Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #57375922

Tender For Maintenance And Repair Of Electric Fittings Fixtures, Wiring And Connected Items At Omq Of Sp Area, Smc, Swimming Pool, Officers Mess And Other Connected Area Under Ge (Af) Subroto Park

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
30 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
3 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Maintenance And Repair Of Electric Fittings Fixtures, Wiring And Connected Items At Omq Of Sp Area, Smc, Swimming Pool, Officers Mess And Other Connected Area Under Ge (Af) Subroto Park

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 26-Sep-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-Oct-2026

BOQ

Name of Work:- MAINTENANCE AND REPAIR OF ELECTRIC FITTINGS FIXTURES, WIRING AND CONNECTED ITEMS AT OMQ OF SP AREA, SMC, SWIMMING POOL, OFFICERS MESS AND OTHER CONNECTED AREA UNDER GE (AF) SUBROTO PARK
Sl. No. Item Description
1Taking down carefully copper / aluminium point wiring light, fan, light fittings, socket or power complete, such as switches, ceiling roses, pendents, regualtors, sockets etc removing materials to store for keeping in safe custudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc complete all as specified and directed.
2M&L for point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade (FRLS), ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit after cutting, chasing the wall etc and making good of disturbed surface, including all accessories etc, heavy duty ISI marked, including mild steel sunken boxes with earth dolly duly powder coated suitable for modular plates of required size, covered with modular plates, suitable for modular switches, sockets etc including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) (FRLS) single core cables as earth continuity conductor to common earth and connecting to earth dolly for one light /fan /ex fan point controlled by one switch. (Note- Modular switch and sockets will be measured and paid separately)
3All as per item No 2 above but For one bell point controlled by one bell push
4All as per item No 2 above but for one 3 pin socket outlet , 6 Amps on same board
5All as per item No 2 above but for one 3 pin socket outlet , 6 Amps on Independent board
6All as per item No 2 above but one light point controlled by two 2 - way SP switches
7All as per item No 2 above but with 2.5 Sqmm cable for Independent board one 3 pin 15 Amps socket outlet including single core 2.5 Sqmm PVC insulated copper conductor unsheathed 1100v grade IS-694 FRLS cable for continuous earth wire 2.5 Sqmm FRLS all as specified and directed. (Only one 15 Amp point will be in one circuit)
8All as per item No 2 above but with 4 Sqmm cable for Independent board one 3 pin 15 Amps socket outlet including single core 2.5 Sqmm PVC insulated copper conductor unsheathed 1100v grade IS-694 FRLS cable for continuous earth wire 2.5 Sqmm FRLS all as specified and directed. (Only one 15 Amp point will be in one circuit)
9M&L for point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade (FRLS), ISI-694 marked drawn through in existing steel/ PVC concealed conduit , including all accessories etc, heavy duty ISI marked, including mild steel sunken boxes with earth dolly duly powder coated suitable for modular plates of required size, covered with modular plates, suitable for modular switches, sockets etc including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) (FRLS) single core cables as earth continuity conductor to common earth and connecting to earth dolly for one light / fan/ ex fan point controlled by one switch. (Note- Modular switch and sockets will be measured and paid separately)
10All as per item No 9 above but For one bell point controlled by one bell push
11All as per item No 9 above but for one 3 pin socket outlet , 6 Amps on same board
12All as per item No 9 above but for one 3 pin socket outlet , 6 Amps on Independent board
13All as per item No 9 above but For one light point controlled by two 2 - way SP switches
14All as per item No 9 above but with 2.5 Sqmm cable for Independent board one 3 pin 15 Amps socket outlet including single core 2.5 Sqmm PVC insulated copper conductor unsheathed 1100v grade IS-694 FRLS cable for continuous earth wire 2.5 Sqmm FRLS all as specified and directed. (Only one 15 Amp point will be in one circuit)
15S&F Modular switch 6 Amps, 230 V, single pole, two way, 1 module complete all as specified and as directed.
16S&F Modular switch 6 Amps, 230 V, single pole, one way, 1 module complete all as specified and as directed.
17S&F Socket modular type 2/3 pin combined 2 module, 6 Amps, 230V complete all as specified and as directed.
18S&F Modular switch 16 Amps, 230 V, single pole, one way, 1 module complete all as specified and as directed.
19S&F Socket, modular type 2/3 pin combined,2 module, 6 Amps/16 Amps complete all as specified and as directed.
20S&F Modular step step type fan regulator suitable for ceiling fan of 1200mm sweep, 120 watts, 2 module complete all as specified and as directed.
21Supply and fixing for modular bell push 6 Amps 230V, single pole, one way, 1 module complete all as specified and as directed.
22M&L for point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (nominal area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade (FRLSH), ISI-694 marked drawn through in existing steel/ PVC concealed conduit and making good of disturbed surface, , excluding mild steel sunken boxes but includes 3 mm thick laminated hylam sheet top cover for fixing switches, switch socket outlets etc including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) (FRLSH) single core cables as earth continuity conductor to common earth and connecting to earth dolly for one light / fan/ ex fan point controlled by one switch. (Note- Piano switch and sockets will be measured and paid separately)
23All as per item No 22 above but one bell point controlled by one No bell push
24All as per item No 22 above but for one 3 pin socket outlet , 6 Amps on same board with the cables 1.5 Sqmm size complete all as specified and directed.
25All as per item No 22 above but for one 3 pin socket outlet , 6 Amps on independent board with the cables 1.5 Sqmm size complete all as specified and directed.
26All as per serial item No.22 here-in-before but For one light point controlled by two 2 - way SP switches
27All as per serial item No.22 here-in-before but wiring with 2.5 Sqmm including 2.5 Sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 volts grade, single core earth continuity conductor connected to common earth dolly for one 3/5 pin 15 amps switch socket out let on independent board.
28M&L for point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sqmm (nominal cross-sectional area), single core, PVC insulated and unsheathed stranded cable 1100 volts grade (FRLSH) conforming to IS-694 with multistranded copper conductor drawn thorugh and including PVC casing and capping /surface conduit complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI marked) for mounting switches/regulator etc and including 1.50 Sqmm (nominal area) , PVC insulated unsheathed multistranded FRLSH copper conductor cable 1100 volts grade, single core for earth continuity conductor connected to common earth dolly for light/fan/bell point controlled by one switch and making good disturbed surfaces of walls, floors etc for light/fan/bell point complete all as specified and directed.Note- Piano switch and sockets will be measured and paid seperately)
29All as per Item No 28 herien before but one 3 pin socket outlet, 5 Amps, independent board.
30All as per Item No 28 herien before but one three pin switch socket 5 Amps plug point on same board
31All as per item No 28 herein before but point wiring with 2.5 Sqmm single core multi stranded copper conductor FRLSH, for one three pin socket 15 Amps on independant board controlled by one 15 Amps Switch including continuous earth wire PVC insulated 2.5 Sqmm single core multi stranded copper conductor connected to common earth dolly.
32All as per item No 28 above but with 4 Sqmm cable for Independent board one 3 pin 15 Amps socket outlet including single core 2.5 Sqmm PVC insulated copper conductor unsheathed 1100v grade IS-694 FRLS cable for continuous earth wire 2.5 Sqmm FRLS all as specified and directed by Engr-in-Charge (Only one 15 Amp point will be in one circuit)
33S&F Switch piano 5 Amps flush type single pole two way suitable for 240 volt AC complete all as specified and as directed.
34S&F switch piano, flush button single pole one way 5 Amp complete all as specified and as directed.
35S&F Socket out let 3 pin 5 Amps, flush type complete all as specified and as directed.
36S&F Switch piano 16 Amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed.
37S&F Socket outlet 2 in 1, 5 pin 16 Amps flush type suitable for 240 volt AC complete all as specified and directed.
38S&F Step type fan regulator suitable for ceiling fan of 1200mm sweep, 120 watts, complete all as specified and as directed.
39S&F Bell push, flush type 5 Amp complete all as specified and as directed.
40Supply and fix ding dong bell AC 230 volt single pole complete all as specified and directed.
41Supply & fix in replacement batten holder PVC white suitable for retrofit type CFL/LED lamp complete all as specified and as directed.
42S&F in repair LED lamp E27 bulb base of 9 watts 6000K complete all as spfd and directed.
43S&F in repair LED lamp E27 bulb base of 9 watts 3000K complete all as spfd and directed.
44Supply and fixing of ceiling rose, surface bakelite, 65mm x50mm 2 or 3 terminals, PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed.
45S&F socket outlet 2 in 1, 5 pin 25 Amps flush type suitable for 240 volt AC complete all as specified and directed.
46S&F Modular MCB SP 25 Amps 10 KA, 240 volt 1 module all as specified and directed by Engineer-in-charge.
47Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete all as specified and directed.
48M & L fir in circuit/submain wiring with two run of 2.5 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 2.5 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through PVC casing caping, medium grade,complete with all accessories and fittings all and complete all as specified and directed.Note - 3 Runs of 2.5 Sqmm and one run of PVC casing caping will be used as one unit for measurement purpose.
49All as per item No 48 above but for 1.5 sqmm wire
50Taking down old unsv VTPN DB of any size complete all as specified and directed
51Supply and fixing DB VTPN 12 ways with provision for FP MCB/isolator/ RCCB/ MCCB etc 'A' Frame as incomer and SP/TP as outgoing double door IP 54 complete prewired including 250 Amp bus bar etc suitable for operation on 415 volts 50 Hz AC supply, suitable for TP incomer MCCB of 125/160/200 Amps including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc and making good of disturbed surfaces to match with existing colour of wall complete all as specified and as directed .
52Supply and fixing DB VTPN 08 ways with provision for FP MCB/isolator/ RCCB/ MCCB etc 'A' Frame as incomer and SP/TP as outgoing double door IP 54 complete prewired including 250 Amp bus bar etc suitable for operation on 415 volts 50 Hz AC supply, suitable for TP incomer MCCB of 125/160 Amps including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc and making good of disturbed surfaces to match with existing colour of wall complete all as specified and as directed.
53Supply and fixing DB VTPN 06 ways with provision for FP MCB/isolator/ RCCB/ MCCB etc 'A' Frame as incomer and SP/TP as outgoing double door IP 54 complete prewired including 250 Amp bus bar etc suitable for operation on 415 volts 50 Hz AC supply, suitable for TP incomer MCCB of 125/160 Amps including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc and making good of disturbed surfaces to match with existing colour of wall complete all as specified and as directed.
54Supply and fixing DB VTPN 04 ways with provision for FP MCB/isolator/ RCCB/ MCCB etc 'A' Frame as incomer and SP/TP as outgoing double door IP 54 complete prewired including 250 Amp bus bar etc suitable for operation on 415 volts 50 Hz AC supply, suitable for TP incomer MCCB of 125/160 Amps including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc and making good of disturbed surfaces to match with existing colour of wall complete all as specified and as directed.
55Taking down old unsv MCB SPN DB of any size complete all as specified and directed.
56M & L in replacement MCB distribution board with bus bar 200 A, neutral link, earth bar made out of CRCA mild steel sheet with double door category of protection type IP- 42 factory made with tinned copper 200 Amps rated bus bar suitable for MCB SPN 08 way 230 Volts, horizontal type ,concealed in wall such that front cover shall be seen flush with the wall surface all as specified and directed. Note :- MCB SP/SPN shall be measured and paid separately.
57All as per item No 56 above but SPN 12 way
58S&F in replacement of MCCB 200 Amps FP 415 volts, 3 Phase 50 Hz, Ics=100%Icu, breaking capacity 36 KA complete all as specified and directed.
59S&F in replacement of MCCB 160 Amps FP 415 volts, 3 Phase 50 Hz, Ics=100%Icu, breaking capacity 36 KA complete all as specified and directed.
60S&F in replacement of MCCB 125 Amps FP 415 volts, 3 Phase 50 Hz, Ics=100%Icu, breaking capacity 36 KA complete all as specified and directed.
61S&F MCB SP 6 to 32 Amps 10KA, 240 volt 'B' series complete all as specified and directed.
62S&F MCB SP 40 Amps 10KA, 240 volt 'B' series complete all as specified and directed.
63S&F MCB SPN 40 to 63A Amps 10KA, 240 volt 'B' series complete all as specified and directed.
64S&F MCB TP 25 to 63 Amps 10KA, 240 volt, 50 Hz 'B' series complete all as specified and directed.
65Supply and fixing 4 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections all as required or directed.
66Supply and fixing 6 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections all as required or directed.
67Supply and fixing 10 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections all as required or directed.
68Taking down carefully sub main wiring of any type and size including fittings and fixtures, removing materials from site complete all as directed.
69M & L fir in submain wiring with two run of 10.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit, medium grade, ISI marked (not less than 25 mm dia) complete with all accessories and fittings all laid/fixed concealed in wall and surface conduit on ceiling portion only complete all as specified.Note - 3 Runs of 10.0 Sqmm and one run of PVC conduit will be used as one unit for measurement purpose.
70All as sper item No 69 above but for 6.0 Sqmm wire
71All as per item No 69 above but for 4.0 sqmm wire
72Supply installation commissioning testing of earthing in any kind of soil/strata complete with copper bonded earthing electrode chemical earthing system outer electrode dia 25 mm and 3 mtr long tightly filled with crystalline conductor mixture 250 microns copper coated along with bag of back bill compound 50 kg buried directly in the ground (earth pit not less than 2.25 meter deep below ground level) connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts,nuts,check nuts and washers and connecting earthing test point ,including CI covers ,frame and PCC (1:3:6) type C-2 using 20 mm graded stone aggergate as in earthing pit with CI cover and framing including necessary earth work etc complete all as specified .Note- PCC chamber shall be constructed at least one meter away from the building shall be provided in slanting manner.Note- PCC cover pit shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 kg (sqm in liew of CI)
73Material and labour for galvanised iron strip 25mm x 4 mm with saddles and fixing screws and connected as per site requirement complete all as specified and as directed.
74All as per item No 73 but 4 mm dia GI wire
75Taking down of light fittings of any wattage complete all as specified and directed
76Supply and fixing wall mounted LED batten extruded aluminium heat shrink provide for efficient heat dissipation and integrated electronic driver, 20 watt LED fitting with 120 lumen/watt, 6000k, 230 volts, diffuser optics, etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting and testing complete all as specified and directed.
77Supply and fixing wall mounted LED batten extruded aluminium heat shrink provide for efficient heat dissipation and integrated electronic driver, 20 watt LED fitting with 120 lumen/watt, 3000k, 230 volts, diffuser optics, etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting and testing complete all as specified and directed.
78Supply and fixing wall mounted LED batten extruded aluminium heat shrink provide for efficient heat dissipation and integrated electronic driver, 10 watt LED fitting with 120 lumen/watt, 6000k, 230 volts, diffuser optics, etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting and testing complete all as specified and directed.
79Supply and fixing wall mounted LED batten extruded aluminium heat shrink provide for efficient heat dissipation and integrated electronic driver, 10 watt LED fitting with 120 lumen/watt, 3000k, 230 volts, diffuser optics, etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting and testing complete all as specified and directed.
80Supply and fixing wall mounted LED bulk head fittings, 10 watt, 230 volts, diffused optics etc complete with all accessoreis, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting and testing complete all as specified and as directed . Please Enable Macros to View BoQ information
81Supply and fixing wall mounted LED bulk head fittings, 10 watt, 230 volts, diffused optics etc complete with all accessoreis, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting and testing complete all as specified and as directed . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57375922
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 03-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maintenance And Repair Of Electric Fittings Fixtures, Wiring And Connected Items At Omq Of Sp Area, Smc, Swimming Pool, Officers Mess And Other Connected Area Under Ge (Af) Subroto Park
Basic Detail
Tender No GE/SP/TOKEN-38/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 26 Sep 2026
Submission Date 03 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
59a74b70-bf9c-4c69-9eac-114427b384eb.html
BOQ_883260.xls
Tender38.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

59a74b70-bf9c-4c69-9eac-114427b384eb.html

xls

BOQ_883260.xls

pdf

Tender38.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders