Defence Government Departments Closing in 5 days TDR #57362475

Tender For Repair And Maintenance Of Electrical Fitments Of Sos Mess Under Bsf Academy Gwalior.

Issued by Government Departments · Gwalior, Madhya Pradesh
Tender Value
5.35 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
5 days left
EMD
10706
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gwalior → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Electrical Fitments Of Sos Mess Under Bsf Academy Gwalior.

BOQ

Name of Work:- Repair and maintenance of electrical fitments of Sos mess under BSF Academy Gwalior.
Sl. No. Item Description
1Supplying, installation, Testing & Commissioning ofLED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life nds, CCT 3000°K / 4000°K / 5700°K /6500°K 46(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 40 Watt
2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group B)
3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group B)
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
53 x 1.5 sq. mm
66 x 1.5 sq. mm
7Supplying and fixing following piano type switch/socket on the existing switch box/ cover including connections etc. as required.
85/6 amps switch
915/16 A switch
103 pin 5/6 A socket outlet
116 pin 15/16 A socket outlet
12Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
13Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
14Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (a) 36 Watt
15SITC of 10 watt ( 2 feet long) surface/wall mounted extructed aluminium housing LED batten suitable for mirror light and integrated driver including connection as required .Efficacy 100 LPW of cat Ref CCS-103-10-65-SL-DP-NWH of Crompton make or its equivalent make of Havells/Philips/Wipro.
16SITC of 18 watt round/square surface mounted LED panel light ,230 volt ,50 HZ ,AC supply with high power LED lamp ,electronic driver ,diffuser including connection as required. Efficacy >110/120 LPW of cat Ref LCDSPLN-S-18-CDL of Crompton or its equivalent make of Havells/Philips/Wipro.
17Supply and installation of 1200 mm ceiling fan including wiring the down rod of standard length (Upto 90 cm ) with 1.5 sq mm FRLS PVC Insulated copper conductor ,single core cable etc as required.Model sea wind of Crompton or its eqt make of Usha /Havells/Bajaj
18Providind and fixing of mettalic exhaust fan 300 mm with louvers, fasteners including cutting hole in the wall, connection, testing and commissioning etc as reqd. cat no. FHVVEMTDBB12 (Havells) or equivalent model & specification of Havells/ Orient/Bajaj/Crompton make
19SITC of decorative wall mounting antique brass finish with opal glass suitable for 9 watt lamp complete etc as required of cat no WMAFBULB of crompton make or its make of Havells/ Crompton/Philips/Jaquor/Wipro.
20Supplying and fixing of 5-star rating 15 Litre capacity electric water heater(geyser) of rated power 2KW ,240 Volt 50 Hz AC supply of model Omnis R of Racold or its eqt make of Bajaj/ Hindware /Havells / Crompton make.
21Repair and rewinding of ceiling fan of size 48\\" (1200 mm ) with suitable size super enammeled copper wire of approved brand size i/c retrived of burnt wire and connection ,taping ,varnishing and testing assembling etc as required (Rate after deduction the cost of burnt wire and other material.)
22Repair and rewinding of exhaust fan of size upto 300 mm heavy duety with suitable size of super enammeled copper wire of approved brand of of size i/c bearing bush ,capacitor ,connection taping varnishes and testing assembling etc as required. (After deduction the cost of burnt wire and other material.) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57362475
AUTHORITY Government Departments
TENDER VALUE 5.35 Lakhs
LAST DATE 14-09-2026
Authority
Authority Name Border Security Force
Work Description Tender for Repair And Maintenance Of Electrical Fitments Of Sos Mess Under Bsf Academy Gwalior.
Basic Detail
Tender No 35/5408/NIT/ENGG/ELECT/2026-27
Bidding Type Tender
Location
City Gwalior
State Madhya Pradesh
Key Dates
Publish Date 05 Sep 2026
Submission Date 14 Sep 2026
Open Date 15 Sep 2026
Finance
Tender Value 5.35 Lakhs
Tender Fee Ref. Documents
EMD 10706
Exemption Not Available
Document List
BOQ_972040.xls
dfa8a489-b016-4ddb-8525-184d2b3bc990.html
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_972040.xls

html

dfa8a489-b016-4ddb-8525-184d2b3bc990.html

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders