Tender For Repair/Maint/Servicing Of Transformers Of Various Capacities Along With All The Accessories, Swithgears And Miscellaneous Connected Works In Age E/M-Ii Under Ge (C) Kirkee
Tender Value
49.96 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
20 days left
EMD
99920
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint/Servicing Of Transformers Of Various Capacities Along With All The Accessories, Swithgears And Miscellaneous Connected Works In Age E/M-Ii Under Ge (C) Kirkee
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in Hard/dense soil complete all as specified and directed by Engineer-in-Charge. |
| 2 | Excavation in trenches n.exc. 1.5 mtr in wide and exc. 1.5 mtr but n. exc 3.0 m in depth and getting out in Hard/dense soil complete all as specified and directed by Engineer-in-Charge. |
| 3 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge. |
| 4 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L for Boring of holes of 140 mm dia under the road/hard standing with trench less technology boring method upto 2 mtr below the surface for laying cable line complete all as specified and directed by Engineer-in-Charge. Note: All equipment & Machinery required to carry out the work will be provided by the contractor (If due to any obstruction during boring, reboring has to be done the same will be done by the contractor at his own cost the rates deem to cover the same). |
| 6 | M&L for laying double wall corrugated (DWC) high density polythene pipes size 135 mm outer dia having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & 14930 (Part-I and II) for protection of underground cable with all fittings such as clamps, coupler etc. laid in trenches/roads/nallah or fixed along wall/ poles or laid under floor (including cutting floor/road and making to match with existing adjouning surface etc. for cable protection complete all as specified and directed by Engineer-in-Charge. Note :- excavatoin and earth work measured and paid separately. |
| 7 | All as per item No. 06 above but size 100mm outer dia. complete all as specified and directed by Engineer-in-Charge. |
| 8 | Dismantling and taking out RCC poles/struts of any size complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply,erecting and fixing steel tubular swaged pole 11.00 mtr long type 410 SP-55confirming to IS - 2713 Prt I to III 1980 with and including cast iron base plate, finial taper plug, Nuts, bolts and washers etc and fixed into plain cement concrete foundation duly painted with two coats of aluminium paint over coat of red oxide primer including preparation of surfaces and making strip 150 mm wide up to 1.50 Mtr (above PCC coping ) by black, yellow, paint in alternate layer and pole numbers complete all as specified and directed by Engr-in-Charge. Note : Earth work, cement concrete will be measured and paid separetely. |
| 10 | M&L for cement concrete 1 : 4 : 8 type D-2 using 40 mm graded aggregate as in foundation for pole and any other indicated work including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 11 | M & L for cement concrete 1 :3 :6 type C-1 using 20 mm graded aggregate including necessary form work for coping of pole and any other indicated work complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply, laying in replacement, in trenches/trenchless bore/ducts/fixing on pole or any location as indicated, XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 x 300 sqmm with aluminium conductor suitable for 22 KV (E) grade as per relevent IS including latest amendment for IS testing, commissionong all as specified and directed including taking out of old burnt out cable complete all as specified and directed by Engineer-in-Charge . |
| 13 | All as per Item No-12 above but of size 3 x 120 sqmm NOTE FOR ITEM NO.12&13 :- (i) Excavation , earthwork, and sand cushioning, PCC protection cover, GI pipe & protectioin clamps shall be measured and paid for separately. (ii) Manual excavation has be carried out at the places of services such as of near existing HT/LT cables, OFC/Telecom cables, water pipe line, area drinages and contractor shall be responsible for rectification of damages immediately on priority to the damages of services occured during execation of the cable/earth work. (iii) High voltage test to be carried out after laying & jointing of cables and test sheet to be submitted by contractor. All arrangement for the same shall be provided by the contractor & shall be considered within the qoted rates. Please Enable Macros to View BoQ information |
| 14 | All as per Item No-12 above but of size 3 x 120 sqmm NOTE FOR ITEM NO.12&13 :- (i) Excavation , earthwork, and sand cushioning, PCC protection cover, GI pipe & protectioin clamps shall be measured and paid for separately. (ii) Manual excavation has be carried out at the places of services such as of near existing HT/LT cables, OFC/Telecom cables, water pipe line, area drinages and contractor shall be responsible for rectification of damages immediately on priority to the damages of services occured during execation of the cable/earth work. (iii) High voltage test to be carried out after laying & jointing of cables and test sheet to be submitted by contractor. All arrangement for the same shall be provided by the contractor & shall be considered within the qoted rates. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 05, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender