Tender For Face Lifting Of The Inspection Bungalow At Pahalgam, Construction Of Additional Accomodation, Including Washroom Amount Of Work: Rs. 38.80Lacs
Tender Value
38.80 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
2 days left
EMD
1.16 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Face Lifting Of The Inspection Bungalow At Pahalgam, Construction Of Additional Accomodation, Including Washroom Amount Of Work: Rs. 38.80Lacs
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 min width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected: as directed by Engineer -in-Charge. Lead up to 1 meter from cutting edge .All kinds of soil |
| 2 | Dumping stone excluding cost of stones in horizontal on level |
| 3 | Supply of soling stones |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Coursed Rubble Masonry with hard stone in foundation and plinth and curing complete with Cement mortar 1:6 (1 Cement : 6 coarse Sand) 2nd Sort |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 inCement mortar 1:6 ( 1 cement : 6 coarse sand) superstructure above plinth level upto floor five level |
| 9 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses , plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Centering, Shuttering including strutting propping and removal of form work |
| 12 | Foundations, footings, bases of columns etc. for mass concrete |
| 13 | Walls (any thickness) including attached pilasters,buttresses, plinth and string courses etc. |
| 14 | Columns, pillars, piers, abutments, posts and struts. |
| 15 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 16 | Suspended floors, roofs, landings, balconies and access platforms |
| 17 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo -Mechanically Treated bars of grade Fe-500D or more. |
| 19 | 12mm Cement plaster of mix 1 : 4 (1 cement : 4 fine sand) |
| 20 | Ruled/ Flush pointing on Red sand Brick masonry/ stone masonry surface with lime, surkhi and marble dust mortar in the ratio 1:1.5:1/2 one lime : 1.5 surkhi ( 50% red and 50% light yellow surkhi):1/2 marble dust (the rate is inclusive of all materials and labours involved except scaffolding) |
| 21 | Providing and fixing of UPVC doors and windows (frames, shutters both wire guage and pannelled, glazed) with compolete fittings inclusive of toughened glass and all accessories required at site for complete job |
| 22 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 23 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: Two or more coats applied @ 1.25 liter/ 10sqm over and including one coat of special primer applied @ 0.75liter /10sqm |
| 24 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate.. |
| 25 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In colour such as White, Ivory, Grey, Fume Red Brown |
| 26 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 27 | Providing and fixing Polyvinyl Chloride (PVC) pipes, including all fittings, bends and other accessories. This includes jointing of pipes and fittings as per direction of Engineer-in-charge. External work including trenching, refilling etc. 75/100mm nominal outer dia pipes. (PRINCE) |
| 28 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at .00 meter spacing including cutting chases and making good the wall etc. |
| 29 | PN-16 pipe , 20mm OD(SDR-7.4) |
| 30 | PN-16 pipe, 40mm OD (SDR-7.4) |
| 31 | Providing and fixing PPR Unions |
| 32 | PPR Union 20mm |
| 33 | PPR Union 40mm |
| 34 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 35 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 36 | Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. |
| 37 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereverrequired:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 38 | Providing and fixing 01 No. of Geyser of standard quality Jaquar/ Venus 50 Litres with a minimum 15 mm CP Brass single hole basin mixer |
| 39 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. |
| 40 | Supply and fixing of Mirror of superior make glass 60x45 cm |
| 41 | Providing and fixing soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 42 | Providing and fixing of Towel Rail (600 mm long) |
| 43 | Providing and fixing of bath tubs of standard make including all accessories required for the complete job. |
| 44 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 45 | Providing & Fixing of 1.0 hp water motor for lifting of water upto storage tank. Including all accessories required for complete job |
| 46 | Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete job. Poplar wood |
| 47 | Providing & Fixing of corrugated color coated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick |
| 48 | Providing & Fixing of plain color coated Wooden sheets (kail wood) of thickness 25mm for eaves boarding including all accessories required for the complete job. |
| 49 | Providing & Fixing of plain color coated Wooden sheets (RAIT wood) of thickness 25mm for soffits including all accessories required for the complete job. |
| 50 | Providing & fixing wardrobes inclusive all accessories (hinges, handles, locks etc ) using water proof plywood, making exterior of high standards,polishing HDHMR sheets as suggested by incharge site engineer |
| 51 | Providing and fixing HDHMR panelling on walls inclusive of 12 mm thick plywood bases including all sorts of accessories required. |
| 52 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete job inclusive of frame work. Natural colour insulating board of 12mm thickness. |
| 53 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately. Paanch Murabah |
| 54 | Application of high quality polish.clearing of all specks from the surface using filling, sandpaper, exquisite make of polish surface |
| 55 | Application of high quality duco polish.clearing of all specks from the surface using filling, sandpaper, exquisite make of polish surface. |
| 56 | Providing and fixing of POP ceiling inclusive of all accessories required for complete job. |
| 57 | Providing & Fixing of Wood Floor (flooring and skirting) (high pressure laminate sheets) of standard make (green panel etc) following inclusive of all accessories required at site as per direction of engineer in charge complete job |
| 58 | Wiring for light point/fan point/exhaust fan point/call bell point with 2 × 1.5 sq.mm PVC insulated, FRLS copper conductor, 1100 V grade wires, conforming to IS 694, with conductors as per IS 8130 and insulation as per IS 5831, and having fire performance in accordance with IEC 60332, ISI marked with valid BIS license, complete with all accessories , ( Havell/ Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor or OEMs/ firms holding ISO 9001 certification (Quality Management System) and shall be supplied with routine test certificates, and any material not conforming to the specified standards shall be rejected , complete with all accessories as required; single core cable in surface / recessed medium class PVC conduit ( including cost of conduit), with modular switch ( Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-A |
| 59 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit ( including cost of conduit) |
| 60 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.) |
| 61 | Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) as described in item no 1 as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit,( including cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 62 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 no. 3 pin 5-10 A modular socket outlet and 2 no. 5-10 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc /SSK NV/schneider LIvia /Crabtree athena make.) |
| 63 | Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required. i. 3 pin 5/6A socket outlet |
| 64 | Supplying and fixing of following modular switch/ socket/indicator on the existing modular plate and switch box including connections but excluding modular plate etc. as required. i. Indicator |
| 65 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/APAR/ Fenolex/KEI/RR kabel/ Anchor make ) as described in item no 1 , single core cable in surface/ recessed medium class PVC conduit as required. Including cost of conduit. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (Lighting Circuit) |
| 66 | S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve ,Schneider / Legrand /ABB, / Havells ,/ Siemens/ L&T / Hager /BCH make OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer in charge. |
| 67 | 6-32 Amp SP MCB |
| 68 | 32 amp DP MCB |
| 69 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates. |
| 70 | Supplying and fixing following way, Horizontal type,Single pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager/ABB make) 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 12 way , Double door |
| 71 | Supply installation testing and commissioning of 12 W LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W . The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt. approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures also. (Philips/ Havel's /Wipro make / sample to be approved before installation). |
| 72 | Supply of 10W surface/wall-mounted SMD LED bulkhead luminaire, 1000 lm, system efficacy ≥100 lm/W, 5700K, CRI≥80, with powder-coated die-cast aluminium housing, high-transmission opal PC diffuser, silicon gasket, IP65 and IK10 protection. LM80-08 compliant LEDs from reputed make, L70 life ≥50,000 hours and IEC 62471 photobiological safety compliant. Integrated isolated constant-current driver, 140–280V AC, efficiency >80%, PF≥0.95, THD≤10% and 2.5kV surge protection. Compliant with relevant IS standards including IS 10322, IS 16105, IS 16106, IS 15885 and IS 16108. LM79/LM80 reports from NABL/UL accredited laboratory shall be submitted. |
| 73 | Supply, installation, testing and commissioning of 1 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Usha (Sample to be got approved), incl. cost of extension of GI rod (if required) and making of necessary connections. |
| 74 | Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make. |
| 75 | Supply, installation, testing and commissioning of exhaust fan of 300 mm sweep suitable for wall/window mounting, complete with necessary frame, mounting arrangement, louvers/shutter, and all accessories as required; the fan shall be of robust construction with high-grade engineering plastic/metal body, aerodynamically designed blades, and heavy-duty copper motor suitable for continuous operation, conforming to relevant Indian Standards and safety requirements of Havell /Bajaj/Crompton/ USHA/Orient OR OEMs/ firms holding ISO 9001 certification (Quality Management System) as directed by engineer incharge as per site requirement and necessary connections. |
| 76 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) 5 panels |
| 77 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. Normal INCOMING: |
| 78 | MCCB 100 Amps DP Icu=Ics=100% Breaking Capacity 16 KA ROH /Legrand/ Shinider/Semiens/ABB make. |
| 79 | b) 2 No. of Aluminium Bus Bar of100 Amp. |
| 80 | c)Digital meters and phase indicators -1 set. |
| 81 | OUTGOING: |
| 82 | 32 amp DP MCB c curve 10 K Legrand/ Shinider acti-9/ABB make, sample to be approved before installation.. |
| 83 | Providing of chemical earthing as per IS standards by way of digging 6 feet pit then embedding 2.5 mtr. Long GI earthing electrode, 60 mm dia. Connecting the electrode with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound. |
| 84 | Supply, Installation, Testing and Commissioning of 1.5 TR Wall-Mounted Inverter Split Air Conditioner, Cooling & Heating (Reverse-Cycle Heat Pump) Type, 5-Star energy-efficiency rated, having rated cooling capacity of approximately 5.0–5.3 kW and minimum rated heating capacity of 5.0 kW , conforming to applicable IS/BIS and BEE requirements, operating on 230 V ±10%, 50 Hz, single-phase AC supply, complete with hermetically sealed inverter-driven rotary compressor with variable-speed operation, indoor evaporator unit and outdoor condensing unit with copper tubes and aluminium fins, suitable for operation under the climatic conditions of the site. The unit shall have a low-ambient heating operating capability, capable of satisfactory heating operation at outdoor ambient temperatures down to at least −10°C, or lower, as certified by the OEM. |
| 85 | Supply and fixing of additional insulated copper refrigerant piping, comprising liquid and suction lines of suitable diameter for 2 TR split air-conditioning units, beyond the 3 m piping length included with the main AC item, laid from indoor unit to outdoor unit, complete with closed-cell rubber insulation, suitable protective covering, fittings, joints, supports, clamps and all necessary accessories, as per OEM recommendations and site requirements, including all labour and incidental works, complete in all respects. Make: TOTALINE / MANDEV / METTUBE or equivalent approved make. |
| 86 | Supply of wall Mounting type 4 KVA capacity, Metal body, single phase, Automatic line Voltage stabilizers with copper wound coil having an input voltage 135 to 275V and a balanced/steady output voltage of 230 V +_ 3% , single phase, 50Hz AC with built in time delay, cut off and low voltage cut-off, i/p, o/p/trip indications, metal clad top etc., with connecting 3 core cable of 1 meter length complete etc. as per site requirement. EVEREST/ V-GUARD/ PREMIER |
| 87 | Supply and installation of suitable rated DP MCB and industrial/modular AC isolator/plug-and-socket arrangement, as recommended by the AC OEM and suitable for the connected load, complete with accessories. |
| 88 | Carriage of materials by MT |
| 89 | Coarse Agg.40mm by Avg 28km |
| 90 | Coarse Agg.20mm by Avg 28km |
| 91 | Fine Agg. (Sand) by Avg 45 km |
| 92 | Cement by Avg 35km |
| 93 | Steel by Avg 35kms |
| 94 | Stones by Avg 15km |
| 95 | Bricks by Avg 35kms Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer