Tender For Repair/ Miant Of Replacement Of Lt Ug Cables, Lt Panel Boards/ Feeder Pillar, Apfc Panels, Switch Gears Etc And Incl Comprehensive Maintenance Of Apfc Panels And Connected Works At installation Dronacharya Under Ge Fort Kochi
Tender Overview
Project Description
Tender for Repair/ Miant Of Replacement Of Lt Ug Cables, Lt Panel Boards/ Feeder Pillar, Apfc Panels, Switch Gears Etc And Incl Comprehensive Maintenance Of Apfc Panels And Connected Works At installation Dronacharya Under Ge Fort Kochi
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and making good bottom surface for laying/ removing of cable, erection of poles in soft/ loose soil complete, all as specified and as directed. |
| 2 | Material and labour for removing excavated soil to a distance not exceeding 50 meter and not exceeding 1.5 meter above the starting point, and depositing where directed complete, all as specified and as directed. |
| 3 | Material and labour for Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and Above sand shall be obtained through digging at site 500 mtrs distance and transporting to site for punned use to sand cushioning up to 18cm thickness, complete all as specified and as directed Note : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured. |
| 4 | Material and labour for burnt bricks subclass B laid in trenches for cable protection complete all as specified and as directed. |
| 5 | Returning filling in excavated soil in trenches, watering and well ramming in layers not exc 25 cm complete all as specified. |
| 6 | Taking out UNSV UG cables of any sizes from trenches/walls including all mounting accessories and GI tubing and keeping aside in safe custody for relaying after repairs including making good to disturbed areas, complete all as specified and as directed. |
| 7 | Relaying of UG cable Nominal cross section Area of 10 to 50 sqmm 2/4 core after testing, carrying out of joining works complete all as specified and as directed. Note: - Necessary Joints will be measured and paid separately under relevant item of Sch A |
| 8 | Relaying of UG cable Nominal cross section Area of 70 to 150 sqmm 3.5 core after testing, carrying out of joining works complete all as specified and as directed. Note: - Necessary Joints will be measured and paid separately under relevant item of Sch A |
| 9 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 95 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. |
| 10 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 120 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 1) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. |
| 11 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 150 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 2) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. |
| 12 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 185 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 3) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. |
| 13 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 240 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 4) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. |
| 14 | Material and labour for XLPE insulated PVC sheathed armoured with multistranded aluminium conductor cable having cross sectional area 300 sqmm 3.5 core, 1100-volt grade, Heavy grade conforming to IS :7098 (Part 5) laid in trenches/Ducts or passing through pipes or fixing on poles etc complete all as specified and directed. with stranded aluminium conductor of size laid in trenches, ducts etc complete all as specified and as directed. |
| 15 | Material and labour for LT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cable of size up to 95 sqmm to 120 sqmm 3.5 core complete all specified and as directed |
| 16 | All as above but for cable sizes 150 sqmm to 185 sqmm 3.5 core. |
| 17 | All as above but for cable sizes 240 to 300 sqmm 3.5 core |
| 18 | Material and labour for PVC insulated multi stranded copper conductor flexible wire 16 sqmm single core for inter connections in LT panel boards and all fixing accessories and including taking down UNSV copper conductor flexible wire, old materials complete all as specified and as directed. |
| 19 | Material and labour for PVC insulated multi stranded copper conductor flexible wire 25 sqmm single core for inter connections in LT panel boards and all fixing accessories including taking down UNSV copper conductor flexible wire, old materials complete all as specified and as directed. |
| 20 | Material and labour for servicing of LT Panel boards outdoor/indoor of any sizes installed at various locations of under this division by disconnecting from mains taking out burnt cable ends, cleaning of panel and reconnecting using necessary cable connections, small internal panel cable connections, lugs, cable glands, gland plate, gaskets etc and application of necessary mechanical and electrical lubrication when and where as directed by Engr-in-Charge. Note :- (Necessary spares will be measured and paid under relevant items completely) |
| 21 | Material and labour for fixing in repairs of Aluminium Bus bar of desired sizes bend to shape as required at site including all necessary drilling works including taking out old UNSV bus bar and repairing of burnt cable ends using new lugs, complete all as specified and as directed |
| 22 | Material and labour for fabrication / welding of sheet metal components of panel boards using 2.00 mm CRCA powder coated sheets when and where as required as in doors, partitions etc including fixing to existing panels using all necessary hinges, panel locks, weather proof gaskets etc as required at site complete including taking down complete all as specified and as directed. |
| 23 | Material and labour for painting of LT Panel boards outdoor/indoor of sizes up to 200 x 150 x 50 cms installed at various locations under this division, by scrapping out of rusted uneven surfaces and applying by spray painting two coats of paint of desired shade over a coat of metallic primer complete all as specified and as directed. |
| 24 | Material and labour for painting of LT Panel boards outdoor/indoor of sizes up to 100 x 100 x 40 cm installed at various locations, by scrapping out of rusted uneven surfaces and applying by spray painting two coats of paint of desired shade over a coat of metallic primer complete all as specified and as directed. |
| 25 | Preparation of cement based painted surfaces by scrapping of deposited materials, and painting with two coats of cement-based paint of approved make and colour complete all as specified and as directed. |
| 26 | Supplying and laying GI tubing light grade of following size including all accessories for encasing cables for mechanical protection, laid under plinth / floors/ paths culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/drilling works including taking down old GI tubing complete all as specified and directed (Note:MS works will be measured under separate item in Schedule) |
| 27 | (a) 80 mm bore |
| 28 | (b) 50 mm bore |
| 29 | Supply and fix in replacement of MCCB 415V 63 Amps TPN 16 KA thermal magnetic release with spreader terminals and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete all as specified and as directed. |
| 30 | Supply and fix in replacement MCCB 415V 100 Amps TPN 25 KA thermal magnetic release with spreader terminals adjustable type and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete all as specified and directed. |
| 31 | Supply and fix in replacement MCCB 415V 125 Amps TPN 25 KA thermal magnetic release with spreader terminals adjustable type and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete all as specified and directed. |
| 32 | Supply and fix in replacement MCCB 415V 160 Amps TPN 36 KA thermal magnetic release with spreader terminals adjustable type and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete all as specified and directed. |
| 33 | Supply and fix in replacement MCCB 415V 200 Amps TPN 36 kA thermal magnetic release with spreader terminals adjustable type and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete all as specified and directed. |
| 34 | Supply and fix in replacement MCCB 415V 250 Amps TPN 36 kA microprocessor-based release with spreader terminals adjustable type and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete all as specified and directed. |
| 35 | Supply and fix in replacement MCCB 415V 400 Amps TPN 36 KA thermal magnetic release with spreader terminals Adjustable type and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete all as specified and as directed. |
| 36 | Supply and fix in replacement MCCB 415V 630 Amps TPN 50 KA thermal magnetic release with spreader terminals adjustable type and including making necessary connections, fixing to panel Boards and ensure compatibility with existing MCCB in fit and finish complete all as specified and as directed. Make: Legrand DPX or equivalent from Siemens/Schneider/L&T/ABB. |
| 37 | Supply and fixing of danger notice plate for LT of size 25 cm x 20 cm, 1.6mm thick mild steel sheet vitreous enamelled white with letters, figure and conventional skull & bones “DANGER 1100 VOLTS” etc. in signal red colour and fixed with MS clamps made out of 25mmx3mm MS flat iron, nut, bolts, including taking down UNSV Danger board, old materials complete all as specified and as directed. |
| 38 | Material and labour for PCC (1:3:6) type C-1 (using 20 mm graded black trap/granite/basalt stone aggregate) for coping of the pole including necessary form work complete all as specified and as directed. |
| 39 | Supply and fixing phase Indicator lamp with holder key flush mounted, LED type Red, yellow, blue including taking down old materials complete all as specified and as directed. |
| 40 | Supply and fix in repairs Digital type Voltmeter 0-500 volts, 3 Phase, 4-digit, high resolution, LED type with one side programmability, complete all as specified and as directed. |
| 41 | Supply and fix in repairs Ammeter digital type (0-500 Amps) with resin cast copper wound CT coil assy of suitable ratio & size class I accuracy, 0.5 VA burden, & onsite programmability, complete all as specified and as directed. |
| 42 | Material and labour for fixing in repairs on walls or laying in trenches double wall HDPE Corrugated flexible pipe heavy duty of internal dia 80 mm including all accessories complete all as specified and as directed. Make: - Apollo, Jain, Gamson. |
| 43 | Material and labour for fixing in repairs on walls or laying in trenches double wall HDPE Corrugated flexible pipe heavy duty of internal dia 50 mm including all accessories complete all as specified and as directed. Make: - Apollo, Jain, Gamson or equivalent |
| 44 | Demolition of concrete of any description and in any position not otherwise provided for complete all as specified and as directed |
| 45 | Material and labour for PCC 1:3:6 type C-2 (using 40 mm gradedstone aggregate) for coping in poles and finishing of visible external surfaces including demolition of old cracked PCC foundation and removal from site, complete all as specified and as directed. |
| 46 | Supply and fixing in repairs Mild steel work in framed work such as Clamps, gratings, ladders etc., with ends of bars welded and/ or riveted, or forged and similar work confirming to Fe. 290.Gde -E-165 etc. complete all as specified and as directed. |
| 47 | Material and labour for applying painting work to Mild steel work in framed work such as Clamps, gratings, ladders etc. Surfaces of using One coats of metallic primer Red Oxide Zinc Chrome and two coats of synthetic enamelled paint of desired colour complete all as specified and as directed. |
| 48 | Material and labour for GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit including taking down UNSV old materials complete all as specified and as directed |
| 49 | Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick buried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to DB/Panel by using GI strip of 32x6 mm sleeved using red colour PVC sleeving as earthing lead soldering/rivetted to earth plate at one end and connected To DB by means of nut, bolts etc complete with PCC pit (1:3:6) type PCC cover with handle, funnel with watering pipe wire mess GI protection pipe for earthing lead including taking down unserviceable old materials complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 50 | Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick buried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to DB/Panel by using GI strip of 32x6 mm sleeved using red colour PVC sleeving as earthing lead soldering/rivetted to earth plate at one end and connected To DB by means of nut, bolts etc complete with PCC pit (1:3:6) type PCC cover with handle, funnel with watering pipe wire mess GI protection pipe for earthing lead including taking down unserviceable old materials complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender