Housing Urban and Rular Development Government Departments Closing in 2 days TDR #57370234

Tender For B.O.Q For 06 Roomed Double Storey Building At Hss Newa B.W.O Electric Work

Issued by Government Departments · Pulwama, Jammu and Kashmir
Tender Value
25.78 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
2 days left
EMD
51567
Bank guarantee accepted
Document Fee
1100
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for B.O.Q For 06 Roomed Double Storey Building At Hss Newa B.W.O Electric Work

BOQ

Name of Work:- B.O.Q for 06 Roomed double storey building at HSS Newa B.W.O Electric work
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/eq. standard make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit, with modular switch ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.), modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit.
3Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Leiva /ABB Tvisha make make.)
4Wiring for lighting circuits/ 6- 10 amp power plugwith 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.)
6Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
7Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, \\"C\\" curve including connections, painting etc. as required.
8Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/ equivalent as directed by engineer incharge.), single core cable in surface/ recessed medium class PVC conduit as required.
9(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
10( c ) 2 X6 sq. mm + 1 X 6 sq. mm earth wire ( submain for emergency circuit)
11( d )2 X 10 sq. mm + 1 X 6 sq. mm earth wire ( Lighting submain/ three phase points)
12(e) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire ( Heating Submain)
13Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete
14Providing and fixing of 6-16mm Cu thimbles duly cramped at cable ends.
15Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
16Supply installation testing and commissioning of Indicator of Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /Crabtree athena make.)
17Supply installation testing and commissioning of AC/DC Bell including Bell push and battries GM/ standard make
18Sub Head-2 - Fixtures and Fittings
19Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux/Wipro make / sample to be approved before installation..
20Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan ( USHA/havell /Bajaj/Crompton/equivalent make as directed by engineer incharge,) with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. the job includes the steel rod of suitable size and length to be installed at site.
21Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Tivsha/schneider Livia /Havell Coral make.
22Supply installation testing and comm. Of 250mm -300mm sweep exhaust fan Shutter type of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
23Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
246 way (4 + 18), Double door
25Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( Havell/ legrand/ Shinider/SSK make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
262 + 12 way, Double door
27S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ ABB ./equivalent make as directed by engineer incharge.
28a) 6-32 Amp SP MCB
29b) 40-63amp DP MCB
30Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by8- 10 SWG G.I wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound.
31S/L , testing and commissioning of PVC XLPE insulated alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
32c)95 sq.mm 3.5 core
33c)70 sq.mm 3.5 core
34Earth work excavation for cable trench, 2 ft deep with an average breadth of 1.5ft and refilling of trench with excavated earth after laying of cable and ramming it properly excluding cost of cable.the job also includes laying of warning tape .
35Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
36160 mm dia (OD-160 mm & ID-135 mm nominal)
37Supply installation testing and comm. of flood light 100 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job.
38Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement)
39Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
40Normal INCOMING:
41a)200A 4P MCCB 25 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.
42b) 4 No. of Aluminium Bus Bar of 300 Amp.
43c)Digital meters and phase indicators -1 set.
44d) onload Change over switch 100 Amp for generator.Front operated.
45e) 4 No. of Aluminium Bus Bar of 200 Amp.
46c)Digital meters and phase indicators -1 set.
47Inverter Incommer
48(a) 100 amp DP MCCB 16 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.
49(b) 200 Amp 2 strip bus bar
50c)Digital meters and phase indicators -1 set.
51OUTGOING:
52c) 40-63amp DP MCB
53c) space for 24 way MCB's
54Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical
55S/I testing and comm. Of three phase 15 KVA 50HZ oil cooled(Transformer oil is to be provided with stabilizer conforming to IS 335,IEC296)) unbalanced type servo voltage stabilizer(A.E / Cosco/Chinar/ Electricfield make) having an input voltage ranging from 156V to 415 V ( phase to phase) and balanced output voltage of 415V, +/- 1%. ( Test certificate to be provided by the manufacturer) The unit incorporate
56a) 0-500V moving iron type voltmeter with selector switch.
57b) A three phase change over switch to read voltage on incoming and output side
58c) indicating lights 6 No two numbers for each of the motorised units, one for lower limit and other for higher limit.
59d) six push button control for movement operation of three motorised dimmer units two for each unit i.e one for raise operation and one for lower operation under the conditions of adjustment of auto/mannual selector switch (DPDT)
60e) Single phase Preventer ( contactor Switch of required rating) Legrand make.
61f) six potential meter resistance with lock meter two for each phase control, one for sensitivity and other for level control.
62g) two sets of indication lamps three numbers each to indicate output and input indication
63h) 20 % over load bearing capacity for one hour.
64Supply, Installation, Testing & Commissioning of 6 KVA single-Phase IN single-Phase out ON Line UPS System to provide backup time of 30 minutes at full load, With In-Built Isolation Transformer of reputed make dully ISI Marked (APC Schineider/ETON/VERTIV/ equivalent standard make ) (Compitable to Genrator Supply having varing frequency) With on line double conversion topology, high frequency techonology, with front LCD,automatic bypass for fault tolerance & complete with required Number, 12 Volts 65 AH SMF VRLA Batteries ( Exide/ Amaron/Quanta make) with connecting links with angle iron battery stand complete job, complete with battery rack with two year warranty against any manufacturing defect. The job further includes AMC for UPS and batteries for a period of three years with replacement warrenty reckoned from date of sucessfull commissioning.
65Supply installation testing and commissioning of 2 Ton inverter type split Air Conditioning system( hot and cold) suitable for operation on AC supply single phase 220 V . The indoor unit fitted on wall by employing suitable clamps and the outdoor unit fitted on the wall by using suitable angle iron stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning.( Mitsubishi/Toshiba/O-General make)
66Supply, Installation, testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton - 2 Ton AC operating from input voltage 90-260 Volts thereby producing output voltage of 230 volts +/- 3 % ( Vguard/ Livgaurd/LG make)
67Supply & Erection of lockable 9 U rack with 5A strip and two fan for distribution, mounting of patch panels, hubs, switches etc,, complete as per specification and as desired by EIC.
68Supply & Erection of CAT 6, 24 port Jack panel for termination of CAT6 cable, Testing & certification of the network with Omni/Penta Scanner of each Cable
69Supply & Erection of Cat-6, 1Mtr Patch Cords complete as per specification and as desired by EIC.
70Supplying, Installation, TestingandCommissioningof40 InchesFull H.D LED Display Monitor of Sony/Samsung /LG or equelent
71Supplying of 20- 24 Channel Network Video Recorder(NVR) as per the Specifications Enclosed with a Hard Disk Memory of 8 TB capacity.
72Supplying, Installation, Testing and Commissioning of 8 Port Layer 2 Managed PoE switch of ISI standard make with wall mounted rack fully loaded of required size complete.ion
73Supply, Installation, Testing & Commissioning of Indoor Dome Camera IP CCTV Monitoring, Recording & Streaming Systems per the Following Specifications:- Minimum 4 megapixel progressive scan HD CMOS Lens :- 3-6 mm or Better , DC‐Iris/Auto Iris Field of view:-100˚to 45˚ (horizontal) 72-34 ° (vertical) Day/night operation: The camera should provide day/night functionality automatically switches to night mode in low‐light scenes Wide dynamic range:- True WDR 100dB or equivalent or better Minimum illumination /light sensitivity :- Color mode: @0.2 lux black and white mode: @0.03 lux Video compression:- H.265 motion JPEG Resolutions and frame rates (H.265):- At 2304x1728, the frame rate shall be 25 FPS or better for viewing. All the streams shall be user configurable (with respect to resolution, frame rate & compression standard). All the cameras (sensors) shall have minimum 5 streams. PoE:- It should be PoE enabled and with IK08 enclosure and in built 20m IR Certification:- It should be FCC, CE, UL certified ONVIF:- ONVIF 2.0 Support Supported protocol:- DHCP, HTTP, HTTPS, NTP, RTP, RTSP, SMTP, SSL/TLS,TCP/IP, Secure Real Time Transport Protocol (SRTP) Honey Well , Bonjour, SNMP, and Secure Shell (SSH)
74Supplying, Laying and Drawing of UPT-4 pair CAT-6 LAN cable drawn partly in existing recessed/surface conduits, partly in xisting recessed/surface mounted raceways and partly in existing cable ducts in modular furniture complete as per specifications and as required. DLink make
75Supply & Erection of Media Convertor complete as per specification and as desired by EIC
76Supply, installation, testing and commissioning of 75 inch 4K Ultra HD Interactive Flat panel Digital Board/ smart Board best for teaching screen, Display resolution Max. 3840x2160, anti glareglass, Multi touch screen, Stylus Dock, bluetooth, WIFI, USB, Ethernet, HDMI facility. samsung/Panasonic/LG make ( 3 years onsite warranty)
77Supply, Installation, Testing and Commissioning of 24 port Networking switck (Dlink/Eq make)
78Supply, Installation, Testing and Commissioning of RJ 45 Data outlets with single back box of 27 Dlink/Legrend/siemens make with making of necessary connections through networing engineer and as required at site Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57370234
AUTHORITY Government Departments
TENDER VALUE 25.78 Lakhs
LAST DATE 18-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for B.O.Q For 06 Roomed Double Storey Building At Hss Newa B.W.O Electric Work
Basic Detail
Tender No NIT No.144//2026-27 Dt 05/09/2026
Bidding Type Tender
Location
City Pulwama
State Jammu and Kashmir
Key Dates
Publish Date 05 Sep 2026
Submission Date 18 Sep 2026
Open Date 19 Sep 2026
Finance
Tender Value 25.78 Lakhs
Tender Fee 1100
EMD 51567
Exemption Not Available
Document List
bb154b77-1e65-4796-a65b-02f16e25f50f.html
BOQ_1089255.xls
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

bb154b77-1e65-4796-a65b-02f16e25f50f.html

xls

BOQ_1089255.xls

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders