Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #57364425

Tender For Providing Of 4 X Jcos Married Accomodation At Solan Mil Station Under Ge Kasauli.

Issued by Statutory Bodies & Commissions/Committees · Solan, Himachal Pradesh
Tender Value
1.38 Crore
Estimated cost
Bid Submission
10 Oct 2026
8 days left
EMD
2.13 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Providing Of 4 X Jcos Married Accomodation At Solan Mil Station Under Ge Kasauli.

BOQ

Name of Work:- PROVN OF 4 X JCOs MARRIED ACCOMODATION AT SOLAN MIL STATION UNDER GE KASAULI.
Sl. No. Item Description
1Lump Sum price worked out by the contractor for \\"BUILDING WORKS\\" as listed in Schedule 'A' Part-I
2Lump Sum price worked out by the contractor for \\"INTERNAL ELECTRIC SUPPLY WORKS\\" as listed in Schedule 'A' Part-II
3Lump Sum price worked out by the contractor for \\"INTERNAL WATER SUPPLY WORKS\\" as listed in Schedule 'A' Part-III
4Lump Sum price worked out by the contractor for \\"SEWAGE DISPOSAL WORKS\\" as listed in Schedule 'A' Part-IV
5Lump Sum price worked out by the contractor for \\"AREA DRAINAGE WORKS\\" as listed in Schedule 'A' Part-V
6Lump Sum price worked out by the contractor for \\"ROAD/ PATH/ HARD STANDING WORKS\\" as listed in Schedule 'A' Part-VI
7Lump Sum price worked out by the contractor for \\"EXTERNAL ELECTRIC SUPPLY WORKS\\" as listed in Schedule 'A' Part-VII
8Lump Sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY WORKS\\" as listed in Schedule 'A' Part-VIII
9Lump Sum price worked out by the contractor for \\"PROTECTIVE WORKS\\" as listed in Schedule 'A' Part-IX
10Lump Sum price worked out by the contractor for \\"RAILING/ FENCING WORKS\\" as listed in Schedule 'A' Part-X
11Lump Sum price worked out by the contractor for \\"SITE CLEARANCE, DEVELOPMENT AND EARTH WORKS (FOR PART-II TO PART-X)\\" as listed in Schedule 'A' Part-XI
12Lump Sum price worked out by the contractor for \\"DEMOLITION AND DISMANTLING WORKS\\" as listed in Schedule 'A' Part-XII
13Schedule 'A' Part- XIV (Misc Items) Note : This schedule is not pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only.
14Misc items for Internal Electric Supply Works
15Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable conforming to IS-694 of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly drawn in and including new concealed rigid PVC non metallic conduit terminated on and including new modular GI metal sunken box of thickness not less than 1.2 mm and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall including cutting chases (using electric driven cutter) in any type of wall complete, comprising of One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and as directed by Engineer-in-Charge.Note: Cost of cutting chases and making good shall deemed to be included in the unit rate quoted against the item.
16All as per Serial item No. 13.00 here-in-before but for One light point controlled by two, 2-way switches.
17All as per Serial item No. 13.00 here-in-before but for one socket outlet 3/ 5 pin, 5 Amps on independent board complete all as specified and as directed by Engineer-in-Charge.
18All as per Serial item No. 13.00 here-in-before but for socket outlet 3 pin 5 Amps on same board complete all as specified and as directed by Engineer-in-Charge.
19All as per Serial item No. 13.00 here-in-before but for one socket outlet 3/5 pin, 15/ 16 Amps on independent board, size of cable 2.5 sqmm for phase, neutral & 2.5 sqmm as earth wire complete all as specified and as directed by Engineer-in-Charge.
20S&F Inverter type LED tube light batten 4 feet, 1 x 18/20 watt, 230 volts inbuilt Lithium ion battery with charging time 8 to 10 Hours and back up time minimum 4 Hours complete including fitting fixed on wall/ ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection complete all as specified and directed by Engineer-in-charge.
21S&F LED street light fitting, 35 watt LED, 230 volts, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection with and including light mounting bracket made out of 25 mm bore GI pipe light grade 1.0 metre long, bent in shape as per requirement for fitting including two pair of MS plate iron clamp of size 32mm x 5 mm thickness with nuts, bolts and washers suitable for fixing in outer wall of building including painting of mild steel flat iron surface, two coats of synthetic enamel paint over a red oxide primer complete all as specified and as directed by Engineer-in-charge.
22Supply and fixing Exhaust fan, steel body, AC single Phase, 230V of size 300 mm sweep, 900 RPM, with blades, frame and louvers, shutters etc., mounted on walls with nuts, bolts, washers including cutting hole for air ducting for exhaust fan in Circle/ square shape or as per site requirement into or through brick/ concrete walls built in cement mortar of area suitable for exhaust fan including making good of disturbed area in cement mortar 1:3 or cement concrete 1:2:4, type B-l complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information
23Supply and fixing Exhaust fan, steel body, AC single Phase, 230V of size 300 mm sweep, 900 RPM, with blades, frame and louvers, shutters etc., mounted on walls with nuts, bolts, washers including cutting hole for air ducting for exhaust fan in Circle/ square shape or as per site requirement into or through brick/ concrete walls built in cement mortar of area suitable for exhaust fan including making good of disturbed area in cement mortar 1:3 or cement concrete 1:2:4, type B-l complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57364425
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.38 Crore
LAST DATE 10-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing Of 4 X Jcos Married Accomodation At Solan Mil Station Under Ge Kasauli.
Basic Detail
Tender No CWE/KAS-61/2026-27
Bidding Type Tender
Location
City Solan
State Himachal Pradesh
Key Dates
Publish Date 05 Sep 2026
Submission Date 10 Oct 2026
Open Date 12 Oct 2026
Finance
Tender Value 1.38 Crore
Tender Fee 1000
EMD 2.13 Lakhs
Exemption Not Available
Document List
4d4dd273-71ae-434e-9598-3b5d5b802da1.html
Additional61.pdf
Architechdrawings.pdf
BOQ_883254.xls
STDs.pdf
STRUCTURALDRAWING.pdf
TDs.pdf
Tenderdocuments61.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

4d4dd273-71ae-434e-9598-3b5d5b802da1.html

pdf

Additional61.pdf

pdf

Architechdrawings.pdf

xls

BOQ_883254.xls

pdf

STDs.pdf

pdf

STRUCTURALDRAWING.pdf

pdf

TDs.pdf

pdf

Tenderdocuments61.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders