Power Boards / Undertakings / PSU Closing in 14 days TDR #57372073

Tender for Battery MCCBs for UPS systems at UCB and BOP PLCs

Issued by Boards / Undertakings / PSU · , Telangana
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Sep 2026
14 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Telangana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Battery Mccbs For UPS Systems At UCB And BOP Plcs , Model: Tmax T1B 160 Rated Current (In): 100 A Rated Uninterrupted Current (Iu):160 A,Breaking Capacity Is Equal To 16KA At 415V,Thermo Magnetic Release Type Rated Impulse Withstand Voltage (Uimp): 8 KV Rated Insulation Voltage (Ui): 800 V Rated Operational Voltage Ue Is Equal To 690V AC, Also Provision For Under Voltage Trip Coil With Coil Voltage Rating Is Equal To 110V DC Auxillary Contacts For ON/OFF Status Feedback To UPS Makes: ABB/L And T/Schnider Make 3 Pole MCCB Equivallent To ABB SACE Tmax MCCB , 3 Pole MCCB At Equivalant To L And T Make DH250 : MCCB 250 Amps Rated Operating Voltage Ue Is Equal To 415Volts At 50Hz,Insulation Voltage Ui Is Equal To 690V At 50HZ, Short Ckt Breaking Capacity I Cu Is Equal To 35Ka , Service Breaking Capacity Ics Is Equal To 100% I Cu, Utilization Category- A With Thermal Magnetic Release, Actual Trip Setting In Is Equal To 250A, Instantaneous Is Equal To 6 In , Also Provision For Under Voltage Trip Coil With Coil Voltage Is Equal To 110V DC And Auxillary Contacts For ON/OFF Status Feedback To UPS Makes: ABB/L And T/Schnider , 3Pole MCCB ,Rated Current: 63Amps(In),Breaking Capacity: 10 Ka At 415Volt, Insulation Voltage: 690Volts, Uimp(Impulse With Stand Voltage): 8KV Makes:ABB/L And T/Schnider , 3 Pole MCCB Equivalent To L And T Make DH400 At 400Amps Rated Operating Voltage Ue Is Equal To 415Volts At 50Hz,Insulation Voltage Ui Is Equal To 690V At 50HZ, Short Ckt Breaking Capacity I Cu Is Equal To 35Ka , Service Breaking Capacity Ics Is Equal To 100% I Cu, Utilization Category- A With Thermal Magnetic Release, Actual Trip Setting In Is Equal To 400A, Instantaneous Is Equal To 6 In Makes: ABB/L And T/Schnider , 3 Pole MCCB Equivallent To Merlin Gerin Model: NKS100R, Type:MCCB,3Pole Rated Current (In): 100 A Breaking Capacity Is Equal To 10KA At 415V, Service Breaking Capacity(Ics):50% Of Icu Is Equal To 5KA. Rated Impulse Withstand Voltage (Uimp): 8 KV Rated Insulation Voltage (Ui): 690 V Rated Operational Voltage Ue Is Equal To 415V AC, Frequency:50/60Hz,Standard :Cat A,IEC 60947-2/IS 13947(Part 2) Makes: ABB/L And T/Schnider /Merlin Gerin , 3 Pole MCCB Equivallent To Merlin Gerin Model: NKS100R, Type:MCCB,3Pole Rated Current (In): 50 A Breaking Capacity Is Equal To 10KA At 415V, Service Breaking Capacity(Ics):50% Of Icu Is Equal To 5KA. Rated Impulse Withstand Voltage (Uimp): 8 KV Rated Insulation Voltage (Ui): 690 V Rated Operational Voltage Ue Is Equal To 415V AC, Frequency:50/60Hz,Standard :Cat A,IEC 60947-2/IS 13947(Part 2) Makes: ABB/L And T/Schnider /Merlin Gerin , 3 Phase Un-Balance RMS Monitoring Relay, L1,2,3: 3- 300-500V 50Hz, 0,1 S - 30S/ 2 C/O Ithe Is Equal To 4A, U Imp Is Equal To 6KV/4Kv Fuse(Fast):10A NO, 6A(NC)/1Ka, AC15:230V 3A DC13: 24V/2A Model Equivallant To ABB Make CM-PAS.41S/ 1SVR730774R3300( Order Code For ABB Make)

BOQ

Sl. No. Item Name
1Model: Tmax T1B 160Rated Current (In): 100 ARated Uninterrupted Current (Iu):160 A,Breaking capacity is equal to 16KA at 415V,Thermo magnetic Release typeRated Impulse Withstand Voltage (Uimp): 8 KVRated Insulation Voltage (Ui): 800 VRated Operational Voltage Ue is equal to 690V AC,also provision for Under Voltage Trip coil with coil voltage rating is equal to 110V DC Auxillary contacts for ON/OFF status feedback to UPSMakes: ABB/L and T/Schnider make 3 pole MCCB equivallent to ABB SACE Tmax MCCB
23 Pole MCCB at Equivalant to L and T make DH250 : MCCB 250 Amps Rated Operating Voltage Ue is equal to 415Volts at 50Hz,Insulation Voltage Ui is equal to 690V at 50HZ, Short ckt breaking capacity I cu is equal to 35kA , Service Breaking capacity Ics is equal to 100% I cu, Utilization category- A with Thermal magnetic release, Actual trip setting In is equal to 250A, Instantaneous is equal to 6 In , also provision for Under Voltage Trip coil with coil voltage is equal to 110V DC and Auxillary contacts for ON/OFF status feedback to UPS Makes: ABB/L and T/Schnider
33Pole MCCB ,Rated Current: 63Amps(In),Breaking Capacity: 10 kA at 415Volt, Insulation Voltage: 690Volts, Uimp(Impulse with stand voltage): 8KVMakes:ABB/L and T/Schnider
43 Pole MCCB Equivalent to L and T make DH400 at 400Amps Rated Operating Voltage Ue is equal to 415Volts at 50Hz,Insulation Voltage Ui is equal to 690V at 50HZ, Short ckt breaking capacity I cu is equal to 35kA , Service Breaking capacity Ics is equal to 100% I cu, Utilization category- A with Thermal magnetic release, Actual trip setting In is equal to 400A, Instantaneous is equal to 6 In Makes: ABB/L and T/Schnider
53 pole MCCB equivallent to Merlin GerinModel: NKS100R,Type:MCCB,3PoleRated Current (In): 100 ABreaking capacity is equal to 10KA at 415V,Service Breaking Capacity(Ics):50% of Icu is equal to 5KA.Rated Impulse Withstand Voltage (Uimp): 8 KVRated Insulation Voltage (Ui): 690 VRated Operational Voltage Ue is equal to 415V AC,frequency:50/60Hz,Standard :Cat A,IEC 60947-2/IS 13947(Part 2)Makes: ABB/L and T/Schnider /Merlin Gerin
63 pole MCCB equivallent to Merlin GerinModel: NKS100R,Type:MCCB,3PoleRated Current (In): 50 ABreaking capacity is equal to 10KA at 415V,Service Breaking Capacity(Ics):50% of Icu is equal to 5KA.Rated Impulse Withstand Voltage (Uimp): 8 KVRated Insulation Voltage (Ui): 690 VRated Operational Voltage Ue is equal to 415V AC,frequency:50/60Hz,Standard :Cat A,IEC 60947-2/IS 13947(Part 2)Makes: ABB/L and T/Schnider /Merlin Gerin
73 Phase Un-balance RMS Monitoring Relay, L1,2,3: 3- 300-500V 50Hz, 0,1 s - 30s/ 2 C/O Ithe is equal to 4A, U imp is equal to 6KV/4kV Fuse(fast):10A NO, 6A(NC)/1kA, AC15:230V 3A DC13: 24V/2A model equivallant to ABB make CM-PAS.41S/ 1SVR730774R3300( order code for ABB make)

AI Tender Summary

OUR REF NO 57372073
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 23-09-2026
Authority
Authority Name Telangana Power Generation Corporation Limited
Work Description Battery Mccbs For UPS Systems At UCB And BOP Plcs , Model: Tmax T1B 160 Rated Current (In): 100 A Rated Uninterrupted Current (Iu):160 A,Breaking Capacity Is Equal To 16KA At 415V,Thermo Magnetic Release Type Rated Impulse Withstand Voltage (Uimp): 8 KV Rated Insulation Voltage (Ui): 800 V Rated Operational Voltage Ue Is Equal To 690V AC, Also Provision For Under Voltage Trip Coil With Coil Voltage Rating Is Equal To 110V DC Auxillary Contacts For ON/OFF Status Feedback To UPS Makes: ABB/L And T/Schnider Make 3 Pole MCCB Equivallent To ABB SACE Tmax MCCB , 3 Pole MCCB At Equivalant To L And T Make DH250 : MCCB 250 Amps Rated Operating Voltage Ue Is Equal To 415Volts At 50Hz,Insulation Voltage Ui Is Equal To 690V At 50HZ, Short Ckt Breaking Capacity I Cu Is Equal To 35Ka , Service Breaking Capacity Ics Is Equal To 100% I Cu, Utilization Category- A With Thermal Magnetic Release, Actual Trip Setting In Is Equal To 250A, Instantaneous Is Equal To 6 In , Also Provision For Under Voltage Trip Coil With Coil Voltage Is Equal To 110V DC And Auxillary Contacts For ON/OFF Status Feedback To UPS Makes: ABB/L And T/Schnider , 3Pole MCCB ,Rated Current: 63Amps(In),Breaking Capacity: 10 Ka At 415Volt, Insulation Voltage: 690Volts, Uimp(Impulse With Stand Voltage): 8KV Makes:ABB/L And T/Schnider , 3 Pole MCCB Equivalent To L And T Make DH400 At 400Amps Rated Operating Voltage Ue Is Equal To 415Volts At 50Hz,Insulation Voltage Ui Is Equal To 690V At 50HZ, Short Ckt Breaking Capacity I Cu Is Equal To 35Ka , Service Breaking Capacity Ics Is Equal To 100% I Cu, Utilization Category- A With Thermal Magnetic Release, Actual Trip Setting In Is Equal To 400A, Instantaneous Is Equal To 6 In Makes: ABB/L And T/Schnider , 3 Pole MCCB Equivallent To Merlin Gerin Model: NKS100R, Type:MCCB,3Pole Rated Current (In): 100 A Breaking Capacity Is Equal To 10KA At 415V, Service Breaking Capacity(Ics):50% Of Icu Is Equal To 5KA. Rated Impulse Withstand Voltage (Uimp): 8 KV Rated Insulation Voltage (Ui): 690 V Rated Operational Voltage Ue Is Equal To 415V AC, Frequency:50/60Hz,Standard :Cat A,IEC 60947-2/IS 13947(Part 2) Makes: ABB/L And T/Schnider /Merlin Gerin , 3 Pole MCCB Equivallent To Merlin Gerin Model: NKS100R, Type:MCCB,3Pole Rated Current (In): 50 A Breaking Capacity Is Equal To 10KA At 415V, Service Breaking Capacity(Ics):50% Of Icu Is Equal To 5KA. Rated Impulse Withstand Voltage (Uimp): 8 KV Rated Insulation Voltage (Ui): 690 V Rated Operational Voltage Ue Is Equal To 415V AC, Frequency:50/60Hz,Standard :Cat A,IEC 60947-2/IS 13947(Part 2) Makes: ABB/L And T/Schnider /Merlin Gerin , 3 Phase Un-Balance RMS Monitoring Relay, L1,2,3: 3- 300-500V 50Hz, 0,1 S - 30S/ 2 C/O Ithe Is Equal To 4A, U Imp Is Equal To 6KV/4Kv Fuse(Fast):10A NO, 6A(NC)/1Ka, AC15:230V 3A DC13: 24V/2A Model Equivallant To ABB Make CM-PAS.41S/ 1SVR730774R3300( Order Code For ABB Make)
Basic Detail
Tender No 215/26-27/ I&C/P-21/CE/O&M/KTPS-V&VI Stages
Bidding Type Tender
Location
City
State Telangana
Key Dates
Publish Date 05 Sep 2026
Submission Date 23 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
37387de4-be2b-4b02-9db5-ce0f7d1ff450.html
DocumentsList.zip
download.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

37387de4-be2b-4b02-9db5-ce0f7d1ff450.html

zip

DocumentsList.zip

xls

download.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders