Tender For Special Repair To Convert Old Overhead Acsr Line Into Lt Underground Cable Alongwith Panels At Certain Location At Hattigor Under Ge Rangia
Tender Overview
Project Description
Tender for Special Repair To Convert Old Overhead Acsr Line Into Lt Underground Cable Alongwith Panels At Certain Location At Hattigor Under Ge Rangia
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Sep-2026 | Schedule of Credit | Other | 26-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of LT over head ACSR conductor of any size removing conductor from site complete all as specified and as directed. |
| 2 | Dismantling of LT over head insulator of any size and removing the insulator for site complete all as specified and as directed. |
| 3 | Dismantling of cross arms/clamp/nuts/bolts fixed on Steel tubular poles carefully and removing unserviceable cross arms from site complete all as specified and as directed. |
| 4 | Dismantling of stay assembly complete. (Demolition of concrete, etc and excavation measured separately) all as specified and as directed. |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft / loose soil complete all as specified and as directed. |
| 6 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil after the pipes/fittings are laid/fixed jointed and tested complete all as specified and as directed. |
| 7 | Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5 mtr from the starting point complete complete all as directed as specified. |
| 8 | M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm including spreading thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. |
| 9 | Supply and laying sub class B bricks of size 230x125x73mm (+/- 10% tolerance limit) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 10 | Supply, laying, jointing and testing LT underground electric power cable crossed linked XLPE insulated, two or more core galvanized steel strip or wire armoured / PVC insulated armoured cable heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 150 sqmm 3.5 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipes etc fixing and connecting accessories such as Aluminium cable lugs, cable glands, nut, bolts, washers etc complete all as specified and as directed.Note: Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items. |
| 11 | All as per item No. 10 here-in-before but of 120 Sqmm, 3.5 Core. |
| 12 | All as per item No. 10 here-in-before but of 35 Sqmm, 3.5 Core. |
| 13 | All as per item No. 10 here-in-before but of 25 Sqmm, 3.5 Core. |
| 14 | All as per item No. 10 here-in-before but of 16 Sqmm, 4 Core. |
| 15 | All as per item No. 10 here-in-before but of 16 Sqmm, 2 Core. |
| 16 | All as per item No. 10 here-in-before but of 10 Sqmm, 2 Core. |
| 17 | Supplying and fixing Galvanised mild steel pipe/tubing, light grade complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed. |
| 18 | Supplying and fixing Galvanised mild steel pipe/tubing, light grade complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed. |
| 19 | Supplying and fixing Galvanised mild steel pipe/tubing, light grade complete with all fittings of 80 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washers as in cable protection complete all as specified and as directed. |
| 20 | M&L for Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface / footpath with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item. |
| 21 | Supply and fixed in repair single run 3 core, 1.50 sqmm nominal cross sectional area multistranded copper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLSH) heavy duty cable PVC insulated and PVC sheathed from pole junction box to light fitting complete all as specified and as directed. |
| 22 | S&F of thermoplastic polycarbonate cable terminal box of size 250mm x 200mm x 100mm, IP 66 protection, screw cover top type, suitable for 16 sqmm, 4 core cable, 3P+N incoming/outgoing cable and P+N PVC sheathed connection cable for light fitting, having DIN rail mounting arrangement for holding SPN MCB, with and including SPN MCB 10 Amp, cable junction terminals, IP 55 cable glands of suitable size for cable entry/out and 02 nos of MS clamps and 04 nos of mounting brackets, including all fixing accessories etc, complete all as specified and as directed. |
| 23 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Bus bar Panel Board of suitable size 1100 x 900 x 450 mm, fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos, Digital ammeter 0-500 Amps with selector switch, digital voltmeter of 500 Volts with selector switch and LED/Neon type indicating lamps panel mounting type RYB-3 Nos, internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following:- (a) Internal wiring with 6 sqmm single core copper conductor cable/PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1 Job. (b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. INCOMING(c) MCCB 125 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUTGOING(d) MCCB 100 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (e) MCCB 63 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (f) MCB Single Pole & Neutral (SPN) 40 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (g) MCB Single Pole & Neutral (SPN) 32 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-04 Nos. (h) MCB Single Pole & Neutral (SPN) 10 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos.Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication. |
| 24 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Bus bar Panel Board of suitable size 900 x 800 x 450 mm, fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos, Digital ammeter 0-500 Amps with selector switch, digital voltmeter of 500 Volts with selector switch and LED/Neon type indicating lamps panel mounting type RYB-3 Nos, internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following:- (a) Internal wiring with 6 sqmm single core copper conductor cable/PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1 Job. (b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. INCOMING (c) MCCB 100 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.OUTGOING(d) MCCB 40 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No.(e) MCB Triple Pole & Neutral (TPN) 25 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (f) MCB Single Pole & Neutral (SPN) 40 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-04 Nos. (g) MCB Single Pole & Neutral (SPN) 32 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-05 Nos. (h) MCB Single Pole & Neutral (SPN) 10 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication. |
| 25 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Bus bar Panel Board of suitable size 700 x 600 x 450 mm, fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos, Digital ammeter 0-500 Amps with selector switch, digital voltmeter of 500 Volts with selector switch and LED/Neon type indicating lamps panel mounting type RYB-3 Nos, internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following:- (a) Internal wiring with 6 sqmm single core copper conductor cable/PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1 Job. (b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. INCOMING (c) MCCB 40 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUTGOING(d) MCB Single Pole & Neutral (SPN) 40 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (e) MCB Single Pole & Neutral (SPN) 25 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-04 Nos. (f) MCB Single Pole & Neutral (SPN) 10 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication. |
| 26 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Bus bar Panel Board of suitable size 800 x 700 x 450 mm, fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos, Digital ammeter 0-500 Amps with selector switch, digital voltmeter of 500 Volts with selector switch and LED/Neon type indicating lamps panel mounting type RYB-3 Nos, internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following:- (a) Internal wiring with 6 sqmm single core copper conductor cable/PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1 Job. (b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. INCOMING (c) MCCB 63 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUTGOING(d) MCB Triple Pole & Neutral (TPN) 25 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (e) MCB Single Pole & Neutral (SPN) 40 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (f) MCB Single Pole & Neutral (SPN) 25 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (g) MCB Single Pole & Neutral (SPN) 10 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication. |
| 27 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Bus bar Panel Board of suitable size 1100 x 1000 x 450 mm, fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos, Digital ammeter 0-500 Amps with selector switch, digital voltmeter of 500 Volts with selector switch and LED/Neon type indicating lamps panel mounting type RYB-3 Nos, internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following:- (a) Internal wiring with 6 sqmm single core copper conductor cable/PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1 Job. (b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. INCOMING (c) MCCB 100 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 25 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUTGOING (d) MCCB 63 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. (e) MCB Single Pole & Neutral (SPN) 40 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 No. (f) MCB Single Pole & Neutral (SPN) 25 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (g) MCB Single Pole & Neutral (SPN) 20 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication. |
| 28 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Bus bar Panel Board of suitable size 900 x 800 x 450 mm, fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos, Digital ammeter 0-500 Amps with selector switch, digital voltmeter of 500 Volts with selector switch and LED/Neon type indicating lamps panel mounting type RYB-3 Nos, internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following:- (a) Internal wiring with 6 sqmm single core copper conductor cable/PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1 Job. (b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. INCOMING (d) MCCB 63 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUT GOING (g) MCB Triple Pole & Neutral (TPN) 40 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 Nos. (h) MCB Triple Pole & Neutral (TPN) 25 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 Nos. (j) MCB Single Pole & Neutral (SPN) 40 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. (k) MCB Single Pole & Neutral (SPN) 25 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (l) MCB Single Pole & Neutral (SPN) 10 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication. Please Enable Macros to View BoQ information |
| 29 | Supply, installation, testing and commissioning in-replacement of Factory made (CPRI Approved) floor mounted Outdoor cubical type LT Bus bar Panel Board of suitable size 900 x 800 x 450 mm, fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame totally enclosed dust and vermin proof both side hinge opening arrangement on front and back, centre openable double door with locking arrangements, cable entry and exit from bottom with cable glands and gaskets, earth strip connections, Bus Bar chamber comprising 4 Nos copper strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding mounted on DMC insulator and suitable for 200 Amps with main indication IA - 03 Nos, Digital ammeter 0-500 Amps with selector switch, digital voltmeter of 500 Volts with selector switch and LED/Neon type indicating lamps panel mounting type RYB-3 Nos, internal wiring of suitable size to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar, including powder coat painting (RAL-7032) on the surfaces externally & internally including necessary preparation of surfaces and providing PCC (1 : 3 : 6) type C-2 as in foundation all as specified and as directed, comprising of the following:- (a) Internal wiring with 6 sqmm single core copper conductor cable/PVC Insulated Copper Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1 Job. (b) Fine wiring with 1.5sqmm single core copper conductor cable for instruments/indicating lamps-1 Job. INCOMING (d) MCCB 63 Amp, 4 Pole, 415 Volts rating with, overload, short circuit fault protection 3 phase with neutral link specially fixed incoming supply (Breaking capacity 16 KA)Ics=100% of Icu, with Spreader terminal of both side-01 No. OUT GOING (g) MCB Triple Pole & Neutral (TPN) 40 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 Nos. (h) MCB Triple Pole & Neutral (TPN) 25 Amp, 415 Volts rating specially fixed out going supply (Breaking capacity 10KA)-01 Nos. (j) MCB Single Pole & Neutral (SPN) 40 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. (k) MCB Single Pole & Neutral (SPN) 25 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-03 Nos. (l) MCB Single Pole & Neutral (SPN) 10 Amp, 'C' Curve, 240 Volts rating specially fixed out going supply (Breaking capacity 10KA)-02 Nos. Note-Fixing arrangement diagram and line diagram of the panel shall be got approved by accepting officer before panel fabrication. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender