Tender For annual repair maintenance Electrical And Mechanical Services At Nes Ed-M-251, Delhi (Sub Head:- Renovation & Upgradation Of Electrical & Mechanical Services At Ne Circle -M-21)
Tender Value
74.13 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
9 days left
EMD
1.48 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for annual repair maintenance Electrical And Mechanical Services At Nes Ed-M-251, Delhi (Sub Head:- Renovation & Upgradation Of Electrical & Mechanical Services At Ne Circle -M-21)
BOQ
| Sl. No. | Item Description |
| 1 | Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB, Camera should display Camera title, Date & Time in live & recorded video2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.3) Compression (Minimum): Video:- H.265 or better, H.265, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.7234) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming, configurable Main stream: 4MP (2560×1440) 25/30fps Sub streams minimum: 720P@ 25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Securit6 x 4 sq. mmy: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade................CONT.................... |
| 2 | 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.10) Recording Management: Format SD, overwrite, storage management, video to NAS device,11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,13) System Capability: ONVIF, Camera shall support open source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing)20) IR life: 40000 hours or higher21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS...........................Cont......................... |
| 3 | 4MP @ 25/30fps@1440P (2560x1440) Outdoor Bullet Camera with 2.8/3.6/6/8/12 mm fixed lens(as per site requirement). |
| 4 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth. 2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot.6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS2327) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0)8) Video Output Ports: 1x HDMI and 1 VGA9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS and BIS Certified......................CONT..................... |
| 5 | 14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply.15) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)16) The VMS, NVR application shall support all the features & functionalities of the offered cameras.17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Resolution: 7680x4320 (8K), 3840*2160, 1920×1080, 1280×1024,1280×720, 1024×768 21) Must support recording resolution upto 32MP22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. ......................CONT.................................. |
| 6 | When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file.26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan 28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 29) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.31) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. |
| 7 | 32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc. vehicle attributes.33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics16 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 8 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. |
| 9 | 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. |
| 10 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 11 | 6 U Rack |
| 12 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2- standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. |
| 13 | 1 Run Cable |
| 14 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recesses including cutting the wall and making good the same in case of recessed conduit as required. |
| 15 | 25 mm |
| 16 | Supplying, Installation, Testing and Commissioning following capacity Surveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 17 | 4 TB (Terabytes) |
| 18 | Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with3840x2160 resolution or better, USB playback, Bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+,brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc.as required. |
| 19 | 32 inch or larger LED Display |
| 20 | Supply, Installation, Testing, and Commissioning of a 40.7 kW Rooftop Hybrid On-grid Solar Photovoltaic (SPV) Power Plant, including all necessary components Components and Installation:Connections of AC Control Panel including all internal wiring, breakers, protections, and metering. Copper Cabling of appropriate sizes: From PV modules to the DC combiner panel not less than 4 Sqmm tinned single copper DC cables . From AC panel to net meter (as per actual site length). GI Conduits/ Enclosures for all wiring throughout the project. No PVC, CPVC, ABS, or any plastic material will be used for wiring, junction boxes, or cable routing. ESE Type Lightning Arrester with 16 sqmm Copper cable and Chemical Earthing Electrode. Earthing: Chemical copper earthing electrodes shall be provided with GI strip for connection from electrode to equipment’s and structure. Separate earthing systems will be maintained for: ESE Lightning ArrestersDC SideAC SideModule Mounting Structures Surge Arresters and other protective devices as per applicable norms.Foundations and Structures:Hot dip galvanized iron (HDGI at least 80 micron) mounting structures shall be installed suitable for wind speed upto 180Km/h. Walkways will be provided on the high-rise structure to allow safe and convenient maintenance access.Additional Requirements:................Cont................... |
| 21 | All installation work should comply with relevant safety codes, as per BIS, IEC & MNRE gaidelines national standards, and site-specific conditions or as per direction of Engineer-in-Charge. Testing and commissioning to be carried out in the presence of the Engineer-in-Charge.Any other accessories or components required to ensure a fully operational and compliant solar PV plant shall be included in the scope.CONTINUOUS KW CAPACITY: 40.7 KW Grid tied systemARRAY CONFIGURATION: As per standard Wattage of modulesOUTPUT VOLTAGE: 415V, 50Hz to be feed into the grid INVERTER EFFICIENCY: 98% and Above having minimum 12 year WarranteeSOLAR MODULEPhotovoltaic (PV) Modules:The solar photovoltaic system shall utilize Top-Con Bifacial N-Type Dual Glass Modules with a minimum power rating of 590 Watt or higher. These high efficiency solar modules shall conform to the latest applicable standards, including IS 14286 / IEC 61215,IS/IEC 61730 Part-1 and Part-2, or any relevant amendments in force at the time of installation.Each PV module must be equipped with a Radio Frequency (RF) identification tag for traceability and monitoring.Key specifications of the modules include:Photoelectric conversion efficiency of ≥ 22.87% Capability to perform satisfactorily under relative humidity up to 100% Operating temperature range: - 10°C to +65°C Designed to withstand wind gusts up to 180 km/h from the rear side of the panel ............................CONT................................................. |
| 22 | Appropriate interconnection cables shall be provided to ensure secure and efficient connectivity between solar modules. All equipment shall be suitable for outdoor installation and comply with environmental and mechanical durability requirements for long-term performance .PV Module Specifications and Protections: Appropriate surge protection devices shall be installed at the PV module level to safeguard against voltage spikes and transient surges. Each PV module shall carry a performance warranty guaranteeing: Minimum 90% of the rated output wattage at the end of 10 years Minimum 80% of the rated output wattage at the end of 25 years The modules shall feature: A front cover made of high-transmission (>91%) tempered and textured glass with anti-reflective (AR) coating, having a minimum thickness of 3.2 mm A durable anodized aluminium alloy frame to protect the silicon cells from mechanical damage and environmental exposure Additional technical requirements: Fill factor shall not be less than 0.70 Modules shall be installed at an optimal tilt angle and alignment to ensure maximum annual energy generation Typical open-circuit voltage (Voc): 52.7 V DC Short-circuit current (Isc): Not less than 14.17 A The modules shall be capable of withstanding a high voltage insulation test of 3 kV DC (rms) for 1 minute All modules and associated components shall meet the environmental and electrical safety standards necessary for long-term, reliable performance.The junction box weather proof fabricated of 2 mm thick CRCA sheet for out door application suitable for roof top SPV panel complete with all accessories, IP 65 String Combiner BOX with required Input and Output, suitable rating DC/AC MCBs and MCCBs, with AC/DC SPDs etc. as reqd. as IEC 62208 or relevant BIS & made of rust proof metal. The terminals shall be connected to copper bus bar arrangement of reqd. size & junction box shall be fitted with cable glands as per reqd. cable size for both incoming & outgoing cable. |
| 23 | MODULE MOUNTING STRUCTUREStructure Design: Low-Height Structure (C-Channel Based): a. Constructed using C-Channels of suitable dimensions with a minimum thickness of 2 mm b. Hot Dip Galvanized for corrosion resistance c. Design as per the attached structural drawing / specification Hot Dip Galvanized Iron (HDGI) pipes for vertical columns c. 2-inch HDGI pipes with a minimum thickness of 2 mm to be used for rafters and purlins in a scissors truss arrangement d. Structure must include a fabricated walkway for safe and convenient access, ensuring ease of maintenance and serviceability All steel/Iron components shall be Hot Dip Galvanized to prevent corrosion and ensure long-term durability in outdoor conditions. The design must comply with relevant Indian standards and sitespecific structural safety norms.The fasteners, nut and bolts should be made of good quality stainless steel (304 Grade).The structures should be designed to allow easy replacement of any module.For Low Rise Structure The minimum clearance of the lowest part of the module structure and the developed ground level shall not be less than 500mm i/c providing appropriate space between row of panels for cleaning the panels & servicing. For High Rise Structure The minimum clearance of the lowest part of the module structure and the developed ground level shall not be less than 10 Ft i/c providing appropriate space between row of panels for cleaning the panels & servicing. PCC foundation as per requirement include in the item. For covering the electrical wires appropriate size covered GI chanels will be used. |
| 24 | Power Conditioning Unit (PCU) / Hybrid Inverter – 40 kW40 kW Three-Phase Hybrid( bi-directional, grid interactive ) Power Conditioning Unit (PCU) / Central Control string Inverter shall be provided for solar photovoltaic system operation with battery storage and grid interaction.The PCU/ Hybrid Inverter shall be capable of converting DC power generated from solar PV modules and battery systems into AC power suitable for feeding into the LT grid and supplying connected loads in grid-connected, hybrid, and backup modes.General Requirements Rated capacity: 40.7 kW, three-phase Grid-interactive, hybrid type inverter suitable for on-grid, off-grid, and battery-assisted operationSuitable for operation with high-voltage lithium-ion battery systems Capable of seamless transition between grid-connected and backup modes Provision for generator input / AC coupling, wherever requiredTechnical FeaturesEquipped with Maximum Power Point Tracking (MPPT) to ensure maximum energy harvesting from the solar PV array. Minimum two independent MPPT channels, capable of handling string mismatch and partial shading conditions Compatible with DC input voltage up to 1000 V Capable of 100% three-phase unbalanced output, allowing independent phase loading Provision for parallel operation with similar inverters for system expansion and redundancy Built-in energy management logic to prioritize solar, battery, grid, and generator sources Battery Integration Compatible with high-voltage lithium-ion battery..................Cont........................... |
| 25 | (LiFePO4) banks Battery voltage operating range suitable for hybrid operation Bi-directional charging and discharging with controlled current limits Communication with battery management system (BMS) through standard protocols Configurable charging and discharging schedules for peak-shaving and backup operation, multiple MPPT with wide voltage range; maximum efficiency>= 97.5%,Grid & Power: Quality Output voltage and frequency fully compatible with local LT grid (415 V, 50 Hz), Power factor adjustable within permissible limits Total Harmonic Distortion (THD) < 3%, Anti-islanding protection to ensure safety during grid failure, seamless changeover to backup mode(<20 ms) on grid failure, Capability to operate under variable grid conditions common in Indian distribution networks.Monitoring & ControlIntegrated monitoring for: DC input parameters, AC output parameters, Battery status, Faults and alarms, Provision for remote monitoring and data logging, Event and fault history storage for operation and maintenance purposes.Protection & SafetyThe PCU shall include integrated protection systems, including but not limited to: Anti-islanding protection, DC reverse polarity protection, Insulation resistance monitoring, Residual current monitoring, AC over-current and short-circuit protection, Surge protection on DC and AC sides.......................CONT.................................. |
| 26 | Environmental & MechanicalSuitable for outdoor installation Enclosure protection class minimum IP65. Operating temperature range suitable for Indian climatic conditions. Cooling arrangement through intelligent / forced or natural cooling, as applicable. Wall-mounted type with necessary mounting accessoriesStandards & ComplianceThe PCU shall conform to the latest applicable IEC / IS standards, including but not limited to: IEC / IS 61683 (Efficiency measurement), IEC 60068-2 series (Environmental testing), IEC 61727 / IEC 62116 (Grid interconnection and anti-islanding), IEC / EN 62109 (Safety of power converters)Any other relevant BIS / IEC standards applicable at the time of installation.Warranty: Minimum 5 years warranty on the inverter |
| 27 | Battery Energy Storage System (BESS)Providing, supplying, installing, testing and commissioning of Lithium Iron Phosphate (LiFePO₄) Battery Energy Storage System of minimum 40 kWh suitable for integration with 40 kW Hybrid Solar Inverter, complete with battery rack, interconnecting cables, protection devices, communication accessories, and monitoring system, as per approved drawings, manufacturer’s recommendations, and directions of Engineer-in-Charge.Battery Chemistry :Lithium Iron Phosphate (LiFePO₄), maintenance-free, deep cycle typeBattery Capacity & Configuration: Minimum 40 kWh total nominal energy capacity achieved by installing adequate no of LiFe PO₄ battery units, Batteries shall be modular and scalable, suitable for parallel operationNominal Voltage & Operating Range : Nominal battery voltage around 51.2 V DC, Operating voltage range approximately 44.8 V – 57.6 V DCDepth of Discharge (DoD): Minimum 80–90% usable DoD, without affecting cycle lifeBattery Management System (BMS): Inbuilt advanced BMS with active protection for Over-charge, Over-discharge, Over-current, Short circuit, Over-temperature.Cycle Life : Minimum 6000 cycles at 25°C at recommended DoDEnclosure & Protection: Robust metal enclosure with minimum IP rating as per manufacturer catalog Suitable for indoor installation with adequate ventilation |
| 28 | Battery Rack & MountingBattery Rack : MS powder-coated / galvanized floor-mounted battery rack suitable for battery units Rack shall be corrosion-resistant, rigid, and capable of bearing full battery load with safety factorMounting Type : Floor-mounted / stack-mounted arrangement as per site conditions and manufacturer guidelinesWarranty : Minimum 5 years comprehensive warranty on batteries |
| 29 | Supply, Installation, Testing and Commissioning of Battery DC Distribution / Protection Box comprising suitably rated DC isolator / breaker, DC fuses and Type-II DC SPD for the battery circuit, housed in an IP65 enclosure with cable glands and interconnections, as required. Suitable for integration with 40 kWh battery bank as per site conditions and direction of Engineer-in-Charge. |
| 30 | Supplying and laying of battery interconnect DC power cable (electrolytic copper, suitably rated for battery charge / discharge current) between the battery bank and the hybrid inverter, complete with copper lugs, glands and terminations (lump-sum for the 40 kWh battery system), as required. |
| 31 | Supplying, Installation, Testing and Commissioning of DC Distribution Box (DCDB) suitable for 30A solar DC input, comprising high-quality DC fuses, Type-II DC Surge Protection Device (SPD), suitably rated isolators (where required), internal copper busbars and all interconnections, housed in an IP65/IP67 weatherproof, dustproof, termite-proof and UV-resistant outdoor enclosure, complete with cable glands, protection hardware and mounting accessories, suitable for integration with the 40.7 kWp Solar PV array and hybrid inverter system, as per site conditions and Engineer-in-Charge directions. |
| 32 | Supplying and laying of DC 6 sq.mm Cable, UV protected, with lowest conductor resistance and high mechanical strength for varying weather conditions. Electrolytic grade 99.99% pure copper, oxygen index more than 30%, virgin FR grade PVC, electrolytic multi-strand annealed tinned copper conductor, EBXL compound insulation and UV-protected XLPO compound sheathing, complete as required. |
| 33 | Supply, Installation, Testing & Commissioning of Lightning Arrestor meeting NFC 17-102 & UNE 21186 standards, tested to withstand multiple 40 kA impulses, with high quality anti-corrosive and conductive coating, low wind resistance and light weight, with accessories i.e. 25mm x 3mm GI strip, GI connectors etc., suitable for the 40 kWp Solar Power Plant, complete as required. |
| 34 | Supply, Installation, Testing & Commissioning of long-life Maintenance-Free Earthing System. Copper Bonded Steel rod, 25 mm dia, 10 feet length, mild-steel core molecularly bonded with min. 250 micron coating of 99.99% pure electrolytic grade copper, exothermically welded Cu busbar 50x6x200 mm (CPRI tested, 25 kA), earth enhancement compound (RoHS, IEC 62561-7, min. 50 kg in 10 kg x 5 sealed bags, resistivity < 0.12 ohm-metre), suitable poly-plastic lockable pit cover, incl. petty material to complete the job in all respects. |
| 35 | Providing, supplying, installing, testing and commissioning of AC Distribution Board (ACDB) suitable for grid-connected / hybrid solar power system, fabricated out of 1.6 mm thick CRCA sheet steel, dust and vermin proof, wall-mounted / floor-mounted type, powder-coated finish, complete with the following:Main Incomer: 4 Pole, 125 Amp, 36 kA MCCB, Ics=100% = Icu, operation voltage 690 V conforming to IS/IEC 60898 / 60947, suitable for 415V, 50 Hz, complete with shrouds and phase identificationSurge Protection Device (SPD): Type-II Surge Protection Device, 3P+N configuration, suitable for 415V AC system, with visual indication and replaceable cartridge, conforming to IEC 61643, complete with internal MCB / fuse protection. (Rating selected to suit the 40 kWh hybrid inverter AC out put) |
| 36 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 37 | Hot finished welded type tubes |
| 38 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 39 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 40 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 41 | 3 x 1.5 sq. mm |
| 42 | 3 x 4 sq. mm |
| 43 | 6 x 4 sq. mm |
| 44 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the walland making good the same in case of recessed conduit as required. |
| 45 | 20 mm |
| 46 | 25 mm |
| 47 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 48 | 6 way (4 + 18), Double door |
| 49 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 50 | Single Pole |
| 51 | Supplying and fixing Four pole 63A rating 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 52 | Providing and fixing pole box of size 250mm X 200mm X 105mm with side openable hinged cover complete with two strip aluminium bus-bar of 100 amps capacity mounted on DMC bus support and 1 no. of SPMCB of 6 amps 'C' series capacity with din rail on the existing street light pole with the help of two nos. MS clamps of suitable size, including making hole to insert the cable and dismantling the worn out MS box etc. complete as required. |
| 53 | Supplying, Assembling, Erection and installation of continuously tapered multi faced and polygon cross-section of 16 mtr. high mast shaft with suitable size base plate complete with S/F twin dome aviation obstruction lights with two nos. 12 watt. LED Lamp with all other provisions for execution in conformation with detail technical specification:-a) The mast shaft shall be in section of suitable sectional lengths with slip joints b/w various sections without any circumpherial welding hot dipped galvanized inside and outside in single dip, suitable for wind velocity as per Is : 875 part-IIIb) Double drum winch provided with raising and lowering device suitable for operation with portable power tool for electrical operation with a remote control switch.c) Separate handle for manual operation of winch with a torque limiting device for safe ducking of carriage.d) Raising and lowering type lantern carriage designed to carry 12 nos. flood light fittings symmetrically mounted luminaries, control gear box, junction box and top pulley assembly with weather proof cover.e) 3 wire suspension system with steel wire rope of suitable size not less than 6 mm dia.f) Flexible copper power cable for connection of suitable size.g) Hinged service door in bore section, bore plale, earthing terminals.h) One no. heavy duty 1.2 mtr long hot dipped galvanized lighting finial i). Supply of Foundaction bolts manufactured from special steel along with nuts, washers, anchor plates & templates.j). Bottom dia:- 360 mm, Top Dia:- 150 mm, Sheet Thikness:- 3.3 mm |
| 54 | Providing and laying in position (1:2:4) reinforced cement concrete foundation of size 900 mm (L) x 900 mm (W) and 3000 mm (D) i/c excavation of earth, Filling of earth, centring & shuttering of form work of foundation & Providing cutting, bending and placing in position, reinforcement cold twisted bars of 25 mm dia 3000 mm long (approx.) -12 nos. and reinforcement ring of TMT bars of 8 mm dia-3200 mm (approx.) - 20 nos. (with 150 mm spacing) as required, providing 90 mm (O.D) DWC/ HDPE pipe for cable entry and exit as required etc. complete as reqd. |
| 55 | SITC of Outdoor type totally enclosed weather proof compartmentalised feeder pillar of following sizes and depth not less than 300 mm, fabricated with 2 mm thick CRCA / MS sheet with base frame fabricated from 40 x mm x 40 mm x 5 mm thick MS angle iron suitable for 415/ 500 volts 50 Hz A.C. supply with MS sheet on bottom for taking load of cable gland necessary individual gland plates for cable gland, hinged front openable double leaf door with locking arrangement complete with bus bar chamber having 100 amp TPN Alu. bus bar and the MS cover, covering the MCCB's / MCB's and aluminium strips etc. as reqd. (only MCCB's knobs shall be visible) i/c supplying and fixing the following mounting inside the feeder pillar - interconnections with suitable size Al. bus bar / Copper wire for outgoing and incoming MCB's/ MCCB's/ connector, earthing studs, powder coating/ stove enameled painting after 7 tank treatment process, suitable size CC foundation i/c covering the panel by painted wiremesh with central lock etc. as reqd. (not less than 0.54) having provision of incoming 32 amp TPN MCB, single dial time switch and outgoing Contactor for automatic switching on and off luminaries, 9 Amp Two contactors and raise lower push buttons for motor operation etc as required. |
| 56 | Supplying and Fixing 450 mm dia 1400 RPM heavy duty exhaust fan suitable for operation on 230 volt, ±10%, 50 Hz supply to fixed on wall i/c connection with 1.5 Sq.mm PVC single core cable i/c testing etc. as reqd. |
| 57 | Supplying & Fixing of Flood light, powder coated pressure die cast aluminium body with uilt in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, river efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage rotection, EMI-EMC as per CISPR-15, lenses for beam angle 30 eg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant IS standard complete in all respect i/c external connections ith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output. LM79 & LM80 Test report and all testing equired for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 58 | 70 Watt LED Flood Light, powder coated pressure die cast aluminium System lumen efficacy ≥120 and <135 lm/Watt). |
| 59 | 200 Watt LED Flood Light, powder coated pressure die cast aluminium System lumen efficacy ≥120 and <135 lm/Watt). |
| 60 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 61 | Supplying & Laying of one Number Following size XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with ammendment No. 1 in following manners. |
| 62 | 2 x10 sq. mm (in the existing masonry open duct/cable tray as required) |
| 63 | 4 x25 sq. mm (in the existing masonry open duct/cable tray as required) |
| 64 | 3.5x70 sq. mm (in the existing masonry open duct/cable tray as required) |
| 65 | 3.5 x 120 sq .mm(in the existing masonry open duct/Cable tray as required as required) |
| 66 | Supplying & Laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with ammendment No. 1 in following manners. |
| 67 | 2x10 sq. mm (on wall surface as required.) |
| 68 | 4 x 25 sq. mm (on wall surface as required.) |
| 69 | 3.5 x 70 sq. mm (on wall surface as required.) |
| 70 | 3.5 x 120 sq. mm (on wall surface as required.) |
| 71 | Supplying & Laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with ammendment No. 1 in following manners. |
| 72 | 2 x 10 sq. mm (in RCC/Hume/Metal/DWC pipe as required.) |
| 73 | 4 x 25 sq. mm (in RCC/Hume/Metal/DWC pipe as required.) |
| 74 | 3.5x 70 sq. mm (in RCC/Hume/Metal/DWC pipe as required.) |
| 75 | 3.5 x 120sq. mm (in RCC/Hume/Metal/DWC pipe as required.) |
| 76 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 77 | 2x 10 sq. mm (19mm) |
| 78 | 4x 25 sq. mm (38mm) |
| 79 | 3½ X 70 sq. mm (38mm) |
| 80 | 3½ X 120 sq. mm (45mm) |
| 81 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc. as required. |
| 82 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 83 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 84 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 85 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 86 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 87 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. |
| 88 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required |
| 89 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 90 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 91 | Supplying installation, Testing & commissioning of indoor type cubical LT Panel depth not less than 300 mm, fabricated with 2 mm thick CRCA sheet suitable for 415/ 500 volts 50 Hz A.C. supply with CRCA sheet on bottom for taking load of cable gland necessary individual gland plates for cable gland, cable alley, MS angle iron frame 40mm x 40 mm x 5 mm, locking arrangements as per direction of engineer in charg complete with bus bar chamber having 400 Amp TPN Al busbar duly sleeved and Numbering, i/c supplying and fixing the following mounting inside the panel - interconnections with suitable size Al. bus bar/copper cable for suitable size for following outgoing and incoming MCCB’s, earthing studs, powder coating/ stove enamelled painting after 7 tank treatment process, arrangement with following accessories as reqd. of (not less than 1.80 Sqmtr)a)Incoming 250 Amp 36 KA 4P MCCB with Thermal Magnetic release with Phase barriers and spreader terminals complete with connections etc. as required-1 Nos. b) Outgoing 125 Amp 25 KA 4P MCCB with Thermal Magnetic release with Phase barriers and spreader terminals complete with connections etc. as required- 6 No d) Multifunction meter with suitable CT ratio – 1set. e) RYB LED indicator with control accessories- 1 Set |
| 92 | Supplying installation, Testing & commissioning of indoor type cubical LT Panel depth not less than 300 mm, fabricated with 2 mm thick CRCA sheet suitable for 415/ 500 volts 50 Hz A.C. supply with CRCA sheet on bottom for taking load of cable gland necessary individual gland plates for cable gland, cable alley, MS angle iron frame 40mm x 40 mm x 5 mm, locking arrangements as per direction of engineer in charg complete with bus bar chamber having 800 Amp TPN Al busbar duly sleeved and Numbering, i/c supplying and fixing the following mounting inside the panel - interconnections with suitable size Al. bus bar/copper cable for suitable size for following outgoing and incoming MCCB’s, earthing studs, powder coating/ stove enamelled painting after 7 tank treatment process, arrangement with following accessories as reqd of (not less than 1.80 Sqmtr)a)Incoming 125 Amp 36 KA 4P MCCB with Thermal Magnetic release with Phase barriers and spreader terminals complete with connections etc. as required-1 Nos. b) Outgoing 63 Amp 36 KA 4P MCCB with Thermal Magnetic release with Phase barriers and spreader terminals complete with connections etc. as required-5 Nos. c) 63 Amp FP MCB – 5 set. d)5-32 Amp DP MCB – 5set.e) Multifunction meter with suitable CT ratio – 1set. f) RYB LED indicator with control accessories- 1Set |
| 93 | Supplying and fixing of 125 Amp four pole on load change over switch, operated on 415 Volts, 50 Hz with sheet enclosure weather proof side handling operated & fixing by Angle iron, nut & bolts etc. complete etc. as reqd. |
| 94 | Supplying and fixing of 125 Amp Four pole Automatic Transfer switch, operated on 415 Volts, 50 Hz with sheet enclosure weather proof side handling operated & fixing by Angle iron, nut & bolts etc. complete etc. as reqd. |
| 95 | Supplying and fixing of 63 Amp four pole Automatic Transfer switch, operated on 415 Volts ,50 Hz with sheet enclosure weather proof side handling operated & fixing by Angle iron, nut & bolts etc. complete etc. as reqd. |
| 96 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). |
| 97 | 1.5 TR with 5 Star BEE Rating |
| 98 | Supplying and Fixing of 5 KVA Stabilizer used upto 2 Tr Air conditioner having voltage range (170-270 Volt) wall mounted type, auto start & fixing by Angle iron, nut & bolts etc. complete etc. as reqd. |
| 99 | Supplying & Fixing of 45 watt Post Top lantern fitting, powder coated pressure die cast aluminium body having minimum efficacy 100 lm/watt ,Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 4 KV L,N,E as per IEC 61000-4-5, ,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-65,IK-5, CRI >70, CCT 3000°K / 4000°K / 700°K /6500°K (As per ANSI Bin), Fixture shall be of relevant IS standard complete in all respect i/c external connections ith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 100 | Credit for old dismantle materials |
| 101 | Faulty Panel along with switch gear |
| 102 | Dismantled AC |
| 103 | Dismantled stabilizer |
| 104 | Dismantled Exhaust Fan |
| 105 | Assorted aluminium Cable |
| 106 | Note:- During the preparation of any running or final bill by the contractor it is essential that the contractor shall submit GST paid invoice, E-way bill and delivery challan for all items without these documents the bill will not be considered submitted in proper form & shall be returned back to the contractor by Junior Engineer (E). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 05, 2026
11:30 IST
Tender Published
Tender notice published.
TodaySep 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysSep 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender