any description including trap and CI pipe line upto first manhole complete all as specified and as directed. |
| 8 | (b) Floor trap/ Nahani trap including gully trap complete all as specified and as directed. |
| 9 | (c) pipe from gully trap upto first manhole complete all as specified and as directed. |
| 10 | Dismantling of cast iron or reinforced concrete drainpipes, jointed in cement mortar and taking out of trenches /walls of 100mm dia if required all as specified and directed. |
| 11 | Dismantling of cast iron or reinforced concrete drainpipes, jointed in cement mortar and taking out of trenches /walls of 150mm dia if required all as specified and directed. |
| 12 | S & F Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors of 100mm dia all as specified and directed. |
| 13 | S & F Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors of 150mm dia all as specified and directed. |
| 14 | S & F in repairs Bends (any radius), diminishing pieces or tapers 100mm (larger bore measured) all as specified and as directed. |
| 15 | S & F in repairs Bends (any radius), diminishing pieces or tapers 150mm (larger bore measured) all as specified and as directed. |
| 16 | S & F PVC (SWR) pipes, single socketed, in any length, with rubber rings 110mm dia complete all as specified and directed. |
| 17 | S & F PVC (SWR) bends of 110 radius complete all as specified and as directed. |
| 18 | S & F PVC (SWR) junctions single (Single T) equal or unequal, dia of bore 110 mm complete all as specified and directed by Engr-in-Charge. |
| 19 | S & F PVC (SWR) 'P'/ 'S' trap bore 110mm/100mm complete all as specified and directed by Engr-in-Charge. |
| 20 | M & L for concrete bed to drain pipes of 100mm dia in cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed |
| 21 | M & L for concrete bed to drain pipes of 150mm dia in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed |
| 22 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for such as cover slab of manholes and septic tank, etc, reinforcement cut as required to facilitate demolition complete all as specified and directed |
| 23 | M & L for pre-cast reinforced cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in cover slab for manholes in any position and set in CM (1:4) including necessary form work complete all as specified and as directed. Note : Reinforcement shall be measured and paid seperately. |
| 24 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 25 | Description all as per Item No 21.00 here-in-before above but upto 8mm dia complete all as specified and directed |
| 26 | Demolition of brickwork /stone or boulder masonry built in cement mortar complete all as specified and directed |
| 27 | M & L for precast cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and set in CM complete all as specified and directed. |
| 28 | Taking down cement plaster of any description on stone /brick walls etc including raking out joints hackinfg for key scrubbing down with water complete all as specified and directed. |
| 29 | M & L for rendering 15mm thick cement plaster in cement mortar 1:6 on stone masonry surfaces other than fair face, finished even and fair wthout using extra cement complete all as specified and as directed. |
| 30 | M & L for preparation of new surface of walls and applying two coat of cement base paint over a coat of chalk whiting primer complete all as specified and directed. |
| 31 | M & L for two coats of acrylic antifungal exterior grade paint over a coat of primer including preparation of wall surfaces complete all as specified and as directed. |
| 32 | M & L for reinforced cement concrete (nominal mix) (1:2:4) type B-1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 33 | M & L for use and waste of timber as in formwork to sides of pillars, posts, struts, piers, columns and stanchion complete all as specified and directed. |
| 34 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed. |
| 35 | S & F MS work as in fencing posts angle iron /Tee section, drilled and counter sunk for bolusters running bars, including embedding in concrete and scuring etc, post and struts in fencing including cuting tops to shape as directed, drilled holes, notching for wire, etc, flat iron fillets, (for securing wire mesh etc,) holding or riveting etc, and similar work confirming to Fe-290 Gde E-165 all as specified and as directed. |
| 36 | M & L for applying two coats of synthetic enamelled paint over a coat of red oxide primer including preparation of new steel surfaces of any description not otherwise described over 10cm width or girth complete all as specified and as directed. |
| 37 | Dismantling fencing wire mesh of any type in any position complete all as specified and as directed. |
| 38 | Supply only Chain MS Galvanised fencing of 10 gauge (3mm thick ) alongwith with 1mm PVC Cotting of 50 x 50mm mesh size all as specified and as directed. |
| 39 | Fixing only chain link fencing including line wire, any mesh size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and as directed. |
| 40 | S & F MS 10mm dia screwed bolt (machine made) hexagonal/ square heads at one end and sed the others, for screwd or both ends, each screwed and ends to be fitted with washers and one hexagonal/ square nut, not exceeding 10 cm long complete all as specified and as directed. |
| 41 | M & L for mild steel round bars of 10mm dia cut to length bent to shape if required as tie bars for fixing chain link fencing complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender