Housing Urban and Rular Development Government Departments Closing in 10 days TDR #57363867

Tender For Supply And Installation Of New Main Pannel With Fire Supression System To Main Building And Eye Hospital At Dhh Khordha Buildings.

Issued by Government Departments · Khordha, Odisha
Tender Value
17.01 Lakhs
Estimated cost
Bid Submission
17 Sep 2026
10 days left
EMD
17100
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply And Installation Of New Main Pannel With Fire Supression System To Main Building And Eye Hospital At Dhh Khordha Buildings.

BOQ

Name of Work:- Supply and installation of new main Pannel with Fire supression system to main building and eye hospital at DHH khordha Buildings.
Sl. No. Item Description
1sub pannel : SITC of 16/ 18 SWG panel box 2x(48x36)+(12x36)+(12x48) sq. inch for single door made out of CR sheet of 16/ 18 SWG and boarder angle frame to provide above pannel with proper space ,hinges, and other accessories , hinged door etc. with powder coating ( For Eye hospital)
2Provision of internal wiring to equipment installed in the pannel board with required size of copper multistrand single core cables duly crimped with copper lugs and all connections 2x(48x36)+(12x36)+(12x48) including cost of copper conductor and other fittings like gasket ,screw , nut and bolt , insulating materials etc.( 2no. pannel)
3Busbar-1&2 04 numbers of 400Amps copper busbar with 1.6A/SQ.MM current carring capacity. 25mm X 5mm busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) for sub pannel
4S/F of CT Coil
5S/F of Indicator lamp with trangular switch
6SITC of digital type multifunction meter for voltage,current,frequency,PF,THD indication with COMPACTIVITY FOR bms data.
7Supply and fixing of 200A 36KA DPX3 4pole MCCB with Thermal Mangnetic Protecton unit in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required.(Make- Legrand/ ABB/ Simens/ schneider)equivalent)as per direction of Engineer-in-charge
8S/F of 160A On load change over 4pole without cover(Make- ABB/Legrand/ Simens/ schneider)equivalent)as per direction of Engineer-in-charge
9Supply and fixing of 63 A 25KA DPX3 4pole MCCB with Thermal Mangnetic Protecton unit in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required.(Make- Legrand/ ABB/ Simens/ schneider)equivalent)as per direction of Engineer-in-charge
10Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 1 years.
11sub pannel : SITC of 16/ 18 SWG panel box 2x(36x36)+(12x36)+(12x36) sq. inch for single door made out of CR sheet of 16/ 18 SWG and boarder angle frame to provide above pannel with proper space ,hinges, and other accessories , hinged door etc. with powder coating ( For DHH FF Surgery ward)
12Provision of internal wiring to equipment installed in the pannel board with required size of copper multistrand single core cables duly crimped with copper lugs and all connections 2x(36x36)+(12x36)+(12x36) including cost of copper conductor and other fittings like gasket ,screw , nut and bolt , insulating materials etc.( 2no. pannel)
13Busbar-1&2 04 numbers of 400Amps copper busbar with 1.6A/SQ.MM current carring capacity. 25mm X 5mm busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) for sub pannel
14S/F of CT Coil
15S/F of Indicator lamp with trangular switch
16SITC of digital type multifunction meter for voltage,current,frequency,PF,THD indication with COMPACTIVITY FOR bms data.
17Supply and fixing of 160A 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release Electrical locking ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
18Supply and fixing of 63 A 25KA DPX3 4pole MCCB with Thermal Mangnetic Protecton unit in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required.(Make- Legrand/ ABB/ Simens/ schneider)equivalent)as per direction of Engineer-in-charge
19S/F of 63A On load change over 4pole without cover(Make- ABB/Legrand/ Simens/ schneider)equivalent)as per direction of Engineer-in-charge
20Main pannel : SITC of 16/ 18 SWG panel box 2x(84x84)+(28x84)+(84x28) sq. inch for Double door made out of CR sheet of 16/ 18 SWG and boarder angle frame to provide above pannel with proper space ,hinges, and other accessories , hinged door etc. with powder coating with Nomencluture(For DHH)
21Provision of internal wiring to equipment installed in the pannel board with required size of copper multistrand single core cables duly crimped with copper lugs and all connections 2x(84x84)+(28x84)+(84x28) including cost of copper conductor and other fittings like gasket ,screw , nut and bolt , insulating materials etc.
22Busbar-1&2 04 numbers of 400Amps copper busbar with 1.6A/SQ.MM current carring capacity. 25mm X 5mm busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) for sub pannel
23S/F of CT Coil
24S/F of Indicator lamp with trangular switch
25SITC of digital type multifunction meter for voltage,current,frequency,PF,THD indication with COMPACTIVITY FOR bms data.
26Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m)
27Danger Board.
28Supply and fixing of shock treatement charts duly laminated along with separate colour single line diagram laminated, to be fixed in Electrical control panel room.
29Supply and fixing of first aid box with medicines complete with medicine with three years expiry date to be fixed in Electrical control panel room..
30Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time<25 nanosec in the incommer of Distribution board, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 1 years.
31Supply and fixing of 800A 50KA DPX3 4pole MCCB with Thermal Mangnetic Protecton unit in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required.(Make- Legrand/ ABB/ Simens/ schneider)equivalent)as per direction of Engineer-in-charge
32Supply and fixing of 400A 50KA DPX3 4pole MCCB with Thermal Mangnetic Protecton unit in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required.(Make- Legrand/ ABB/ Simens/ schneider)equivalent)as per direction of Engineer-in-charge
33S/F of 630A On load change over 4pole without cover(Make- ABB/Legrand/ Simens/ schneider)equivalent)as per direction of Engineer-in-charge
34Outgoing - 250A 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release Electrical locking for AC connection ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
35Outgoing - 200A 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release Electrical locking for Main connection ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
36Outgoing - 160A 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release Electrical locking for OT main & 2 no. for DG connection ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
37Outgoing - 63A to 100A 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release Electrical locking for one main & 3 no. for DG connection ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
38FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along
39Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
40Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
41Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
42Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
43Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
44Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
45Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 16 sq. mm copper wire for phase and neutral and 02 nos of single core 10 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X16+2X10)
46Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 25 sq. mm copper wire for phase and neutral and 02 nos of single core 16 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X25+2X16)
474 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
488Way(8+(4x3)+(8x3)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-24 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
49Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
50Supplying and fixing 25Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years.
51Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
52Supplying and fixing 125Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
53Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 70 sq mm
54Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 50 sq mm
55Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5core x 25 sq mm
56Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 4core x 16 sq mm
57Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 4core x 10 sq mm
582core x 10 sq mm
59LAYING OF CABLELaying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
60Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
61Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
62Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.3.5core x 70 sq mm
63Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.3.5core x 50 sq mm
64Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.3.5core x 25 sq mm
65Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.4core x 16 sq mm
66Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.4core x 10 sq mm
67Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.2core x 10 sq mm
68Supply and fixing of Cable Kit joint for joint of two cables as per requirement
69S/F of 80 x 50 mm DLP U PVC Trunking system(Make- Legrand)
70Supply & Installation of 3.3 Kg Manual aerosol based Fire Extinguisher covering 150m3 for big fire (Throwable unit) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x/Equivalent
71Supply & Installation of 60 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 0.6 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x/Equivalent
72Supply & Installation of 30 gm Portable Aerosol based Automatic triggering through linear heat detection cable/electrical initiation Fire Extinguisher (Coverage: 0.3 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. The triggering device should be compatible with linear heat detector to detect heat and should use industrial lithium ion battery with 10 yrs service life to supply electrical power in order to activate the aerosol module.Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x/Equivalent
73Supply and installation of linear heat detection cable compatible with aerosol based fire extinguisher as per the direction of Engineer-in-charge. Make-Pyrogen/Genefire/Stat-x/Equivalent
74Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
75Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57363867
AUTHORITY Government Departments
TENDER VALUE 17.01 Lakhs
LAST DATE 17-09-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Supply And Installation Of New Main Pannel With Fire Supression System To Main Building And Eye Hospital At Dhh Khordha Buildings.
Basic Detail
Tender No TCN-13-26-27
Bidding Type Tender
Location
City Khordha
State Odisha
Key Dates
Publish Date 05 Sep 2026
Submission Date 17 Sep 2026
Open Date 18 Sep 2026
Finance
Tender Value 17.01 Lakhs
Tender Fee 6000
EMD 17100
Exemption Available
Document List
20a1fa07-4a7e-403a-90d9-1ab059b82829.html
BOQ_608211.xls
Tendernotice_1 (16).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

20a1fa07-4a7e-403a-90d9-1ab059b82829.html

xls

BOQ_608211.xls

pdf

Tendernotice_1 (16).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender