Tender For Provn Of 125 Kva Dg Set For Integrated Medical Station (Ims) At installation Baaz, C Bell Bay Under Ge C Bell Bay.
Tender Value
43.50 Lakhs
Estimated cost
Bid Submission
28 Sep 2026
12 days left
EMD
87000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nicobars → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of 125 Kva Dg Set For Integrated Medical Station (Ims) At installation Baaz, C Bell Bay Under Ge C Bell Bay.
BOQ
| Sl. No. | Item Description |
| 1 | B/R PORTION :Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and as directed. |
| 2 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and as directed. |
| 3 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 5 | Removing excavated material (soil) to a distance n.exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and as directed. |
| 6 | M & L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. |
| 7 | M & L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. |
| 8 | M & L for RCC M-30 (Design Mix) (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and as directed. |
| 9 | M & L for mild steel TMT reinforcement bars of 10 mm dia and over, cut to length, bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clip all as specified and directed. |
| 10 | Description all as per Item No 9.00 above but 6mm dia and over upto and including 10mm dia as in stirrups, spacers and bindres all as specified and directed. |
| 11 | M & L for use and waste of timber as in formwork to sides of concrete foundations, footings, bases of columns raft and raft beams sides and soffits of foundation and plinth beam and similar work vertical or to batter all as specified and as directed. |
| 12 | M & L for Pre-cast cement concrete block masonry type C-1, (1:3:6), (using 20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and directed. |
| 13 | M & L for hard core of gauge n.exc 63 mm , with broken stone or boulders , deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface all as specified and as directed. |
| 14 | M & L for 100 mm thick PCC (1:4:8) type D-2, (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 15 | M & L for 40mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in floor finished even and smooth without using extra cement complete all as specified and as directed. |
| 16 | M & L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement all as specified and as directed. |
| 17 | M & L for rendering 15 mm thick in cement plaster (1:4) on fair faces of concrete surfaces surface finished fair and even mixed with WPC as per manufacturer's instructions complete all as specified and directed. (Note : Supply only of WPC shall be measured and paid separately). |
| 18 | Supply only of integral waterproofing compound of approved make all as specified and as directed. |
| 19 | M & L for preparation of newly plastered or unplastered surfaces of walls and applying two coat of distemper oil emulsion white tinted over a coat of alkali resistant primer complete all as specified and as directed. |
| 20 | M & L for finishing walls with acrylic smooth exterior paint of required shade (two or more coats applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 Sqm) all as specified and directed. |
| 21 | S & F for steel work in columns, plates, tubular trusses including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 etc complete all as specified and directed. |
| 22 | S & F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength of 550 MPa as in roof covering /cladding to wall, fixed with self tapping screws as specified and as directed. |
| 23 | S & F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering /cladding to wall, fixed with self tapping screws as specified and as directed. |
| 24 | M & L for applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 25 | M & L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection / path etc (75 mm thick) finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
| 26 | E/M PORTION :Supply, install, testing & commissioning of silent diesel engine driven generating set of 125 KVA with AMF panel developing 156 HP @ 1500 RPM, four cylinder, vertical water cooled diesel oil engine directly coupled with AC alternator, 415 volts, 3 phase 4 wire, 50 Hz @ 0.8 P.F self excited, self regulated designed to run at 1500 RPM with acoustic enclosure (sound proof) as per Central Pollution Control Board (CPCB-IV) approved DG set as per IS:10001/10002 and alternator as per IS: 13364 complete with foundation (as per OEM design), control panel with necessary meter and all other necessary accessories as follows: |
| 27 | (A) Diesel Engine : (a) Radiator with blower fan or heat exchanger with guard(b) Pipe coupling for engine cooling system piping(c) Corrosion inhibitor coolant(d) Paper element filters(i) Fuel filter.(ii) Lube oil filter.(iii) By pass filter(e) Fly wheel housing and fly wheel to suit alternator(f) Engine bearing mechanism in fly wheel housing(g) Shut off coil with safeties for LLOP/HWT/over speed(h) Dry type air cleaners and vaccum indicators(j) Residential silencers(k) Stainless Steel exhaust flexible bellows(l) Motor driven priming pump(m) Battery charging alternator(n) Exhaust piping made out of STIC C class , MS pipe inclusive of all accessories and hardware, necessary support scaffolding as per manufacturer's recommondations to sustain back pressure with rain cap.(o) Mineral wool insulation 50mm thick suitable for 400 degree celcius temperature cladded with aluminium sheet of 30 gauge for the entire length of exhaust pipe(p) First fill of engine oil, coolant and diesel during commissioning and 12 hours testing(q) Inter connecting copper cabling of adequate capacity between batteries control(r) Fuel pipe C class STIC 25mm/ 40mm / 50mm dia - 01 lot(s) Self starter 12 volt, D.C.(t) Mechanical governor(u) Fuel injection pump |
| 28 | (v) Electronic micro processor standard control instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) Battery voltage (ii) Water temperature (iii) Lubricating oil pressure (iv) Engine speed (v) Engine hours run (vi) Frequency (vii) Voltage(w) Safety control ( Trip and indication ) (i) High water temperature (ii) Low tube oil pressure (iii) Overspeed stop(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alongwith AVM pads(y) Battery 12 Volt, 180 AH, 01 No, maintenance free with leads and terminals as per manufacturer recommendations |
| 29 | (B) ALTERNATOR: 125 KVA at 0.8 PF, 415 Volt, 3 Phase, 4 wire, 50 Hz, at 1500 RPM, Self excited and self regulated with AVR brushless excitation, screen protected, drip proof, Insulation class H, IP-23, self ventilated and conforming to BS : 5000 / IS: 4722 suitable for engine as mentioned here-in-before(C) Accoustic Enclosure : Accoustic enclosure for the above 125 KVA DG Set to reduce noise level to 75 dB measured at 1.0 metre distance for audible frequencies as per guidelines of Central Pollution Control Board of suitable size as recommended by authorised OEMs of Gen Set manufacturer's and comprising of following:-(i) Digital load manager : Three phase 4 wire indicating V, I, PF, KVA, KW, F of Enercon Make with serial communication port Model No EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase - 01 No.(ii) Indication LED lamps R,Y,B all as directed(iii) Bottom gland plate for incoming and outgoing cable(iv) Circuit diagram plateNote :(a) The DG set with accoustic shall be factory assembled by OEM of DG set manufacturer and make of alternator and deisel engine shall be got approved from Accepting Officer before procurement(b) The rates quoted are deemed to include all foundation work and AVM pads for DG set as per manufacturer recommendations and cost of oil, diesel, consumables etc required fot 12 hours testing of DG set |
| 30 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185.0 Sqmm 3.5 core complete all as specified and as directed. |
| 31 | S&F of HDPE double wall corrugated pipe confirming to IS -14930 Part with IP protection IP-67 having inner dia 100 mm complete terminated up to termination end point complete all as directed by Engr-in-Charge. |
| 32 | Excavation in trenches n.exc 1.5 meter wide and n.exc 1.5m in depth for laying of cables and getting out in hard/ dense soil all as specified and as directed. |
| 33 | M & L for busbar chamber made out of 3.15 mm thick MS sheet of size 450mm x 300mm x 450mm with angle iron frame of M.S. angle with hinged panel doors (covers) on one side with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/ rubber /wooden bushes to prevent ingress of water/ vermin etc., inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with aluminium busbar of rating 400 Amps including connecting with L.T. armoured incoming and outgoing cables with required sizes of cable lugs of aluminum complete all as specified and directed |
| 34 | M & L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead using galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and as directed. Note :- (i) The cost of excavation and earth work PCC pit and RCC cover funnel & watering pipe, wiremesh, charcoal dust and common salt earth lead protection pipe shall be deemed included in the unit rate.(ii) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender