Power Government Departments Closing in 4 days TDR #57370946

Tender For Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of Electric Substation 2X100 Kva Water Supply Scheme Beli Stage Zero And 2X100 Kva Water Supply Scheme Beli Stage First At Water Supply Scheme Medic

Issued by Government Departments · Udhampur, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Sep 2026
4 days left
EMD
1.03 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udhampur → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of Electric Substation 2X100 Kva Water Supply Scheme Beli Stage Zero And 2X100 Kva Water Supply Scheme Beli Stage First At Water Supply Scheme Medical College Beli Including Strengthening Of Existing 11 Kv Mansar Feeders By Way Of Insertion /Replacement Of St Poles And Replacement Of Multilated,Blazed Acsr Conductor For Smooth And Interruption Free Power On Turnkey Basis.

BOQ

Name of Work:- Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of Electric Substation 2X100 KVA WSS Beli Stage zero and 2x100 KVA WSS Beli Stage First at WSS Medical College Beli including strengthening of Existing 11 KV Mansar Feeders by way of insertion /replacement of ST poles and replacement of multilated,Blazed ACSR Conductor for smooth and interruption free Power on turnkey basis.
Sl. No. Item Description
1Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor including Tapping point at WSS Govt. Medical college Beli Stage First And Stage Zero including strengthening of Existing 11 KV Mansar Feeder
29 mtr. Long ST Pole (ST-410 SP-33)
3GI V Cross -arm with top Bracket including clamps
4GI Channel X-arm including clamps and Angle for braces
511kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
630mm² ACSR Weasel Conductor
750mm² ACSR Weasel Conductor
8PG Clamps
911 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
1011 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
11Galvanized Nuts and Bolts
12Danger Plates with Clamps
13Anti climbing device with clamps
14Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
15Painting of 9 mtr ST poles with two coats of Aluminium paint.
16Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
17Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
18Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 100 KVA Sub stn. at WSS Govt. Medical college Beli Stage First
1911/0.433kV, 3-phase Distribution Transformers 100 KVA with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
20Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymerhousing, Stn. Type
2111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
2211 kV Horn Gap Fuse Set 3 Phase 200A
23120 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type
249 mtr. Long ST Pole (ST-410 SP-33)
2511kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting.
26GI Channel/Angle/Flat of sizes including clamps
27Galvinized Nuts and Bolts.
28Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber
2911 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
30LT Distribution Box for 100 KVA DTR with MCCB for incomer and SFU's for outgoing Circuits.
31Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
32PG Clamps
33Danger plates with clamps
34GI Barbed wire for Anti Climbing
35LT Prodigy meter
36Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
37Painting of substation ST poles/cross arm/clamps with one coat of Red oxide and two coats of aluminium paint
38Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for installation of 100 KVA at WSS Govt. Medical college Beli Stage Zero
3911/0.433kV, 3-phase Distribution Transformers 100 KVA with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
40Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymerhousing, Stn. Type
4111kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
4211 kV Horn Gap Fuse Set 3 Phase 200A
43120 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type
449 mtr. Long ST Pole (ST-410 SP-33)
4511kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting.
46GI Channel/Angle/Flat of sizes including clamps
47Galvinized Nuts and Bolts.
48Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber
4911 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
50LT Distribution Box for 100 KVA DTR with MCCB for incomer and SFU's for outgoing Circuits.
51Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
52PG Clamps
53Danger plates with clamps
54GI Barbed wire for Anti Climbing
55LT Prodigy meter
56Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
57Painting of substation ST poles/cross arm/clamps with one coat of Red oxide and two coats of aluminium paint
58Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Govt. Medical college Beli Stage Zero and Stage First
598 mtr. Long ST poles (ST-410 SP15)
60GI M Clamps for shackle insulator
6130mm² ACSR Weasel Conductor
62Shackle insulator
63Galvanized Nuts and Bolts.
64Danger Plates with Clamps
65Anti climbing device with clamps
66Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip
67Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
68Painting of 8 mtr ST poles with two coat of Aluminium Paint
69Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57370946
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 18-09-2026
Authority
Authority Name Power Development Department
Work Description Tender for Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of Electric Substation 2X100 Kva Water Supply Scheme Beli Stage Zero And 2X100 Kva Water Supply Scheme Beli Stage First At Water Supply Scheme Medical College Beli Including Strengthening Of Existing 11 Kv Mansar Feeders By Way Of Insertion /Replacement Of St Poles And Replacement Of Multilated,Blazed Acsr Conductor For Smooth And Interruption Free Power On Turnkey Basis.
Basic Detail
Tender No ED/UDH/27 OF 2026-27 dated 05-09-2026
Bidding Type Tender
Location
City Udhampur
State Jammu and Kashmir
Key Dates
Publish Date 05 Sep 2026
Submission Date 18 Sep 2026
Open Date 19 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 2000
EMD 1.03 Lakhs
Exemption Not Available
Document List
6c77d04a-ea16-4ed2-8e72-4719e93ddb32.html
BOQ_1089552.xls
Tendernotice_1 (16).pdf
Tendernotice_2.pdf
Tendernotice_3 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

6c77d04a-ea16-4ed2-8e72-4719e93ddb32.html

xls

BOQ_1089552.xls

pdf

Tendernotice_1 (16).pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders