Tender For special Repair And Replacement Of Light Switch Gears Light Panels In Bldg No P-30/ A8 (Jco Living), Bldg No P-120 (Jco Mess) At 172 Inf (Ta) Madras, Cincan Land (Army), special Repairs Of Lt Panels And Allied Works At installation Baaz, C
Tender Overview
Project Description
Tender for special Repair And Replacement Of Light Switch Gears Light Panels In Bldg No P-30/ A8 (Jco Living), Bldg No P-120 (Jco Mess) At 172 Inf (Ta) Madras, Cincan Land (Army), special Repairs Of Lt Panels And Allied Works At installation Baaz, C Bell Bay Under Ge C Bell Bay
BOQ
| Sl. No. | Item Description |
| 1 | Taking down DB with MCBs/main switch of any size and making good disturbed surface of wall/floor complete all as specified and as directed. |
| 2 | Taking down carefully sub-main wiring of any description and making good the disturbed surfaces to match the existing complete all as specified and as directed. |
| 3 | M & L for sub main wiring (concealed) complete with two single core 6 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade ISI marked and conduit accessories including 6 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface inc taking out old existing wire and conduit all as specified and directed. Note: (i) 3 run of 6 Sqmm & one run of PVC conduit shall be measured as single unit(ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 4 | M & L for sub main wiring (concealed) complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade ISI marked and conduit accessories including 4 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface inc taking out old existing wire and conduit all as specified and directed. Note: (i) 3 run of 4 Sqmm & one run of PVC conduit shall be measured as single unit(ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 5 | Taking down carefully any type point wiring (light, fans, socket etc) complete including battens and fittings such as switch, ceiling rose, light fittings, regulators, socket, etc. and making good disturbed surface of wall/floor, etc. complete all as specified and as directed. |
| 6 | M & L for point wiring (concealed) on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 Sqmm (nominal area) multi stranded copper conductor cable drawn through in and including non metallic medium grade rigid PVC conduit heavy grade accessories, ISI marked, 20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes , switch plates of suitable make and 1.5 Sqmm copper earth continuity wire connected to earth dolly complete for the following: |
| 7 | One Light/ Fan point controlled by one switch complete all as specified and as directed. |
| 8 | One switch socket outlet modular type 3 pin 6 Amp on same board complete all as specified and as directed. |
| 9 | One switch socket outlet modular type 3 pin 6 Amp on independent board complete all as specified and as directed. |
| 10 | Description all as per item No 6.00 above but 2.5 Sqmm cable size and 2.5 Sqmm earth continuity wire for one 3 pin socket outlet, 16 Amps on independent board complete all as specified and as directed. |
| 11 | S & F switch modular type , single pole one way 6 Amps, 240 volts AC suitable for existing modular switch boxes without indicator, all as specified and as directed. |
| 12 | S & F socket modular type single pole one way 6 Amps 240 volts suitable for existing modular switch boxes all as specified and as directed. |
| 13 | S & F socket modular type 16 Amps, 3 pin combined multistandard, 2 module, 240 volts suitable for existing modular switch boxes all as specified and as directed. |
| 14 | S & F switch modular type 16 Amps, one way with indicator, 1 module, 240 volts suitable for existing modular switch boxes all as specified and as directed. |
| 15 | S & F 0-4 step, two module, modular type electronic regulator for ceiling fan 1200 mm sweep, 240 volts, 120 watts humfree single pole, all as specified and as directed. |
| 16 | S & F ceiling rose, surface bakelite, 65 x 50 mm, three terminals, ISI marked all as specified and as directed. |
| 17 | S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps all as specified and as directed. |
| 18 | S & F wall mounted LED 18/20 watts 6500 K with output of 1800 lumens , box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of suitable size from ceiling rose to fitting with integral LED tube 4' x 18 watts complete all as specified and as directed. |
| 19 | S & F Surface mounting 10 watt LED luminaires with epoxy white powder coated CRCA sheet steel housing with reeded translucent acrylic diffuser and 1 x 10 watt LED fitting including taking down old unserviceable fittings any type complete all as specified and as directed. |
| 20 | S & F LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. all as specified and as directed. |
| 21 | S & F LED building security lights 25 W IP 66 including 1.5mtr long GI bend pipe of suitable dia and all necessary accessories all as specified and as directed. |
| 22 | S & F energy efficient 5 star rating, BLDC motor, dust proof, ceiling fan 1200 mm sweep size, copper winding with minimum air delivery of 210 cu.mtr/min, A.C, single phase, 220 volt 50 Hz including canopy reel, flexible copper conductor fixing with necessary lugs drawn through flexible PVC conduit from ceiling rose, including necessary hook, rubber bush & safety pin all necessary accessories including removal of old ceiling fan and deposit to E/M sub division storeyard complete all as specified and as directed. |
| 23 | S & F exhaust fan, steel body AC single phase 230 V of size 300mm sweep with blades, frame and louver including making of holes if required for exhaust fan alongwith removal of old exhaust fan and deposit to E/M sub division storeyard all as specified and as directed. |
| 24 | S & F sheet metal enclosures for TPN DB's with metal double door for incorporating MCBs, IP-43, 8 way with 200 Amps rated busbar, 240 volts, as per IS-8623 all as specified and as directed. |
| 25 | S & F MCB TPN, 40 Amps, breaking capacity 10 KA 'C' curve confirming to IS/ IEC 60898-1 2002, integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 Hz including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc., all as specified and as directed. |
| 26 | S & F sheet metal enclosures for SPN DB's with metal double door for incorporating MCBs, IP-43, 8 way with 200 Amps rated busbar, 240 volts, as per IS-8623 all as specified and as directed. |
| 27 | S & F MCB SPN, 32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/ IEC 60898-1 2002, integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 Hz including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc., all as specified and as directed. |
| 28 | S & F MCB SP 6-32 Amps, breaking capacity 10 KA 'C' curve confirming to IS/IEC 60898-1 2002, integrated label holder, sliding bottom clamp , IP 20 protected terminal, sliding shutters, 240 volts, 50 Hz including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc.,all as specified and as directed. |
| 29 | M & L for Earthing complete with galvanised steel plate electrode, 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in plate No. 3 of SSR (Part I) of 2009 to the earthing test point inc testing on completion all as specified and as directed. Note :- (i) The cost of excavation and earth work PCC pit and RCC cover funnel & watering pipe, wiremesh, charcoal dust and common salt earth lead protection pipe upto 7.5 Rmt shall be deemed included in the unit rate for earthing (ii) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost |
| 30 | Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 31 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil all as specified and as directed. |
| 32 | Removing excavated materials (soil) to a distance not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and as directed. |
| 33 | S & L XLPE insulated, armoured, heavy duty, electric cable of size 3.5 Core x 95 Sqmm with stranded aluminium conductors, 1100 volts grade, laid in trenches / fixing on wall / poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, with GI protections pipes, complete all as specified and as directed. |
| 34 | S & L XLPE insulated, armoured, heavy duty, electric cable of size 3.5 Core x 35 Sqmm with stranded aluminium conductors, 1100 volts grade, laid in trenches/ fixing on wall/ poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion, with GI protections pipes, complete all as specified and as directed. |
| 35 | S & F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having outer dia 100 mm complete terminated up to termination end point complete all as directed by Engr-in-Charge. |
| 36 | S & F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having outer dia 50 mm complete terminated up to termination end point complete all as directed by Engr-in-Charge. |
| 37 | Supply, install testing and commissioning weather and vermin proof Outdoor type L.T. Panel board (Near Galley) factory fabricated indoor cubicle/ kiosk type totally enclosed IP 54 made out of 3.15 mm thick CRCA sheet metal enclosure of suitable size, with angle iron frame of M.S. angle 50 x 50 x 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber / wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour, including connecting with L.T. armoured incoming and outgoing cables and including required sizes of cable lugs of aluminum complete all as specified and directed and consisting of following :- |
| 38 | (a) Copper bus bar 400 Amps for 3 phase & neutral(b) MCCB 4 pole 250 Amp 36 KA 415 V- 1 No as Incoming(c) MCCB 4 pole 160 Amp 36 KA 415 V- 02 Nos as Outgoing(d) MCCB 4 pole 100 Amp 36 KA 415 V - 02 Nos. (01 No. as Outgoing and 01 No. as Spare)(e) MCCB 4 Pole 63 Amps 16 KA 415 V - 02 Nos (01 No. as Outgoing and 01 No as Spare)(f) Digital Volt meter (0-500 V) with selector switch(g) Digital Ammeter CT operated 0 to 500 Amp with phase selector switch(h) Indicator lamp (RYB) - 3 Nos(i) Blank Space for Mounting of MCCB - 01 No. |
| 39 | Supply, install testing and commissioning of weather and vermin proof Outdoor type L.T. Panel board (Near MT) factory fabricated indoor cubicle/ kiosk type totally enclosed IP 54 made out of 3.15 mm thick CRCA sheet metal enclosure of suitable size, with angle iron frame of M.S. angle 50 x 50 x 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber/ wooden bushes to prevent ingress of water/ vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour, including connecting with L.T. armoured incoming and outgoing cables and including required sizes of cable lugs of aluminum complete all as specified and directed and consisting of following :- |
| 40 | (a) Copper bus bar 400 Amps for 3 phase & neutral(b) MCCB 4 pole 250 Amp 36 KA 415 V- 1 No as Incoming(c) MCCB 4 pole 160 Amp 36 KA 415 V- 01 No as Outgoing(d) MCCB 4 pole 125 Amp 36 KA 415 V- 01 No as Outgoing(e) MCB 4 Pole 40 Amps 10 KA 415 V - 01 No as Outgoing(f) Digital Volt meter (0-500 V) with selector switch(g) Digital Ammeter CT operated 0 to 500 Amp with phase selector switch(h) Indicator lamp (RYB) - 3 Nos(j) Blank Space for Mounting of MCCB - 01 No. Please Enable Macros to View BoQ information |
| 41 | (a) Copper bus bar 400 Amps for 3 phase & neutral(b) MCCB 4 pole 250 Amp 36 KA 415 V- 1 No as Incoming(c) MCCB 4 pole 160 Amp 36 KA 415 V- 01 No as Outgoing(d) MCCB 4 pole 125 Amp 36 KA 415 V- 01 No as Outgoing(e) MCB 4 Pole 40 Amps 10 KA 415 V - 01 No as Outgoing(f) Digital Volt meter (0-500 V) with selector switch(g) Digital Ammeter CT operated 0 to 500 Amp with phase selector switch(h) Indicator lamp (RYB) - 3 Nos(j) Blank Space for Mounting of MCCB - 01 No. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender