Tender For Repair And Maintenance Works In The Institute Guest House, At Nit Kurukshetra.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Sep 2026
11 days left
EMD
86100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kurukshetra → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Works In The Institute Guest House, At Nit Kurukshetra.
BOQ
| Sl. No. | Item Description |
| 1 | Earth Work |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 3 | All kinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 5 | All kinds of soil. |
| 6 | CONCRETE WORK |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 11 | Foundations, footings, bases for columns |
| 12 | Columns, piers, abutments, pillars, posts and struts |
| 13 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). |
| 14 | REINFORCED CEMENT CONCRETE |
| 15 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 16 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 18 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | STEEL WORK |
| 20 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 21 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 22 | Hot finished welded type tubes |
| 23 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 24 | FLOORING |
| 25 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 26 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 27 | Size of Tile 600 x 600 mm |
| 28 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 29 | Size of Tile 600x600 mm |
| 30 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). |
| 31 | Size of Tile 600x600 mm |
| 32 | ROOFING |
| 33 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 34 | FINISHING |
| 35 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 36 | 1:6 (1 cement: 6 fine sand) |
| 37 | Pointing on brick work with cement mortar (1:3) : |
| 38 | Flush / Ruled/ Struck or weathered pointing |
| 39 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: |
| 40 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.93 litre/10 sqm |
| 41 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 42 | Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surfacesmooth including necessary repairs to scratches etc. complete. |
| 43 | REPAIRS TO BUILDING |
| 44 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 45 | DISMANTLING AND DEMOLISHING |
| 46 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 47 | In cement mortar |
| 48 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): |
| 49 | From brick work in cement mortar |
| 50 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 51 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 52 | Road Work |
| 53 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. |
| 54 | 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 55 | Electrical works |
| 56 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 57 | Above 35 sq. mm and upto 95 sq. mm |
| 58 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. |
| 59 | 3½ X 95 sq. mm (45mm) |
| 60 | NON SCHEDULE ITEM |
| 61 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 10 in exposed brick work in complete in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 62 | Above plinth level upto floor V level |
| 63 | Brick work with old bricks in exposed brick work in complete in cement mortar 1:6 (1 cement : 6 coarse sand) above plinth level upto floor V level |
| 64 | Providing and fixing 10mm thick frameless toughened glass partition & door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & connetors fixing arrangement and making necessary holes etc. for fixing required door fittings including door handle, lock and stopper etc. Filling the gap in between glass & walls with silicone all complete as per direction of Engineer in charge. |
| 65 | Providing and fixing UV stabilized HDPE pigeon protection net of approved quality, 25 mm x 25 mm mesh size, 1.0–1.5 mm thick twine, transparent/white colour, fixed with wire rope (3–4 mm dia) around the periphery, including mild steel eye bolts, fasteners, nylon cable ties, stretching, tying, scaffolding, all labour, tools & tackles, complete as per directions of Engineer-in-Charge. |
| 66 | Supplying and fixing of draped with 900 gsm, water proof, washable, Fire retardant,dust repellent and mildew resistant Tensile membrane Teflon coated PVDF material. |
| 67 | Supplying of following sizes XLPE insulated and PVC sheathed aluminum conductor armoured power cable of 1.1 kV grade as required. |
| 68 | 3½ X 95 sq. mm (For essential supply from Main Panel Guest house to panel of 62.5 kva Generator |
| 69 | Shifting of 62.5 kva DG in Guest House Distance up to 50mtr Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender