Tender For Planning, Design, Engineering, Construction, Fabrication, Supply, Erection, Trial Run And Commissioning Of 2X5mva, 33Kv/6.6Kv Substation Which Includes All The Electrical Outdoor And Indoor Equipment, Lighting System, Earthing System, Ligh
Tender Overview
Project Description
Tender for Planning, Design, Engineering, Construction, Fabrication, Supply, Erection, Trial Run And Commissioning Of 2X5mva, 33Kv/6.6Kv Substation Which Includes All The Electrical Outdoor And Indoor Equipment, Lighting System, Earthing System, Lightning Protection System, Signaling And Control System, Dg Set, Firefighting System, Structural And Civil Works Etc. Including Operation & Maintenance During Defect Liability Period (Dlp Of 60 Months) On Turnkey Basis At Amadand Ocp, J&K Area, Seclnit No. Secl/Bsp/Cmc/E&M/ Amadand Ocp Ss/2026-27/Nit-641, Dtd: 04.09.2026
BOQ
| Sl. No. | Item Description |
| 1 | DESIGN AND ENGINEERING COST (for 2X5MVA, 33kV/6.6kV Substation) |
| 2 | Design and Engg on PLANT & MACHINERY ( P&M - Electrical) inlcusive of Overhead construction cost, Contingencices, but excluding GST |
| 3 | Design and Engg on Civil & Structural work |
| 4 | CIVIL CONSTRUCTION AND STRUCTURAL WORKS for 2X5MVA, 33kV/6.6kV Substation on Turnkey Basis at Amadand OCP, J&K Area inclusive of Insurance,Contingencies but excluding GST |
| 5 | Sub-station Building |
| 6 | Outdoor Steel Structures |
| 7 | Foundation of outdoor structures including Transformer foundation |
| 8 | Cable Trench |
| 9 | Barbed wire fencing |
| 10 | Boundary wall |
| 11 | Surface Dressing |
| 12 | Stone laying |
| 13 | Anti weed treatment |
| 14 | Bore well with submersible pump |
| 15 | Path way |
| 16 | Security Room |
| 17 | RCC sump and Pump House |
| 18 | Room for DG & oil filter unit |
| 19 | Drain along boundary wall |
| 20 | Parking Shed |
| 21 | Oil Overflow Chamber |
| 22 | Oil Drain Pipe |
| 23 | Survey & Soil Investigation |
| 24 | SUPPLY OF PLANT & MACHINERY inclusive of Overhead Construction cost, Insurance, Contingencies, and contigencies on already procured items(supplied by SECL) , but excluding GST for substation 2X5MVA, 33kV/6.6kV Substation |
| 25 | Isolators, 33 kV (nominal),3 poles, pole mounted, 1250A(min.), suitable fault current rating, arrangement for interlocking with 33 kV Vacuum Circuit breaker ( Min. 8 sets) |
| 26 | Isolators, 33 kV (nominal), 3 poles, pole mounted, 1250A(min.), suitable fault current rating, arrangement for interlocking with 33 kV Vacuum Circuit breaker with Earthing switch ( Min. 2 sets) |
| 27 | Isolators, 33 kV (nominal), 3 poles, pole mounted, 1250A(min.) ,suitable fault rating, with D.O. Fuses. (Min. 4 sets) |
| 28 | Lightning Arrestors, station class, 30 kV,10 kA, suitable for 33kV, solidly earthed (each set consists of 3 nos.) with counters/surge monitors (Min. 6 sets) |
| 29 | Single phase current transformer ,outdoor type with required CT ratio for 33 kV system for metering and protection (1 set consists of 3 units for 3 phase supply) Min 5 sets |
| 30 | Potential transformer ,outdoor type 33kV, 100 VA each (each set consists of 3 nos. single phase PT) 33/√ 3 kV/ 110/ √ 3 V for metering and protection each for three phase system (Min. 2 sets) |
| 31 | Vacuum Circuit Breaker, 33kV,1250A, outdoor type, 25 kA min with remote control panel having IDMTL relay for O/L and E/F protection,Digital type microprocessor based power meter, ammeter etc (Min. 1 set) |
| 32 | Neutral Grounding Resistor with required protection (min. 1 set) |
| 33 | Station Transformer , Outdoor Type 160 kVA , 33kV/0.415kV , Cu wound , plinth wound ( Min. 1 no.) |
| 34 | Lighting Transformer , Outdoor Type 100 kVA , 33kV/0.230kV(L-L) , Cu wound , plinth wound ( Min. 1 no.) |
| 35 | 415V ACDB/ Distribution board with minimum 4 nos. MCCBs- (min. 1 set) |
| 36 | Capacitor bank, 6.6kV indoor type (2200KVAR) Suitable Rating kVAR including APFC. (Min. 2 nos.) |
| 37 | Battery (110 V) lead Acid type, 200 AH and battery charging (with one stand bye battery charging unit) equipment, control panels, wooden racks including DCDB etc. ( Min. 1 set.) |
| 38 | Earthing system (Safe Earth Electrode type) including earth pits, required galvanised strips/flats,MS Rod for inter connection etc. |
| 39 | Lightning protection system consisting of spikes, earth pits, galvanised strips/flats, shield conductors etc. |
| 40 | LUMINARIES |
| 41 | Decorative, LED (Suitable rating) light fittings |
| 42 | Suitable rating LED Bulbs for indoor lighting |
| 43 | Tubular steel poles,11m height along with 90 W LED lamps with fittings ( minimum 7 nos.) |
| 44 | Lighting masts, 15m height (Min) along with required nos. of 200 W LED lamps with fittings.(min. one number mast) and Luminaires for Lightning cum Lighting Mast |
| 45 | 90 W LED fitted on substation building(min. 6 nos.) |
| 46 | Emergency lighting system suitable for operation on 110 V DC supply in substation building. |
| 47 | Accessories such as lighting distribution boards, sub lighting distribution boards, junction boxes, individual control cables, PVC conduits/ casings, back up fuses, switches, sockets, ceiling roses, single core PVC cable with copper conductors, flexible wire etc. |
| 48 | CABLES AND ACCESSORIES |
| 49 | HT Power Cable , 6.6kV , Copper Cable |
| 50 | LT Power cable, 1100V grade, PVCSWA, 10 sq. mm.(minimum),3/4 core copper stranded conductors |
| 51 | Outdoor Lighting cable, 1100V, PVCSWA , 2 cores, 10 sq mm (minimum) stranded Al conductors |
| 52 | Outdoor and indoor Control cables, 1100V grade, PVCSWA, not less than 2.5 sq mm , copper conductors of with required number of cores |
| 53 | Wires for internal wiring of illumination, ceiling fans, power sockets etc. 1.5 sq mm and 6 sq mm size, PVC insulated copper conductor cable of 1100 V grade. |
| 54 | Cables for internal control wiring for circuit breakers, CT’s, PT’s, PVC insulated cable 2.5 sq mm size, PVC insulated copper conductor of 1100 V grade |
| 55 | Cable trays, cable racks, binding materials, cable glands/lugs, cable jointing kit, bolts, nuts, washers, termination kit, other accessories etc. |
| 56 | Overhead conductors,Insulators, poles, string bus, ACSR conductors, clamps, terminal connectors, other steel hardware etc for 33 kV sides in the out door yard and 2 pole structure fitted with gang operated AB switch, lightning arrester etc for out going feeders |
| 57 | FIRE FIGHTING SYSTEM |
| 58 | Fire fighting equipment consisting of fire hydrants hose cabinets, hose reels, valves, pipes, fire detection alarming system, Fire extinguishing Automatic system in control room and control panels,High velocity Water spray system for power transformers,diesel pump, electric pump with electricals and cables , jockey pump etc |
| 59 | Supply of portable fire extinguisher system |
| 60 | Sand buckets with stand |
| 61 | MISCELLANEOUS ITEMS |
| 62 | Room air conditioners (each having minimum 1.5 t capacity, 5 star rating dual inverter compressor type ) including servo stabilizer |
| 63 | Supply of 75 kVA Diesel Generator set (silent type) with 3 ph, 50 Hz ,415 V output supply with cable, change over switch and earthing etc (Min. 1 no.) |
| 64 | Exhaust fans |
| 65 | BLDC Ceiling fan ,1200 mm sweep along with electronic regulator (5 star rating) |
| 66 | Water cooler with water purifier (min 20 Ltr storage & 20 LPH cooling capacities) Min. 1 no. |
| 67 | Industrial Vacuum Cleaner Set of suitable capacity (Min. 1 no.) |
| 68 | LOTO station system/kit-1 no. , Electrical Layout/Single Line Diagram Board , Electrical shock treatment Chart , Do's & Don’t Chart , Earth pit connection diagram with retro refractive radium type display , Danger plates , Furniture & fittings and insulating mat, Spare and tool & tackles kit, First Aid chart & box, tool box, caution board, keyboard etc and Any other item not specifically mentioned but required essentially for completion/successful commissioning of the project and complaince to DGMS guidelines |
| 69 | Erection and commissioning of Plant and Machinery for substation to be suplied by bidder as above & already procured items (supplied by SECL) inclusive of Overhead Construction cost, Insurance, Contingencies , but excluding GST |
| 70 | Training of O&M staff |
| 71 | Store cost for maintenance of all P&M items of the Substation (supplied by the contractor and supplied by SECL) and Cost of Operation & Maintenance during Defect Liability Period (DLP) of five years.(The rate quoted against the DLP shall be 30.72% of total contract value quoted by the bidder excl GST) |
| 72 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender