Defence Statutory Bodies & Commissions/Committees Closing in 7 days TDR #57375968

Tender For Repair/ Replacement And Maintenance Of Lt Switch Gears Lt Panels Apfc Panels, Lt Cables And Connected Allied Work At Cdm Under Age No I Of Ge(U) Secunderabad.

Issued by Statutory Bodies & Commissions/Committees · Hyderabad, Telangana
Tender Value
49 Lakhs
Estimated cost
Bid Submission
29 Sep 2026
7 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement And Maintenance Of Lt Switch Gears Lt Panels Apfc Panels, Lt Cables And Connected Allied Work At Cdm Under Age No I Of Ge(U) Secunderabad.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Sep-2026 BOQ Corrigendum BOQ 29-Sep-2026
2 18-Sep-2026 Date Corrigendum Date 29-Sep-2026

BOQ

Name of Work:- REPAIR/ REPLACEMENT AND MAINTENANCE OF LT SWITCH GEARS LT PANELS APFC PANELS, LT CABLES AND CONNECTED ALLIED WORK AT CDM UNDER AGE NO I OF GE(U) SECUNDERABAD.
Sl. No. Item Description
1Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 600 Amps rating for phase and neutral 4 strips with colour
2coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
3On load Change Over switch of capacity 400 Amps with 2 incoming and one outgoing -01 nos
4On load Change Over switch of capacity 200 Amps with 2 incoming and one outgoing -01 nos
5MCCB 4pole, 400 Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
6MCCB 4pole, 315 Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
7MCCB 4pole, 250 Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 03 No (Outgoing)
8MCCB 4pole, 100 Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 02 No (Outgoing)
9Digital Ammeter 0 to 500Amps with selector switch- 01 No and 3 No of CT coil ratio 800:5 - 01 Set
10Digital Voltmeter 0-500Volts with selector switch, 7 position and 2A HRC fuses/MCBs - 1Set
11Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
12Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 800 Amps rating for phase and neutral 4 strips with colour
13coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
14MCCB 4pole, 315 Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
15MCCB 4pole, 100 Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 03 No (Outgoing)
16MCCB 4pole, 63 Amps, with adjustable thermal and magnetic settings, 16KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 03 No (Outgoing)
17Digital Ammeter 0 to 400Amps with selector switch- 01 No and 3 No of CT coil ratio 800:5 - 01 Set
18Digital Voltmeter 0-500Volts with selector switch, 7 position and 2A HRC fuses/MCBs - 1Set
19Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
20Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 500 Amps rating for phase and neutral 4 strips with colour
21coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
22On load Change Over switch of capacity 400 Amps with 2 incoming and one outgoing -01 nos
23MCCB 4pole, 400 Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415lt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
24MCCB 4pole, 250 Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 02 No (Outgoing)
25MCCB 4pole, 125 Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 03 No (Outgoing)
26Digital Ammeter 0 to 500 Amps with selector switch- 01 No and 3 No of CT coil ratio 800:5 - 01 Set
27Digital Voltmeter 0-500Volts with selector switch, 7 position and 2A HRC fuses/MCBs - 1Set
28Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
29Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4 wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 300 Amps rating for phase and neutral 4 strips with colour
30coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
31Onload Change Over switch of capacity 250 Amps with 2 incoming and one outgoing -01 nos
32MCCB 4pole, 250 Amps, with adjustable thermal and magnetic settings, 25 KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
33MCCB 4pole, 63 Amps, with adjustable thermal and magnetic settings, 16KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 05 No (Outgoing)
34Digital Ammeter 0 to 300 Amps with selector switch- 01 No and 3 No of CT coil ratio 800:5 - 01 Set
35Digital Voltmeter 0-500Volts with selector switch, 7 position and 2A HRC fuses/MCBs - 1Set
36Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
37Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 300 Amps rating for phase and neutral 4 strips with colour
38coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
39MCCB 4pole, 200 Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
40MCCB 4pole, 100 Amps, with adjustable thermal and magnetic settings, 25KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 05 No (Outgoing)
41Digital Ammeter 0 to 250 Amps with selector switch- 01 No and 3 No of CT coil ratio 800:5 - 01 Set
42Digital Voltmeter 0-500Volts with selector switch, 7 position and 2A HRC fuses/MCBs - 1Set
43Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
44Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 800 Amps rating for phase and neutral 4 strips with colour
45coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
46MCCB 4pole, 630 Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
47MCCB 4pole, 400 Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
48MCCB 4pole, 250 Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
49MCCB 4pole, 200 Amps, with adjustable thermal and magnetic settings, 36KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 02 No (Outgoing)
50Digital Ammeter 0 to 800 Amps with selector switch- 01 No and 3 No of CT coil ratio 800:5 - 01 Set
51Digital Voltmeter 0-500Volts with selector switch, 7 position and 2A HRC fuses/MCBs - 1Set
52Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
53Supply, Install, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, dust and vermin proof, free standing floor mounting type mounted on floor, separate cable alley for all the feeders, suitable for 440Volts, 3 Phase 4wire 50Hz AC supply system, conforming to IS, IP-54 class protection and made of 3mm CRCA mild steel sheet & angle iron frame, compartmentalized with rubber gasket hinged doors, front & rear opening and locking arrangement (including provision of 65mm Godrej (freedom) lock with 2 keys) with necessary bus bar arrangement with electrolytic grade aluminium bus bar 1000 Amps rating for phase and neutral 4 strips with colour
54coded PVC sleeves, installed on epoxy insulators housed in separate bus chambers covered with heat shrinkable sleeves with necessary bus bar tapings for MCCBs, copper control wiring of required size for instruments and duly powder coated on the outside and inside including air ventilation for heat dissipation, suitable size knock out holes for cable glands, necessary earthwork excavation and provision of PCC platform 100mm thick with PCC 1:2:4 type B-2 using 40mm graded stone aggregate one meter around the panel board, cable gland and lugs for incoming and outgoing cable etc., independent multilayer chambers to accommodate complete all as specified and directed including the following accessories :-
55On load Change Over switch of capacity 800 Amps with 2 incoming and one outgoing -01 nos
56ACB 4pole, 800 Amps, with adjustable thermal and magnetic settings, 50KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Incoming)
57MCCB 4pole, 200 Amps, with adjustable thermal and magnetic settings, 35KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 02 No (Outgoing)
58MCCB 4pole,160 Amps, with adjustable thermal and magnetic settings, 35KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 01 No (Outgoing)
59MCCB 4pole, 100 Amps, with adjustable thermal and magnetic settings, 35KA rupturing capacity at 415volt, conform to IEC -60947-II/ IS-13947-II - 02 No (Outgoing)
60Digital Ammeter 0 to 1000Amps with selector switch- 01 No and 3 No of CT coil ratio 800:5 - 01 Set
61Digital Voltmeter 0-500Volts with selector switch, 7 position and 2A HRC fuses/MCBs - 1Set
62Indicator lamp R,Y,B LED type with 3 Nos of 2A HRC fuses - 01 Set
63Repair and maintenance of LT Panel of any capacity complete, including site inspection, shutdown, dismantling of damaged components, cleaning of panel, replacement/repair/Refixing of breakers, contactors, relays, meters, bus bars, insulators, control wiring, cable terminations and earthing connections as required, rust removal, painting, construction/repair of RCC foundation with excavation, PCC, grouting and fixing of foundation channels, reinstallation and alignment of panel as required, testing of insulation resistance, continuity, protection and control circuits, commissioning, trial operation under load, and all labour, materials, tools, tackles, transportation and incidental works required for satisfactory completion of the work as directed by the Engineer-in-Charge.
64S&F in repairs Weather proof outdoor bus bar chamber made out of 3mm thick MS sheet comprising MCCB 4pole 125 Amps 25KA capacity thermal and magnetic setting as incomer and 4 Nos aluminium strips each of 200 Amps as outgoing , 90cm long duly insulated mounted on insulators with 4 No’s mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers, cable glands at entry and outlet points and excavation, earth work, returning filling in and removal of surplus soils including taking out old unserviceable bus bar chamber complete all as specified and directed.
65M&L for replacement of Synthetic insulating mat of size 2m x 1m x 2.5 mm complete all as specified & directed by Engineer-in-charge.
66M&L MS Chequered plate of thickness 5 mm as per site requirement sizes to cover cable duct openings including repairing works to edges of Duct to place MS Chequered plate equally on the duct in the installations complete including taking out the broken PCC duct covers duct covers all as specified & directed by Engineer-in-charge.
67Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying cable at and getting out in soft/loose soil all as specified and directed.
68Excavating in trenches, n exc 1.5 m wide and exceeding 1.5 m not exceeding 3 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc.n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard / Dense soil complete all as specified.
69Returning, filling in soil including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick all as specified and directed
70Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point all as specified
71Supply and spread sand in trenches for cable cushioning including watering and consolidation all as specified Note : For the purpose of payment punned thickness only will be measured.
72Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed.
73Supplying, laying, jointing, testing and commissioning 1100 volts grade, LT XLPE insulated, PVC sheathed as per IS-7098 (Part-I), 1988 galvanized steel strip or wire armoured, heavy duty, electric cables, with multistranded aluminium conductor laid in trenches/ passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including taking down unserviceable cable complete all as specified and directed.Note : Earthwork Excavation, sand cushioning GI pipe and cable protection will be measured and paid separately.
74All as per item No.18.00 above 3.5 core 185 Sqmm
75All as per item No.18.00 above 3.5 core 150 Sqmm
76All as per item No.18.00 above 3.5 core 120 Sqmm
77All as per item No.18.00 above 3.5 core 95 Sqmm
78All as per item No.18.00 above 3.5 core 70 Sqmm
79All as per item No.18.00 above 3.5 core 50 Sqmm
80All as per item No.18.00 above 3.5 core 35 Sqmm
81All as per item No.18.00 above 3.5 core 25 Sqmm
82All as per item No.18.00 above 4 core 16 Sqmm
83Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 Mpa working pressure.
84Disconnecting electric supply and removing burnout/unserviceable cable jointing kit, supply and jointing new straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm for 1.1 KV (Earthed ) grade including testing complete all as specified and directed.
85All as per item No.20.00 above but cable of size 70 Sqmm to 120 Sqmm
86All as per item No.20.00 above but cable of size 150 Sqmm to 185 Sqmm
87S&F in repair, sheet metal enclosure with 63 amps 3 pole and neutral socket and plug top with MCCB complete all as specified and directed by Engr-in-charge.
88S&F in repair, sheet metal enclosure with 32 amps 3 pole and neutral socket and plug top with MCCB complete all as specified and directed by Engr-in-charge.
89S&F in repairs, 3pole 63Amp MCCB, 16KA rupturing capacity at 415volt with adjustable thermal and magnetic settings, conform to IEC -60947-II/ IS-13947-II complete all as specified.
90S&F in repairs, 3pole 125Amp MCCB, 16KA rupturing capacity at 415volt with adjustable thermal and magnetic settings, conform to IEC -60947-II/ IS-13947-II complete all as specified.
91S&F in repairs, 4pole 160Amp MCCB, 36KA rupturing capacity at 415volt with adjustable thermal and magnetic settings, conform to IEC -60947-II/ IS-13947-II complete all as specified.
92S&F in repairs, 3pole 200Amp MCCB, 36KA rupturing capacity at 415volt with adjustable thermal and magnetic settings, conform to IEC -60947-II/ IS-13947-II complete all as specified.
93S&F in repairs, 4pole 200Amp MCCB, 36KA rupturing capacity at 415volt with adjustable thermal and magnetic settings, conform to IEC -60947-II/ IS-13947-II complete all as specified.
94S&F in repairs, 3pole 250Amp MCCB, 36KA rupturing capacity at 415volt with adjustable thermal and magnetic settings, conform to IEC -60947-II/ IS-13947-II complete all as specified.
95S&F in repairs, 4pole 250Amp MCCB, 36KA rupturing capacity at 415volt with adjustable thermal and magnetic settings, conform to IEC -60947-II/ IS-13947-II complete all as specified.
96S&F in repairs, 4pole 400Amp MCCB, 36KA rupturing capacity at 415volt with adjustable thermal and magnetic settings, conform to IEC -60947-II/ IS-13947-II complete all as specified.
97S&F in repairs, 4pole 630Amp MCCB, 50KA rupturing capacity at 415volt with adjustable thermal and magnetic settings, conform to IEC -60947-II/ IS-13947-II complete all as specified.
98S&F in repairs 40mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed.
99S&F in repairs 50mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed.
100S&F in repairs 80mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed.
101Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 meters long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed.Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
102M&L for PCC 1:3:6 type C2 (40mm graded aggregates) as in foundation, filling and mass concrete complete all as specified.
103M&L for cement concrete 1:3:6 type C-1 using 20mm graded stone aggregates as in coping / pedestal of poles including necessary formwork complete all as specified.
104in repair/ replacement Supply, fabrication, and fixing of a circular ring arrangement for flood light mounting on a 11m high GI tubular pole, comprising a 600 mm diameter outer ring fabricated from 50 mm dia medium class MS pipe (IS:1239), reinforced with 4 spoke-type supports made of 25 mm dia MS pipe, all welded to a central hub ring of suitable dia for fix on pole .The central hub is mounted on the pole top using a fabricated MS base plate with GI U-bolts, nuts, and washers for firm attachment.The ring shall be provided with 4 equidistantly spaced flood light mounting arms made from 25 mm × 6 mm MS flats or angles, each approximately 250–300 mm long, with drilled 12 mm holes to accommodate bolt-on LED flood lights of 100–150 W rating.All MS components shall be thoroughly cleaned, given one coat of red oxide primer, and finished with two coats of weather-resistant black enamel paint.The entire assembly shall be installed securely at the pole top with proper alignment, ensuring structural stability and safe mounting of flood lights complete all as specified and directed.
105Supply and laying in trenches of 63 mm dia DWC HDPE pipe on repairs, Heavy Duty, conforming to IS 16205 Part 24, made of HDPE, with corrugated outer wall and smooth inner bore, suitable for passing 11 kV, 3C x 95 sqmm XLPE cable, including cost of couplers, jointing accessories, end caps, and laying as per site requirement and engineer-in-charge direction.
106Supply and laying in trenches of 40 mm dia DWC HDPE pipe repairs, , Heavy Duty, conforming to 16205 Part 24, made of HDPE, with corrugated outer wall and smooth inner bore, suitable for passing 11 kV, 3C x 95 sqmm XLPE cable, including cost of couplers, jointing accessories, end caps, and laying as per site requirement and engineer-in-charge direction.
107Supply and fix, Street light control junction box 230 x 170 x 105mm up to 25Sqmm 3.5/4 core cables made out of FRP sheet moulded and arrangement for incoming and outgoing 3 phase 4 wire system with R,Y,B & N studs and control for incoming and outgoing cables with MCB SP 10Amp 230 volts with neutral link including pole mounting kit , completed all as specified and directed.
108Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor cable of size 3 core 4 sq mm served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed 4 sq mm 3 core in service connections complete all as specified and directed.
109M&L for pole painting by applying two coats of aluminium paint over a coat of red oxide primer and writing of MES No on pole with emulsion black paint complete all as specified and directed.
110M&L, Stickering of any type of street light pole with A1 graded radium strip of 50.8 mm width three colour red, white and green around the pole with 100mm gap in each strip at a distance of 1.1 meter high from the ground level complete all as directed.
111M&L in repairs, Earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to GI strip 25x4mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No.3 of SSR Part-I including testing on completion complete all as specified and directed by Engr-in-charge.Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 40mm dia and wire mesh complete in addition to item No.1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No.422 of SSR Part-II. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57375968
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 29-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement And Maintenance Of Lt Switch Gears Lt Panels Apfc Panels, Lt Cables And Connected Allied Work At Cdm Under Age No I Of Ge(U) Secunderabad.
Basic Detail
Tender No GE (U)/SEC/TOKEN/M55 OF 2026-27
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 18 Sep 2026
Submission Date 29 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
91fa03d5-ef9c-4329-9df6-65c4f175bc93.html
BOQ_883258.xls
M55_8661_Tender.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Sep 29, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

91fa03d5-ef9c-4329-9df6-65c4f175bc93.html

xls

BOQ_883258.xls

pdf

M55_8661_Tender.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders