Tender For Repairs/ Maintenance Of Building Security Lights, Mcb, Db And Other Connected Items At Mcb, Db And Other Connected Items At Md/ Otm Area Under Ge (West) Colaba, Mumbai.
Tender Overview
Project Description
Tender for Repairs/ Maintenance Of Building Security Lights, Mcb, Db And Other Connected Items At Mcb, Db And Other Connected Items At Md/ Otm Area Under Ge (West) Colaba, Mumbai.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-Sep-2026 | CORRIGENDUM NO.1 | Other | 22-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | S&F LED building security light fitting 45 Watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minimum 100 luman per watt after all losses, pressure die-cast aluminium housing LED Street light complete with GI clamp including connected accessories and bracket made of GI pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers all as directed by Engineer-in-Charge. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 2 | S&F LED building security light fitting 60 Watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minimum 100 luman per watt after all losses, pressure die-cast aluminium housing LED Street light complete with GI clamp including connected accessories and bracket made of GI Pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers all as directed by Engineer-in-Charge. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 3 | S&F LED intelligent smart sensor based auto dimmable LED building security light fittings with brightening / dimming options of 30 % to 100 % of the rated wattage on sensing of movement / occupancy, with in 8 meter radius fitting of capacity 45 watt, luminaire fixture in IP 66 protection level with aluminium pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 120 luman per watt after all losses, protection against biological eye safety certification and UV, and including suitable bracket MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers complete all as specified and directed.Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 4 | S&F LED intelligent smart sensor based auto dimmable LED building security light fittings with brightening / dimming options of 30 % to 100 % of the rated wattage on sensing of movement / occupancy, within 8 meter radius fitting of capacity 60 watt, luminaire fixture in IP 66 protection level with aluminium pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 120 luman per watt after all losses, protection against biological eye safety certification and UV, and including suitable bracket MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers complete all as specified and directed.Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 5 | Supply and fixing Solar street/ Bldg Security light 40 watt with 3 meter pole sensor based auto dimmable LED street lights warm / warm white fitting with built in Dynamic Power Saving Device - DPSD that automatically switches off to 50% of the rated wattage on pre-set time interval of capacity 45 watt, luminaire fixture in IP 66 protection level with aluminium pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 100 luman per watt after all losses, protection against biological eye safety certification and UV, and including suitable bracket MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers, warm / warm white and including suitable bracket MS clamps, complete all as specified and directed. |
| 6 | Supply and fix LED street light fitting of capacity 90 watt, luminaire fixture in IP 66 protection level with aluminium pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 100 luman per watt after all losses, protection against biological eye safety certification and UV, and including suitable bracket MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers complete all as specified and directed. Note: Contractor should arrange all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 7 | Supply and fix LED flood light fitting of capacity 200 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket and fixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirement on site complete all as specified and directed. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 8 | Supply and fix LED flood light fitting of capacity 150 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket and fixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirement on site complete all as specified and directed. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 9 | Supply and fix LED flood light fitting of capacity 100 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket and fixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirement on site complete all as specified and directed. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 10 | Supply and fix LED flood light fitting of capacity 50 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket and fixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirement on site complete all as specified and directed. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 11 | Taking down old unserviceable building security light/ street light/ flood light fitting of any type and any capacity and remove from its location complete all as specified and directed. |
| 12 | Supply and fixing in repairs LED inverter Batten 18 watt works warm / warm white on AC supply in normal mode and DC supply in inverter mode with inbuilt battery back up of upto 4 hours, high efficilceeiny, high lumes output, including taking out old fittings, complete all as specified and directed. |
| 13 | M&L for point wiring (concealed type) with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including rigid non-metallic PVC heavy duty conduit (ISI mark), 19/ 20 mm dia suitable size including cutting chases for conduits, sinking for boxes for concealed conduit wiring with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, suitable for fixing moduler switch/ socket and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth dolly and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point / bell point/ Ex Fan point / wall fan point controlled by one modular switch, 1 way 6/10 amps, 1 module. Make of Cable : Anchor / Havells / Finolex / Polycab Make of Conduit : Precision/ Prestoplast/ Polycab |
| 14 | M&L for point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLSH, passing through PVC casing caping including modular PVC Gang box of suitable module for mounting of modular Switches & Sockets as required at site along with one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLSH as earth wire connected to earth dolly all as specified & as directed by engr-in-charge for one light/ Exhaust fan/ Wall Fan point controlled by one switch Make of Cable : Anchor / Havells / Finolex / Polycab Make of Conduit : Precision/ Prestoplast/ Polycab |
| 15 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings, etc. and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed. |
| 16 | S&F in repairs ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed. Make : Cona , Plaza, Anchor . |
| 17 | S&F in repairs Moduler Switch single pole, one way 6/10 Amp with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame complete all as specified and directed. |
| 18 | S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 8 way with 200 Amps rated bus bar for single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed. Make : Havells / Legrand / Schneider / Indo Asian |
| 19 | S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 12 way with 200 Amps rated bus bar single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection complete all as specified and directed. Make : Havells / Legrand / Schneider / Indo Asian |
| 20 | S&F in repairs MCB SP 240 volt, 8 to 40 Amps, C series complete all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 21 | S&F in repairs MCB SPN 240 volt, 40 to 63 Amps, C series complete all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 22 | Supply and lay cable insulated screened PVC bedded, unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 1.5 Sqmm X 3 core for connecting up to post top lantern, garden light and looping box complete all as specified and directed . |
| 23 | Supply and lay cable insulated screened PVC bedded, unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 2.5 Sqmm X 3 core for connecting up to post top lantern, garden light and looping box all as specified and directed . |
| 24 | Taking down old UNSV burnt cable 1.5 sqmm to 6 sqmm size complete all as specified and directed . |
| 25 | Supply and fix for decorative pole antiquely designed aesthetically appealing landscape cum street light (3.0 metres long) along with single arm hanging bracket of suitable size made out from ERW pipe with base plate, finial taper plug, bolts, nuts, screws and top cover, suitable for fixing one Nos hanging light and testing complete all as specified and directed. |
| 26 | Supply and fix for octagonal pole antiquely designed aesthetically appealing landscape cum street light made out from hot deep galvanised (7.00 metres long) along with single arm bracket of suitable size made out from galvanised pipe complete with base plate having holes for mounting on foundation finial taper plug, bolts, nuts, screws and top cover, suitable for fixing street light and testing complete all as specified and directed. |
| 27 | Taking down old broken unserviceable, damaged/rusted swaged steel tublar poles/ cement poles of any size and remove from site complete all as specified and directed. |
| 28 | M&L PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) for making foundation of poles and pillars for gate light fixing complete all as specified and directed. |
| 29 | M&L PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) for making coping of Street light poles complete all as specified and directed. |
| 30 | S&F LED Hanging light Aluminium housing polymer defuser and pleasant lumin output IP -65 of capacity 40 watt LED 0f 6000k/3000k as per requirement on site including necessary brackets made out from GI pipe of suitable size and shape complete testing on ground complete all as specified and directed. |
| 31 | S&F LED Post top lantern fitting of capacity 25 watts, 100 lumen per watt capacity of 6000k/3000k as per requirement on site including GI Pipe in wall and all necessary fixing arrangement complete all as specified and directed. |
| 32 | S&F for LED Post top gate light fitting of capacity 50 watts, 100 lumen per watt capacity 0f 6000k/3000k as per requirement on site including GI Pipe in wall and all necessary fixing arrangement complete all as specified and directed. |
| 33 | S&F LED Post top lantern heritage light fitting of capacity 20 watts, 100 lumen per watt IP 65 of 6000k/3000k as per requirement on site including GI Pipe in wall and all necessary fixing arrangement all as specified and directed. |
| 34 | S&F LED BOLLARD light fitting of capacity 9 watts, 100 lumen per watt IP 65 0f 6000k/3000k as per requirement on site including necessary fixing arrangement complete all as specified and directed. |
| 35 | S&F LED BOLLARD mushroom type light fitting of capacity 9 watts, 100 lumen per watt IP 65 0f 6000k/3000k as per requirement on site including necessary fixing arrangement complete all as specified and directed. |
| 36 | S&F LED spot decorative spike light fitting of capacity 9/10 watts, IP 65 0f 6000k/3000k as per requirement on site including necessary fixing arrangement complete all as specified and directed. |
| 37 | Supply and fix 6 watt fountain light, IP-66, in warm white colour, of 6000k/3000k as per requirement on site of 6000k/3000k as per requirement on site complete all as specified and directed. |
| 38 | Supply and fix 9 watt wall light, IP-66, in warm white colour, of 6000k/3000k as per requirement on site of 6000k/3000k as per requirement on site complete all as specified and directed. |
| 39 | Taking down old unserviceable post top lantern, decorative outdoor fitting of any capacity and any type and remove from its location complete all as specified and directed. |
| 40 | Supply and fix LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminium conductor LT 1100 volts grade of size 35 Sqmm X 4 core with lugs and ferruls of suitable size complete all as specified and directed. |
| 41 | Supply and fix LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminium conductor LT 1100 volts grade of size 25 Sqmm X 4 core with lugs and ferruls of suitable size complete all as specified and directed. |
| 42 | Supply and fix LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminium conductor LT 1100 volts grade of size 16 Sqmm X 4 core with lugs and ferruls of suitable size complete all as specified and directed. |
| 43 | Supply and fix LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminium conductor LT 1100 volts grade of size 10 Sqmm X 4 core with lugs and ferruls of suitable size complete all as specified and directed. |
| 44 | Supply and fix cable LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminium conductor LT 1100 volts grade of size 10 Sqmm X 2 core with lugs and ferruls of suitable size complete all as specified and directed. |
| 45 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 4 sq. mm X 2 Core in service connections complete all as specified and as directed. |
| 46 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 6 sq. mm X 2 Core in service connections complete all as specified and as directed. |
| 47 | Taking down and up old unserviceable XLPE underground cable of any size from pole wall/roof/trenches complete all as specified and directed. |
| 48 | Labour only for taking out and checking of underground cable and relaying /rerouting the same cable of any size and any capacity including making serviceable electric connections complete all as specified and directed. |
| 49 | Material and labour GI tubing 50 mm dia light grade galvanized for cable protection and fixing of post top lantern with all connecting items (like suitable size of clamps, angle, nut & bolts) for holding of pipe with pole complete all as specified and directed. |
| 50 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/dense soil/RCC/PCC for laying of cable/ GI pipe complete all as specified and directed. |
| 51 | Supply and providing sand/stone dust for sand cushioning for cable protection or filling in trenches of sand in cable ducts after cleaning of ducts complete all as directed and specified Note:. for the purpose of payment punned thickness will be measured. |
| 52 | Supply and providing unreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) of sizes Class LV type I, flat size 250x150x40 mm putting adjecent to each other as specified. |
| 53 | Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed. |
| 54 | Removing surplus soil to a distance outside MD land and depositing n exc. 50m where directed at a level not exceeding 1.5m above the starting point all in including removing balance debries from MD land complete all as specified and directed. |
| 55 | M&L cement concrete 1:2:4 type B1 using 20mm graded aggregate in width for Feeder panel foundation/road filling including including rafts, footings, foundation beams plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 56 | S&F GI clamp including connected accessories and bracket made of GI Pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers etc including two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 57 | S&F street light single arm bracket made out of GI pipe 40 mm bore light grade 1.50 metre long bend to shape including welding etc and two sets of clamps made out of MS 40mm x 5mm bent to required shape and necessary nut bolt washer, including two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 58 | S&F street light double arm brackets made out of GI pipe 40 mm bore light grade 1.50 metre long bend to shape including welding etc and two sets of clamps made out of MS 40mm x 5mm bent to required shape and necessary nut bolt washer, including two coats of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 59 | Taking down/out old unserviceable rusted GI pipe light grade street light brackets building security light brackets and remove from its location complete all as specified and directed. |
| 60 | Taking down/out old unserviceable rusted GI pipe light grade of 50mm/40mm/25 mm bore and remove from its location complete all as specified and directed. |
| 61 | Supply and fix in repairs looping box made out from fiber of size 300X200X112mm, out door type weather proof with locking arrangement & comprising of three phase connector and MCB SPN 10 Amp, with suitable bus bar arrangements and fix on pole with and including suitable size MS clamps, MS flat iron, cable glands, nut bolts, washers all as specified and directed. |
| 62 | Supply and fix in repairs looping box made out from fiber of size 175X150X100mm, out door type weather proof with locking arrangement & comprising of connector MCB SPN 6 Amp and fix on pole with and including suitable size clamps, MS flat iron, cable glands, nut bolts, washers compete all as specified and directed. |
| 63 | S&F 12 KW Three Phase street light time switch distribution board with enclosure consisting with 40 Amps 3 pole power contactor and Digital time switch including taking down old unserviceable time switch, complete all as specified and directed. |
| 64 | S&F 6 KW Single Phase street light time switch with distribution board with enclosure consisting with 16 Amps single pole power contactor and DIGITAL time switch including taking down old unserviceable time switch, complete all as specified and directed. |
| 65 | Taking down old unserviceable Single/ Three phase street light time switch of any capacity and remove from its location complete all as specified and directed. |
| 66 | S&F in repairs steel perforated trunking system of size 180X30 mm and providing sturdy nuts and bolts for connecting cable trunking steadily onto walls or lying in air steadily with help of metal frame. |
| 67 | S&F in repairs PVC trunking system of size 60X30 mm and providing sturdy nuts and bolts for connecting cable as per requirement on site including necessary fixing arrangement complete all as specified and directed. |
| 68 | M&L for attending street light complaints and callibration of street light / Building Security light including checking of light fittings, cleaning fittings, check connection, looping boxes and made serviceable as per site requirement, complete all as specified and directed by Engineer-in-Charge. Note: Items will be paid separately. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender